• Title/Summary/Keyword: Prompt NO

Search Result 218, Processing Time 0.029 seconds

NOx Formation Characteristics with Oxygen Enrichment in Nonpremixed Counterflow and Coflow Jet Flames (비예혼합 대향류 및 동축 제트화염에서 산소부화에 따른 NOx 생성특성)

  • Yoo, Byung-Hun;Hwang, Chul-Hong;Han, Ji-Woong;Lee, Chang-Eon
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.169-174
    • /
    • 2004
  • The NOx emission characteristics with oxygen enrichment in nonpremixed counterflow and coflow jet flame of $CH_4$ fuel have been investigated numerically. A small amount of nitrogen is included in oxygen-enriched combustion, in order to consider the inevitable $N_2$ contamination by air infiltration. The results show that the initial increase of NO with increasing oxygen enrichment is due to increasing temperature and residence time, while its subsequent decrease above 75% oxygen is due to decreasing the consumption rate of nitrogen. When oxygen addition exceeds 30%, Thermal NO gradually becomes the dominant production pathway and Prompt NO becomes negative pathway for net NO production rate. It is also seen that Thermal NO plays an important role in NO reduction when strain rate increase in oxygen-enriched combustion. Finally, the results of EINOx with oxygen enrichment in coflow jet flame show the similar profile with those of conterflow flame. It is confirmed that, with leakage of 1% nitrogen in the oxidizer stream, the corresponding EINOx is eight times of that emitted from regular $CH_4$/Air flame.

  • PDF

A Study on NOx Formation Pathway of Methane-Air Lean Premixed Combustion by using PSR Model (PSR 모델을 이용한 메탄-공기 희박 예혼합 연소의 NOx 생성 경로 연구)

  • Lee, Bo-Rahm;Kim, Hyun;Park, Jung-Kyu;Lee, Min-Chul;Park, Won-Shik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.5
    • /
    • pp.46-52
    • /
    • 2009
  • In this study the predictions of NOx in methane-air lean premixed combustion in PSR were carried out with GRI 3.0 methane-air combustion mechanism and Zeldovich, nitrous oxide, prompt, and NNH NO formation mechanism by using CHEMKIN code. The results are compared to the JSR experimental data of Rutar for the validation of the model. This study concerns about the importance of the chemical pathways. The chemical pathway most likely to form the NO in methane-air lean-premixed combustion was investigated. The results obtained with the 4 different NO mechanisms for residence time(0.5-1.6ms) and pressure(3, 4.7, 6.5 atm) are compared and discussed.

Effects of Acoustic Excitation on NOx Emission in Partially Premixed LPG/Air Flames (부분적 예혼합 LPG/공기 화염에서 음향자진이 NOx 배출에 미치는 영향)

  • 장준영;박성호;김태권
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.77-84
    • /
    • 2002
  • Measurements of NO and NOx emission of laminar partially premixed LPG/air flames with and without acoustic excitation are reported. The NOx emission at the tailpipe of a combustion chamber is determined by chemiluminescent analyser. The NOx measurements are taken in flames with several different center tube equivalance ratio( ø$\sub$o/), and overall equivalace ratio(ø$\sub$o/) for a fixed fuel flowrate. The NOx emission decrease to reach a minimum value at an optimum ø$\sub$c/ 2. Theø$\sub$c/ 2 flame gives a compromise of thermal NO and prompt NO mechanism. In the case of excitation. the visual shape of the flame is changed from laminar flame to turbulent-like flame. With increasing levels of excitation amplitude, an optimum value of the NO and NOx emission exists. A shorter flame caused by the enhanced upstream mixing due to acoustic excitation results in the reduction of NO and NOx emission in the present flames. The reduction of flame length affects the shorter residence time of center tube mixture, and significantly influences the NOx reduction.

