• Title/Summary/Keyword: Prosthesis, failure

Search Result 162, Processing Time 0.025 seconds

A method of contouring occlusal surface for reduction of implant overload (Implant overload 감소를 위한 교합면 형성 방법)

  • Lee, Byung-Woo;Park, Chan-Jin;Cho, Lee-Ra;Yi, Yang-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.105-108
    • /
    • 2003
  • After stage-two surgery, the highest incidence of failure has been attributed to implant overload. However, the biomechanical factors cited inthe literature that contribute to implant overload, such as bone type, cuspal inclination, horizontal offset, maxillary compared to mandibular arch, the inclusion of natural teeth within the prosthesis, and occlusal harmony are superimposed on physiologic variations. Following two cases, including reduction of cuspal inclination and usage of modified incisal pin, showed a method of contouring occlusal surface for reduction of unpreditable implant overload.

Speech treatment of velopharyngeal insufficiency using biofeedback technique with NM II; A case report (Nasometer 활용 바이오피드백 기법을 이용한 비인강폐쇄전환자의 치험 사례)

  • Yang Ji-Hyung;Choi Jin-Young
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.8 no.1
    • /
    • pp.45-52
    • /
    • 2005
  • Velopharyngeal Insufficiency(VPI); the failure of velum, the lateral wall and the posterior pharyngeal wall to separate the nasal cavity from pharyngeal cavity during speech, can be caused by congenital conditions include cleft palate, submucous cleft palate and congenital palatal insufficiency. Speech problems of VPI are characterized by hypernasality, nasal air emission, increased nasal air flow and decreased intelligibility. These speech problems of VPI can be treated with the surgical procedure, the application of temporary prosthesis and speech therapy. Biofeedback technique with Nasometer is a speech treatment method of VPI that commonly used as one component of a comprehensive procedure for improvement of speech in patients with VPI. In this article describes a case of VPI treated by biofeedback technique with Nasometer; which showed satisfactory result in nasalance and formant analysis after the speech therapy during 9 months.

  • PDF

Left Ventricular Rupture Related to MVR - 2 Case Report - (승모판 치환술에 관련된 좌심실 파열[2례])

  • 최순호
    • Journal of Chest Surgery
    • /
    • v.25 no.6
    • /
    • pp.605-610
    • /
    • 1992
  • Improving intraoperative and postoperative myocardial protection and better construction and design of valvular prosthesis has reduced the mortality of MVR. But, ventricular rupture after MVR occurred occasionally and represented a potentially lethal complication. Transverse midventricular disruption presented as refractory myocardial failure immediately on termination of bypass or later often on initial period of good hemadynamics. From Jan., 1985 through Dec., 1991 131 MVRs were performed as isolated or combined procedures. Rupture of the posterior wall of left ventricle was observed in 2 patients. There were 2 type III ruptures Prevention is of utmost importance, and by taking certain precautions, the chance of ventricular rupture can be reduced. Repair should always be done by patch technique in the aid of the use of cardiopulmonary bypass with cardioplegic arrest. When the laceration is in the middle of the posterior left ventricle, external repair with the pericardial patch can be attempted first.

  • PDF

The effect of Radiation Therapy on the Use of Proven Prosthesis in Laryngectomees (방사선 치료 환자에서의 Provox 사용)

  • 김광현;성명훈;이창호;전상준;고태용
    • Korean Journal of Bronchoesophagology
    • /
    • v.4 no.2
    • /
    • pp.177-181
    • /
    • 1998
  • Provox is now widely used for voice rehabilitation for total laryngectomized patient because of its low airway resistance and easiness for phonation. This study was designed to reveal the influence of radiation therapy on Proven complications. Forty-four patients who underwent total laryngectomy were grouped into group A (no radiation), group B(radiation and then Provox insertion), group C(Proven insertion and then radiation). Provox complications were leakage, granulation tissue formation, malfunction and infection. The average survival time of Provox was longer in group C (9.2 me) than group A(8.6 m) or group B (7.3 me), but no statistical significance was found. The first time of Provox change was 10.2, 8.6 and 9.7 months respectively. The incidence of complication was not significantly different among groups. The cases of Provox remeval due to shunt failure were 5, 4 and 2 respectively. Even though a significant statistically difference was not found partialy due to the small numbers of patients, a special caution should be exercised in inserting Provox to prevent a serious complication for the patients who had a history of previous radiation.

