• Title/Summary/Keyword: Prosthetic complication

Search Result 101, Processing Time 0.022 seconds

Long Term Results of Rastelli Operation with a Mechanical Valve (기계 판막을 이용한 라스텔리 수술의 장기 성적)

  • Choi, Se-Hoon;Kim, Kwan-Chang;Kwak, Jae-Gun;Kim, Chang-Young;Lee, Jeong-Ryul;Kim, Yong-Jin;Rho, Joon-Ryang;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.900-905
    • /
    • 2006
  • Background: Homografts and bioprostheses are most commonly used for Rastelli operation in congenital heart disease, but the limited durability is responsible for multiple reoperations associated with increased morbidity This study evaluated long-term results after Rastelli operation with a mechanical valved conduit. Material and Method: A total of 20 patients underwent Rastelli operation with mechanical valved conduit from January 1990 to July 1992. Operative mortality was 1 of 20 patients, and a retrospective review of 19 patients(10 males, 9 females) was done. Initial diagnosis was congenitally corrected transposition of great arteries(cc-TGA, n=4), complete TGA (n=2), ventricular septal defect with pulmonary atresia(VSD with PA, n=9), truncus arteriosus(n=2), double outlet right ventricle with pulmonary stenosis(DORV with PS, n=2). The mean age at Rastelli operation was $4.6{\pm}3.4$ years, and mean follow-up period was $12.8{\pm}2.7$ years. Patients underwent Rastelli opearation using 16 CarboMedics mechanical valve, and 3 Bjork-Shiley mechanical valve($17{\pm}2$ mm). Result: There were 15 reoperations for failed mechanical valved conduit. The freedom from reoperation at 5 and 10 years was 53% and 37%. Most patients were received oral anticoagulation with warfarin, and maintained the international normalized ratio(INR) of 1.5 to 2.0. There was no anticoagulation or thromboembolism related complication. There was a significant difference in the causes of a conduit failure between early(within 3 years) and late(after 3 years) failure groups. The six patients reported early prosthetic valve failure, mainly due to valvular dysfunction by thrombosis or pannus formation. The other nine patients reported late prosthetic valve failure, mainly due to dacron conduit stenosis at anastomosis sites, whereas their valvar motion was normal except 1 patient. Conclusion: To avoid early prosthetic valve failure, strict anticoagulation therapy would be helpful. About the late development of obstructive intimal fibrocalcific peels within the Dacron conduit, an improvement of conduit material is necessary to reduce late prosthetic valve failure. In selected patients, the long term results were satisfactory.

Durability of Xenograft Cardiac Valves (이종조직 판막의 내구성)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.25 no.5
    • /
    • pp.494-503
    • /
    • 1992
  • The durability of the xenograft cardiac substitute valves is of a great concern on the clinical grounds. Four groups of tc tal and consecutive patients to the end of study operated on between 1976 and 1984 were Group ISM, 291 patients of MVR, ISA, 65 patients of AVR, and ISMA, 107 patients of MVR+AVR with the standard Ionescu-Shiley bovine pericardial valve, and H, 163 patients of valve replacement with the Hancock porcine aortic vlave. Operative mortality was 5.2%[ISM], 10.8%[ISA], 7.5%[ISMA] and 6.1%[H]. Early survivors were followed up for a total of 1148.3 patient-years[pt-yrs] [ISM], 271.2 pt-yrs [ISA], 488.1 pt-yrs[ISMA] and 822.9 pt-yrs[H]. Linearized late mortality was 2.1% /pt-yr [ISM], 1.l%/pt-yr[ISA], 1.8%/pt-yr[ISMA] and 1.8% /pt-yr[H]. Thromboembolic complication was experienced at the linearized rate of 1.045% /pt-yr [ISM], 1.475%/pt-yr[ISA], 0.615%/pt-yr[ISMA] and 1.822%/pt-yr[H], and bleeding complication at the rate of 0.871% /pt-yr[ISM], 0.63% /pt-yr[ISA], 0.205% /pt-yr [ISMA] and 0.729%a /pt-yr[H], respectively. Prosthetic valve endocarditis occurred at the rate of 0.610% /pt-yr[ISM], 1.475% /pt-yr[ISA], 1.639% /pt-yr[ISMA] and 0.972% /pt-yr[H]. The linearized annual incidence of primary tissue failure was 1.655%/pt-yr[ISM], l. 475%/pt-yr[ISA], 1.639% /pt-yr[ISMA], 2.187% /pt-yr[H] and 1.785% /pt-yr[Group HM : MVR with Hancock valve]. The incidence of tissue failure was significantly high in the patients younger than 30 years of age compared with the older patients. The actuarial survival was 87.7$\pm$2.5% at 10 years[ISM], 94.3$\pm$3.2% at 11 years[ISA], 89.6$\pm$3.4% at 10 years[ISMA] and 81.3$\pm$6.6% at 12 years[HM], The freedom from thromboembolism was 93.2$\pm$2.0% at 10 years[ISM], 90.6$\pm$4.6% at 11 years[ISA], 95.8$\pm$2.6% at 10 years[ISMA] and 80.9$\pm$11.1% at 12 years[HM], And, the freedom from primary tissue failure was 84.2$\pm$3.8% and 28.1$\pm$23.0% at 9 and 10 years[ISM], 60.4$\pm$16.9% at 11 years[ISA], 62.3$\pm$12.7 at 10 years[ISMA] and 65.6$\pm$9.8% at 12 years[HM]. In conclusion, the standard Ionescu-Shiley and the Hancock bioprosthetic valves are excellent in their antithrombogenicity and long-term survival. However, the features of the structural failure with the prolonged follow-up beyond 10 years appear to be guarding, and the clinical indications of these bioprostheses seem to be quite limited.

