• 제목/요약/키워드: Prompt gamma ray

검색결과 47건 처리시간 0.031초

Simulation of the Determination of NaCl Concentration in Concrete samples by the Neutron induced Prompt Gamma-ray Method

  • Kim, Hyeon-Soo
    • 한국환경과학회지
    • /
    • 제13권2호
    • /
    • pp.175-180
    • /
    • 2004
  • A prompt gamma-ray neutron activation (PGNA) system was simulated by the Monte Carlo N-Particle transport code (MCNP-4A) to estimate the level at which the scattered photon fluence rate, the absolute efficiency of the HPGe-detector, the volume of the concrete sample and the $^{35}$ /Cl(n, ${\gamma}$) reaction rate in this sample contribute to the count rate in the NaCl concentration measurement. The n- ${\gamma}$ fluence rates at the ST-2 beam tube exit of the HANARO reactor were used as input data, and the GAMMA-X type HPGe detector was modeled to tally 1.1649 MeV ${\gamma}$ -rays emitted from the $^{35}$ Cl(n, ${\gamma}$) reaction in the concrete sample. For three cylindrical concrete samples of 13.8, 46.8 and 157.1 ㎤ volumes, respectively, the relations between the NaCl weight fractions of 0.1, 1, 2 and 5 % in each of the concrete samples and the 1.1 649 MeV pulses created in the HPGe detector model were studied. As a result, it was found that the count rate at the same NaCl concentration nearly depends on the volume of the samples in a simulated condition of the same NaCl concentration samples, and that the linearities of the NaCl concentration calibration curves were reasonable in the narrow range of the NaCl weight fraction.

Development of hand-held coded-aperture gamma ray imaging system based on GAGG(Ce) scintillator coupled with SiPM array

  • Jeong, Manhee;Hammig, Mark
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2572-2580
    • /
    • 2020
  • Emerging gamma ray detection applications that utilize neutron-based interrogation result in the prompt emission of high-energy (>2 MeV) gamma-rays. Rapid imaging is enabled by scintillators that possess high density, high atomic number, and excellent energy resolution. In this paper, we evaluate the bright (50,000 photons/MeV) oxide scintillator, cerium-doped Gd2Al2Ga3O12 (GAGG(Ce)). A silicon photomultiplier (SiPM) array is coupled to a GAGG(Ce) scintillator array (12 × 12 pixels) and integrated into a coded-aperture based gamma-ray imaging system. A resistor-based symmetric charge division circuit was used reduce the multiplicity of the analog outputs from 144 to 4. The developed system exhibits 9.1%, 8.3%, and 8.0% FWHM energy resolutions at 511 keV, 662 keV, and 1173.2 keV, respectively. In addition, a pixel-identification resolution of 602 ㎛ FWHM was obtained from the GAGG(Ce) scintillator array.

중성자 핵반응을 이용한 원소 검출기술 - 즉발감마선 중성자 방사화분석법을 이용한 검출기술 - (Elemental Analysis by Neutron Induced Nuclear Reaction - Prompt Gamma Neutron Activation Analysis for Chemical Measurement -)

  • 송병철;박용준;지광용
    • 분석과학
    • /
    • 제16권5호
    • /
    • pp.1041-1051
    • /
    • 2003
  • 즉발감마선 중성자방사화법 (PGAA)은 시료내 미량 및 주원소를 빠르게 비파괴적으로 분석하는 방법으로 주로 광물, 금속, 석탄, 시멘트, 석유, 코팅, 제지 등 다양한 산업체에서 실시간 분석법으로 매우 유용하다. 이 방법은 제약과 관련된 산업체 또는 연구업무에도 활용되며, 마약 또는 폭발물과 같은 위험물질의 탐지에도 이용되고 있다. 본 총설은 즉발감마선 중성자 방사화법의 현재의 기술현황과 앞으로 연구추진 경향에 대하여 서술하였다. PGAA 시스템은 중성자 선원, 증성자 핵반응으로부터 발생하는 즉발감마선을 측정하기위한 다중채널분석기와 A/D 변환기 등의 전자모듈과 고분해능 HPGe 검출기로 구성된다. 속중성자의 콤프턴 산란에 의한 높은 바탕값은 감마-감마 동시계수장치의 도입으로 개선될 수 있다. 현재 $^{252}Cf$를 사용한 즉발감마선 중성자 방사화 장치는 수용액중에 존재하는 원소들의 실시간분석을 위해 한국원자력연구소에서 개발중에 있다. 이 장치는 다양한 마약 및 폭발물 또는 화학무기의 탐지에도 응용될 수 있다.

