• Title/Summary/Keyword: Prosthesis loosening

Search Result 68, Processing Time 0.03 seconds

Complications of reverse shoulder arthroplasty: a concise review

  • Kim, Su Cheol;Kim, Il Su;Jang, Min Chang;Yoo, Jae Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.1
    • /
    • pp.42-52
    • /
    • 2021
  • Reverse shoulder arthroplasty is an ideal treatment for glenohumeral dysfunction due to cuff tear arthropathy. As the number of patients treated with reverse shoulder arthroplasty is increasing, the incidence of complications after this procedure also is increasing. The rate of complications in reverse shoulder arthroplasty was reported to be 15%-24%. Recently, the following complications have been reported in order of frequency: periprosthetic infection, dislocation, periprosthetic fracture, neurologic injury, scapular notching, acromion or scapular spine fracture, and aseptic loosening of prosthesis. However, the overall complication rate has varied across studies because of different prosthesis used, improvement of implant and surgical skills, and different definitions of complications. Some authors included complications that affect the clinical outcomes of the surgery, while others reported minor complications that do not affect the clinical outcomes such as minor reversible neurologic deficit or minimal scapular notching. This review article summarizes the processes related to diagnosis and treatment of complications after reverse shoulder arthroplasty with the aim of helping clinicians reduce complications and perform appropriate procedures if/when complications occur.

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE BONE ANCHORED FIXED PROSTHESIS ACCORDING TO THE LOAD CONDITION (골유착 고정성 보철물 하에서 하중조건에 따른 삼차원 유한요소법적 분석)

  • Yang, Soon-Ik;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.780-806
    • /
    • 1995
  • The purpose of this study was to describe the application of 3D finite element analysis to determine resultant stresses on the bone anchored fixed prosthesis, implants and supporting bone of the mandible according to fixture numbers and load conditions. 4 or 6 fixtures and the bone anchored fixed prosthesis were placed in 3D finite element mandibular arch model which represents an actual mandibular skull. A $45^{\circ}$ diagonal load of 10㎏ was labiolingually applied in the center of the prosthesis(P1). A $45^{\circ}$ diagonal load of 20㎏ was buccolingually applied at the location of the 10mm or 20mm cantilever posterior to the most distal implant(P2 or P3). The vertical distribution loads were applied to the superior surfaces of both the right and the left 20mm cantilevers(P4). In order that the boundary conditions of the structure were located to the mandibular ramus and angle, the distal bone plane was to totally fixed to prevent rigid body motion of the entire model. 3D finite element analysis was perfomed for stress distribution and deflection on implants and supporting bone using commercial software(ABAQUS program. for Sun-SPARC Workstation. The results were as follows : 1. In all conditions of load, the hightest tensile stresses were observed at the metal lates of prostheses. 2. The higher tensile stresses were observed at the diagonal loads rather than the vertical loads 3. 6-implants cases were more stable than 4-implants cases for decreasing bending and torque under diagonal load on the anterior of prosthesis. 4. From a biomechanical perspective, high stress developed at the metal plate of cantilever-to-the most distal implant junctions as a consequence of loads applied to the cantilever extension. 5. Under diagonal load on cantilever extension, the 6-implants cases had a tendency to reduce displacement and to increase the reaction force of supporting point due to increasing the bendign stiffness of the prosthesis than 4-implants cases. 6. Under diagonal load on cantilever extension, the case of 10mm long cantilever was more stable than that of 20mm long cnatilever in respect of stress distribution and displacement. 7. When the ends of 10mm or 20mm long cantilever were loaded, the higher tensile stress was observed at the second most distal implant rather than the first most distal implant. 8. The 6-implants cases were more favorable about prevention of screw loosening under repeated loadings because 6-implants cases had smaller deformation and 4-implants cases had larger deformation.

  • PDF

The Effects of Screw Retained Prosthesis Misfit & Cantilever on Stress Distribution in Bone Around the Implant (나사유지형 임플란트 고정성 보철물의 적합도와 캔틸레버가 지지골조직의 응력분산에 미치는 영향)

  • Lee, Jae-In;Kim, Tae-Young;Cho, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.224-235
    • /
    • 2013
  • A passively fitting prosthesis is an essential prerequisite to attain long-lasting success and maintenance of osseointegration. However, true "passive fit" can not be achieved with the present implant-supported prosthesis fabrication protocol. Many clinical situations are suitably treated with cantilevered implant-supported fixed restorations. The purpose of this study was to compare the stress distribution pattern and magnitude in supporting tissues around ITI implants with cantilevered, implant-supported, screw-retained fixed prosthesis according to the fitness of superstructures. Photoelastic model was made with PL-2 resin (Measurements, Raleigh, USA) and three ITI implants (${\phi}4.1{\times}10mm$) were placed in the mandibular posterior edentulous area distal to the canine. Anterior and posterior extended 4-unit cantilevered FPDs were made with different misfit in the superstructures. 4 types of prosthesis were made by placing a $100{\mu}m$ gap between the abutment and the crown on the second premolar and/or the first molar. Photoelastic stress analysis were carried out to measure the fringe order around the implant supporting structure under simulated loading conditions (30 lb).

