• Title/Summary/Keyword: Prosthesis loosening

Search Result 68, Processing Time 0.029 seconds

Mechanical and biological complication rates of the modified lateral-screw-retained implant prosthesis in the posterior region: an alternative to the conventional Implant prosthetic system

  • Lee, Jae-Hong;Lee, Jong-Bin;Kim, Man-Yong;Yoon, Joon-Ho;Choi, Seong-Ho;Kim, Young-Taek
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.150-157
    • /
    • 2016
  • PURPOSE. The modified lateral-screw-retained implant prosthesis (LSP) is designed to combine the advantages of screw- and cement-retained implant prostheses. This retrospective study evaluated the mechanical and biological complication rates of implant-supported single crowns (ISSCs) inserted with the modified LSP in the posterior region, and determined how these complication rates are affected by clinical factors. MATERIALS AND METHODS. Mechanical complications (i.e., lateral screw loosening [LSL], abutment screw loosening, lateral screw fracture, and ceramic fracture) and biological complications (i.e., peri-implant mucositis [PM] and peri-implantitis) were identified from the patients' treatment records, clinical photographs, periapical radiographs, panoramic radiographs, and clinical indices. The correlations between complication rates and the following clinical factors were determined: gender, age, position in the jaw, placement location, functional duration, clinical crown-to-implant length ratio, crown height space, and the use of a submerged or nonsubmerged placement procedure. RESULTS. Mechanical and biological complications were present in 25 of 73 ISSCs with the modified LSP. LSL (n=11) and PM (n=11) were the most common complications. The incidence of mechanical complications was significantly related to gender (P=.018). The other clinical factors were not significantly associated with mechanical and biological complication rates. CONCLUSION. Within the limitations of this study, the incidence of mechanical and biological complications in the posterior region was similar for both modified LSP and conventional implant prosthetic systems. In addition, the modified LSP is amenable to maintenance care, which facilitates the prevention and treatment of mechanical and biological complications.

Reconstruction of failed fixed implant prosthesis accompanied by abutment screw loosening and fracture : A case report (나사풀림과 나사파절이 동반된 실패한 임플란트 고정성 보철물의 회복증례)

  • Bae, Eun-Bin;Shin, Young-Gun;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of the Korean dental association
    • /
    • v.55 no.7
    • /
    • pp.457-466
    • /
    • 2017
  • In the case of failed fixed implant prosthesis accompanied by abutment screw fracture, fractured screw fragment must be removed to use the existing implant fixtures. A 61-year-old male patient, who had a failed maxillary fixed implant prosthesis accompanied by three abutment screw fracture, hoped to reconstruct the maxillary implant prosthesis, while maintaining the existing implant fixtures. To use the existing implant fixtures, fractured screw fragments were removed. A maxillary implant overdenture using available existing implants was planned. Bar-attachment with Locator was used for implant splinting, denture stability, and retention. Final impression was taken after treatment of peri-implantitis. Jaw relation registration was taken to evaluate available interarch space for bar-attachment. After fabricating bar-attachment, centric relation was taken. Implant overdenture using bar-attachment with Locator was delivered after wax-denture evaluation. This case report showed that a satisfactory clinical result was achieved by implant overdenture using existing implant fixtures in a maxillary edentulous patient.

  • PDF

Implant-supported overdenture manufactured using CAD/CAM techniques to achieve horizontal path insertion between the primary and secondary structure: A clinical case report

  • Agustin-Panadero, Ruben;Penarrocha-Oltra, David;Gomar-Vercher, Sonia;Ferreiroa, Alberto;Penarrocha-Diago, Miguel
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.264-270
    • /
    • 2015
  • This report describes the case of an edentulous patient with an atrophic maxilla and severe class III malocclusion. Prosthetic rehabilitation was performed using CAD/CAM techniques for manufacturing an implant-supported overdenture with horizontal insertion. A vestibulo-lingual insertion overdenture is a precision prosthesis with a fixation system affording a good fit between the primary and secondary structure. Both structures exhibit passive horizontal adjustment. This treatment option requires the same number of implants as implant-supported fixed dentures. The horizontal assembly system prevents the prosthesis from loosening or moving in response to axial and non-axial forces. The technique was used to rehabilitate a patient presenting an atrophic upper maxilla, with the insertion of 8 implants. No complications were reported at follow-up 3, 6 and 12 months after fitting of the prosthesis. This system offers solutions to the clinical and laboratory complications associated with hybrid prostheses, concealing emergence of the chimneys and improving implant-prosthesis hygiene.

