• Title/Summary/Keyword: Property Variation

Search Result 821, Processing Time 0.037 seconds

Evaluation of Permeability on Construction Material in CFRD Bedding Zone (CFRD Bedding Zone의 축조재료에 대한 투수성 평가)

  • Han, Sang-Hyun;Yea, Geu-Guwen
    • The Journal of Engineering Geology
    • /
    • v.19 no.4
    • /
    • pp.493-499
    • /
    • 2009
  • Recently, the construction of Concrete Faced Rockfill Dam (CFRD) is increasing because rock material resources are plenty in Korea. Bedding zone in the CFRD is necessary enough bearing capacity to support the concrete face slab uniformly and enough impermeability to prevent the loss of fine soils in case of leakage from the concrete slab face. Therefore, cut-off the water leakage in bedding zone securely is the key factor influencing the safety of CFRD. Tested materials satisfied with the specification of particle size distribution at the Bedding Zone area are chosen for conducting permeability tests, which are done to evaluate the property of cut off the materials. Based on the test results, the effects of cut off the materials are investigated by considering the coefficient of permeability, the soil particle distribution, and the dry unit weight. Especially, the relationships between coefficient of permeability with effective size(D10), dry unit weight, and weight passing percent the No.4 sieve are suggested, and also the variation of coefficient of permeability with time are proposed.

Preparation of Anion Exchange Membranes of Cross-linked Poly((vinylbenzyl)trimethylammonium chloride-2-hydroxyethyl methacrylate)/Poly(vinyl alcohol) (가교결합한 Poly((vinylbenzyl)trimethylammonium chloride-2-hydroxyethyl methacrylate)/poly(vinyl alcohol) 음이온 교환막 제조)

  • Kim, Mi-Yang;Kim, Kwang-Je;Kang, Ho
    • Applied Chemistry for Engineering
    • /
    • v.21 no.6
    • /
    • pp.621-626
    • /
    • 2010
  • Anion exchange membranes can be used for reverse electrodialysis for electric energy generation, and capacitive deionization for water purification, as well as electrodialysis for desalination. In this study, anion exchange membranes of poly((vinylbenzyl) trimethylammonium chloride-2-hydroxyethyl methacrylate)/poly(vinyl alcohol) were prepared through the polymerization of (vinylbenzyl)trimethylammonium chloride and 2-hydroxyethyl methacrylate in aqueous poly(vinyl alcohol) solutions, esterification with glutaric acid, and cross-linking reaction with glutaraldehyde. We investigated electrochemical properties for the anion exchange membranes prepared according to experimental conditions. Ion exchange capacity and electrical resistance for the membranes were changed with a variation in the monomer ratio in polymerization. Water uptake and conductivity for the membranes decreased with an increase in the content of glutaric acid in esterification. The change in the time of crosslinking reaction with the formed film and glutaraldehyde affected electrochemical properties such as water uptake, conductivity, or transport number for the membranes. Chronopotentiometry and limiting current density for the anion exchange membranes prepared were measured.

Effect of Glass Composition on the Optical Properties of Color Conversion Glasses for White LED (유리조성에 따른 백색 LED용 색변환 유리의 광특성)

  • Huh, Cheolmin;Hwang, Jonghee;Lim, Tae-Young;Kim, Jin-Ho;Lee, MiJai;Yoo, Jong-Sung;Park, Tae-Ho;Moon, Jooho
    • Korean Journal of Materials Research
    • /
    • v.22 no.12
    • /
    • pp.669-674
    • /
    • 2012
  • Yellow phosphor dispersed color conversion glasses are promising phosphor materials for white LED applications because of their good thermal durability, chemical stability, and anti-ultraviolet property. Six color conversion glasses were prepared with high Tg and low Tg specimens of glass. Luminous efficacy, luminance, CIE (Commission Internationale de l'Eclairage) chromaticity, CCT (Correlated Color Temperature), and CRI (Color Rendering Index) of the color conversion glasses were analyzed according to the PL spectrum. Color conversion glasses with high Tg glass frit, sintered at higher temperature, showed better luminous properties than did color conversion glasses with low Tg glass frit. The characteristics of the color conversion glass depended on the glass composition rather than on the sintering temperature. The XRD peaks of the YAG phosphor disappeared in the color conversion glass with major components of $B_2O_3$-ZnO-$SiO_2$-CaO and, in the XRD results, new crystalline peaks of $BaSi_2O_5$ appeared in the color conversion glass with major components of $Bi_2O_3$-ZnO-$B_2O_3$-MgO. The characteristics of CIE chromaticity, CCT, and the CRI of low Tg color conversion glasses showed worse color properties than those of high Tg color conversion glasses. However, these color characteristics of low Tg glasses were improved by thickness variation. So color conversion glasses with good characteristics of both luminous and color properties were attained.