Biomechanical considerations for the screw of implant prosthesis: A literature review (임플란트 나사에 적용되는 생역학적 원리: 문헌고찰)

  • Im, So-Min;Kim, Dae-Gon;Park, Chan-Jin;Cha, Min-Sang;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.61-68
    • /
    • 2010
  • Purpose: This article attempted to determine the factors affecting the preload and screw loosening. Methods: Available clinical studies from 1981 to 2008 from the PUBMED that presented screw loosening data and review articles regarding screw joint stability were evaluated. Eleven studies dealing the biomechanical principles of the screw mechanics were reviewed. Moreover, the results of our data were included. Results: The frequency of screw loosening was consequently reduced due to the advancement in torque tightening with torque wrench, screw material, coating technique for reducing the frictional force, and thread design, etc. If preload in the screw falls below a critical level, joint stability may be compromised, and the screw joint may fail clinically. The types of fatigue failure of screw were divided to adhesive wear, plastic deformation, and screw fracture. Conclusion: An optimum preload is essential to the success of the implant-abutment complex. To maintain optimum preload, using a torque wrench and re-tightening at recall time were needed.

Tribology for All-Ceramic Joint Prostheses

  • Ikeuchi, K.;Kusaka, J.;Yoshida, H.
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 2000.06a
    • /
    • pp.165-177
    • /
    • 2000
  • Ceramic on ceramic total hip prostheses are developed to apply to young patients because lifetime of polyethylene joint prostheses is limited by loosening due to biological response. As mating faces of all-ceramic joint must be highly conformed to reduce stress concentration, wear properties of flat surfaces are investigated in this study. Through wear tests at 2 MPa of contact pressure and 36 mm/s of sliding velocity, alumina and silicon carbide keep low wear rate, high hardness and smooth surface. Soft surface film was detected after the test in bovine serum. This suggests that boundary lubrication is effective to reduce wear in all-ceramic joint.

  • PDF

Re-establishment of occlusal plane in a patient with a failed implant prosthesis (실패한 임플란트 보철수복물을 가진 환자의 교합평면 재설정)

  • Kang, Hyeon-Goo;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.141-153
    • /
    • 2018
  • A non-physiological occlusal plane caused by continuous tooth loss, occlusal wear, and failure of a prosthesis may result in an unattractive appearance and functional problems, such as reduced masticatory efficiency and occlusal interference. Therefore, when undertaking prosthetic treatment for edentulous patients or patients with a collapsed occlusal plane, it is important to establish an occlusal plane that is compatible with masticatory function. The patient in this case report had undergone restoration of a completely edentulous maxilla using an implant-supported fixed prosthesis. On follow-up examination in the following 6 years, mechanical complications were observed in the existing implant prosthesis, including porcelain chipping, occlusal wear, and screw loosening. Moreover, due to occlusal wear and supraeruption of the opposing anterior teeth, as well as loss of some posterior teeth, the occlusal plane had collapsed. Following diagnosis, the patient underwent full mouth rehabilitation, involving additional implant installation in edentulous sites, recreation of the existing prosthesis, and prosthetic restoration of all remaining teeth.

Outcome of Tumor Prosthetic Reconstruction in Osteosarcoma Patient (골육종 환자에서 종양 대치물을 이용한 재건술의 치료결과)

  • Kim, Jae-Do;Kim, Cheung-Kue;Chung, So-Hak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.17 no.2
    • /
    • pp.79-86
    • /
    • 2011
  • Purpose: Modular tumor prosthesis is the most popular recontructive modality after resection of malignat tumor in extremity. Complications and survival of tumor prosthesis reconstruction are well-known. however, reports on the long-term outcome of tumor prosthesis in osteosarcoma patientss are scarece. Materials and Methods: In 158 cases as diagnosed as osteosarcoma from feburary 1989 to December 2006 in a single cancer center. We retrospectively reviewd 48 osteosarcoma patients who under went tumor prosthetic reconstruction. Mean follow up preiod was 75.6 months (range; 60 to 179 months). There were 28 males, 20 females and mean age was 22.4 years (range; 11-71). Pathologic subtypes were conventional central osteosarcoma in 46 cases and periosteal in 2 cases. The location of the tumor was proximal tibia (26 cases), distal femor (20 cases), femor diaphysis (1 case), and tibia diaphysis (1 case). In 41 cases built-up-type tumor prosthesis have been used and 7 cases expansion-type tumor prosthesis have been used. We used Musculoskeletal tumor society (MSTS) grading system to asses post operation function, and we analyzed survival rate of patient and tumor prosthesis and complication. Results: The overall survival rate was 77.7% and disease free survival rate was 68.9%. The survival rate of tumor prosthesis was 73%, in last follow up tumor prosthesis has been removed in 12 cases. All of them, 17 complications occurred, which included infection in 16 cases, Periprosthetic Fracture and Loosening of tumor prosthesis in 4 cases, articular instability in 4 cases. MSTS functional score was 74.1% in post operation. Conclusion: In long term follow up result, Primary tumor prosthesis -a reconstruction method after a wide extensional resecion of a bone tumor- can be a effective treatment method in asepect of survival rate, functional assesment and complication.