  • PDF

Retrospective study on survival, success rate and complication of implant-supported fixed prosthesis according to the materials in the posterior area (구치부 임플란트 지지 고정성 보철물의 재료에 따른 생존율, 성공률 및 합병증에 대한 후향적 연구)

  • Chae, Hyun-Seok;Wang, Yuan-Kun;Lee, Jung-Jin;Song, Kwang-Yeob;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.342-349
    • /
    • 2019
  • Purpose: The purpose of this study was to retrospectively investigate the survival and success rate of implant-supported fixed prosthesis according to the materials in the posterior area. Other purposes were to observe the complications and evaluate the factors affecting failure. Materials and methods: Patients who had been restored implant prosthesis in the posterior area by the same prosthodontist in the department of prosthodontics, dental hospital, Chonbuk National University, in the period from January 2011 to June 2018 were selected for the study. The patient's sex, age, material, location, type of prosthesis and complications were examined using medical records. The KaplanMeier method was used to analyze the survival and success rate. The Log-rank test was conducted to compare the differences between the groups. Cox proportional hazards model was used to assess the association between potential risk factors and success rate. Results: A total of 364 implants were observed in 245 patients, with an average follow-up of 17.1 months. A total of 5 implant prostheses failed and were removed, and the 3 and 5 year cumulative survival rate of all implant prostheses were 97.5 and 91.0, respectively. The 3 and 5 year cumulative success rate of all implant prostheses were 61.1% and 32.9%, respectively. Material, sex, age, location and type of prosthesis did not affect success rate (P>.05). Complications occurred in the order of proximal contact loss (53 cases), retention loss (17 cases), peri-implant mucositis (12 cases), infraocclusion (4 cases) and so on. Conclusion: Considering a high cumulative survival rate of implant-supported fixed prostheses, regardless of the materials, implant restored in posterior area can be considered as a reliable treatment to tooth replacement. However, regular inspections and, if necessary, repairs and adjustments are very important because of the frequent occurrence of complications.

Considerations for patient selection: Prepectoral versus subpectoral implant-based breast reconstruction

  • Yang, Jun Young;Kim, Chan Woo;Lee, Jang Won;Kim, Seung Ki;Lee, Seung Ah;Hwang, Euna
    • Archives of Plastic Surgery
    • /
    • v.46 no.6
    • /
    • pp.550-557
    • /
    • 2019
  • Background In recent years, breast implants have been frequently placed in the subcutaneous pocket, in the so-called prepectoral approach. We report our technique of prepectoral implant-based breast reconstruction (IBR), as well as its surgical and aesthetic outcomes, in comparison with subpectoral IBR. We also discuss relevant considerations and pitfalls in prepectoral IBR and suggest an algorithm for the selection of patients for IBR based on our experiences. Methods We performed 79 immediate breast reconstructions with a breast implant and an acellular dermal matrix (ADM) sling, of which 47 were subpectoral IBRs and 32 were prepectoral IBRs. Two-stage IBR was performed in 36 cases (20 subpectoral, 16 prepectoral), and direct-to-implant IBR in 43 cases (27 prepectoral, 16 subpectoral). The ADM sling supplemented the inferolateral side of the breast prosthesis in the subpectoral group and covered the entire anterior surface of the breast prosthesis in the prepectoral group. Results The postoperative pain score was much lower in the prepectoral group than in the subpectoral group (1.78 vs. 7.17). The incidence of seroma was higher in the prepectoral group (31.3% vs. 6.4%). Other postoperative complications, such as surgical site infection, flap necrosis, implant failure, and wound dehiscence, occurred at similar rates in both groups. Animation deformities developed in 8.5% of patients in the subpectoral group and rippling deformities were more common in the prepectoral group (21.9% vs. 12.8%). Conclusions The indications for prepectoral IBR include moderately-sized breasts with a thick well-vascularized mastectomy flap and concomitant bilateral breast reconstruction with prophylactic mastectomy.

A cumulative survival rate of implants installed on posterior maxilla augmented using MBCP after 2 years of loading: A retrospective clinical study (MBCP를 이용하여 거상된 상악 구치부에 식립한 임플란트의 기능 후 2년 누적 생존율 - 후향적 임상 연구)

  • Kim, Min-Soo;Lee, Ji-Hyun;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.4
    • /
    • pp.669-678
    • /
    • 2008
  • Purpose: The purpose of this study was to evaluate 2 years cumulative survival rate of implants on augmented sinus area using MBCP, mixture of MBCP and ICB, and mixture of MBCP and autogenous bone by means of clinical and radiologic methods. Materials and Methods: In a total of 37 patients, 41 maxillary sinuses were augmented and 89 implant fixtures were installed simultaneously or after a regular healing period. The patients were divided in 3 groups: MBCP only, MBCP combined with ICB, MBCP combined with autogenous bone. After delivery of prosthesis, along 2 years of observation period, all implants were evaluated clinically and radiologically. And the results were as follows. Results: The results of this study were as follows. 1. A 2 year cumulative survival rate of implants placed with sinus augmentation procedure using MBCP was 97.75%. 2. Survival rate of implants using MBCP only was 97.62%, MBCP and ICB was 100%, MBCP and autogenous bone was 95%. There was no statistically significant difference between 3 groups. 3. Only 2 of 89 implants were lost before delivery of prosthesis, so it can be regarded as an early failure. And both were successfully restored by wider implants. Conclusion: It can be suggested that MBCP may have predictable result when used as a grafting material of sinus floor augmentation whether combined with other graft(ICB, autogenous bone) or not. And the diameter, length, location of implants did not have a significant effect on 2 year cumulative survival rate.