The effect of zeolite addition on floc in activated sludge process (제올라이트 주입이 활성슬러지 플럭에 미치는 영향)

  • Lee, Hyung Sool;Park, se Jin;Yoon, Tae Il
    • Clean Technology
    • /
    • v.7 no.1
    • /
    • pp.35-42
    • /
    • 2001
  • This study was performed to evaluate the effect of zeolite addition on biofloc in aictvated sludge process. Two units were compared each other, in which one was operated as control unit (CU) and the other was managed by adding zeolite into aeration basin to sustain 4,000 mg/l (ZU). It was observed that flocs of both units were enduringly increased in medium size by extending SRT (Solid Retention Time), although their effect size of ZU was smaller than theirs of CU. Zeolite application excessively improved sludge settling property and ZU presented sludge settling velocity of 3.4 to 11 m/h regardless of SRT variation. The sludge volume index (SVI) was in the range of 50 and 108 ml/g. Conversely, the sludge settling velocity of CU seriously depended on SRT increase, and sludge sedimentation was not achieved at a 40 days of SRT due to Sphaerotilus appeared predominantly in reactor.

  • PDF

Analysis of Produced By-products Due to Oil/Paper Degradation on Power Transformers (전력용 변압기의 열화에 의해 생성된 부산물의 분석)

  • Kim, Jae-Hoon;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1561-1565
    • /
    • 2007
  • According to thermal degradation on power transformers, it is known that electrical, mechanical and chemical characteristics for power transformer's oil-paper are changed. In the chemical property, especially, when the kraft paper is aged, the cellulose polymer chains break down into shorter lengths. It causes decrease in both tensile strength and degree of polymerization of paper insulation. Also the paper breakdown is accompanied by an increase in the content of various furanic compounds within the dielectric liquid. It is known that furanic components in transformer oil come only from the decomposition of insulating paper rather than from the oil itself. Therefore the analysis of furanic degradation products provides a complementary technique to dissolved gas analysis for monitoring transformers when we evaluate the aging of insulating paper by the total concentration of carbon monoxide and carbon dioxide dissolved in oil only. Recently, the analysis of furanic compounds by high performance liquid chromatography(HPLC) using IEC 61198 method for estimating degradation of paper insulation in power transformers has been used more conveniently for assessment of oil-paper. It is know that the main products which is produced by aging are 2-furfuryl alcohol, 2-furaldehyde(furfural), 2-furoic acid, 2-acetylfuran, 5-methyl-2-furaldehyde, and 5-hydroxymethyl-2-furaldehyde. For investigating the accelerated aging process of oil-paper samples we manufactured accelerating aging equipment and we estimated variation of insulations at $140^{\circ}C$ temp. during 500 hours. Typical transformer proportions of copper, silicon steel and iron have been added to oil-paper insulation during the aging process. The oil-paper insulation samples have been measured at intervals of 100 hours. Finally we have analyzed that 2-furoic acid and 2-acetylfuran products of furanic compounds were detected by HPLC, and their concentrations were increased with accelerated aging time.

Effect of Aggregate on Mechanical Properties of Ultra-High Strength Concrete Exposed to High Temperature (고온을 받은 초고강도 콘크리트의 역학적 특성에 관한 골재의 영향)

  • Kim, Young-Sun;Choi, Hyoung-Gil;Ohmiya, Yoshifumi;Kim, Gyu-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.4
    • /
    • pp.431-440
    • /
    • 2011
  • Concrete structures exposed to fire produce changes in their internal structure, resulting in their service life reduction due to the deterioration of its strength and performance capacity. The deterioration level are dependent on the temperature, exposure time, concrete mix proportions, aggregate property, and material properties. This study was performed to evaluate the thermal behavior of ultra-high strength concrete for the parameters of water to cement ratio (compressive strength), fine to total aggregate ratio, and maximum coarse aggregate size. At room temperature and $500^{\circ}C$, tests of ultrasonic pulse velocity, resonance frequency, static modulus of elasticity, and compressive strength are performed using ${\varnothing}100{\times}200\;mm$ cylindrical concrete specimens. The results showed that the residual mechanical properties of ultra-high strength concrete heated to $500^{\circ}C$ is influenced by variation of a water to binder ratio, fine to total aggregate ratio, and maximum coarse aggregate size.