  • PDF

Complication rates and patient satisfaction with removable dentures

  • Bilhan, Hakan;Erdogan, Ozge;Ergin, Selen;Celik, Melahat;Ates, Gokcen;Geckili, Onur
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.2
    • /
    • pp.109-115
    • /
    • 2012
  • PURPOSE. The purpose of this clinical study was to evaluate the frequency and type of prosthetic complications in relation to type and properties of removable dentures and to investigate the influence of these complications and several data about the existing dentures on patient satisfaction. MATERIALS AND METHODS. Ninety nine patients (44 males and 55 females) wearing removable dentures have been included in the study. The complications of the patients were recorded; patient satisfaction was determined with a Visual Analog Scale (VAS) and the relationship of complications and patient satisfaction with several data about the dentures such as denture age, type of denture, centric relation and vertical dimension was investigated. Kruskal Wallis, Mann Whitney U and Chi square tests were used for statistical analyses. The results were evaluated statistically at a significance level of $P$ <.05. RESULTS. Need for addition of artificial teeth for dentures with correct centric relations was found to be significantly lower than dentures with wrong centric relations ($P$ <.01). Loss of retention, ulcerations and high vertical dimension affected the VAS chewing ability scores negatively and ulcerations affected the VAS phonation scores negatively ($P$ <.05). CONCLUSION. Considering the results of this study, it can be concluded that loss of retention, ulcerations and high vertical dimension caused patient dissatisfaction. Additionally, dentures with wrong centric relations caused need for addition of artificial teeth.

Literature review and case report of prosthetic rehabilitation with telescopic denture (이중관 의치에 관한 문헌 고찰 및 증례 보고)

  • Sung, Han-Gyul;Jo, Eun-Hye;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.308-316
    • /
    • 2018
  • Telescopic denture has advantages such as transfer the occlusal force to the long axis of the abutment, easiness of oral hygiene management, increase of retention and stability, splint effect due to secondary fixation between abutments and have been reported a higher success rates than conventional removable partial denture (RPD). However, there are disadvantages such as complex laboratory procedures, long treatment periods and high costs, and high incidence of complications. This clinical report describes two cases, a 4-point supported telescopic denture using telescopic crown and a 2-point supported telescopic denture using conical crown with functionally satisfactory results. Frequent complications of telescopic denture, which are reported in various literature were reviewed. Clinical and laboratory procedures were performed in consideration of complications that reported.

