• 제목/요약/키워드: Prosthetic

검색결과 1,213건 처리시간 0.027초

유동모드 MR 댐퍼가 구비된 대퇴의족의 설계 및 해석 (Design and Analysis of Above Knee Prosthetic Leg Using MR Damper)

  • 박진혁;강제원;최승복
    • 한국소음진동공학회논문집
    • /
    • 제26권2호
    • /
    • pp.165-171
    • /
    • 2016
  • A prosthetic knee for above-knee (AK) amputee is categorized into passive and active type. The passive prosthetic knee is generally made by elastic material. Although AK amputee can easily walk by using passive prosthetic leg, knee joint motions are not similar to ordinary persons. The active prosthetic leg can control the knee angle owing to the actuator and microprocessor. However, the active type is not cost-effective and the stability may be lost due to the malfunction of sensors. In order to resolve these disadvantages of passive and active type, a semi-active prosthetic knee which can control the knee angle is proposed in this work. The proposed semi-active one requires a less input energy but provides active type performance. In order to achieve this goal, in this work, a semi-active prosthetic knee using magneto-rheological (MR) damper for AK amputees is designed. The MR damper can support the weight of body by using less energy than actuator of active prosthetic. It can control knee angle by inducing the magnetic field at the time of stance phase. This salient characteristic is evaluated and presented in this work.

Role of Muscle Free Flap in the Salvage of Complicated Scalp Wounds and Infected Prosthetic Dura

  • Han, Dae Hee;Park, Myong Chul;Park, Dong Ha;Song, Hyunsuk;Lee, Il Jae
    • Archives of Plastic Surgery
    • /
    • 제40권6호
    • /
    • pp.735-741
    • /
    • 2013
  • Background The prosthetic dura is an essential element in the protection of the cranial parenchyma and prevention of cerebrospinal fluid leakage. Although prosthetic dura are widely used in neurosurgery, they occasionally provoke infection, which can be a major concern after neurosurgical treatment. However, removal of the prosthetic dura carries a risk of brain parenchyma injury and cerebrospinal fluid leakage. The salvage of infected prosthetic dural material has not been adequately addressed in the literature. In this study, we demonstrate the value of the combination of a meticulous surgical debridement of necrotic tissue and simultaneous muscle free flap for intractable postoperative epidural abscess without removal of the infected prosthetic dura. Methods Between 2010 and 2012, we reviewed the data of 11 patients with persistent infection on the prosthetic dura. The epidural infections each occurred after a neurosurgical procedure, and there was soft tissue necrosis with the disclosure of the underlying prosthetic dura and dead bone around the scalp wound. To salvage the infected prosthetic dura, meticulous debridement and a muscle free flap were performed. Results All 11 patients experienced complete recovery from the complicated wound problem without the need for further surgical intervention. No signs of prosthetic dural infection were observed during the mean follow-up period of 11 months. Conclusions The combination of a meticulous surgical debridement and coverage with a muscle free flap is an effective treatment for salvage of infected prosthetic dura.

3D프린팅을 이용한 사용자 맞춤형 의수 개발 (Development of Customized Prosthetic Hand Using 3D Printing)

  • 문미경
    • 융합신호처리학회논문지
    • /
    • 제19권3호
    • /
    • pp.110-117
    • /
    • 2018
  • 의수나 의족장치 개발은 전 세계적으로 꾸준히 이루어지고 있으며, 사람의 손과 똑같이 만들어 내거나 감각을 느끼게 하는 것은 힘들겠지만, 물건을 집거나 몇 가지 움직임을 마음먹은 대로 할 수 있다면 절단 장애인들에게는 큰 도움이 될 것이다. 3D프린팅 기술의 발달로 저렴한 의수개발이 가능해졌으며, 이러한 추세에 맞추어 개인맞춤형 의수를 비슷한 가격에 개발할 수 있다면 활용도 및 보급률이 훨씬 높아질 것이다. 본 논문에서는 3D프린팅을 이용하여 사용자 맞춤형 의수를 개발하는 방법에 대해 기술한다. 이를 위해 의수 외형 모델링의 변형수치를 가변값으로 추출하고, 의수 동작을 제어하는 기능을 소프트웨어 디자인 패턴을 이용하여 설계한다. 이를 통해 의수를 필요로 하는 사람들이 각자 원하는 자신만의 의수를 빠르고 저렴한 가격에 갖출 수 있도록 한다.

