• 제목/요약/키워드: Prostate

검색결과 1,256건 처리시간 0.024초

Determinants of Willingness to Undergo Lung Cancer Screening among High-Risk Current and Ex-smokers in Sabah, Malaysia: A Cross-Sectional Pilot Study

  • Larry Ellee Nyanti;Chia Zhen Chua;Han Chuan Loo;Cheng Zhi Khor;Emilia Sheau Yuin Toh;Rasvinder Singh Gill;Eng Tat Chan;Ker Yin Tan;Taufiq Rosli;Muhammad Aklil Abd Rahim;Arfian Ibrahim;Nai Chien Huan;Hema Yamini Devi Ramarmuty;Kunji Kannan Sivaraman Kannan
    • Tuberculosis and Respiratory Diseases
    • /
    • 제86권4호
    • /
    • pp.284-293
    • /
    • 2023
  • Background: Attitudes towards smoking, lung cancer screening, and perceived risk of lung cancer have not been widely studied in Malaysia. The primary objective of this study was to describe the factors affecting the willingness of high-risk current smokers and ex-smokers to undergo low-dose computed tomography (LDCT) screening for lung cancer. Methods: A prospective, cross-sectional questionnaire study was conducted in current smokers or ex-smokers aged between 55 and 80 years at three hospitals in Kota Kinabalu, Sabah, Malaysia. The questionnaire recorded the following parameters: perceived lung cancer risk; Prostate Lung Colon Ovarian Cancer 2012 risk prediction model excluding race and ethnicity predictor (PLCOm2012norace); demographic characteristics; psychosocial characteristics; and attitudes towards lung cancer and lung cancer screening. Results: A vast majority of the 95 respondents (94.7%) indicated their willingness to undergo screening. Stigma of lung cancer, low levels of knowledge about lung cancer symptoms, concerns about financial constraints, and a preference for traditional medication were still prevalent among the respondents, and they may represent potential barriers to lung cancer screening uptake. A desire to have an early diagnosis (odds ratio [OR], 11.33; 95% confidence interval [CI], 1.53 to 84.05; p=0.02), perceived time constraints (OR, 3.94; 95% CI, 1.32 to 11.73; p=0.01), and proximity of LDCT screening facilities (OR, 14.33; 95% CI, 1.84 to 111.4; p=0.01) had significantly higher odds of willingness to undergo screening. Conclusion: Although high-risk current smokers and ex-smokers are likely to undergo screening for lung cancer, several psychosocial barriers persist. The results of this study may guide the policymakers and clinicians regarding the need to improve lung cancer awareness in our population.

컴퓨터 단층촬영 영상에서 3번 요추부 슬라이스 검출을 위한 최적화 기반 딥러닝 모델 (Optimization-based Deep Learning Model to Localize L3 Slice in Whole Body Computerized Tomography Images)

  • 채성원;조재현;박예은;정진형;김성진;최안렬
    • 한국정보전자통신기술학회논문지
    • /
    • 제16권5호
    • /
    • pp.331-337
    • /
    • 2023
  • 본 논문에서는 근감소증의 발병 여부와 정도를 확인하기 위해 3번 요추부 (L3) CT 영상을 검출하는 딥러닝 모델을 제안하는 것이다. 또한, CT 데이터 내에 L3 레벨과 L3 레벨이 아닌 부분의 데이터 불균형으로 인한 성능 저하의 문제점을 오버샘플링 비율과 클래스 가중치를 설계변수로 하는 최적화 기법을 제시하고자 한다. 모델 학습 및 검증을 위하여 강릉아산병원에 내원한 전립선암 환자 104명, 방광암 환자 46명의 총 150명의 전신 CT 영상이 활용되었다. 딥러닝 모델은 ResNet50을 활용하였으며, 최적화기법의 설계변수로는 모델 하이퍼파라미터 5종과 데이터 증강비율 및 클래스 가중치로 선정하였다. 제안하는 최적화 기반의 L3 레벨 추출 모델은 대조군 (하이퍼파라미터 5종만을 최적화한 모델)과 비교하여 중간 L3 오차가 약 1.0 슬라이스 감소한 것을 확인할 수 있었다. 본 연구결과를 통하여 정확한 L3 슬라이스 검출이 가능하며, 추가적으로 데이터 증강을 통한 오버 샘플링과 클래스 가중치 조절을 통해 데이터 불균형 문제를 효과적으로 해결할 수 있는 가능성을 제시할 수 있다.

