• 제목/요약/키워드: Protaper

검색결과 12건 처리시간 0.023초

엔진 구동형 니켈 티타늄 파일을 이용한 거터퍼쳐의 제거 효과 (THE EFFECT OF GUTTA-PERCHA REMOVAL USING NICKEL-TITANIUM ROTARY INSTRUMENTS)

  • 전정훈;민정범;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제29권3호
    • /
    • pp.212-218
    • /
    • 2004
  • The purpose of this study was to quantify the amount of remaining gutta-percha/sealer on the walls of root canals when three types of nickel-titanium rotary instruments (Profile. ProTaper and $K^3$) and a hand instrument(Hedstrom file) used to remove these materials. The results of this study were as follows: 1. In the total time for gutta-percha removal. Profile group was the fastest and followed by $K^3$, Protaper, Hedstrom file group. 2. In case of the evaluation of the volume of remained gutta-percha from radiograph. $K^3$ group got the highest score and followed by Protaper. Hedstrom file. Profile group in the apical 1/3. 3. In case of the evaluation of the volume of gutta-percha remained from stereomicroscope, $K^3$ group got the highest score and followed by Protaper. Hedstrom file. Profile group in the apical 1/3. These results showed that instrumentation using nickel-titanium rotary instrument groups was faster than that using hand instrument group. The effect of gutta-percha removal using Profile group was better than that using Protaper and $K^3$ group in the nickel-titanium rotary instrument groups.

Comparison of the cyclic fatigue resistance of One Curve, F6 Skytaper, Protaper Next, and Hyflex CM endodontic files

  • Charlotte Gouedard;Laurent Pino;Reza Arbab-Chirani;Shabnam Arbab-Chirani;Valerie Chevalier
    • Restorative Dentistry and Endodontics
    • /
    • 제47권2호
    • /
    • pp.16.1-16.9
    • /
    • 2022
  • Objectives: This study compared the cyclic fatigue resistance of One Curve (C wire) and F6 Skytaper (conventional austenite nickel-titanium [NiTi]), and 2 instruments with thermos-mechanically treated NiTi: Protaper Next X2 (M wire) and Hyflex CM (CM wire). Materials and Methods: Ten new instruments of each group (size: 0.25 mm, 6% taper in the 3 mm tip region) were tested using a rotary bending machine with a 60° curvature angle and a 5 mm curvature radius, at room temperature. The number of cycles until fracture was recorded. The length of the fractured instruments was measured. The fracture surface of each fragment was examined with a scanning electron microscope (SEM). The data were analyzed using one-way analysis of variance and the post hoc Tukey test. The significance level was set at 0.05. Results: At 60°, One Curve, F6 Skytaper and Hyflex CM had significantly longer fatigue lives than Protaper Next X2 (p < 0.05). No statistically significant differences were found in the cyclic fatigue lives of One Curve, F6 Skytaper, and Hyflex CM (p > 0.05). SEM images of the fracture surfaces of the different instruments showed typical features of fatigue failure. Conclusions: Within the conditions of this study, at 60° and with a 5 mm curvature radius, the cyclic fatigue life of One Curve was not significantly different from those of F6 Skytaper and Hyflex CM. The cyclic fatigue lives of these 3 instruments were statistically significantly longer than that of Protaper Next.

근관의 치경부 조기 확대가 치근단 잔사 정출에 미치는 효과 (THE EFFECT OF EARLY CORONAL FLARING ABOUT APICAL EXTRUSION OF DEBRIS)

  • 김민경;미정범;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.147-152
    • /
    • 2004
  • The purpose of this study was to investigate the quantity of debris which was extruded apically after canal instrumentation using different types of enlarging instrument in endodontic resin models. Five groups of 9 endodontic resin models were instrumented using each different technique : hand instrumentation without early coronal flaring. hand instrumentation after early coronal flaring. and three nickel-titanium engine-driven instrumentations (Hero 642, Protaper, $K^$). Debris extruded from apical foramen during instrumentation was collected on preweighed CBC bottle, desiccated and weighted using electronic balance. The results were analyzed using Kruskal-wallis test and Mann-Whitney U rank sum test at a significance level of 0.05. The results were as follows: 1. All of instrumentation techniques produced apically extruded debris. 2. Group without early coronal flaring extruded significant more debris than groups with early coronal flaring. 3. There was no significant difference among early coronal flaring groups. The early coronal flaring is very important to reduce the amount of debris extruded apically.

