• 제목/요약/키워드: Prostheses

검색결과 703건 처리시간 0.02초

Prediction of lifespan and assessing risk factors of large-sample implant prostheses: a multicenter study

  • Jeong Hoon Kim;Joon-Ho Yoon;Hae-In Jeon;Dong-Wook Kim;Young-Bum Park;Namsik Oh
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권3호
    • /
    • pp.151-162
    • /
    • 2024
  • PURPOSE. This study aimed to analyze factors influencing the success and failure of implant prostheses and to estimate the lifespan of prostheses using standardized evaluation criteria. An online survey platform was utilized to efficiently gather large samples from multiple institutions. MATERIALS AND METHODS. During the one-year period, patients visiting 16 institutions were assessed using standardized evaluation criteria (KAP criteria). Data from these institutions were collected through an online platform, and various statistical analyses were conducted. Risk factors were assessed using both the Cox proportional hazard model and Cox regression analysis. Survival analysis was conducted using Kaplan-Meier analysis and nomogram, and lifespan prediction was performed using principal component analysis. RESULTS. The number of patients involved in this study was 485, with a total of 841 prostheses evaluated. The median survival was estimated to be 16 years with a 95% confidence interval. Factors found to be significantly associated with implant prosthesis failure, characterized by higher hazard ratios, included the 'type of clinic', 'type of antagonist', and 'plaque index'. The lifespan of implant prostheses that did not fail was estimated to exceed the projected lifespan by approximately 1.34 years. CONCLUSION. To ensure the success of implant prostheses, maintaining good oral hygiene is crucial. The estimated lifespan of implant prostheses is often underestimated by approximately 1.34 years. Furthermore, standardized form, online platform, and visualization tool, such as nomogram, can be effectively utilized in future follow-up studies.

고정성 보철물의 임상적 상태에 대한 평가 (Evaluation of clinical status of fixed prosthesis)

  • 윤미정;전영찬;정창모
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.99-107
    • /
    • 2009
  • 연구목적: 악구강계의 건강을 심미적, 기능적으로 유지 및 증진시키는 것을 목적으로 치아의 형태 이상이나 결손 등을 갖고 있는 환자들에게 고정성 보철 술식이 보편적으로 시술되어 오고 있다. 환자 스스로의 관리 부족과 더불어 부적절한 기공 과정으로 인해 보철물과 연관된 합병증이 발생할 수 있다. 이를 해결하고자 고정성 보철물의 장기간의 임상 상태 조사에 많은 노력을 기울여 왔으나 자료 수집에 어려움이 많았다. 이에 본 연구에서는 고정성 보철물의 임상적 상태를 조사하여 보철물의 치료 계획과 생존율을 높이는 guideline에 기여하고자 하였다. 연구 재료 및 방법: 2007년 4월에서 9월까지 6개월간 부산대학교병원 치과 보철과에 내원한 초진 환자 중 고정성 보철물을 장착하여 사용 중인 환자를 대상으로 보철물과 관련한 종합적인 상태를 조사하였다. 결과 및 결론: 1. 전체 고정성 보철물의 추정 수명은 10.0년이었고, 평균 장착 기간은 $8.6{\pm}0.6$년이었다. 2. 부위별 추정 수명은 차이가 없었으나(P>.05), 성공률은 하악과 구치부 보철물에서 높았고(P<.05), 전치-구치 혼합형 보철물에서는 실패율이 높았다(P<.05). 3. 재료별 추정 수명은 금속관이 14.0년으로 가장 길었고, 금합금관(10.0년), 귀금속 도재관(10.0년), 비귀금속 도재관(8.0년) 순이었다(P<.05). 그러나 금속관은 실패율이 높았고, 성공률은 금합금관과 귀금속 도재관에서 높았다. 4. 크기별 추정 수명은 차이를 보이지 않았으나(P>.05), 성공률은 단일관에서 높았고(P<.05), 실패율은 3-유닛 이상에서 높았다(P<.05). 5. 대합치 조건별 추정 수명은 차이가 없었으나(P>.05), 고정성 및 가철성 국소 의치가 대합치인 경우 실패율이 높았고, 자연치일 경우 성공률이 높았다(P<.05). 6. 고정성 보철물의 합병증은 치아 우식증(23.0%), 치주 질환(19.3%), 치수 질환(16.9%) 순이었고, 기계적 문제점은 변연 결함(28.2%), 보철물 파절(6.7%), 유지력 상실(4.8%) 순이었다. 보철물을 제거한 후 잔존 치질은 고정성 보철물의 합병증으로 인하여 30.1%가 수복 불가능한 상태였다.

