• Title/Summary/Keyword: Prosthetic mitral valve

Search Result 114, Processing Time 0.027 seconds

Clinical Experiences of Open Heart Surgery (개심술(開心術) 2,000례의 임상적 고찰)

  • 김하늘루;박경택;곽기오;한일용;소영환;최강주;이양행;조광현
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1183-1194
    • /
    • 1998
  • Background: From Sept. 1985 to Sept. 1997, 2,000 cases of open heart surgery(OHS) were performed in the Department of Thoracic & Cardiovascular Surgery, Pusan Paik Hospital, College of Medicine, Inje University. Material and Method: Among the total of 2,000 cases of OHS, 1532 cases were congenital heart disease(CHD) and 468 cases were acquired heart disease(AHD). The age distribution was 9 days(4.0kg) to 68 years in CHD and 11 to 66 years in AHD. In 1532 cases of CHD, there were 1403 acyanotic cases and 129 cyanotic cases. Result: The CHD cases consisted of 940 ventricular septal defects(61.4%), 324 atrial septal defects(21.1%), 112 tetralogy of Fallot(7.3%), 46 pulmonary stenosis(3%), 38 endocardial cushion defects(2.5%), 15 valsalva sinus ruptures(1%), 4 transposition of great arteries (0.3%), 4 double outlet right ventricles(0.3%), and etc. Corrective operations were applied for congenital heart disease with a result of 3.1% hospital mortality. Of 468 AHD, 381 cases were valvular heart diseases, 48 ischemic heart diseases, 12 cardiac tumors, 8 annuloaortic ectasias, 16 dissecting aortic aneurysms and etc. In the 381 valvular heart diseases, there were 226 single valve replacements(36 aortic valve replacements(AVR), 188 mitral valve replacements(MVR), and 2 tricuspid valve replacements(TVR), among these were 71 cases of double valve replacements(AVR & MVR), 54 cases of MVR with tricuspid valve annuloplasty(TVA), and 18 cases of AVR, MVR with TVA. The total implanted prosthetic valves were 466. In MVR, 123 St. Jude Medical valves, 90 Carpentier-Edwards valves, 65 CarboMedics valves, 42 Sorin valves and 16 other valves were used. In AVR, 68 St. Jude Medical valves, 36 CarboMedics valves, 14 Carpentier-Edwards valves and 9 other valves were used. Coronary Artery Bypass Surgery(CABG) were performed in 48 cases. The patterns of bypass graft were 14 patients of single vessel graft, 21 patients of two vessels graft, 10 patients of three vessels graft and 3 patients of four vessels graft. Conclusion: The hospital operation mortality rate of congenital acyanotic, cyanotic and acquired heart diseases were 2.0%, 15.5%, and 5.1% respectively. The overall mortality rate was 3.6%(72/2,000).

  • PDF

Determination of Practical Dosing of Warfarin in Korean Outpatients with Mechanical Heart Valves (인공심장판막 치환환자의 Warfarin 용량결정)

  • Lee Ju Yeun;Jeong Young Mi;Lee Myung Koo;Kim Ki-bong;Ahn Hyuk;Lee Byung Koo
    • Journal of Chest Surgery
    • /
    • v.38 no.11 s.256
    • /
    • pp.761-772
    • /
    • 2005
  • Background: Following the implantation of heart valve prostheses, it is important to maintain therapeutic INR to reduce the risk of thromboembolism. The objective of this study was to suggest a practical dosing guideline for Korean outpatients with prosthetic heart valves managed by a pharmacist-run anticoagulation service (ACS). Material and Method: A retrospective chart review was completed for all patients enrolled in the ACS at Seoul National University Hospital from March, 1997 to September, 2000. Patients who were at least 6 months post-valve replacement and had nontherapeutic INR value (less than 2.0 or greater than 3.0) were included. The data on 688 patients (1,782 visits) requiring dosing adjustment without any known drug or food interaction with warfarin were analyzed. The amount of adjusted dose and INR changes based on the INR at the time of the event were calculated. Aortic valve replacements (AVR) patients and mitral or double valve replacement (MVR/DVR) patients were evaluated separately. Result: Two methods for the warfarin dosage adjustment were suggested: Guideline I (mg-based total weekly dose (TWD) adjustment), Guideline II (percentage-based TWD adjustment). The effectiveness of Guideline 1 was superior to Guideline II overall in patients with both AVR and MVR/DVR. Conclusion: The guideline suggested in this study could be useful when the dosage adjustment of wafarin is necessary in outpatients with mechanical heart valves.

