• Title/Summary/Keyword: Prosthesis failure

Search Result 162, Processing Time 0.025 seconds

Ankle Salvage Procedure without Internal Fixation for Large Bone Defect after Failed Total Ankle Arthroplasty: A Case Report (실패한 족관절 인공관절 치환술 후 큰 골결손에서 내고정 없이 시행한 족관절 구제술: 증례 보고)

  • Park, Man-Jun;Eun, Il-Soo;Jung, Chul-Young;Ko, Young-Chul;Yoo, Chong-Il;Kim, Min-Woo;Hwang, Keum-Min
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.2
    • /
    • pp.76-79
    • /
    • 2014
  • In treatment of failure in ankle joint replacement therapy, talar avascular necrosis with massive bone defect, talus fracture with severe comminution and bone defect and ankle dislocation, treatment of large bone defects is considerably important for ankle joint stability and union, therefore, the choice of treatment for large bone defects is use of femoral head or iliac crest bone graft and rigid internal fixation. Because first generation total ankle arthroplasty performed for the first time using a cemented fixation technique requires a large amount of bone resection during re-surgery and there is some possibility of a larger bone defect after removal of implants, in cases where prosthesis for the defect is needed, performance of palliative femoral head or iliac crest bone graft and rigid internal fixation can be difficult. We report on a case of a 48-year-old woman who had experienced ankle pain for 25 years since undergoing total ankle arthroplasty. Because the patient had little ankle motion and rigid soft tissue despite a large bone defect caused by aseptic loosening, a good outcome was obtained only for the femoral cancellous bone graft using allo femoral head without internal fixation.

Mechanical Response of Changes in Design of Compression Hip Screws with Biomechanical Analysis (생체 역학적 분석에 의한 Compression Hip Screw의 디자인 요소에 대한 평가)

  • 문수정;이희성;권순영;이성재;안세영;이훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1172-1175
    • /
    • 2004
  • At present, CHS(Compression Hip Screw) is one of the best prosthesis for the intertrochanteric fracture. There is nothing to evaluate the CHS itself with the finite element analysis and mechanical tests. They have same ways of the experimental test of the ASTM standards. The purpose of this study is to evaluate the existing CHS and the new CHS which have transformational design factors with finite element analysis and mechanical tests. The mechanical tests are divided into compression tests and fatigue test for evaluating the failure load, strength and fatigue life. This finite element method is same as the experimental test of the ASTM standards. Under 300N of compression load at the lag screw head. There are less differences between Group (5H, basic type) and Group which has 8 screw holes. However, there are lots of big differences between Group and Group which is reinforced about thickness of the neck range. Moreover, the comparison of Group and Group shows similar tendency of the comparison of Group and Group . The Group is reinforced the neck range from Group. After the experimental tests and the finite element analysis, the most effective design factor of the compression hip screws is the reinforcement of the thickness, even though, there are lots of design factors. Moreover, to unite the lag screw with the plate and to analyze by static analysis, the result of this method can be used with experimental test or instead of it.

  • PDF

Tricuspid Valve Endocarditis (삼첨판막 심내막염)

  • 문광덕;김대영
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.440-443
    • /
    • 1996
  • Some tricuspid valve endocarditis can be controlled effectively with specific antibiotic treatment. However, surgical intervention Is necessary when there are continuing sepsis, moderate or severe heart failure, multiple pulmonary emboli, and echocardiographycally demonstrated vegitations. We are repoting a 19 year-old male patient who was admitted for the treatment of infective endocarditis. He previously had an operation for ventriculer septal defect (perimembranous type) about 9 years ago . An echocardiogram showed a large vegetation on the anterior cusp area and a left to right shunt through VSD, which was previously closed with dacron patch. A valve replacement in addition to antibiotic therapy was recommended for the patient. The patient underwent on operation : tricuspid valve replacement was done with 51. Jude medical valve prosthesis (33 mm), and in addition to above procedure, removal of vegetation and direct closure of VSD were done Postoperative echocardiogram showed that replaced tricuspid valve functioned well and vegeta ion and shunt flow were not observed. The patient recovered without complication and discharged at Postoperative day 25. Early aggressive surgical intervention is indicated to optimize surgical results, and this case seems to be a typical right sided bacterial endocarditis, which is caused by residual VSD. We are reporting a case of tricuspid valve endocarditis with a review of the literature. (Korean J Thorax Cardiovasc Surg 1996 ; 29: 440-3)