Analytic simulator and image generator of multiple-scattering Compton camera for prompt gamma ray imaging

  • Kim, Soo Mee
    • Biomedical Engineering Letters
    • /
    • 제8권4호
    • /
    • pp.383-392
    • /
    • 2018
  • For prompt gamma ray imaging for biomedical applications and environmental radiation monitoring, we propose herein a multiple-scattering Compton camera (MSCC). MSCC consists of three or more semiconductor layers with good energy resolution, and has potential for simultaneous detection and differentiation of multiple radio-isotopes based on the measured energies, as well as three-dimensional (3D) imaging of the radio-isotope distribution. In this study, we developed an analytic simulator and a 3D image generator for a MSCC, including the physical models of the radiation source emission and detection processes that can be utilized for geometry and performance prediction prior to the construction of a real system. The analytic simulator for a MSCC records coincidence detections of successive interactions in multiple detector layers. In the successive interaction processes, the emission direction of the incident gamma ray, the scattering angle, and the changed traveling path after the Compton scattering interaction in each detector, were determined by a conical surface uniform random number generator (RNG), and by a Klein-Nishina RNG. The 3D image generator has two functions: the recovery of the initial source energy spectrum and the 3D spatial distribution of the source. We evaluated the analytic simulator and image generator with two different energetic point radiation sources (Cs-137 and Co-60) and with an MSCC comprising three detector layers. The recovered initial energies of the incident radiations were well differentiated from the generated MSCC events. Correspondingly, we could obtain a multi-tracer image that combined the two differentiated images. The developed analytic simulator in this study emulated the randomness of the detection process of a multiple-scattering Compton camera, including the inherent degradation factors of the detectors, such as the limited spatial and energy resolutions. The Doppler-broadening effect owing to the momentum distribution of electrons in Compton scattering was not considered in the detection process because most interested isotopes for biomedical and environmental applications have high energies that are less sensitive to Doppler broadening. The analytic simulator and image generator for MSCC can be utilized to determine the optimal geometrical parameters, such as the distances between detectors and detector size, thus affecting the imaging performance of the Compton camera prior to the development of a real system.

Radiation mechanism of gamma-ray burst prompt emission

  • 엄정휘
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.49.3-50
    • /
    • 2015
  • Synchrotron radiation of relativistic electrons is an important radiation mechanism in many astrophysical sources. In the sources where the synchrotron cooling timescale is shorter than the dynamical timescale, electrons are cooled down below the minimum injection energy. It has been believed that such fast-cooling electrons have a power-law distribution in energy with an index -2, and their synchrotron radiation has a photon spectral index -1.5. On the other hand, in a transient expanding astrophysical source, such as a gamma-ray burst (GRB), the magnetic field strength in the emission region continuously decreases with radius. Here we study such a system, and find that in a certain parameter regime, the fast-cooling electrons can have a harder energy spectrum. We apply this new physical regime to GRBs, and suggest that the GRB prompt emission spectra whose low-energy photon spectral index has a typical value -1 could be due to synchrotron radiation in this moderately fast-cooling regime.

  • PDF

즉발감마선 계측시스템의 반사체를 이용한 열중성자 효율증대 연구 (Study on Thermal Neutron Efficiency for Neutron Induced Prompt Gamma-ray Spectrometer Using Various Reflectors)

  • 박용준;송병철;지광용
    • 분석과학
    • /
    • 제16권5호
    • /
    • pp.426-429
    • /
    • 2003
  • Neutron induced prompt gamma-ray spectroscopy (NIPS) system equipped with a $^{252}Cf$ neutron source and a n-type coaxial HPGe detector was installed for the quantitative analysis of aqueous samples in KAERI, Korea. Since the thermal neutron flux for the $^{252}Cf$ neutron source is relatively low compared to that for the reactor, the use of a thermal neutron reflector in the NIPS system may lead to improved results. The enhancement by using various reflectors was carried out by comparing the Cl peak with or without a cadmium plate between sample and the $^{252}Cf$ source. The use of pyrolitic graphite as a reflector provided a good result.