Pullout Strength after Expandable Polymethylmethacrylate Transpedicular Screw Augmentation for Pedicle Screw Loosening

  • Kang, Suk-Hyung;Cho, Yong Jun;Kim, Young-Baeg;Park, Seung Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.4
    • /
    • pp.229-234
    • /
    • 2015
  • Objective : Pedicle screw fixation for spine arthrodesis is a useful procedure for the treatment of spinal disorders. However, instrument failure often occurs, and pedicle screw loosening is the initial step of a range of complications. The authors recently used a modified transpedicular polymethylmethacrylate (PMMA) screw augmentation technique to overcome pedicle screw loosening. Here, they report on the laboratory testing of pedicle screws inserted using this modified technique. Methods : To evaluate pullout strengths three cadaveric spinal columns were used. Three pedicle screw insertion methods were utilized to compare pullout strength; the three methods used were; control (C), traditional transpedicular PMMA augmentation technique (T), and the modified transpedicular augmentation technique (M). After control screws had been pulled out, loosening with instrument was made. Screw augmentations were executed and screw pullout strength was rechecked. Results : Pedicle screws augmented using the modified technique for pedicle screw loosening had higher pullout strengths than the control ($1106.2{\pm}458.0N$ vs. $741.2{\pm}269.5N$; p=0.001). Traditional transpedicular augmentation achieved a mean pullout strength similar to that of the control group ($657.5{\pm}172.3N$ vs. $724.5{\pm}234.4N$; p=0.537). The modified technique had higher strength than the traditional PMMA augmentation technique ($1070.8{\pm}358.6N$ vs. $652.2{\pm}185.5N$; p=0.023). Conclusion : The modified PMMA transpedicular screw augmentation technique is a straightforward, effective surgical procedure for treating pedicle screw loosening, and exhibits greater pullout strength than traditional PMMA transpedicular augmentation. However, long-term clinical evaluation is required.

A VITRO STUDY OF RETAINED SCREW STABILITY BY VARIOUS CONNECTION DESIGNS BETWEEN FIXTURE AND ABUTMENT IN IMPLANT DENTISTRY (임플란트 고정체와 지대주 연결 형태의 차이에 따른 유지 나사 안정성에 대한 연구)

  • Yang Jae-Sik;Vang Mong-Sook;Jo Gyu-Jong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.83-93
    • /
    • 2004
  • Statement of problem : Since the concept of osseointegrated dental implant by $Br{\aa}nemark$ et al was first applied to mandibular full edentulous patients. Recently it is considerated the first treatment option on missing teeth. A common problem associated with dental implant restorations is loosening of screws that retain the prosthesis to the abutment and the abutment to the implant fixture. Purpose : This study is to examine the influence on screw loosening of implant-abutment designs. Material and methods : External hex, cone screw, beveled hex, cam cylinder, cylinder hex by means of evaluating the loosening torques, with respect to a range of tightening torques after repeated loading. Result : 1. Cone screw, beveled hex groups are the highest initial tightening rate and cylinder hex, external hex groups are the lowest initial tightening rate (p < 0.05). 2. Cone screw groups are the highest after repeated loading tightening rate and cylinder hex groups are lowest after repeated loading tightening rate(p < 0.05). 3. Cone screw groups have the highest initial stability and anal stability. 4. All groups are decreased tightening rate after repeated loading.

Total elbow arthroplasty for posttraumatic destroyed or unreduced elbow joint (외상 후 파괴된 주관절 또는 진구성 탈구에서의 주관절 전치환술)

  • Kim, Young-Kyu;Jung, Lee-Hyuk
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.1
    • /
    • pp.37-43
    • /
    • 2003
  • Purpose: To evaluate the results in patients who received total elbow replacement for posttraumatic destroyed or unreduced elbow joint. Materials and Methods: Six patients with posttraumatic destroyed, or unreduced elbow joint, who were nearly impossible to move actively and had pain and grossly unstable joint, were followed up average 42 months. 3 cases were soft tissue injuries and bone defects which were caused by severe comminuted fracture, 1 was a nonunion with comminuted fracture, and 2 were unreduced elbow joint. Total elbow replacement was performed average 10 months after the injury. All the cases were used by semiconstrained prosthesis, and the results were estimated by Mayo elbow perfomance score. Results: Pain was decreased in all the cases postoperatively. Average ranges of motion were improved with active extension 20° and flexion 120°. Mayo elbow performance scores were pain 42.5 points, range of motion 17.5 points, stability 8.3 points, function 19.2 points and totally 87.5 points, and final results were 3 excellent and 3 good. Loosening of prosthesis was not found in all the cases by final follow-up radiograph. Conclusicon: Semiconstrained TER can be used as a effective treatment improving pain and active ranges of motion caused by posttraumatic destroyed or unreduced elbow joint, however, long term follow-up is needed because early loosening of TER can be occurred due to severe bone defects.