포스트로 수복한 근관 치료된 치아의 임상적 상태에 대한 평가 (Complication and Failure Analysis of Endodontically Treated Teeth Restored with Post and Cores)

  • 윤미정;김무현;정창모;허중보;전영찬
    • 구강회복응용과학지
    • /
    • 제28권4호
    • /
    • pp.359-370
    • /
    • 2012
  • 근관 치료가 시행된 치아의 상당수는 많은 치질의 상실로 인하여 통상적으로 치수관 내에 포스트를 세워 유지를 얻고 코어를 제작하여 최종 보철물을 제작하는 방법으로 치료되고 있다. 포스트와 코어를 이용한 고정성 보철물의 장기적 예후를 보장하고자 하는 많은 노력에도 불구하고, 임상에서는 다양한 합병증이 관찰되고 있다. 이에 본 연구에서는 근관 치료를 받고 포스트와 코어를 시행한 치아에 제작된 고정성 보철물의 임상적 상태를 조사하여 보철 진료의 임상적 참고 자료와 연구의 기초 자료로 도움이 되고자 하였다. 1990년에서 2005년까지 부산대학교병원 치과 보철과에 내원한 환자 중 근관 치료 후 포스트와 코어를 시행하고 고정성 보철물을 치료 받은 환자를 대상으로 고정성 보철물에 연관된 임상적 상태를 조사 평가하여 다음과 같은 결과를 얻었다. 1. 전체 고정성 보철물의 추정 수명은 11.1년이었고, 평균 장착 기간은 $9.7{\pm}3.4$년이었다. 2. 나이와 성별에 따른 수명의 차이는 나타나지 않았다 (P>.05). 3. 악골에 따른 수명의 차이는 나타나지 않았으나 (P>.05), 전후방 위치에서는 전치부에서 수명이 가장 길었고 구치부, 견치를 포함하는 보철물 순으로 수명이 짧았다 (P<.05). 4. 포스트의 재료 및 방법과 고정성 보철물의 종류는 보철물의 수명에 영향을 미치지 않았으나 (P>.05), 보철물의 재료는 수명에 영향을 미쳤다(P<.05). 5. 고정성 보철물의 크기는 보철물의 수명에 영향을 미치지 않았다 (P>.05). 6. 대합치 조건별 고정성 보철물의 수명은 차이가 없었다 (P>.05). 7. 고정성 보철물의 합병증은 치아 우식증 (34.5%), 치주 질환 (25.9%), 치아 파절 (15.5%), 치수 질환 (12.1%) 순이었다. 보철물을 제거한 후 잔존 치질은 51.9%가 수복 불가능한 상태였다.

서로 다른 두 가지 스캔법을 이용하여 제작된 지르코니아 보철물의 적합도에 대한 비교 (Assessment of the fit of zirconia-based prostheses fabricated with two different scan methods)