  • PDF

Surgical Treatment of Prosthetic Valve Endocarditis after Reconstruction of the Intervalvular Fibrous Trigon -A case report- (판막간 섬유체 재건을 시행한 후 발생한 인공판막 심내막염의 수술적 치유 -1예 보고-)

  • Choi, Seon-Uoo;Kim, Wook-Sung;Min, Ho-Ki;Kang, Min-Woong;Lee, Young-Tak;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.755-758
    • /
    • 2008
  • We report here on a case of performing a redo-operation for a 65-years-old male patient who had prosthetic endocarditis after reconstruction of the fibrous skeleton due to infective endocarditis 8 years earlier. An aortic annular abscess with a 1cm sized subvalvular abscess and mobile mitral valve vegetation with destruction of the fibrous skeleton was shown on the preoperative echocardiography. An emergency operation was performed due to heart failure. Reconstruction of both the aortic and mitral annuli and the fibrous skeleton was done by using two separate bovine pericardial patches and then mechanical valves were implanted. The postoperative echocardiography shows no paravalvular leakage. The patient has been followed up with no symptoms.

Mandibular Implant-Supported Telescopic Overdenture using Gold Electroforming System : A Case Report (Gold Electroforming System을 이용한 하악 임플란트 지지 텔레스코프 피개의치)

  • Choi, Jee-Ha;Kim, Seung-Kyun;Yu, Byoung-Il;Ahn, Seung-Geun;Park, Ju-Mi;Song, Kwang-Yeob;Park, Charn-Woon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.193-201
    • /
    • 2008
  • In edentulous mandible, implant supported overdenture was considered as a first treatment option. In case of a implant supported telescopic overdenture, sufficient inter-arch space needs for arrangement of artificial teeth and attachment. Passive fit of the implant prosthesis is important factor for preventing mechanical failure. Gold Electroforming System is particularly useful to achieve a passive fit of telescopic attachment and results in precision marginal fit and the small thickness of the coping provides optimal space for narrow inter-arch space. This article presents that application of Gold Electroforming System can provide excellent esthetics and function on four-implant supported telescopic overdenture.

Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review

  • Kim, Ha-Young;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.325-332
    • /
    • 2014
  • PURPOSE. The aim of this review was to analyze the evaluation criteria on mandibular implant overdentures through a systematic review and suggest standardized evaluation criteria. MATERIALS AND METHODS. A systematic literature search was conducted by PubMed search strategy and hand-searching of relevant journals from included studies considering inclusion and exclusion criteria. Randomized clinical trials (RCT) and clinical trial studies comparing attachment systems on mandibular implant overdentures until December, 2011 were selected. Twenty nine studies were finally selected and the data about evaluation methods were collected. RESULTS. Evaluation criteria could be classified into 4 groups (implant survival, peri-implant tissue evaluation, prosthetic evaluation, and patient satisfaction). Among 29 studies, 21 studies presented implant survival rate, while any studies reporting implant failure did not present cumulative implant survival rate. Seventeen studies evaluating peri-implant tissue status presented following items as evaluation criteria; marginal bone level (14), plaque Index (13), probing depth (8), bleeding index (8), attachment gingiva level (8), gingival index (6), amount of keratinized gingiva (1). Eighteen studies evaluating prosthetic maintenance and complication also presented following items as evaluation criteria; loose matrix (17), female detachment (15), denture fracture (15), denture relining (14), abutment fracture (14), abutment screw loosening (11), and occlusal adjustment (9). Atypical questionnaire (9), Visual analog scales (VAS) (4), and Oral Health Impact Profile (OHIP) (1) were used as the format of criteria to evaluate patients satisfaction in 14 studies. CONCLUSION. For evaluation of implant overdenture, it is necessary to include cumulative survival rate for implant evaluation. It is suggested that peri-implant tissue evaluation criteria include marginal bone level, plaque index, bleeding index, probing depth, and attached gingiva level. It is also suggested that prosthetic evaluation criteria include loose matrix, female detachment, denture fracture, denture relining, abutment fracture, abutment screw loosening, and occlusal adjustment. Finally standardized criteria like OHIP-EDENT or VAS are required for patient satisfaction.