A study on the quantity of apical extrusion of debris according to early coronal flaring

  • Kim, Min-Kyung;Hwang, Ho-Keel
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.580-580
    • /
    • 2003
  • I. Objectives This study investigated the quantity of debris which was extruded apically after canal instrumentation using different types of enlarging instrument in endodontic resin models. II. Materials and Methods Five groups of 9 endodontic resin model were instrumented using each different technique:hand instrumentation without early coronal flaring, hand instrumentation after early coronal flaring, and three nickel-titanium engine-driven instrumentations(Hero 642, Protaper, K3) after early coronal flaring.(omitted)

  • PDF

수종의 엔진구동형 Nickel-Titanium file을 이용한 근관형성 방법이 근관만곡도 유지능력에 미치는 영향 (EFFECT OF VARIOUS CANAL PREPARATION TECHNIQUES USING ROTARY NICKEL-TITANIUM FILES ON THE MAINTENANCE OF CANAL CURVATURE)

  • 이철환;조경모;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제28권1호
    • /
    • pp.41-49
    • /
    • 2003
  • There are increasing usage of Nickel-Titanium rotary files in modern clinical endodontic treatment because it is effective and faster than hand filing due to reduced step. This study was conducted to evaluate the effect of canal preparations using 3 different rotary Nickel-Titanium files that has different cross sectional shape and taper on the maintenance of canal curvature. Simulated resin block were instrumented with Profile(Dentsply, USA), GT rotary files(Dentsply, USA), Hero 642(Micro-Mega France), and Pro-Taper(Dentsply, USA). The image of Pre-instrumentation and Post-instrumentation were acquired using digital camera and overspreaded in the computer. Then the total differences of canal diameter, deviation at the outer portion of curvature, deviation at the inner portion of curvature, movement of center of the canal and the centering ratio at the pre-determined level from the apex were measured. Results were statistically analyzed by means of ANOVA, followed by Scheffe test at a significance level of 0.05. The results were as follows; 1. Deviation at the outer portion of curvature, deviation at the inner portion of curvature were showed largest in Pro-Taper so also did in the total differences of canal diameter(p<0.05). 2. All the groups showed movements of center Profile combined with GT rotary files and Hero 642 has no difference but Pro-Taper showed the most deviation(p<0.05). 3. At the 1, 2, 3mm level from the apex movements of center directed toward the outer portion of curvature, but in 4, 5 mm level directed toward the inner portion of curvature(p<0.05). As a results of this study, it could be concluded that combined use of other Nickel-Titanium rotary files is strongly recommended when use Pro-Taper file because it could be remove too much canal structure and also made more deviation of canal curvature than others.

Corrosion resistance assessment of nickel-titanium endodontic files with and without heat treatment

  • Tatiana Dias Costa;Elison da Fonseca e Silva;Paula Liparini Caetano ;Marcio Jose da Silva Campos ;Leandro Marques Resende ;Andre Guimaraes Machado;Antonio Marcio Resende do, Carmo
    • Restorative Dentistry and Endodontics
    • /
    • 제46권1호
    • /
    • pp.6.1-6.10
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the corrosion resistance of heat-treated (Reciproc and WaveOne) and non-heat-treated (ProTaper and Mtwo) superelastic nickel-titanium endodontic files when immersed in a 5.25% sodium hypochlorite solution. Materials and Methods: Anodic polarization curves were obtained with potential sweeps that began at the open circuit potential or corrosion potential (Ecorr). The pitting potential (Epit) was identified on the anodic polarization curve as the potential at which a sudden increase in current was observed. The micromorphology of the 28 tested files was analyzed before and after the electrochemical assay using scanning electron microscope (SEM). The data were analyzed using 1-way analysis of variance with the post hoc Bonferroni test (for Ecorr) and the Student t-test for independent samples (for Epit). Results: The mean Ecorr values were 0.506 V for ProTaper, 0.348 V for Mtwo, 0.542 V for Reciproc, and 0.321 V for WaveOne files. Only WaveOne and Protaper files exhibited pitting corrosion, with Epit values of 0.879 V and 0.904 V, respectively. On the SEM images of the ProTaper and WaveOne files, cavities suggestive of pitting corrosion were detected. Conclusions: Signs of corrosion were observed in both heat-treated and non-heat-treated files. Of the evaluated files, WaveOne (a heat-treated file) and ProTaper (a non-heat-treated file) exhibited the lowest corrosion resistance.