Analysis of Loosening Phenomenon in Artificial Hip Joint Application Related to Design Parameters (인공고관절의 설계인자들이 해리현상에 미치는 영향에 대한 해석)

  • Kim, Young-Eun;Chung, Chung-Hwa
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.155-162
    • /
    • 1993
  • The human's biomechanical structure keeps an optimal state by adapting the original biomechanical structure according to a change in the physical environment. This phenomenon is believed to be the main cause of loosening of the total hip replacement which is used widely in these days. In this study the bone density change due to artificial hip joint, which is generally believed as bone-remodeling, was investigated by the finite element method. For this, 2-D FEM models with 4 nodal point elements were constructed for intact and implanted cases. The density was calculated by comparing the relative amounts of effective stress for these two cases. In this way, calculated new density values were used in the next step as input values and this procedure repeated until convergence was obtained. Severe density change was detected at the femoral cortex of the proximal-medial side as expected. Moreover, following surprising result was found from this analysis. Titanium alloy prosthesis showed less density change compared to stainless steel prosthesis at earlier stage, however, almost same amount of the density change was detected at final stage. It was also found that other design parameters could not significantly affect its density change.

  • PDF

Hip Arthroplasty Using the Bencox® Hip System: An Evaluation of a Consecutive Series of One Thousand Cases

  • Lee, Joong-Myung;Sim, Young-Suk;Choi, Dae-Sung
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.210-218
    • /
    • 2018
  • Purpose: This is a report on the outcomes associated with a consecutive series of 1,000 cementless hip arthroplasties utilizing the $Bencox^{(R)}$ hip stem-the first Korean-developed hip prosthesis. Materials and Methods: A consecutive series of 1,000 hip arthroplasties using the $Bencox^{(R)}$ hip stem were analyzed, starting from its initial release (September 2006) until June 2014. Patients in this consecutive series underwent surgery for fractures (n=552), arthritis (n=155), avascular necrosis (n=209), and revisions (n=84). Of these 1,000 cases, patients with a minimum follow-up of at least 1 year (n=616) were retrospectively analyzed for radiographic and clinical outcomes (i.e., Harris hip score). The stability of the prosthesis was evaluated by examining subsidence. Results: During the follow-up period (mean follow-up period of 54.8 months), there were 2 cases requiring revision of the femoral stem-both were caused by periprosthetic fractures and neither involved stem loosening. The mean Harris hip score during follow-up was 95.5. Bone ongrowth occurred in 95% of patients; no cases of subsidence or aseptic loosening of the stem were detected, and no cases of postoperative complications such as ceramic breakage were observed. Conclusion: Clinical and radiographic evaluations of hip arthroplasty using the $Bencox^{(R)}$ hip stem revealed excellent outcomes with an average of 54.8 month follow-up in a consecutive series of 1,000 cases.

In Vivo Kinematics of a Mobile-bearing Total Knee Prosthesis (이동베어링형 인공무릎전치환관절의 생체내의 운동)

  • Lee, Yeon-Soo;Park, Sang-Jin;Song, Eun-Kyoo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1473-1474
    • /
    • 2008
  • In the total knee arthroplasty (TKA), kinematic benefic of a mobile-bearing total knee prosthesis is still arguing. Main reasons for implant failure are loosening and polyethylene wear and should be solved with new designs with mob ile bearings. The kinematics of the knee prosthesis also affects the implant failure. Recently, a second generation of p rostheses with a mobile-bearing was developed. The current study aimed to assess the kinematic path of the 2nd generation mobile knee prosthesis compared to the normal knees. Using 3D/2D registration method, CT-derived 3D knee models were fitted to sequential 2D X-ray images during knee flexion. 3D kinematics of the femur and the tibia were analyzed. The 2nd generation mobile-bearing TKA prosthesis (e.motion, Aesculap, Germany) knees showed less external rotation and knee flexion range compared to the normal knee, but the trend of external rotation was similar each other.

  • PDF

Influence of the implant abutment types and the dynamic loading on initial screw loosening

  • Kim, Eun-Sook;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.1
    • /
    • pp.21-28
    • /
    • 2013
  • PURPOSE. This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS. Three groups of abutments were produced using different types of fabrication methods; stock abutment, gold cast abutment, and CAD/CAM custom abutment. A customized jig was fabricated to apply the load at $30^{\circ}$ to the long axis. The implant fixtures were fixed to the jig, and connected to the abutments with a 30 Ncm tightening torque. A sine curved dynamic load was applied for $10^5$ cycles between 25 and 250 N at 14 Hz. Removal torque before loading and after loading were evaluated. The SPSS was used for statistical analysis of the results. A Kruskal-Wallis test was performed to compare screw loosening between the abutment systems. A Wilcoxon signed-rank test was performed to compare screw loosening between before and after loading in each group (${\alpha}$=0.05). RESULTS. Removal torque value before loading and after loading was the highest in stock abutment, which was then followed by gold cast abutment and CAD/CAM custom abutment, but there were no significant differences. CONCLUSION. The abutment types did not have a significant influence on short term screw loosening. On the other hand, after $10^5$ cycles dynamic loading, CAD/CAM custom abutment affected the initial screw loosening, but stock abutment and gold cast abutment did not.