68Ga 표지 PET/CT 검사의 최적화된 매개변수에 대한 연구 (Study of 68Ga Labelled PET/CT Scan Parameters Optimization)

  • 곽인석;이혁;김시활;문승철
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.111-127
    • /
    • 2023
  • Purpose: Gallium-68 (68Ga) is increasingly used in nuclear medicine imaging for various conditions such as lymphoma and neuroendocrine tumors by labeling tracers like Prostate Specific Membrane Antigen (PSMA) and DOTA-TOC. However, compared to Fluorine-18 (18F) used in conventional nuclear medicine imaging, 68Ga has lower spatial resolution and relatively higher Signal to Background Ratio (SBR). Therefore, this study aimed to investigate the optimized parameters and reconstruction methods for PET/CT imaging using the 68Ga radiotracer through model-based image evaluation. Materials and Methods: Based on clinical images of 68Ga-PSMA PET/CT, a NEMA/IEC 2008 PET phantom model was prepared with a Hot vs Background (H/B) ratio of 10:1. Images were acquired for 9 minutes in list mode using DMIDR (GE, Milwaukee WI, USA). Subsequently, reconstructions were performed for 1 to 8 minutes using OS-EM (Ordered Subset Expectation Maximization) + TOF (Time of Flight) + Sharp IR (VPFX-S), and BSREM (Block Sequential Regularized Expectation Maximization) + TOF + Sharp IR (QCFX-S-400), followed by comparative evaluation. Based on the previous experimental results, images were reconstructed for BSREM + TOF + Sharp IR / 2 minutes (QCFX-S-2min) with varying β-strength values from 100 to 700. The image quality was evaluated using AMIDE (freeware, Ver.1.0.1) and Advanced Workstation (GE, USA). Results: Images reconstructed with QCFX-S-400 showed relatively higher values for SNR (Signal to Noise Ratio), CNR (Contrast to Noise Ratio), count, RC (Recovery Coefficient), and SUV (Standardized Uptake Value) compared to VPFX-S. SNR, CNR, and SUV exhibited the highest values at 2 minutes/bed acquisition time. RC showed the highest values for a 10 mm sphere at 2 minutes/bed acquisition time. For small spheres of 10 mm and 13 mm, an inverse relationship between β-strength increase and count was observed. SNR and CNR peaked at β-strength 400 and then decreased, while SUV and RC exhibited a normal distribution based on sphere size for β-strength values of 400 and above. Conclusion: Based on the experiments, PET/CT imaging using the 68Ga radiotracer yielded the most favorable quantitative and qualitative results with a 2 minutes/bed acquisition time and BSREM reconstruction, particularly when applying β-strength 400. The application of BSREM can enhance accurate quantification and image quality in 68Ga PET/CT imaging, and an optimization process tailored to each institution's imaging objectives appears necessary.

화살나무 날개 추출물의 생리활성 (Biological activity of Euonymus alatus (Thunb.) Sieb. wing extracts)

