• 제목/요약/키워드: Proposal of design formula

검색결과 19건 처리시간 0.023초

저층건축물의 구조골조 설계용 풍압계수 및 풍하중 평가 약산식의 제안 (A Proposal of the Wind Pressure Coefficient and Simplified Wind Load Estimating Formula for the Design of Structural Frames of the Low-Rise Buildings)

  • 박재형;정영배;하영철
    • 한국강구조학회 논문집
    • /
    • 제21권3호
    • /
    • pp.289-299
    • /
    • 2009
  • 본 연구는 각주형 저층건축물에 작용하는 지점별 풍압을 다점동시측정시스템을 이용하여 건물 폭과 깊이변화에 따른 평균풍압분포 특성에 대한 기초적인 결과를 정리한 것이다. 본 실험에서는 건물의 폭과 깊이를 변화시킨 5개의 각주형 풍압실험모형이 사용되었으며, 풍동실험은 금오공과대학교 소재 토출식 경계층풍동에서 실시하였다. 실험결과는 저층건축물의 건물 폭 및 깊이의 변화에 따른 저층건축물의 평균풍압분포 변화경향을 건축물의 풍상면, 풍측면 및 풍하면 중심으로 특성을 분석하였다. 실험결과를 토대로 저층건축물의 구조골조 설계용 풍하중을 합리적으로 산정하기 위해 필요한 새로운 풍압계수 및 간략한 약산식을 제시하였다.

Proposal for the Development of the Livestock 6th Industrial Producers Improvement Index Based on the Kano Model

  • Yang, Hoe-Chang;Kim, Hwa-Kyung
    • 동아시아경상학회지
    • /
    • 제5권4호
    • /
    • pp.67-74
    • /
    • 2017
  • Purpose - The main purpose of this study is to contribute to the elevation of producers' production at various levels by proposing the creation of producer improvement indexes that can be used for the successful 6th industrialization of Korean agribusiness based on the Kano model and has synergistic effects on the development of the 6th industry through scientific researches. Research design, data, methodology - To this end, this study derived better and worse index from the same estimation of Timko's customer satisfaction index as in the evaluation charts used in previous researches and theoretical studies on the Kano model. Results - In this paper, we suggested that the formula for producing PSCI Index be applied to yield the producer improvement index in the 6th industry, in order to draw SIPPI. Conclusions - If this suggestion is realized, then a lot of researchers will be supported to more systematically study producers, and it is expected to contribute to the development of the 1th industry, a basis for the successful 6th industry. Moreover, the central government and municipalities are expected to provide a variety of clues for applying various policies for successful agribusiness.

탄성받침의 강성특성에 대한 실험연구 (A Experimental Study on the Stiffness Characteristics of Elastomeric Bearings)

  • 윤혜진;조창백;김영진;곽임종
    • 대한토목학회논문집
    • /
    • 제28권4A호
    • /
    • pp.475-485
    • /
    • 2008
  • 이 논문은 국내 탄성받침의 성능과 신뢰성 향상을 위한 일환으로, 탄성받침의 설계/제작/품질평가 기준인 KS F 4420의 강성 관련 개선방향을 제안하였다. 이를 위하여 KS F 4420의 압축탄성계수, 강성측정방법, 성능평가방법을 Eurocode, 일본 도로교지승편람, ISO 기준과 비교 분석하였으며, KS F 4420의 강성 제안식과 실측치와의 차이를 알아보기 위하여 국내 일반적인 탄성받침을 대상으로 수직강성과 전단강성 측정 실험을 실시하였다. 실측된 수직강성은 강성정의 방법에 따라 20%정도 차이를 나타냈으며, 전단강성은 13%정도 차이를 나타냈다. 또한 실측된 강성은 KS F 4420의 제안식과의 편차도 큰 것으로 나타났다. 교량받침이 요구되는 수직강성을 가지지 못하는 경우 교량 상부 구조물의 부등침하 및 응력집중 현상을 야기할 수 있다. 따라서 국내 받침이 설계에서 요구되는 성능을 갖기 위해서는 다양한 형상, 형상계수를 갖는 받침의 성능평가를 통하여 국내 실정에 맞는 압축탄성계수식과 성능평가기준의 마련이 필요하다고 판단된다.