Isolated Aortic Valve Replacement with the Ionescu-Shiley Xenograft Valve (대동맥판 치환수술의 임상성적)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.18 no.1
    • /
    • pp.46-53
    • /
    • 1985
  • A single aortic valve replacement using the lonescu-Shiley bovine pericardial xenograft valve was performed in 66 consecutive patients during the period from February, 1979 to June, 1984. They were 49 males and 17 females with ages ranging from 9 to 61 [mean, 31.113.1] years, and 9 of them were children younger than 15 years of age. Twenty-seven patients [40.9%] required the combined operative procedures to either other valvular lesions or congenital defects. There were 9 early deaths within 30 days of surgery [operative mortality rate, 13.6%] and 2 late deaths thereafter [late mortality rate, 3.0%; or 1.75%/patient-year]. The 57 early survivors were followed for a total duration of 114.2 patient-years [mean, 24.016.0 months]. Four patients experienced thromboembolic complication with no death [3.50%/patient-year]; one died from intracranial bleeding related to anticoagulation [0.88%/patient-year]; one recovered from prosthetic valve endocarditis [0.88%/patient-year]; and four developed aortic regurgitant murmur with none or minimal cardiac symptoms and they were classified into cases of tissue valve failure [3.50%/patient-year]. The actuarial survival rate was 82.34.7% at 6 years, and the actuarial probabilities of freedom from thromboembolism and valve failure were 93.33.9% and 89.15.8% at postoperative 6 years respectively Symptomatic improvement was excellent in most late survivors at the follow-up end with the mean of NYHA Classes of 1.040.19 while the one was 2.290.67 at the time of operation. Excluding the higher operative mortality rates, these clinical results are fully comparable with the ones of reports from the major institutions using the porcine aortic or the bovine pericardial tissue valves and warrants the continued use of the xenograft valve in the aortic position. The importance of more detailed preoperative evaluation of the myocardial function and the need of improved myocardial preservation during surgery for the improved early clinical results were discussed.

  • PDF

A Convergence Study on the Characteristics of Length of Hospital Stays of Injured and Traumatic Death Patients - Based on the Korea National Hospital Discharge Injury Survey Data (손상 및 외상 사망 환자의 재원일수 특성에 관한 융합 연구 -퇴원손상심층조사자료를 중심으로)

  • Song, Yu-Rim;Lee, Moo-Sik;Kim, Doo-Ree;Kim, Kwang-Hwan
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.5
    • /
    • pp.87-96
    • /
    • 2017
  • This study was carried out to provide basic data for prevention of death from injuries and traumas by analyzing the characteristics of length of hospital stay of patients with injuries and traumas, utilizing in-depth investigation data of discharged injuries. The study subjects were 233 patients discharged from January 1 to December 31 in 2014 whom the final treatment result was 'death' and the main diagnosis were injuries and accidental external causes(S00-T98). According to the research findings, the length of hospital stay of females was longer than that of males. Based on the main diagnosis, the longest length of hospital stay had complication of other internal prosthetic devices, implants and grafts(T85). In conclusion, it is necessary to develop a policy to identify the factors affecting the length of hospital stays of patients and to manage them intensively.

Systematic Review and Comparative Meta-Analysis of Outcomes Following Pedicled Muscle versus Fasciocutaneous Flap Coverage for Complex Periprosthetic Wounds in Patients with Total Knee Arthroplasty

  • Economides, James M.;DeFazio, Michael V.;Golshani, Kayvon;Cinque, Mark;Anghel, Ersilia L.;Attinger, Christopher E.;Evans, Karen Kim
    • Archives of Plastic Surgery
    • /
    • v.44 no.2
    • /
    • pp.124-135
    • /
    • 2017
  • Background In cases of total knee arthroplasty (TKA) threatened by potential hardware exposure, flap-based reconstruction is indicated to provide durable coverage. Historically, muscle flaps were favored as they provide vascular tissue to an infected wound bed. However, data comparing the performance of muscle versus fasciocutaneous flaps are limited and reflect a lack of consensus regarding the optimal management of these wounds. The aim of this study was to compare the outcomes of muscle versus fasciocutaneous flaps following the salvage of compromised TKA. Methods A systematic search and meta-analysis were performed to identify patients with TKA who underwent either pedicled muscle or fasciocutaneous flap coverage of periprosthetic knee defects. Studies evaluating implant/limb salvage rates, ambulatory function, complications, and donor-site morbidity were included in the comparative analysis. Results A total of 18 articles, corresponding to 172 flaps (119 muscle flaps and 53 fasciocutaneous flaps) were reviewed. Rates of implant salvage (88.8% vs. 90.1%, P=0.05) and limb salvage (89.8% vs. 100%, P=0.14) were comparable in each cohort. While overall complication rates were similar (47.3% vs. 44%, P=0.78), the rates of persistent infection (16.4% vs. 0%, P=0.14) and recurrent infection (9.1% vs. 4%, P=0.94) tended to be higher in the muscle flap cohort. Notably, functional outcomes and ambulation rates were sparingly reported. Conclusions Rates of limb and prosthetic salvage were comparable following muscle or fasciocutaneous flap coverage of compromised TKA. The functional morbidity associated with muscle flap harvest, however, may support the use of fasciocutaneous flaps for coverage of these defects, particularly in young patients and/or high-performance athletes.