  • 민혜지;김두현;서권일
    • 한국식품저장유통학회지
    • /
    • 제30권2호
    • /
    • pp.358-368
    • /
    • 2023
  • 본 연구에서는 화살나무 날개를 이용하여 물, 에탄올 및 메탄올을 이용하여 얻은 추출물을 이용하여 항산화 활성, 항당뇨 활성, 총폴리페놀 및 플라보노이드 함량, 암세포 성장 억제능을 평가하였다. 화살나무 날개 추출물은 DPPH radical 소거능 결과에서는 에탄올과 메탄올 추출물에서 positive control과 유사한 radical 소거능을 나타내었으며 ABTS·+ radical 소거능에서는 모든 군의 1,000 ㎍/mL의 농도에서 80% 이상의 소거능을 보여주었다. 또한, 환원력과 hydrogen peroxide 소거능 및 α-glucosidase 저해활성에서 에탄올과 메탄올 추출물은 positive control과 비슷하거나 높은 활성을 나타내었다. 화살나무 날개 추출물 내 총폴리페놀 및 플라보노이드 함량은 에탄올 추출물에서 867.8 mg% 및 551.7 mg%로 물 및 메탄올 추출물과 비교하였을 때 보다 높은 총폴리페놀 및 플라보노이드 함량이 확인되었다. 화살나무 날개 추출물의 암세포 증식 억제 활성은 흑색종 피부암(B16)에서는 큰 효과를 확인할 수 없었지만 유방암(MDA-MB-231), 대장암(HT-29) 및 전립선암(LNCaP)에서는 유의적인 세포 생존 억제능을 확인하였고 특히 LNCaP에 에탄올 추출물을 처리하였을 때 19.1%의 세포 생존율을 보이며 가장 우수한 세포 성장 억제 활성을 확인하였다. 또한, 전립선 정상 세포인 RWPE-1을 화살나무 날개 추출물로 처리하였을 때 세포 생존율에 큰 영향을 받지 않았기 때문에 암세포 특이적인 성장 억제 활성을 확인할 수 있었다. 이러한 결과를 통해 풍부한 폴리페놀 및 플라보노이드 함량을 가진 화살나무 추출물은 항산화, α- glucosidase 억제, 항암 효과를 나타내어 뛰어난 생리활성효능을 가지고 있고, 이는 효과적인 천연물 유래 기능성 원료 및 식품 소재 발굴을 위한 기초자료로 이용할 수 있을것으로 사료된다.

고체상 추출법을 기반으로 한 [18F]Fluorocholine 합성법의 최적화 연구 (Optimization of Automated Solid Phase Extraction-based Synthesis of [18F]Fluorocholine)

  • 박준영;손정민;강원준
    • 대한임상검사과학회지
    • /
    • 제55권4호
    • /
    • pp.261-268
    • /
    • 2023
  • [18F]Fluorocholine은 임상에서 부갑상선 선종, 전립선암 및 간세포암 진단 등에 사용되는 PET용 콜린 방사성의약품이다. 본 연구에서는 고체상 추출 카트리지법을 방사성의약품 자동합성장치에 적용하여 [18F]fluorocholine을 제조하는 방법을 최적화하였다. [18F]Fluorocholine은 하나의 반응용기를 사용하여 두 단계 표지반응으로 합성하였으며, [18F]fluorocholine 합성과정 중 생성되는 불순물을 제거하기 위해 사용하는 SepPak Silica 카트리지의 개수를 3개로 최적화하였고, 전구 물질인 DMAE를 10%로 희석하였을 때 가장 높은 방사화학적 수율을 획득 할 수 있었다. 또한 최종 생산된 [18F] fluorocholine 주사액은 유럽약전에 명시된 품질관리기준을 모두 만족하였다. 본 연구를 통해 쉽고 간편하게 사용할 수 있는 고체상 추출 카트리지를 사용하여 방사성의약품 자동합성장치에 최적화한 [18F]fluorocholine의 합성법은 임상 현장에 안정적으로 [18F]fluorocholine을 공급하는데 유용하게 사용될 것으로 사료된다.

Prostatic Artery Embolization for Lower Urinary Tract Symptoms via Transradial Versus Transfemoral Artery Access: Single-Center Technical Outcomes