Clinical Experience of Abdominal Aortic Aneurysm (복부 대동맥류의 임상적 경험)

  • Gu, Bon-Il;O, Sang-Jun
    • Journal of Chest Surgery
    • /
    • v.28 no.3
    • /
    • pp.263-267
    • /
    • 1995
  • A total and consecutive 87 patients underwent aortic valve replacement[AVR with the St. Jude Medical prosthesis between 1984 and 1993. Age ranged from 14 to 66 years[mean:38.6$\pm$ 14.0 years .Twenty-one patients [24.1% had undergone previous valve replacement. There were 8 early deaths with an operative mortality rate of 9.2% [7.6% for primary AVR and 14.3 % for re-replacement AVR . Seventy-nine early survivors were,followed for a total of 309.1 patient-years[mean:3.9$\pm$ 2.5 years . A late mortality rate was 5.1% [4 patients or a linearized incidence of 1.294 %/patient-year. All were anticoagulated with coumadin to maintain the international normal ized ratio[INR between 1.5 and 2.5. One patient experienced thromboembolism[0.324%/patient-year , and none did bleeding. Endocarditis occurred in one[0.324%/patient-year . Paravalvular leak was the most frequent complication and was experienced by 8 patients[2.588%/patient-year , and 5 of them required re-replacement AVR[1.618 %/patient year of reoperation rate . There was no structural failure of the prosthesis. Actuarial survival including operative death was 83.9%$\pm$ 4.6% at 10 years.The actuarial estimates of freedom from thromboembolism and of freedom from late death and all complications were 95.1% $\pm$ 4.8 % and 81.4% $\pm$ 6.1%, respectively, at 10 years. These clinical results suggest that less intensive anticoagulation may be allowed for patients of AVR with the St. Jude Medical valve with low incidences of both thromboembolic and bleeding complications.

  • PDF

A study on the difference of movement between Semi adjustable articulator and Oral in vivo (반조절성교합기와 구강에서의 운동 오차에 대한 비교 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.53-59
    • /
    • 2006
  • The movement range on the semi adjustable articulator and the movement range in an oral were measured. And then I studied to analyze the gap. I got wax records by the movement on the semi adjustable articulator, the movement in an oral. I measured the distance of the cusp tips that are close to the mesial direction and the distal direction, the buccal direction and the lingual direction then I compared gaps. As I saw results on data, I knew that the semi adjustable articulator represented the range of mandibular movement restrictively. I could find the decisive contradiction that the sliding movement finished on the semi adjustable articulator although it did not finish in an oral. When the sliding movement does not reappear exactly, it brings a fatal failure to the dental prosthesis. In addition it is impossible that the semi adjustable articulator restores the movement in an oral because the lateral condyle inclination and the horizontal condyle inclination are appeared to be straight. Therefore dental prosthesisses were made by the semi adjustable articulator, they will interfere with a mastication. I have obtained the following results; 1. The distance of sliding movement on the semi adjustable articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclination of the dental prosthesis that was made on the semi adjustable articulator. Therefore, when the lateral movement occurs in oral, there is a possibility to become the premature as the increase of cusp inclination. 2. The difference in the range of movement is considered as the gap that is made because the movement only can be occurred as straight in the semi adjustable articulator. 3. When the dental technician understand mandibular movement and articulator deficiencies, they can attain proficiency in use of the articulator and reduce the gap.

  • PDF

An Experimental study on the gap of movement by the hinge articulator (단순교합기에 의한 하악운동의 오차에 대한 실험적 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.111-118
    • /
    • 2003
  • I measured the movement range on the hinge articulator and the movement range in an oral. And then I studied to analyze the gap. I got wax records by the movement on the hinge articulator, the movement in an oral and the movement on the hand articulating. I measured the distance of the cusp tips that are close to the mesial direction and the distal direction, the buccal direction and the lingual direction then I compared gaps. As I saw results on data, I knew that the hinge articulator represented the range of mandibular movement restrictively. I could find the decisive contradiction that the sliding movement finished on the hinge articulator although it did not finish in an oral. If the sliding movement does not reappear exactly, it brings a fatal failure to the dental prosthesis. In addition it is impossible that the hinge articulator restores the movement in an oral because the lateral condyle inclination and the horizontal condyle inclination are fixed previously. Therefore dental prosthesisses were made by the hinge articulator, they will interfere with a mastication. I have obtained the following results; 1. The distance of sliding movement on the hinge articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclination of the dental prosthesis that was made on the hinge articulator. Therefore, when the lateral movement occurs in oral, there is a possibility to become the premature as the increase of cusp inclination. 2. The results that were impressed records in oral and impressed records on the hand articulating have many congruities. I think that the simple crown etc. that were made by the hand articulating method except the long span bridge and the free end case that can not measure the vertical dimension exactly can represent similarly the mandibular movement. 3. If we want to represent the mandibular movement similarly, we have to use the articulator that can adjust the horizontal condyle inclination and the lateral condyle inclination at least.

  • PDF