Surface Tribology of Total Ankle Joint Replacement (인공발목관절의 표면 마모 특성)

  • Jeong, Yong-Hoon;Jung, Tae-Gon;Yang, Jae-Woong;Park, Kwang-Min;Lee, Su-Won
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.117-117
    • /
    • 2016
  • Total ankle replacement (TAR) is a visible option in the surgical treatment of degenerative or inflammatory diseases of ankle joint. it is attributed to the current TAR which has improvements in surgical technique, uncemented implant fixation and minimally constrained articulation. In the clinical result, they can show promised surgical result when compared to earlier attempts in TAR. However, TAR is still not as successful as total knee replacement (TKR) or total hip replacement (THR), it needs to be note that there are limitations in concerning of long term performance of TAR, the high failure rate still associated with wear of the PE (polyethylene) component that has related with their material property and surface roughness. The aim of this study was to introduce the tribology characteristics of total ankle joint prosthesis with one of TDR model which was fabricated to try multi-axis wear test as a region of motion in ankle joint. The wear specimen of TDR was prepared with Ti-6Al-4V alloy and UHMWPE (ultra-high molecular weight polyethylene) for tibia-talus and bearing component, respectively. A wear test was carried out using a Force 5 (AMTI, Massachusetts, US) wear simulator which can be allowed to move in three axis to flexion-extension ($+3^{\circ}{\sim}-6^{\circ}$), internal-external axial rotation (${\pm}5^{\circ}$), as well as sinusoidal compressive load (1.6 kN, R=10). All tests were performed following standard ISO 14243, wear rate was calculated with weight loss of UHMWPE bearing while the specimen has tested at certain cycles. As based on the preliminary results, wear rate of UHMWPE bearing was $7.9{\times}10^{-6}mg/cycles$ ($R^2=0.86$), calculated loss weight until $10^7cycles$ was 79 mg, respectively.

  • PDF

Influence of the implant abutment types and the dynamic loading on initial screw loosening

  • Kim, Eun-Sook;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.1
    • /
    • pp.21-28
    • /
    • 2013
  • PURPOSE. This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS. Three groups of abutments were produced using different types of fabrication methods; stock abutment, gold cast abutment, and CAD/CAM custom abutment. A customized jig was fabricated to apply the load at $30^{\circ}$ to the long axis. The implant fixtures were fixed to the jig, and connected to the abutments with a 30 Ncm tightening torque. A sine curved dynamic load was applied for $10^5$ cycles between 25 and 250 N at 14 Hz. Removal torque before loading and after loading were evaluated. The SPSS was used for statistical analysis of the results. A Kruskal-Wallis test was performed to compare screw loosening between the abutment systems. A Wilcoxon signed-rank test was performed to compare screw loosening between before and after loading in each group (${\alpha}$=0.05). RESULTS. Removal torque value before loading and after loading was the highest in stock abutment, which was then followed by gold cast abutment and CAD/CAM custom abutment, but there were no significant differences. CONCLUSION. The abutment types did not have a significant influence on short term screw loosening. On the other hand, after $10^5$ cycles dynamic loading, CAD/CAM custom abutment affected the initial screw loosening, but stock abutment and gold cast abutment did not.