다양한 레진시멘트로 합착한 섬유포스트의 결합강도 비교 (COMPARISON OF BOND STRENGTH OF A FIBER POST CEMENTED WITH VARIOUS RESIN CEMENTS)

  • 이현아;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제33권6호
    • /
    • pp.499-506
    • /
    • 2008
  • 이 연구는 다양한 접착시스템을 사용하는 6가지 레진시멘트를 이용하여 근관에 합착한 섬유포스트를 push-out 검사에 의해 포스트와 치근 상아질 간의 결합강도를 상호 비교하기 위하여 시행되었다. 발거된 하악 소구치의 치관부를 제거하고 치근부를 근관충전한 후 9mm의 포스트 룸을 형성하였다. 사용된 레진시멘트의 종류에 따라서 무작위로 6개씩 선택하여 Duo-Link 군, Variolink II 군, Panavia F 군, Multilink Automix 군, RelyX Unicem 군, Maxcem 군으로 분류하였다. 제조사의 지시에 따라서 각각의 레진시멘트를 Uni-dose needle tip을 이용하여 근단부에서부터 주입하여 광투과성 섬유 포스트인 no. 2 DT Light Post를 근관에 합착하였다. 증류수에 24시간동안 보관한 후, 주수 하에 저속의 Diamond Wheel Saw를 이용하여 각 치근을 횡단면으로 1mm 두께로 절단하여 연속적인 절편 6개를 얻었다. 각 군의 시편을 universal testing machine에 고정하고 push-out 검사를 시행하여 push-out 강도를 통계 분석한 결과, 서로 다른 접착시스템을 사용한 레진시멘트 군간의 push-out 강도는 유의한 차이가 나타나지 않았다 (p > 0.05).

ProFile®, ProTaperTM 및 K3TM Ni-Ti 파일의 과기구 조작이 치근단공 변위에 미치는 영향 (A STUDY ON TRANSPORTATION OF APICAL FORAMEN AFTER OVERINSTRUMENTATION BY PROFILE® ;PROTAPERTM AND K3TM IN SIMULATED CANALS WITH DIFFERENT CURVATURES)

  • 양현;양인석;황윤찬;황인남;윤숙자;김원재;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제32권2호
    • /
    • pp.87-94
    • /
    • 2007
  • 본 연구는 ProFile, ProTaper 및 $K^3$를 이용하여 과잉 기구 조작에 의해 근관 성형 시 근관의 만곡형태와 Ni-Ti 파일의 종류에 따라 치근단공이 어떻게 변위 되는지를 비교 분석하고자 시행되었다. 본 실험에서는 레진모형근관으로 J자와 S자의 근관 형태가 재현된 ENDO-TRAINING BLOC을 사용하였다 근관성형 기구로는 $ProFile^{(R)},\;ProTaper^{TM},\;K^{3TM}$를 사용하였다. 총 60개의 레진모형근관을 사용하였으며, 사용된 레진모형근관 및 Ni-Ti 파일의 종류에 따라 10개씩 6개의 군으로 나누어 근관성형을 시행하였다. 근관 성형 전 후 이미지를 Image-analyzing microscope 100X를 이용하여 얻고 Photoshop 7.0 프로그램을 이용하여 중첩하였다. 이미지 분석 프로그램을 이용하여 근관 성형 전 후 치근단공의 중심으로부터의 직경 변화량과 면적을 측정한 결과 만곡된 근관의 성형시 치근단공이 주로 만곡의 외측으로 변위됨을 나타내며 ProFile이 ProTaper나 $K^3$보다 통계적으로 유의성이 있게 작은 변화량을 나타내어 근관성형시 바람직한 기구임을 시사한다.