Composite Graft Aortic Root Replacement with Coronary Button Reimplantation: The Early and Mid-Term Results (Composite graft를 이용한 대동맥근부 치환술: Button 술식의 중단기 결과)

  • 나찬영;백만종;김웅한;오삼세;김수철
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.356-364
    • /
    • 2002
  • Background: This study was undertaken to investigate the outcome of composite graft aortic root replacement using coronary button reimplantation technique for the treatment of aneurysms of the ascending aorta involving the aortic root. Material and Method: Between April 1995 and September 2001, 54 patients having aortic root replacement with a composite valve graft using direct coronary button reimplantation were reviewed retrospectively. Left ventricular dysfunction was present in 14 patients(25.9%), aortic regurgitation in 48(89%), and Marfan's syndrome in 17(31.5%). The indications for operation were annuloaortic ectasia in 29 patients(53.7%), aortic dissection in 11(20.4%), aneurysms of the ascending aorta involving aortic root in 12(22.2%), and aortitis in 2(3.7%). Six patients(11.1%) had previous cardiac or ascending aortic operations. Concomitant procedures were arch replacement in 21 patients(38.9%), coronary artery bypass graft in 7(13%), mitral valve repair or replacement in 4(7.4%), and others in 6. The mean time of circulatory arrest, total bypass, and aortic crossclamp were 18 $\pm$ 9 minutes, 177 $\pm$ 42 minutes, and 127 $\pm$ 31 minutes, respectively. Result: There was 1 early death(1.9%). Mean follow-up was 24.6$\pm$ 19.5 months. There were two late deaths(3.8%) including one death due to the traumatic cerebral hemorrhage. The Kaplan-Meier survival rate was 98.0 $\pm$ 2.0% and 93.1 $\pm$ 5.1% at 1 and 6 years, respectively. Two patients required reoperation owing to a false aneurysm at the root anastomosis site and a malfunction of prosthetic aortic valve(3.8%). Staged operation for dissection of the remaining thoracoabdominal aorta was performed in 1 patient. The freedom rate from reoperation was 97.8 $\pm$ 2.0% and 65.3 $\pm$ 26.7% at 1 and 6 years, respectively.

Reoperations on the Aortic Root and Ascending Aorta (대동맥근부 혹은 상행대동맥의 재수술)

  • Baek, Man-Jong;Na, Chan-Young;Kim, Woong-Han;Oh, Sam-Se;Kim, Soo-Cheol;Lim, Cheong;Ryu, Jae-Wook;Kong, Joon-Hyuk;Kim, Wook-Sung;Lee, Young-Tak;Moon, Hyun-Soo;Park, Young-Kwan;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.188-198
    • /
    • 2002
  • Background: Reoperations on the aortic root or the ascending aorta are being performed with increasing frequency and remain a challenging problem. This study was performed to analyze the results of reoperations on the ascending aorta and aortic root. Material and Method: Between May 1995 and April 2001, 30 patients had reoperations on the ascending aorta and aortic root and were reviewed retrospectively. The mean interval between the previous repair and the actual reoperation was 56 months(range 3 to 142 months). Seven patients(23.3%) had two or more previous operations. The indications for reoperations were true aneurysm in 7 patients(23.3%), prosthetic valve endocarditis in 6(20%), false aneurysm in 5(16.7%), paravalvular leak associated with Behcet's disease in 4(13.3%), malfunction of prosthetic aortic valve in 4(13.3%), aortic dissection in 3(10%), and annuloaortic ectasia in 1(3.3%). The principal reoperations performed were aortic root replacement in 17 patients(56.7%), replacement of the ascending aorta in 8(26.7%), aortic and mitral valve replacement with reconstruction of fibrous trigone in 2(6.6%), patch aortoplasty in 2(6.6%), and aortic valve replacement after Bentall operation in 1 (3.3%). The cardiopulmonary bypass was started before sternotomy in 7 patients and the hypothermic circulatory arrest was used in 16(53.3%). The mean time of circulatory arrest, total bypass, and aortic crossclamp were 20$\pm$ 12 minutes, 228$\pm$56 minutes, and 143$\pm$62 minutes, respectively Result: There were three early deaths(10%). The postoperative complications were reoperation for bleeding in 7 patients(23.3%), cardiac complications in 5(16.7%), transient acute renal failure in 2(6.6%), transient focal seizure in 2(6.6%), and the others in 5. The mean follow-up was 22.8 $\pm$20.5 months. There were two late deaths(7.4%). The actuarial survival was 92.6$\pm$5.0% at 6 years. One patient required reoperation for complication of reoperation on the ascending aorta and aortic root(3.7%). The 1- and 6-year actuarial freedom from reoperation was 100% and 83.3$\pm$15.2%, respectively. One patient with Behcet's disease are waiting for reoperation due to false aneurysm, which developed after aortic root replacement with homograft. There were no thromboembolisms or anticoagulant related complications. Conclusions: This study suggests that reoperations on the ascending aorta and aortic root can be performed with acceptable early mortality and morbidity, and adequate surgical strategies according to the pathologi conditions are critical to the prevention of the reoperation.