The Effect of Uncinate Process Resection on Subsidence Following Anterior Cervical Discectomy and Fusion

  • Lee, Su Hun;Lee, Jun Seok;Sung, Soon Ki;Son, Dong Wuk;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.550-559
    • /
    • 2017
  • Objective : Subsidence is a frequent complication of anterior cervical discectomy and fusion. Postoperative segmental micromotion, thought to be a causative factor of subsidence, has been speculated to increase with uncinate process resection area (UPR). To evaluate the effect of UPR on micro-motion, we designed a method to measure UPR area based on pre- and postoperative computed tomography images and analyzed the relationship between UPR and subsidence as a proxy of micro-motion. Methods : We retrospectively collected clinical and radiological data from January 2011 to June 2016. A total of 38 patients (53 segments) were included. All procedures included bilateral UPR and anterior plate fixation. UPR area was evaluated with reformatted coronal computer tomography images. To reduce level-related bias, we converted UPR area to the proportion of UPR to the pre-operative UP area (pUPR). Results : Subsidence occurred in 18 segments (34%) and positively correlated with right-side pUPR, left-side pUPR, and the sum of bilateral pUPR (sum pUPR) (R=0.310, 301, 364; p=0.024, 0.029, 0.007, respectively). Multiple linear regression analysis revealed that subsidence could be estimated with the following formula : $subsidence=1.522+2.7{\times}sum\;pUPR$($R^2=0.133$, p=0.007). Receiver-operating characteristic analysis determined that sum $pUPR{\geq}0.38$ could serve as a threshold for significantly increased risk of subsidence (p=0.005, area under curve=0.737, sensitivity=94%, specificity=51%). This threshold was confirmed by logistic regression analysis for subsidence (p=0.009, odds ratio=8.471). Conclusion : The UPR measurement method confirmed that UPR was correlated with subsidence. Particularly when the sum of pUPR is ${\geq}38%$, the possibility of subsidence increased.

A Lower T1 Slope as a Predictor of Subsidence in Anterior Cervical Discectomy and Fusion with Stand-Alone Cages

  • Lee, Su Hun;Lee, Jun Seok;Sung, Soon Ki;Son, Dong Wuk;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.567-576
    • /
    • 2017
  • Objective : Preoperative parameters including the T1 slope (T1S) and C2-C7 sagittal vertical axis (SVA) have been recognized as predictors of kyphosis after laminoplasty, which is accompanied by posterior neck muscle damage. The importance of preoperative parameters has been under-estimated in anterior cervical discectomy and fusion (ACDF) because there is no posterior neck muscle damage. We aimed to determine whether postoperative subsidence and pseudarthrosis could be predicted according to specific parameters on preoperative plain radiographs. Methods : We retrospectively analyzed 41 consecutive patients (male : female, 22 : 19; mean age, $51.15{\pm}9.25years$) who underwent ACDF with a stand-alone polyether-ether-ketone (PEEK) cage (>1 year follow-up). Parameters including SVA, T1S, segmental angle and range of motion (ROM), C2-C7 cervical angle and ROM, and segmental inter-spinous distance were measured on preoperative plain radiographs. Risk factors of subsidence and pseudarthrosis were determined using multivariate logistic regression. Results : Fifty-five segments (27 single-segment and 14 two-segment fusions) were included. The subsidence and pseudarthrosis rates based on the number of segments were 36.4% and 29.1%, respectively. Demographic data and fusion level were unrelated to subsidence. A greater T1S was associated with a lower risk of subsidence (p=0.017, odds ratio=0.206). A cutoff value of T1S<$28^{\circ}$ significantly predicted subsidence (sensitivity : 70%, specificity : 68.6%). There were no preoperative predictors of pseudarthrosis except old age. Conclusion : A lower T1S (T1S<$28^{\circ}$) could be a risk factor of subsidence following ACDF. Surgeons need to be aware of this risk factor and should consider various supportive procedures to reduce the subsidence rates for such cases.