레진모형근관에서 엔진구동형 및 수동형 ProTaper 파일로 근관성형 후 근관형태 변화에 대한 비교연구 (A COMPARATIVE STUDY OF THE CANAL CONFIGURATION AFTER SHAPING BY PROTAPER ROTARY AND HAND FILES IN RESIN SIMULATED CANALS)

  • 양인석;강인철;황윤찬;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제30권5호
    • /
    • pp.393-401
    • /
    • 2005
  • 본 연구는 형태 및 재질이 동일한 엔진구동형 ProTaper파일과 수동형 ProTaper파일을 이용하여 레진모형근관을 성형한 후 근관형태 변화를 비교 분석하고자 시행되었다. 본 연구에서는 레진모형근관으로 총 40개의 J자와 S자의 근관 형태가 재현된 ENDO-TRAINING BLOC을 사용하였다. 근관 성형 기구로는 엔진구동형 Ni-Ti 파일로 $ProTaper^{TM}$, 수동형 Ni-Ti 파일로 $ProTaper^{(R)}$ For Hand Use를 사용하였다. 사용된 레진모형근관과 파일의 종류에 따라 10개씩 4개의 그룹으로 나누어 근관성형을 시행하였다. 근관 성형 전$\cdot$후 이미지를 스캐너 (Color scanner, UMAX Technologies, Inc., USA)를 이용하여 얻은 후. Photoshop 7.0 프로그램 (Adobe System Inc., USA)을 이용하여 이미지를 중첩하였다. 이미지 분석 프로그램 (Image-$Pro^{(R)}$ Plus, Media Cybernetic, USA)을 이용하여 치근단 쪽에서부터 0, 1, 2, 3, 4, 5, 6 및 7 mm 수준에서 근관 성형에 따른 근관의 내측 및 외측 폭경의 변화량, 근관 총폭경의 변화량, 근관 중심축의 변위량을 측정하였다. 또한 근관 성형 시간을 기록하였다. 두 기구 사이의 유의성 검정을 위해 독립 표본 t-검정을 시행하여, 근관 성형 시 수동형 ProTaper 파일이 엔진구동형 ProTaper 파일에 비해 근관 중심축의 변위가 유의하게 덜 일어나며 근관의 원래 형태를 더욱 잘 유지할 수 있지만, 근관 성형시간은 길어질 수 있다는 결론을 얻었다.

ProFile, ProTaperTM K-Flexofile 근관 성형시 근관의 만곡도에 따른 근관 형태 변화 비교연구 (A COMPARATIVE STUDY ON THE CANAL CONFIGURATION AFTER SHAPING BY PROFILE, PROTAPERTM AND K-FLEXOFILE IN SIMULATED CANALS WITH DIFFERENT ANGLES OF CURVATURE)

  • 이보금;김동준;황윤찬;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제30권4호
    • /
    • pp.294-302
    • /
    • 2005
  • 본 연구는 ProFile, ProTaper 및 K-Flexofile로 근관 성형시 근관의 만곡도에 따라 근관의 형태가 어떻게 변화하는지를 비교 분석하고자 시행되었다. ISO #15 finger spreader를 15도, 30도 및 45도로 만곡시키고 에폭시 레진으로 각각도의 근관을 갖는 30개의 근관 모형을 제작하였다. 근관의 길이는 18mm로 하였고 근관의 만곡은 근관의 입구로부터 10mm 부위에서 시작하도록 제작하였다. 근관 성형에는 엔진 구동형 니켈-타이타늄 파일인 ProFile과 ProTaper, 수동형 stainless steel 파일인 K-Flexofile을 사용하였다. ProFile과 ProTaper는 제조자의 지시에 따라 크라운다운법으로 근관 성형하였고, K-Flexofile은 스텝백법으로 근관 성형하였다. 근첨부 성형은 #25파일 크기까지 시행하였다. 근관 성형 전 후 이미지를 스캐너를 이용하여 얻고 Photoshop 7.0프로그램을 이용하여 중첩하였다. 이미지 분석 프로그램을 이용하여 치근단 쪽에서부터 1, 2, 3, 4, 5, 6, 7, 8, 9및 10mm부위의 내 외측 폭경 변화와 총폭경 및 근관의 중심축에 대한 근관 변위을 측정하였다. 각 부위에서 내 외측 폭경과 총폭경 및 근관 변위의 유의성 검정을 위해 one-way ANOVA분석을 시행하였으며 각 기구간의 유의성 검정은 Scheffe's test로 사후 분석하였다. 또한 기구의 변형과 파절 여부를 평가한 결과 엔진 구동형 니켈-타이타늄 파일인 ProFile과 ProTaper를 사용하여 근관성형시 수동형 스테인레스 스틸 파일인 K-Flexofile에 비해 근관의 변위를 적게 유발하고 특히 ProFile이 근관 성형시 바람직한 기구임을 시사하였다.