A Study of mechanical properties of oxide layer removed Co-Cr-Mo abutments

  • Ryu, Jae-ho;Huh, Jung-Bo;Ro, Jung-Hoon;Yun, Mi-Jung;Jeong, Chang-Mo
    • The Journal of the Korean dental association
    • /
    • v.53 no.11
    • /
    • pp.804-816
    • /
    • 2015
  • PURPOSE: The aim of this study was to evaluate the influence of the oxide layer removal process in the Co-Cr-Mo (CCM) abutment after casting procedure on the prosthesis settlement and screw stability. MATERIALS AND METHODS: CCM abutments of four different interface conditions (CCM-M; machined, CCM-O; oxide layer formed, CCM-B; blasted, CCM-P; polished after blasted) and gold abutment (Gold-C; Cast with type III Gold alloy) were used. The initial settling values of abutments were evaluated according to the difference of implant-abutment length when the tightening torques were applied at 5 Ncm and 30 Ncm, and the settling values of abutments caused by loading were evaluated according to the difference of implant-abutment length before and after loading with 250 N, 100000 cycle. The loss ratios of removal torque for abutment screws were evaluated according to the difference in value of removal torques under 30 Ncm tightening torque applied before and after cyclic loading. RESULTS: The CCM-P and CCM-B group showed a higher initial settling value compared with the Gold-C group (P<.05), while the Gold-C group showed the highest settling values caused by loading (P<.05) and no significant differences were observed for between CCM groups (P>.05). The loss ratio of removal torque values for the CCM-B, CCM-P groups did not differ significantly from that of the Gold-C group (P>.05). CONCLUSION: Even though the oxide layer was removed by different methods, CCM abutment with internal conical connection structure showed lower abutment settling and similar screw loosening after cyclic loading compared with gold abutment.

Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review

  • Kim, Ha-Young;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.325-332
    • /
    • 2014
  • PURPOSE. The aim of this review was to analyze the evaluation criteria on mandibular implant overdentures through a systematic review and suggest standardized evaluation criteria. MATERIALS AND METHODS. A systematic literature search was conducted by PubMed search strategy and hand-searching of relevant journals from included studies considering inclusion and exclusion criteria. Randomized clinical trials (RCT) and clinical trial studies comparing attachment systems on mandibular implant overdentures until December, 2011 were selected. Twenty nine studies were finally selected and the data about evaluation methods were collected. RESULTS. Evaluation criteria could be classified into 4 groups (implant survival, peri-implant tissue evaluation, prosthetic evaluation, and patient satisfaction). Among 29 studies, 21 studies presented implant survival rate, while any studies reporting implant failure did not present cumulative implant survival rate. Seventeen studies evaluating peri-implant tissue status presented following items as evaluation criteria; marginal bone level (14), plaque Index (13), probing depth (8), bleeding index (8), attachment gingiva level (8), gingival index (6), amount of keratinized gingiva (1). Eighteen studies evaluating prosthetic maintenance and complication also presented following items as evaluation criteria; loose matrix (17), female detachment (15), denture fracture (15), denture relining (14), abutment fracture (14), abutment screw loosening (11), and occlusal adjustment (9). Atypical questionnaire (9), Visual analog scales (VAS) (4), and Oral Health Impact Profile (OHIP) (1) were used as the format of criteria to evaluate patients satisfaction in 14 studies. CONCLUSION. For evaluation of implant overdenture, it is necessary to include cumulative survival rate for implant evaluation. It is suggested that peri-implant tissue evaluation criteria include marginal bone level, plaque index, bleeding index, probing depth, and attached gingiva level. It is also suggested that prosthetic evaluation criteria include loose matrix, female detachment, denture fracture, denture relining, abutment fracture, abutment screw loosening, and occlusal adjustment. Finally standardized criteria like OHIP-EDENT or VAS are required for patient satisfaction.

Outcomes and Complications of Total Elbow Arthroplasty (주관절 치환술의 임상 결과와 합병증)

  • Park, Min-Jong
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.146-152
    • /
    • 2011
  • Purpose: To describe the recent clinical results and complications of total elbow arthroplasty based on the literature review. Materials and Methods: The indications of total elbow arthroplasty include rheumatoid or inflammatory arthritis, posttraumatic arthritis, anklylosed elbow, tumor resection which cannot recover elbow function by other reconstructive procedures, and comminuted distal humerus fracture in elderly patients. Complications are aspetic loosening, infection, prosthesis fracture, periprosthetic fracture, ulnar neuropathy, ectopic ossification, triceps insufficiency, dislocation, and bushing wear. Results and Conclusion: Mean 10 year survival rate following total elbow arthroplasty has been reported 85% on the basis of revision. The prognosis in patients with an inflammatory arthritis is reported to be best, and loosening rate in patients with a posttraumatic arthritis tends to be high. Complication rate is known to be higher than that of other joint arthroplasty. In particular, deep infection occurs in 3~5% of the patients. Total elbow arthroplasty provide satisfactory results when it is performed properly in selected patients who have an elbow joint with irreversible dysfunction and low level activities.