심초음파도를 이용한 대동맥인공판막치수 예 (Two-Dimensional Echocardiographic Prediction of Prosthetic Aortic Valve Size)

  • 박창권
    • Journal of Chest Surgery
    • /
    • 제20권4호
    • /
    • pp.655-658
    • /
    • 1987
  • Aortic annulus size was measured by two-dimensional echocardiography [2DE] in 29 patients undergoing aortic valve replacement or double valve replacement in order to predict prosthetic aortic valve size. Fifteen patients had aortic stenoinsufficiency, eleven had aortic insufficiency, and three had aortic stenosis. 2DE measurements of aortic annulus diameter, as determined from the parasternal long-axis view, demonstrated a high correlation with actual prosthetic valve size implanted at surgery [r=0.85, p<0.05]. 2DE exactly predicted actual prosthetic valve size in 8 of 29 patients [27.6%], was within 1mm of prosthetic valve size in 11 of 29 patients [37.9%], was within 2mm of prosthetic valve size in 8 of 29 patients, and was within 3mm of prosthetic valve size in 2 patients.

  • PDF

근전도 패턴 인식 및 분류 기반 다자유도 전완 의수 개발 (Development of Multi-DoFs Prosthetic Forearm based on EMG Pattern Recognition and Classification)

  • 이슬아;최유나;양세동;홍근영;최영진
    • 로봇학회논문지
    • /
    • 제14권3호
    • /
    • pp.228-235
    • /
    • 2019
  • This paper presents a multiple DoFs (degrees-of-freedom) prosthetic forearm and sEMG (surface electromyogram) pattern recognition and motion intent classification of forearm amputee. The developed prosthetic forearm has 9 DoFs hand and single-DoF wrist, and the socket is designed considering wearability. In addition, the pattern recognition based on sEMG is proposed for prosthetic control. Several experiments were conducted to substantiate the performance of the prosthetic forearm. First, the developed prosthetic forearm could perform various motions required for activity of daily living of forearm amputee. It was able to control according to shape and size of the object. Additionally, the amputee was able to perform 'tying up shoe' using the prosthetic forearm. Secondly, pattern recognition and classification experiments using the sEMG signals were performed to find out whether it could classify the motions according to the user's intents. For this purpose, sEMG signals were applied to the multilayer perceptron (MLP) for training and testing. As a result, overall classification accuracy arrived at 99.6% for all participants, and all the postures showed more than 97% accuracy.

경중족 절단 환자의 의족지 착용에 따른 족저압력 분포 특성 (Characteristics of Foot Pressure Distribution with or without Partial Prosthetic Foot in Transmetartarsal Amputee)

  • 성우성;양희승;성홍기;김학준
    • 대한족부족관절학회지
    • /
    • 제12권1호
    • /
    • pp.41-46
    • /
    • 2008
  • Purpose: This study was designed to evaluate characteristics of foot pressure distribution with or without partial prosthetic foot in transmetatarsal amputee. Materials and Methods: The subjects were 9 transmetatarsal amputees. Foot pressures were measured at hallux, the $1^{st}-5^{th}$ metatarsal head (MTH), mid-foot, condyle area by F-scan system in amputated or contralateral foot during active walking. Results: In amputated foot, mean peak pressure was greatest in midfoot without prosthetic foot but it was greatest in hindfoot with prosthetic foot. In unaffected foot, although mean peak pressure was higher in hallux, and $1-5^{th}$ MTH compared to amputated foot, it was greatest in hind foot both with and without prosthetic foot. However, in unaffected foot, mean peak pressure significantly decreased in hallux and $5^{th}$ MTH after wearing the prosthetic foot. There was a significant difference in mean peak pressure in hallux and $5^{th}$ MTH between amputated and unaffected foot after wearing prosthetic foot. However, other region had no significant difference with or without prosthetic foot between feet. Conclusions: The use of partial prosthetic foot tends to shift weight bearing from the heel area to forefoot and could significantly reduce hind foot peak pressure and redistributed to peak pressure. The partial prosthetic foot can also offer the peak pressure to reduction both amputated foot and unaffected foot and help to toe off during walking.