A Study on the Magnetic Properties of YIG Ferrites with Zr-Substitution (Zr치환에 따른 YIG계 페라이트의 자기적 특성 연구)

  • 양승진;윤종남;김정식
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.5
    • /
    • pp.428-433
    • /
    • 2003
  • In this study, we investigated the variation of microstructural and electromagnetic properties of YIG ferrites for Isolator/Circulator application with the sintering temperature and Zr addition. The composition of the ferrites was Y$_{2.1}$Ca$_{0.9}$Fe$_{4.4-x}$V$_{0.5}$In$_{0.05}$Al$_{0.05}$Zr$_{x}$O$_{12}$ with x=0, 0.05, 0.1 and 0.2. The YIG ferrites were prepared by the conventional ceramic sintering process. The Zr-substituted YIG ferrite, Y$_{2.1}$ Ca$_{0.9}$Fe$_{4.4-x}$V$_{0.5}$In$_{0.05}$Al$_{0.05}$ Zr$_{x}$O$_{12}$ showed the highest saturation magnetization (1097 gauss) at x=0.1. The microwave properties were shown as isolation of 18.60 dB and insertion loss of 0.45 dB at x=0.2. Additionally, Zr-substitution was effective in decreasing ferromagnetic resonance linewidth with Zr content.

Correlation Analysis between DCPT Value and SPT Value (동적콘관입시험값과 표준관입시험값의 상관성 분석)

  • Lee, Bongjik;Lee, Jongkyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.8
    • /
    • pp.23-30
    • /
    • 2014
  • In-situ penetration tests have been widely used in geotechnical engineering for site investigation in support of analysis and design. Standard Penetration Test (SPT) and Dynamic Cone Penetration Test (DCPT) are typical dynamic sounding. DCPT was originally developed as an alternative for evaluating the properties of subgrade soils. The main advantages of DCPT are that it is fast, inexpensive, and it is particularly useful in delineating areas of weak soils overlying stronger strata and in quickly assessing the variability of the soil conditions. But lack of standardization is main reason that this test method has not been advanced more in recent years. In this study, it is clarified the correlation with the SPT blow count, N from DCPT data using big DCP eqipment. Regression analysis and correlationship analysis were conducted with the data from relationship between SPT and DCPT. The analysis results showed that the convert fact are in the range of 1.12~1.31 with variation with soil property.

Morphological research on radio loud AGN 4C39.25 using KaVA observation

  • Yoo, Hyemin;Sohn, Bong Won;Yi, Sukyong K.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.36.3-37
    • /
    • 2015
  • 4C39.25 (0923+392) is a distant radio loud AGN placed at redshift 0.695. The motivation of our work is peculiar properties 4C39.25. Firstly, it has a conspicuous distinction of jet direction between kilo-parsec scale observation made by VLA (Kollgaard et al. 1990) and the parsec scale observation by VLBA (Kellermann et al. 1998). This might indicate episodic-jet activity which recently turned on. This object currently shows two stationary compact parsec-scale components which are bright jet component on east and less luminous core on west. Also, it is known that there have been superluminal jet components which are flowing from the core toward east, and then merging with the bright jet component (Marscher et al. 1991, Alberdi et al. 2000, Lister et al. 2013). Although 4C39.25 seems to be a blazar-like source having broad emission lines (SDSS) and superluminal motion, its property that jet component is brighter than the core is different from ordinary blazars. Furthermore, it has young radio galaxy-like properties such as non-variation in total flux (Alberdi et al. 1997, 2000, MOJAVE database) and high frequency peak at spectral energy distribution (Orienti et al 2007). Such complex properties led us to make recent observations to reveal precise properties and new changes of the source. We used Korean VLBI Network (KVN) and VLBI Exploration of Radio Astronomy (VERA) Array (KaVA) which provide high-frequency (23GHz and 43GHz) and high spatial resolution (1.2mas and 0.6mas). Therefore, this system is suitable for morphological and physical research on parsec scale structure. We present results for several epochs observed during 2013 to 2014, mainly focusing on morphological changes of 4C39.25 using KaVA images.

  • PDF

A Comparative Study of Density Compensation in Gamma-Gamma Log in PVC Casings between above and below Ground Water Tables (지하수면 상.하부 환경에서의 PVC 케이싱 이격보정 비교 연구)

  • Kim, Yeong-Hwa;Hwang, Byong-Chol;Park, Sung-Geun;Kim, Jong-Man
    • The Journal of Engineering Geology
    • /
    • v.19 no.2
    • /
    • pp.217-225
    • /
    • 2009
  • A series of model borehole experiments and analyses for density compensation were performed to achieve the effective density correction of gamma-gamma log obtained from PVC cased boreholes. A follow-up survey was made for clarifying the variation property of detector responses depending on casing types, the presence of borehole fluid, and the degree of separation between probe and borehole wall. A special emphasis was placed on the comparison of gamma responses obtained from above and below ground water tables. Finally, we could quantify the detector responses as a function of separation between the probe and borehole wall, construct standoff compensation charts, and the limitations of the compensation have been discussed for the environments of both above and below ground water tables.