  • Ryun Gil;Dong Jae Shim;Doyoung Kim;Dong Hwan Lee;Jung Jun Kim;Jung Whee Lee
    • Korean Journal of Radiology
    • /
    • 제23권5호
    • /
    • pp.548-554
    • /
    • 2022
  • Objective: To evaluate the safety and feasibility of prostatic artery embolization (PAE) via transradial access (TRA) compared with transfemoral access (TFA). Materials and Methods: This retrospective study included 53 consecutive men with lower urinary tract symptoms (LUTS) who underwent PAE between September 2018 and September 2021. Thirty-one patients (mean age ± standard deviation: 70.6 ± 8.4 years) were treated with TFA, including 14 patients treated before adopting TRA. Since December 2019, TRA has also been attempted with the procedure's selection criteria of patent carpal circulation and a height ≤ 172 cm, with 22 patients treated via TRA (69.1 ± 9.6 years). Parameters of technical success (defined as successful bilateral embolization), clinical success (defined as LUTS improvement), procedural time, radiation dose, and adverse events were compared between the two groups using the Fisher's exact test, independent sample t test, Wilcoxon signed-rank test, or Mann-Whitney test. Results: All patients received at least one-side PAE. Technical success of PAE was achieved in most patients (TRA, 21/22; TFA, 30/31; p > 0.999). No technical problem-related conversion from TRA to TFA occurred. The clinical success rate was 85% (11/13) in patients with TRA, and 89% (16/18) in patients with TFA for follow-up > 2 weeks post-PAE (median, 3 months) (p > 0.999). The median procedure time was similar in both groups (TRA, 81 minutes vs. TFA, 94 minutes; p = 0.570). No significant dose differences were found between the TRA and TFA groups in the dose-area product (median Gycm2, 95 [range, 44-255] for TRA and 84 [34-255] for TFA; p = 0.678) or cumulative air kerma (median mGy, 609 [236-1584] for TRA and 634 [217-1594] for TFA; p = 0.551). No major adverse events occurred in either of the groups. Conclusion: PAE via TRA is a safe and feasible method comparable to conventional TFA. It can be safely implemented by selecting patients with patent carpal circulation and adequate height.

누락된 공변량을 가진 원인별 비례위험모형의 분석 (Analysis of the cause-specific proportional hazards model with missing covariates)

  • 이민정
    • 응용통계연구
    • /
    • 제37권2호
    • /
    • pp.225-237
    • /
    • 2024
  • 경쟁위험자료에서 일부 공변량들이 연구대상들의 일부분에 대해 관측되지 않을 수 있다. 그런 경우 결측된 공변량 값을 가진 연구대상들을 분석에서 제외하는 것은 편향된 추정치와 효율성 손실이 발생할 수 있다. 본 논문에서는 누락된 공변량을 가진 원인별 비례위험모형의 회귀모수 추정을 위해 다중대체 방법과 증대된 역 확률 가중 방법을 연구하였다. 모의실험을 통해 다중대체 방법과 증대된 역 확률 가중 방법에 의해 구해진 추정량의 성능을 평가한 결과, 이 방법들이 잘 수행됨을 확인하였다. 미국 국립암연구소의 전립선, 폐, 대장, 난소 암 선별 시험 연구에서 제공하는 종양 크기의 값이 누락된 유방암 자료에 대해 암 사망 위험률과 다른 원인 사망 위험률에 유의한 영향을 미치는 요인을 파악하기 위해 다중대체 방법과 증대된 역 확률 가중 방법을 적용하였다. 다중대체 방법과 증대된 역 확률 가중 방법에 의해 원인별 비례위험모형을 적합한 결과, 인종, 기혼여부, 병기, 분화도, 종양의 크기는 유방암 사망 위험률에 유의한 영향을 미치는 요인들이였으며, 병기가 유방암 사망 위험률을 높이는데 가장 큰 영향을 미치는 요인임을 확인하였다. 진단시 연령과 종양의 크기는 다른 원인 사망 위험률을 높이는데 유의한 영향을 미치는 요인이였다.

팬텀연구에서 경직장 전단파탄성초음파의 가변성 (Variability of Transrectal Shear Wave Elastography in a Phantom Model)