  • 최현석;조진현
    • 대한치과보철학회지
    • /
    • 제55권2호
    • /
    • pp.135-143
    • /
    • 2017
  • 목적: 연구의 목적은 동일한 지대치에서 각각 모델스캔 방법과 구강 내 스캔 방법으로 제작된 지르코니아 보철물의 변연 및 내면적합도를 비교하는 것이다. 재료 및 방법: 발거된 사람의 하악 제1대구치 20개에 대해 지르코니아 보철물을 위한 지대치 형성이 이루어졌다. 첫 번째 그룹에서는 모델 스캔법으로 10개의 지대치를 스캔하였고, 두 번째 그룹에서는 나머지 10개에 대해 구강 내 스캔법을 사용하였다. 각각의 데이터들은 소프트웨어 시스템으로 전송되었고 Ceramill CAD/CAM system을 이용하여 20개의 지르코니아 보철물을 제작하였다. 먼저 weight technique을 사용하여 내면 적합도를 평가하였다. 다음으로 replica technique에서는 광학현미경을 통해 변연 적합도를 평가하였다. 통계처리는 일원배치분산분석을 이용하였다. 결과: 먼저 weight technique에서 모델 스캔법으로 제작한 그룹에서 구강 내 스캔법으로 제작한 그룹에 비해 평균적인 무게 값이 낮게 나타났고, 이는 유의성이 있었다(P < .05). 또한, replica technique에서도 측정된 5개의 영역 모두에서 구강 내 스캔법으로 제작한 그룹에 비해 모델 스캔법으로 제작한 그룹에서 변연 및 내면의 gap에 대한 거리 값이 유의하게 낮게 나타났다(P < .05). 결론: 두 그룹의 방법으로 제작한 지르코니아 보철물은 모두 임상적으로 받아들여질 만한 변연 및 내면 적합성을 보였다. 하지만 모델 스캔법으로 제작한 그룹에서 구강 내 스캔법으로 제작한 그룹에 비해 높은 변연 및 내면 적합성을 보였다.

전자처리 스페클 패턴 간섭법(ESPI)을 이용한 3-유닛 고정성 국소의치의 변형특성 분석 (Deformation Characteristics Analysis of 3-Unit Fixed Partial Dentures by Using Electronic Speckle Pattern Interferometry)

  • 강후원;이철민;양승필;김희진
    • 대한치과기공학회지
    • /
    • 제35권1호
    • /
    • pp.49-56
    • /
    • 2013
  • Purpose: The deformation characteristics induced by non-destructive stresses using piezoelectric transducer(PZT) were analyzed for 3-unit fixed partial dentures manufactured PFM, Everest(CAD/CAM) and Zirkonzahn(copy milling, MAD/MAM) by electron speckle pattern interferometery(ESPI). Methods: The ESPI analysis after loading the restoration with PZT by applying electric voltage of 900mV at the points of 10 mm above the base of the prostheses. Results: PFM and All-Ceramic Everest prostheses showed about 0.1 ${\mu}m$ while that of All- Ceramic Zirkonzahn prostheses showed 0.085 ${\mu}m$, demonstrating that Zirkonzahn displaced less. For PFM and All-Ceramic Zirkonzahn prostheses, the displacements were large at just below the loading point, while generalize displacement was shown over the loading point and weak connector areas for All-Ceramic Everest prostheses. Conclusion: We could find that the deformation characteristics induced by non-destructive stresses using PZT analyzed by ESPI were similar to the fracture strengths evaluated using universal testing machine.

개의 기관에 적용한 변형제작한 기관외보철물의 평가 (Evaluation of Modified Extraluminal Prostheses Applied to the Trachea in Dogs)

  • 이충호;우흥명;권오경;남치주
    • 한국임상수의학회지
    • /
    • 제16권1호
    • /
    • pp.1-7
    • /
    • 1999
  • The purpose of the present study was to evaluate the easiness of suture and fixation of modified total ring prostheses (m-TRP). Twelve healthy dogs (B.W.2-10 kg) were randomly assigned to three groups. In group A (3 dogs), total ring prostheses was fixed by penetrating a suture material through tracheal mucosa. In group B (3 dogs), TRP was fixed by suturing on tracheal cartilage and muscular layer not penetrating through tracheal mucosa. m-TRP was applied to the cervical portions (group M-C,3 dogs), and thoracic portions (group M-T,3 dogs). Operating time of group M-C (37.33$\pm$6.80 min.) was shorter than those of groups B (83.33$\pm$8.50 min.) and A (63.33$\pm$11.06 min.) (p<0.01). Clinical complications were minimal and limited to mild, short-term hematoma, vomiting, edema, and inflammation. Coughing remarkably decreased in group B rather than group A. Dyspnea was not showed in group A, B, and M-C, but group M-T had a mild dyspnea. Gross postmortem findings were similar in all groups. Mild adhesions were present between prostheses and adjacent structures, but tracheal lumen was clean. Severe adhesions were present where m-TRP had been applied in the thoracic portions. Histopathologic abnormalities included mild to moderate adventitial and periprosthetic fibrosis and mild adventitial inflammation. The present study indicated that m-TRP were easier in suture and fixation than TRP and had no differences in support for trachea and side effects.