  • PDF

인공심장판막의 재치환수술: 7례 보 (Re-replacement of prosthetic heart valves: report of 7 cases)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • 제17권1호
    • /
    • pp.3-11
    • /
    • 1984
  • Prosthetic valve replacement has resulted in marked improvement in the functional status of many patients with valvular heart disease. But valve failure from various causes has necessitated re-replacement of prosthetic valve in some of these patients. This selective group of patients has many inherent problems. This report presents our experience with seven patients who received re-replacement of prosthetic valve in the Seoul National University Hospital from 1981, to 1983. The patients included one woman and six men in the range of 9 and 49 years old. As the first valve operations, there were five MVR using tissue valves, one DVR [Bjork-Shiley and Ionescu-Shiley valve] and one case of modified Bentall operation with composite graft [Ionescu-Shiley valve]. Reoperations on prosthetic valve failure were performed 17 to 54 months after the first operation [mean 34 months]. Amon8 seven patients, there were two cases of prosthetic valve endocarditis and five cases of primary tissue failure. Gross calcification of the xenograft was found in two children with Ionescu-Shiley valve. All except one had relatively successful operative results. The unsuccessful one died intraoperatively from low output syndrome.

  • PDF

인공심장판막의 재치환술 5례 보고 (Replacement of prosthetic heart valves Report of 5 cases)

  • 신제균
    • Journal of Chest Surgery
    • /
    • 제18권4호
    • /
    • pp.655-662
    • /
    • 1985
  • From January 1985 to July 1985, prosthetic heart valves were replaced in 5 patients at Keimyung University Dongsan Medical Center. The patients included three women and two men ranging in age from 22 to 41 years. Three mitral valve replacements, one aortic valve replacement and one double valve replacement [mitral and aortic valve replacement] were done at the first valve operations. Reoperation were performed 2 to 76 months after the first operations, Prosthetic valve endocarditis occurred in 3 patients, early in one and late in two and primary valve failure occurred in 2 patients. In operative findings, vegetation in prosthetic valve endocarditis and calcification in primary valve failure were found. All except one had relatively successful operative results. One died of early fungal prosthetic valve endocarditis due to relapsed prosthetic valve endocarditis with heart failure and block.

  • PDF

치아상실 환자들의 보철치료 전과 후의 불안 및 우울에 영향을 미치는 요인 (Influencing factors on anxiety and depression before and after dental prosthetic treatment in the patients)

  • 권선화;김한곤
    • 한국치위생학회지
    • /
    • 제15권5호
    • /
    • pp.777-786
    • /
    • 2015
  • Objectives: The purpose of the study was to investigate the influencing factors on anxiety and depression before and after prosthetic treatment in the patients. Methods: A self-reported questionnaire was completed by 248 patients with tooth loss and over 20 years old. The questionnaire was carried out before and after oral examination and dental prosthetic treatment from July to December, 2013. The study instruments included Beck's anxiety inventory and self-rating depression scale by Zung. The questionnaire was adapted and modified from Kwon's anxiety inventory and Lee's depression scale. Results: While the anxiety level increased from 69.4% to 78.2% in the normal people, the depression level changed from 53.2% to 64.1% in the normal people. The gender variable had a positive effect on anxiety and depression while educational level had a negative effect on them. The dental fear was closely related to anxiety and depression before and after the prosthetic treatment. The entire body health perception showed a negative effect on anxiety and depression. The distrust towards the dentist had an influence on the anxiety and depression in the prosthetic patients. Conclusions: The influencing factors on anxiety and depression in the prosthetic patients included gender, dental fear, entire body perception, and distrust towards the dentist.