Experience with Rastelli Procedure in the Repair of Congenital Heart Diseases (Rastelli 술식의 임상경험;72례)

  • 백희종
    • Journal of Chest Surgery
    • /
    • v.25 no.11
    • /
    • pp.1327-1336
    • /
    • 1992
  • Between Jan. 1986 and Aug. 1992. 72 patients underwent Rastelli procedure. There were 43 male and 29 female, aged 46 days to 16 years [mean age, 5.2 years] with 18 patients less than 2 years of age. All patients had complex defect, 27 pulmonary atresia with ventricular septal defect, 18 corrected transposition of great arteries with pulmonary atresia or punmonary stenosis, 10 truncus arteriosus, 10 double outlet right ventricle with pulmonary atresia or stenosis, 7 complete transposition of great artersia with pulmonary atresia or pulmonary stenosis. The types of extracardiac valved conduit used were prosthetic valve[n=47, 24 car-bomedics, 19 Ionescu-Shiley, 4 Bjork-shiley] and hand-made trileaflet valve using pericardium. [n=23, 20 bovine pericardium, Z autologous pericardium, 1 equine pericardium] The mean size of valved cinduit was 5.25mm larger in diameter than the size of main pulmonary artery. [normalized to the patient`s body surface area] There were 17 hospital death[24%] and 4 late deaths[5.6%]. Postoperative complication rate was 38.9%a, none of which was conduit-related. All patients were followed pos-toperatively for 1 to 73 months. [mean 25.8 months] During follow-up period, reoperation was done in 6 patients due to stenosis of valved conduit. Mean interval between intial repair and reoperation was 20.3 months. In our experience, li recently extracardaic valved conduits between right ventricle [or pulmonary ventricle] and pulmonary artery were inserted with increasing frequency in infants less than 2 year, but hospital mortality was decreased, 2] Risk of reoperation due to conduit stenosis is low, so that the effect of graft failure on overall survival is minimized. 3] Nevertheless, because any type of extracardaic valved conduit is not ideal in children, we recommended that Lecompte should be done if cardiac anatomy is permitted.

  • PDF

Revisiting root resection treatment in the age of dental implants (임플란트 시대의 치근절제술의 다양한 활용증례 및 부가적 효용)

  • Joo, Ji-Young;Kwon, Eun-Young;Lee, Ju-Youn
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.232-239
    • /
    • 2016
  • Purpose: In this paper, we introduce a wide clinical application of root resection therapy and additional benefits on the next prosthetic or dental implant treatment procedures in the age of dental implants. Materials and Methods: Additional clinical benefits of root resection were monitored by clinical and radiographic evaluation. Results: No complication was reported in all the cases, and the favorable results of root resection were maintained for long period. Conclusion: In compromised multirooted teeth, variety clinical treatment modality should be considered for enhancing the reconstruction of alveolar ridge around root resected in preparation for next implantation.

A Clinical Experience of Mitral Valve Replacement (승모판막 치환술의 임상적 고찰)

  • 김종원;황수희
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1347-1353
    • /
    • 1996
  • To assess the long-term results of mitral valve replacement, we reviewed our cases of the 374 patients undergoing mitral valve replacement between March 1982 to February 1992 There were 159 male and 215 female and mean age was 37.8 years. There were 24 hospital deaths(6.4%);the most commonly from low cardiac output syndrome(12 deaths). We used 314 mechanical valves and 60 tissue valves. Most of all were anticoagulated with coumadin maintaining target level of 1.5~3.0 INR of prothrombin time. Follow up was 94% complete(2270 patient-years). There were 12 late deaths 3 due to hemorrhage, 3 due to cerebral embolism and 6 from Overall actuarial survival including hospital mortality, was 82.3% after 10 years of operation Linealized rates of late complication events are follows thromboembolism, 1.3% per patient-year; anti coagulant related hemorrhage, 0.5% per patient year. We analyzed the factors of favorable effect to postoperative course were preoperat ve clinical status including NYHA class, first operation, valve apparatus preservating operation technique, not biggest size of prosthetic valve.

  • PDF