  • 이지현;윤성국;조진한;권희진;김동원;이준우
    • 대한영상의학회지
    • /
    • 제84권5호
    • /
    • pp.1110-1122
    • /
    • 2023
  • 목적 본 연구는 제작한 팬텀을 사용해 경직장 전단파탄성초음파의 가변성을 알아보았다. 대상과 방법 아가로즈와 실리콘에멀전을 각각 1, 2, 3 cm 크기의 둥근 모양과 사각 모양의 팬텀 물질로 제작하였다. 1, 2, 3 cm의 깊이에 팬텀을 놓고, 크기, 깊이, 모양에 따른 굳기값(coefficient variant)의 차이를 중심부/주변부에서 확인하였다. 두 명의 영상의가 경직장 초음파 탐촉자를 이용해 각각 3회씩, 두 개의 초음파기계로(기계 A, B), 굳기값을 확인하였다. 가변성은 변동계수로 표현하였다. 결과 팬텀의 크기가 커질수록 변동계수는 감소하였다. 크기에 따른 굳기값은, 아가로즈 팬텀은 기계 A 3 cm 깊이(p < 0.001), 기계 B 1 cm 깊이에서(p = 0.010), 실리콘에멀전 팬텀은 2 cm 깊이에서 두 기계 모두 유의한 차이를 보였다(p = 0.047, p = 0.020). 깊이가 깊어질수록 변동계수는 증가하였다. 깊이에 따른 굳기값은, 1 cm 크기 아가로즈 팬텀은 두 기계 모두(p = 0.037, p = 0.021), 2 cm 크기 아가로즈 팬텀은 기계 A에(p = 0.047) 유의한 차이를 보였다. 기계 A 실리콘에멀전에서만 모양에 따른 굳기값의 유의한 차이를 보였고(p = 0.032) 기계 B는 두 물질 모두 관심영역에 따른 굳기값의 유의한 차이가 보였다. 굳기값은 두 기계 간 유의한 차이가 있었고(p < 0.05), 시술자 내/시술자 간 일치도는 높았다(급내상관계수 > 0.9). 결론 팬텀의 크기, 깊이, 사용된 기계가 전단파탄성초음파 가변성에 영향을 주는 요소로 나타났다.

Why Is a b-value Range of 1500-2000 s/mm2 Optimal for Evaluating Prostatic Index Lesions on Synthetic Diffusion-Weighted Imaging?

  • So Yeon Cha;EunJu Kim;Sung Yoon Park
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.922-930
    • /
    • 2021
  • Objective: It is uncertain why a b-value range of 1500-2000 s/mm2 is optimal. This study was aimed at qualitatively and quantitatively analyzing the optimal b-value range of synthetic diffusion-weighted imaging (sDWI) for evaluating prostatic index lesions. Materials and Methods: This retrospective study included 92 patients who underwent DWI and targeted biopsy for magnetic resonance imaging (MRI)-suggested index lesions. We generated sDWI at a b-value range of 1000-3000 s/mm2 using dedicated software and true DWI data at b-values of 0, 100, and 1000 s/mm2. We hypothesized that lesion conspicuity would be best when the background (i.e., MRI-suggested benign prostatic [bP] and periprostatic [pP] regions) signal intensity (SI) is suppressed and becomes homogeneous. To prove this hypothesis, we performed both qualitative and quantitative analyses. For qualitative analysis, two independent readers analyzed the b-value showing the best visual conspicuity of an MRI-suggested index lesion. For quantitative analysis, the readers assessed the b-value showing the same bP and pP region SI. The 95% confidence interval (CI) or interquartile range of qualitatively and quantitatively selected optimal b-values was assessed, and the mean difference between qualitatively and quantitatively selected b-values was investigated. Results: The 95% CIs of optimal b-values from qualitative and quantitative analyses were 1761-1805 s/mm2 and 1640-1771 s/mm2 (median, 1790 s/mm2 vs. 1705 s/mm2; p = 0.003) for reader 1, and 1835-1895 s/mm2 and 1705-1841 s/mm2 (median, 1872 s/mm2 vs. 1763 s/mm2; p = 0.022) for reader 2, respectively. Interquartile ranges of qualitatively and quantitatively selected optimal b-values were 1735-1873 s/mm2 and 1573-1867 s/mm2 for reader 1, and 1775-1945 s/mm2 and 1591-1955 s/mm2 for reader 2, respectively. Bland-Altman plots consistently demonstrated a mean difference of less than 100 s/mm2 between qualitatively and quantitatively selected optimal b-values. Conclusion: b-value range showing a homogeneous background signal may be optimal for evaluating prostatic index lesions on sDWI. Our qualitative and quantitative data consistently recommend b-values of 1500-2000 s/mm2.