Beam Characteristics of Polychromatic Diffracted Neutrons Used for Prompt Gamma Activation Analysis

  • S. H. Byun;G. M. Sun;Park, H. D.
    • Nuclear Engineering and Technology
    • /
    • 제34권1호
    • /
    • pp.30-41
    • /
    • 2002
  • The neutron beam is fully characterized for the prompt gamma activation analysis facility at Hanaro in the Korea Atomic Energy Research Institute(KAERI). The facility uses thermal neutrons which are diffracted vertically from a horizontal beam port by a set of pyrolytic graphite(PG) crystals positioned at the Bragg angle of 45" Neutron spectra, neutron flux and Cd-ratio are determined for the three extraction modes of diffracted beam by means of the theoretical and experimental efforts. To obtain theoretical result, the reflectivity of pyrolytic graphite is calculated in the diffraction model for mosaic crystal and the angular divergence after diffraction by mosaic crystal is estimated from Monte Carlo simulation. The time-of-flight spectrometer and gold activation wire are used for measuring the neutron spectra. Both the calculated and measured spectra have proven that the unique feature of polychromatic beam obtained by PG crystals are useful for PGAA. The thermal neutron flux of 7.9$\times$107 n/cm$^2$s and the Cd-ratio of 266 for gold have been achieved at the sample position while the reactor operates at 24 MW The uniformity of beam flux is 12% in the central 1$\times$1 cm$^2$ area. Finally, the beam is briefly characterized by the effective velocity and temperature which are determined by measuring the prompt Y-ray spectra for thin and thick boron samples.ples.

즉발감마선을 이용한 양성자 빔 위치 측정에 관한 연구 (Determination of Proton Beam Position Based on Prompt Gamma Ray Detection)

  • 서규석;김종원;김찬형
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.69-71
    • /
    • 2004
  • 양성자 치료는 양성자 빔의 선량분포 특성인 브래그 피크를 이용한 방사선 치료방법으로 기존의 전자 및 광자빔을 이용하는 방사선 치료와 비교하여 정상세포에는 현저히 적은 선량을 주고, 암세포에는 대부분의 선량을 줄 수 있어 최근에 각광받고 있다. 양성자 치료 빔은 치료 부위에서 완전히 멈추고 인체 내 각기 다른 밀도를 가진 장기들에 의해 양성자 빔의 비정이 불확실하기 때문에 체내 양성자 빔의 분포를 확인하고 빔을 조정하면서 치료할 수 있는 적절한 방법이 없다. 양성자 빔의 물질에 대한 흡수선량 분포와 물질과 양성자의 핵반응으로 방출되는 즉발 감마선의 상관관계를 이용한 측정시스템을 몬테칼로 전산코드로 전산모사하고 계산한 결과 체내 양성자 빔의 위치를 실시간으로 측정할 수 있음을 확인하였다.

  • PDF

즉발감마선방사화분석법에 의한 철강시료 중의 붕소 측정 (Determination of trace boron in steels by prompt gamma-ray activation analysis)

  • 김인중;조경행
    • 분석과학
    • /
    • 제22권4호
    • /
    • pp.302-306
    • /
    • 2009
  • 철강 중의 미량 붕소는 소재의 기계적, 물리적 특성에 중요한 영향을 준다. 즉발감마선 방사화 분석법에 의해 저합금강 시료 중의 미량 붕소를 측정하였다. 시료는 한국표준과학연구원에서 제조한 저합금강 표준물질KRISS 101-01-C21~C26을 이용하였으며, 측정방법의 유효성 확인을 위해 NIST SRM 362, 364, 1761, 1762를 정확도관리용 시료로 사용하였다. NIST SRM 362를 제외하고는 측정 농도가 인증값의 불확도 범위내에서 잘 일치하였다. 불확도는 ISO guideline에 따라 평가하였으며, 포함인자 2를 적용하여 확장불확도를 산출하였다. 붕소 농도 mg/kg수준에서 상대확장불확도는 3%에서 7% 사이였다. 그 결과를 용매추출-유도결합플라스마 방출분광분석결과와 비교하여 제시하였다.