A Study for the Measurement Method of Electromagnetic Field Strength of Power Line Communications Modem (전력선통신모뎀의 전자계강도 측정방법 연구)

  • Jang Dong-Won
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.162-165
    • /
    • 2006
  • This paper describes a measurement method for electromagnetic field strength of power-line communications(PLC) modem. First it outlines the technology used in PLC modems, and the technical regulation being offered to the technology, from the point of view of its effect on electromagnetic compatibility (EMC). The radio spectrum needs protection from other interferers, and there is a regime in place to provide this protection. Difficulties in achieving compatibility between the requirements for radio protection and the requirements for operation of the PLC modem mean that there is no consensus as yet as to how PLC modem components can be made compliant with EMC requirements globally. It is concluded that there is a measurement method according to CISPR standards which satisfy requirements in domestic regulation.

  • PDF

The Implementation of Digital Broadcasting Content Copy Protection Manager in PVR (Personal Video Recording)

  • Lim Tae-Bum;Kim Yun-Sang;Lee Seok-Pil;Jung Jong-Jin
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.99-102
    • /
    • 2006
  • This paper describes a article how to protect from illegal indiscriminate copy of digital broadcasting content using DRM and CCI. With the start of terrestrial / satellite digital broadcast and the preparation of Digital Cable broadcast, we can view HD digital contents through the various channel. Also we can record, play, redistribute digital contents in PVR. The protection of Digital Contents Right became of the important issue to protect CopyRight. In this paper, we implement a manager that prevents indiscriminate digital contents redistribution of the digital broadcast contents. For protection of Digital contents Right, we use BF(Broadcast Flag) and CCI (Copy Control Information) which we can control viewing or copy digital contents with.

  • PDF

Gigabit Ethernet PON(Passive Optical Network) Protection OPNET Simulation (기가비트 이더넷 폰 링크 프로텍션 OPNET 구현)

  • Lee Min-Hyo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.223-227
    • /
    • 2006
  • HD(High Density) 방송의 시작됨에 따라 광대역 멀티미디어 서비스에 대한 관심이 고조되고 있다. 광대역 멀티미디어 서비스를 하기 위한 전송 매체로 광선로를 이용한 댁내 전송 방식인 FTTH(Fiber To The Home)이 주목받고 있고 특히 AON(Active Optical Network)에 비해 구축, 유지 보수비용에 장점을 가지고 있는 PON을 이용한 방식이 선호되고 있다. PON을 이용한 표준으로 현재 IEEE802.3AH Group에서 표준 완료 된 Gigabit Ethernet PON 있으나 링크 장애에 대한 안정성 고려가 빠져 있다. 이에 본 논문은 멀티미디어 서비스에서 중요시되는 링크 장애에 대한 안정성 확보를 위한 GE-PON Link Protection 방안을 제시하며 OPNET Simulation을 구현하였다.

  • PDF

Simulation analysis for evacuation safety countermeasure in underground facilities (지하공간시설에서의 피난안전대책을 위한 시뮬레이션 해석)

  • Kim, Bong-Chan;Kim, Se-Jong;Kim, Gyeong-Gu;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.100-105
    • /
    • 2011
  • 본 연구에서는 재실자의 밀도가 높은 지하상가는 공간의 특성상 화재가 발생할 경우 다량의 유독가스의 발생 및 연기의 이동경로와 인간의 피난경로 일치로 인하여 피난안전에 큰 위험성이 있다고 사료된다. 이에 지하철 역사와 연결되어 있는 지하상가를 선정 후, 일본 피난안전성평가수법과 FDS(Fire Dynamic Simulator) 및 SIMULEX를 이용하여 비교 분석을 하였으며, 그 결과, 화재발생 후 6분이 경과 시 위험한 것으로 판단되었다. 그에 대한 대책으로 자연 배연구를 설치하여 시뮬레이션 수행을 한 결과 가시도확보 및 각 출구에서의 온도가 하강하는 것을 확인할 수 있었다.