핵의학 체외검사실에서 시약 lot간 parallel test 시 변이 분석 (Analysis of Variation for Parallel Test between Reagent Lots in in-vitro Laboratory of Nuclear Medicine Department)

  • 채홍주;천준홍;이선호;유소연;유선희;박지혜;임수연
    • 핵의학기술
    • /
    • 제23권2호
    • /
    • pp.51-58
    • /
    • 2019
  • 핵의학 체외 검사실 에서는 시약 Lot가 변경될 때, Lot 간의 결과가 신뢰성이 있는지를 판단하기 위해 Lot 간 동등성 검사(comparability test between reagent lots) 또는 시약 병행 검사(reagent parallel test)를 시행하는데, 다수의 국내 검사실에서는 두 lot 간 결과 차이로부터 %difference를 구하여 저농도에서는 20% 이내, 중 고농도에서는 10% 이내로 설정하고 있으며 범위를 벗어 날 경우 재검사 시행으로 범위를 맞추는 실정이다. 따라서 본원의 핵의학 체외 검사실에서 시행되는 몇 가지 검사를 선정하여 parallel test의 결과를 분석해보았고, 검사별 맞춤 %difference 값 선정에 도움 될 만한 참고 자료를 마련해 보고자 하였다. Thyroid-stimulating hormone(TSH), Free thyroxine(FT4), Carcinoembryonic antigen(CEA), CA-125, Prostate-specific antigen(PSA) 그리고 HBs-Ab, insulin, 7종목에 대해 2018 1월부터 2018년 11월까지의 기간 동안의 시약 lot 변화에 따른 정도 관리 물질의 결과를 분석하였다. TSH, F-T4, CEA, CA-125, PSA의 측정에는 IRMA의 원리를 이용한 RIA-MAT 280 system이 사용되었고, Insulin의 측정에는 TECAN 자동화 분주 장비와 GAMMA-10 측정 장비가 사용되었다. HBs-Ab의 측정에는 HAMILTON 자동화 분주 장비와 GAMMA-10 측정 장비가 사용되었다. 각각 전용 시약과 전용 칼리브레이터, 전용 정도 관리 물질이 사용되었다. 1. TSH [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(저농도) [14.8 / 4.4 / 3.7 / 0.0 ] C-2(중농도) [10.1 / 4.2 / 3.7 / 0.0] 2. FT4 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(저농도) [10.0 / 4.2 / 3.9 / 0.0] C-2(고농도) [9.6 / 3.3 / 3.1 / 0.0 ] 3. CA-125 [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(중농도) [9.6 / 4.3 / 4.3 / 0.3] C-2(고농도) [6.5 / 3.5 / 4.3 / 0.4] 4. CEA [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(저농도) [9.8 / 4.2 / 3.0 / 0.0] C-2(중농도) [8.7 / 3.7 / 2.3 / 0.3] 5. PSA [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(저농도) [15.4 / 7.6 / 8.2 / 0.0] C-2(중농도) [8.8 / 4.5 / 4.8 / 0.9] 6. HBs-Ab [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(중농도) [9.6 / 3.7 / 2.7 / 0.2] C-2(고농도) [8.9 / 4.1 / 3.6 / 0.3] 7. insulin [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(중농도) [8.7 / 3.1 / 2.4 / 0.9] C-2(고농도) [8.3 / 3.2 / 1.5 / 0.1] 모두 정도 관리 물질의 lot 변경 시에도 유의미한 차이가 없었으며 표본 수가 늘어남에 따라 검사실과 검사 종목 별 맞춤 허용 기준을 설정할 수 있을 것이라 기대할 수 있었다. 면역 방사 계수 측정법에서 비교적 검출률이 높은 종목들을 선정해서 일 것이라 판단되며 여러 번 재 측정된 결과 값이기 때문일 수도 있겠다. 대부분의 검사 결과에서 허용 기준인 10%에 크게 못 미치는 차이를 보였으며 저농도 target 값을 가진 경우에도 허용 기준인 20%에 가까운 수치를 보이진 않았다. 더 오랜 기간 동안의 관찰과 연구를 통해 평균의 균질화가 이루어진다면 종목 별 검사실 맞춤 허용 기준을 얻을 수 있을 것으로 판단되며 더 다양한 변수를 고려한 관찰과 연구도 필요할 것이다.