파랑하중에 대한 인터로킹 케이슨 방파제의 미끌림 안정성 평가식 제안 (Proposal of Sliding Stability Assessment Formulas for an Interlocking Caisson Breakwater under Wave Forces)

  • 박우선;원덕희;서지혜
    • 한국해안·해양공학회논문집
    • /
    • 제29권2호
    • /
    • pp.77-82
    • /
    • 2017
  • 기후변화에 따른 설계파고를 초과하는 이상파랑의 내습 가능성이 커지면서 항만구조물의 안정성 확보가 시급한 실정이다. 이러한 변화에 능동적으로 대응하기 위하여 기존 방파제에 대한 평가기준과 신설 장대형 방파제의 설계기준이 점차 강화되면서 인터로킹 케이슨 방파제에 대한 관심이 대두되고 있다. 하지만 현재까지는 항만 및 어항 설계기준 해설[부록] 개정안에 장대형 케이슨에 발생하는 파력 평활화 효과가 제시되어있을 뿐 인터로킹 케이슨 방파제의 안정성을 평가하기 위한 방법이 별도로 제시되어 있지 않다. 이에, 본 연구에서는 선형파 이론에 기초하여 경사 입사하는 파랑의 작용 위치별 위상차의 효과를 고려하고, 최대 파력분포는 설계기준의 Goda 파압식을 적용하여, 규칙파, 불규칙파 및 다방향 불규칙파에 대한 인터로킹 케이슨 방파제의 미끌림 안정성 평가식을 제안하였다.

Rating of steel bridges considering fatigue and corrosion

  • Lalthlamuana, R.;Talukdar, S.
    • Structural Engineering and Mechanics
    • /
    • 제47권5호
    • /
    • pp.643-660
    • /
    • 2013
  • In the present work, the capacity ratings of steel truss bridges have been carried out incorporating dynamic effect of moving vehicles and its accumulating effect as fatigue. Further, corrosion in the steel members has been taken into account to examine the rating factor. Dynamic effect has been considered in the rating procedure making use of impact factors obtained from simulation studies as well as from codal guidelines. A steel truss bridge has been considered to illustrate the approach. Two levels of capacity ratings- the upper load level capacity rating (called operating rating) and the lower load level capacity rating (called inventory rating) were found out using Load and Resistance Factor Design (LRFD) method and a proposal has been made which incorporates fatigue in the rating formula. Random nature of corrosion on the steel member has been taken into account in the rating by considering reduced member strength. Partial safety factor for each truss member has been obtained from the fatigue reliability index considering random variables on the fatigue parameters, traffic growth rate and accumulated number of stress cycle using appropriate probability density function. The bridge has been modeled using Finite Element software. Regressions of rating factor versus vehicle gross weight have been obtained. Results show that rating factor decreases when the impact factor other than those in the codal provisions are considered. The consideration of fatigue and member corrosion gives a lower value of rating factor compared to those when both the effects are ignored. In addition to this, the study reveals that rating factor decreases when the vehicle gross weight is increased.

지관 플레이트가 주관에 용접된 각형강관 접합부의 설계내력 평가에 관한 연구 (Evaluation of Design Formulae for T-joints on the Branch Plate and Hollow Steel Sections welded connections)

  • 박금성;배규웅;문태섭
    • 한국강구조학회 논문집
    • /
    • 제17권5호통권78호
    • /
    • pp.581-591
    • /
    • 2005
  • 본 논문의 목적은 지관이 종방향 플레이트인 냉간성형 각형강관 T형 접합부의 최대내력 평가를 통하여 설계내력식을 제안하는 것이다. 이러한 T형 접합부의 형상은 지관에 플레이트를 이용하여 각형강관 주관면에 길이방향으로 용접하는 형상이고, 지관 플레이트를 갖는 각형강관 T형 접합부 실험결과 중에서 주관 플랜지 휨파괴가 지배하는 접합부만을 대상으로 하였다. $16.7{\leq}2{\gamma}(B/T){\leq}31.3$ 이고 $0.20{\leq}{\beta}(b1/B){\leq}0.75$ 범위의 지관 플레이트를 갖는 T형 접합부에 대하여, 접합부의 내력은 강도보다는 사용성이 지배하는 나타나 최대내력을 주관폭(B)의 1.5 P1%B로 정의하였다. 기본 접합부 형상에 대해 제안된 항복선모델을 참조하여 지관 플레이트를 갖는 접합부 형상에 대한 새로운 수정된 항복선 모델을 제안하였다. 최종적으로 유한요소해석과 항복선 해석에 근거한 제안 설계내력식과 실험결과를 비교하여 타당성을 검증하였다.