  • PDF

A root submergence technique for pontic site development in fixed dental prostheses in the maxillary anterior esthetic zone

  • Choi, Sunyoung;Yeo, In-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Cheong, Chan Wook;Han, Jung-Suk
    • Journal of Periodontal and Implant Science
    • /
    • 제45권4호
    • /
    • pp.152-155
    • /
    • 2015
  • Purpose: This case report discusses the effect of a root submergence technique on preserving the periodontal tissue at the pontic site of fixed dental prostheses in the maxillary anterior aesthetic zone. Methods: Teeth with less than ideal structural support for fixed retainer abutments were decoronated at the crestal bone level. After soft tissue closure, the final fixed dental prostheses were placed with the pontics over the submerged root area. Radiographic and clinical observations at the pontic sites were documented. Results: The submerged roots at the pontic sites preserved the surrounding periodontium without any periapical pathology. The gingival contour at the pontic site was maintained in harmony with those of the adjacent teeth, as well as the overall form of the arch. Conclusions: The results of this clinical report indicate that a root submergence technique can be successfully applied in pontic site development with fixed dental prostheses, especially in the maxillary anterior esthetic zone.

Optimization of Surface Treatment for Bonding S trength between Zirconia and Veneering Porcelain

  • Won, H.Y.;Kim, H.S.L.;Yun, C.H.;Son, M.K.;Cho, H.C.
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2012년도 춘계학술발표회 논문집
    • /
    • pp.332-332
    • /
    • 2012
  • All-ceramic prostheses are widely used to fulfill the high esthetic demand. However, bonding failure between zirconia and porcelain is one of the all-ceramic prostheses failures. In order to improve clinical sucess of all-ceramic prostheses, laboratory or in-office surface conditioning techniques on zirconia have been studied.

  • PDF

자연치와 임플란트 고정성보철에서 PAEK소재의 적용 (Dental application of Polyaryletherketone for fixed dental prostheses)

  • 이두형
    • 대한치과의사협회지
    • /
    • 제56권3호
    • /
    • pp.152-158
    • /
    • 2018
  • Polyaryletherketone (PAEK) is recently introduced in dentistry. The polymer has superior mechanical and chemical properties compared to previous dental materials. PAEK has been explored for lots of applications for clinical dentistry. The prostheses can be made by the injection molding or milling techniques. Recent studies focus on improving the bioactivity of PAEK and expanding the application. The purpose of this article is to introduce the basic features, chemical structure and various clinical applications in fixed dental prostheses. Further research and clinical trials will be needed to confirm the usability of PAEK in the routine practice.

  • PDF

변형제작한 기관외보철물을 이용한 기관허탈전 치료 1예 (Modified Extraluminal Prostheses Applied to the Canine Tracheal Collapse)

  • 이충호;권오경;남치주
    • 한국임상수의학회지
    • /
    • 제17권1호
    • /
    • pp.266-269
    • /
    • 2000
  • Tracheal collapse at the thoracic inlet is described in a 4 year-old female yorkshire terrier. The initial presenting signs included coughing, dyspnea, cyanosis and collapse. Diagnosis was based upon the clinical signs, physical examination, plain radiography and fluoroscopy. The collapse was corrected by the aplication of a neumber of modified total ring prostheses (m-TRP) applied to the cervical trachea. Clinical complicatons were minimal and limited to mild, short-term coughing. The present study indicated that m-TRP were easy to apply to tracheal collapse and were able to decrese clinical signs. Therefore, m-TRP may be applied to tracheal collapse as new prostheses.

  • PDF