  • PDF

A Study on Prediction of Glass Breakage in Fire of Housing Facilities (주거시설의 화재시 유리파손 예측에 관한 연구)

  • Kim, Bong-Chan;Kim, Dong-Eun;Hwang, Hyun-Bae;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.393-396
    • /
    • 2011
  • 본 연구는 유리내화실험을 실시하고 일본 동경이과대학에서 실시된 유리내화실험과 비교 분석하였으며, 분석결과, 실험에서 유리내화성능은 접합유리, 강화유리, 복층유리, 일반유리 순으로 나타났으며, 유리의 균열이 발생 후 일반유리는 $62^{\circ}C$, 접합유리는 $48^{\circ}C$, 복층유리는 $27^{\circ}C$가 상승한 후 파괴되었다. 일본의 실험에서는 일반유리의 경우 본 실험과 비교 시 비교적 낮은 온도로 측정되었으나 이는 가열조건에 차이에 따른 것으로 판단된다.

  • PDF

Management Criteria of Underground Strage Tank for Prevention of Soil Contamination (토양오염방지를 위한 지하저장탱크의 관리 방안 연구)

  • Kim, Joon Hyun;Han, Young Han
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.453-460
    • /
    • 1998
  • The purpose of this study was to analyze their status of underground storage tank(UST) facilities and level of soil contamination, and to establish its management criteria. DB program was developed to analyze the correlation between specific characteristic of UST and level of soil contamination. For a suitable management of UST, leakage monitoring and inspection method of UST was investigated. Inspection period was established based on the leakage rate. The most dominant factor for leakage seemed to be caused by the corrosion. Therefore, main factor, construction method and installation year of UST, and corrosion protection system were suggested for optimal protection of UST. Considering the present management status of UST in Korea, inspection and management criteria of UST should be accomplished in term of contamination protection of leakage, and flexible regulation act should be introduced for each specific site.

  • PDF

Comparison and Analysis of Domestic and Foreign Standard for electrical equipment installation of amusement park and ride (유원시설 전기설비 설치에 대한 국내외 규정 비교 분석)

  • Kim, Gi-Hyun;Kim, Chong-Min;Kim, Han-Sang
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.378-382
    • /
    • 2004
  • This paper gives information which is applied to install the electrical equipment of amusement park and ride. For analyzing the standard of electrical equipment installation, we research the related regulation of National Electrical Code(2002), IEC 60364-series and Technical standards for Electrical facilities of internal standard. Among electrical equipments of amusement park and ride, especially we study the transformer vaults, overcurrent protection and ground protection of electrical equipment. So we the furnished the installation information of transformer vaults, overcurrent and ground protection at amusement park and ride.

  • PDF

A study on the implementation of DRM system in digital home networking (디지털 홈네트워킹 환경에서의 DRM 시스템 구축)

  • Kim, Jong-An;Ryu, Jung-Seob;Han, Pyung-Hee;Kim, Jin-Han
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2005.08a
    • /
    • pp.104-108
    • /
    • 2005
  • Due to the rapid spread of high speed Internet access and the contents digitization, the demand for the copyright protection of digital contents has increased continuously so that the digital rights protection technology becomes one of the inevitable components in the digital content providing services. This paper describes the current trend of DRM(Digital Rights Management) technology and how to implement the system for the protection of digital assets in the digital home networking environment.

  • PDF

Basic study on the protection of Korean power system applying superconducting devices (초전도 전력기기 적용에 따른 계통보호문제 고찰)

  • Lee, Seung-Ryul;Yoon, Jae-Young;Lee, Byong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.625-626
    • /
    • 2007
  • This study is on the protection system of Korean power system applying superconducting power devices. We investigates firstly protection systems of Korean power system and then do a basic study on the impact of relay systems in the power system with superconducting devices. For the more reliable result, we will carry out relay operation tests in the power system applying superconducting facilities using RTDS(Real Time Digital Simulator) in the future.

  • PDF

Installation of Test Equipment for Lightning Surge Complying with International Standard (국제시험규격에 적합한 뇌서지 시험설비 구축)

  • Lee, Tae-Hyung;Cho, Sung-Chul;Eom, Ju-Hong;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.360-364
    • /
    • 2006
  • Recently KS documents related to lightning protection were revised complying with the requirements of IEC standards. Lightning protection parts are divided three in IEC, those are arrestor(60099), SPD(61643), and protection facilities(62305). According as international standard is applicable in Korea, type tests, routine tests, and acceptance tests shall be made to demonstrate compliance with the relevant standards. KESRI have installed test equipment which is funded by Ministry of Commerce, Industry and Energy fit for lightning surge test form 2002, and we introduce the test equipments in detail.

  • PDF