Spline보간법을 이용한 토공량결정에 관한 연구 (A Study on the Earthwork Volume Decision using the Spline Interpolation)

  • 문두열
    • 한국측량학회지
    • /
    • 제18권3호
    • /
    • pp.305-313
    • /
    • 2000
  • 건설시공현장에서 토공량결정은 전체공사비 중에 큰 비중을 차지하므로 정확한 계산방법이 있어야 한다 토공량을 계산하는 현행방법은 격자점사이의 횡단면의 간격을 선형 (사다리꼴법칙)이나 비선형(심프슨법칙)으로 가정한다. 일반적으로 비선형법칙이 선형법칙보다 더 정확한 것으로 나타나 있다. 그러나 앞에서 언급된 모든 방법은 예리한 코너부분이나 두점 사이의 갑작스런 지형변화에 대처할 수 없는 결점을 내포하고 있다. 본 연구에서는 일정 구역의 양방향에 splin법을 적용한 식을 구하였으며, 점고법, Chamber법, 그리고 Chen과 Lin법을 서로 비교하였다. 그 결과 제시된 방법은 기존의 방법들 보다 더 정확하였다. 또한, 제시된 수학적모델법은 현행식들의 정확도 평가에 기준이 된다.

  • PDF

철도 교각의 세굴 안정성 평가를 위한 응답 지배주파수 분석 (Response Dominant Frequency Analysis for Scour Safety Evaluation of Railroad Piers)

  • 정현석;이명재;유민택;이일화
    • 한국지반공학회논문집
    • /
    • 제36권11호
    • /
    • pp.83-95
    • /
    • 2020
  • 철도 교량 하부구조의 안정성 평가를 위해 일련의 충격진동시험을 수행하고, 계측된 가속도 시간이력 데이터를 분석하여 응답 지배주파수를 산정하였다. 실험 교각의 제원은 준공설계 자료를 참고하였으며 자료가 소실된 경우에는 현장 조사를 시행하여 확보하였다. 1개의 폐선 예정 교각에서 세굴 진행에 따른 충격진동시험을 수행하고, 이를 바탕으로 교각의 응답 지배주파수가 교각의 세굴 여부에 대한 평가 지표로 적용 가능한 것을 확인하였다. 또한, 실제 운영 중인 5개 교량 46개 교각에서 충격하중시험을 통해 응답 지배주파수를 산정하였으며, 이를 일본 기준식과 비교하여 교량의 세굴 안정성을 평가하였다.

실무 적용성이 용이한 간편 유속 산정식 제안 (A Proposal for Simplified Velocity Estimation for Practical Applicability)

  • 추태호;서종철;최현구;전근학
    • 한국습지학회지
    • /
    • 제25권2호
    • /
    • pp.75-82
    • /
    • 2023
  • 하천의 유량 측정 자료는 수자원의 개발 및 유지, 하천 방재의 중요한 기초 자료로 이용되며, 홍수를 예측하고 예방하기 위해 홍수시 가장 정확하게 유량을 측정하는 것이 필요하다. 이에 미국지질조사국(USGS)은 오래전부터 기존의 간편 유속측정법으로 1점법, 2점법, 3점법을 제안하여 지금도 많이 사용하고 있으나, 보다 더 간편하고 신뢰할 수 있는 평균유속 산정 방법을 실무에서 요구하는 추세이나 이에 대한 이론적 기반의 실무 적용성 연구는 다소 미진한 상태이다. 이를 위하여 본 연구에서는 확률론적 엔트로피 컨셉을 활용하여 기존의 한계를 보완할 수 있는 실무 적용성이 용이한 간편 유속 산정식을 제안하였다. Coleman과 Flume 실측자료에 적용하여 식의 효용성을 입증하였다. 분석 결과, Flume Data의 경우, 실측값 대비 기존의 USGS 1점법은 평균 7.6%, 2점법은 8.6%, 3점법은 8.1%였다. Coleman Data의 경우, 1점법은 평균 5%, 2점법은 5.6%, 3점법은 5.3%의 오차율을 나타냈다. 반면에 엔트로피 개념을 활용한 제안식은 Flume Data는 실측값 대비 1점법은 평균 4.7%, 2점법은 5.7%, 3점법은 5.2%로 나타나 기존의 방법 대비 오차율을 약 60%정도 감소하는 것으로 나타났다. 또한, Coleman Data의 경우에서도 1점법은 평균 2.5%, 2점법은 3.1%, 3점법은 평균 2.8%의 오차를 보여, 기존의 방법 대비 오차율을 약 50%정도 줄이는 것으로 나타났다. 본 연구 결과에 의하면 기존의 1점법, 2점법, 3점법 보다 더 간편하면서 신뢰성 있는 평균유속을 산정할 수 있을 것으로 판단 된다. 하지만, 이는 향후 하천 설계, 운영관리, 특히 재난대비 예측관리 등 각종재난 대비 대응에 보다 유용하게 활용하려면 추가적으로 다양한 하천 실측을 통한 제안식의 지속적인 수정보완이 필요할 것으로 판단된다.