The Controversy Regarding the Optimal Management of Chronic Low Back Pain: Interventional vs. Medical Treatment (만성요통의 적정 치료를 둘러싼 논란: 중재적 치료 대 보존적 치료)

  • Kwon, O-Hyun
    • Annals of Clinical Neurophysiology
    • /
    • v.12 no.1
    • /
    • pp.1-2
    • /
    • 2010
  • Chronic non-specific low back pain (CLBP) is one of the major health problems casting substantial amount of economic expenses and negative impact on quality of life onto an individual as well as society. On contrary to public familiarity, the ways of management of CLBP are diverse and there is yet no general consensus about which approach is better than others or to whom the specific management should be applied. Some hold the negative point of view on the efficacy of the invasive maneuver such as epidural injection because there is no controlled clinical trial (RCT) yielding better long term outcome of those invasive managements over conservative ones. But the experts of interventional or surgical treatment stress the methodological difficulty in performing RCT and assert that those invasive treatments can bring the prompt and complete resolution of low back pain and restoration of function in appropriately selected cases. These seemingly opposite views on the invasive management on CLBP are rather complimentary each other than to be contradictory.

Design of Improved Detection Instrumentation for the Annulus Gas System for Wolsong 2

  • Kim, Seog-Nam;Koo, Jun-Mo;Chang, Ik-Ho;Jung, Ho-Chang;Han, Sang-Joon
    • Nuclear Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.423-430
    • /
    • 1996
  • The improved and advanced Annulus Gas System(AGS) has been developed for Wolsong 2 to satisfy the requirements of the regulatory body. The Atomic Energy Control Board(AECB) required a shorter detection time following a small leak from a pressure tube and/or calandria tube. This paper describes licensing requirements, functional requirements and detail design description for the AGS. The Wolsong unit No. 1 AGS was designed to operate as a stagnant system normally requiring only pressure regulation and having provisions for purging. no improved AGS involves the adoption of gas recirculation in AGS, duplication of dew point indicators with additional instrumentation and sampling provisions to prompt operator action. The improved system operates in the recirculation mode with continuous dew point measurement for leak detection. An AGS with improved detection instrumentation is provided.

  • PDF

Linearity Estimation of PET/CT Scanner in List Mode Acquisition (List Mode에서 PET/CT Scanner의 직선성 평가)

  • Choi, Hyun-Jun;Kim, Byung-Jin;Ito, Mikiko;Lee, Hong-Jae;Kim, Jin-Ui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.86-90
    • /
    • 2012
  • Purpose: Quantification of myocardial blood flow (MBF) using dynamic PET imaging has the potential to assess coronary artery disease. Rb-82 plays a key role in the clinical assessment of myocardial perfusion using PET. However, MBF could be overestimated due to the underestimation of left ventricular input function in the beginning of the acquisition when the scanner has non-linearity between count rate and activity concentration due to the scanner dead-time. Therefore, in this study, we evaluated the count rate linearity as a function of the activity concentration in PET data acquired in list mode. Materials & methods: A cylindrical phantom (diameter, 12 cm length, 10.5 cm) filled with 296 MBq F-18 solution and 800 mL of water was used to estimate the linearity of the Biograph 40 True Point PET/CT scanner. PET data was acquired with 10 min per frame of 1 bed duration in list mode for different activity concentration levels in 7 half-lives. The images were reconstructed by OSEM and FBP algorithms. Prompt, net true and random counts of PET data according to the activity concentration were measured. Total and background counts were measured by drawing ROI on the phantom images and linearity was measured using background correction. Results: The prompt count rates in list mode were linearly increased proportionally to the activity concentration. At a low activity concentration (<30 kBq/mL), the prompt net true and random count rates were increased with the activity concentration. At a high activity concentration (>30 kBq/mL), the increasing rate of the prompt net true rates was slightly decreased while the increasing rate of random counts was increased. There was no difference in the image intensity linearity between OSEM and FBP algorithms. Conclusion: The Biograph 40 True Point PET/CT scanner showed good linearity of count rate even at a high activity concentration (~370 kBq/mL).The result indicates that the scanner is useful for the quantitative analysis of data in heart dynamic studies using Rb-82, N-13, O-15 and F-18.

  • PDF

An Investigation of the Heat Loss Model for Predicting NO Concentration in the Downstream Region of Laminar CH4/Air Premixed Flames (층류 CH4/Air 예혼합화염의 하류영역에서 NO 농도 예측을 위한 열손실 모델의 검토)

  • Hwang, Cheol-Hong;Lee, Chang-Eon;Kum, Sung-Min;Lee, Kee-Man;Shin, Myung-Chul;Kim, Se-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.7
    • /
    • pp.486-494
    • /
    • 2009
  • One-dimensional modeling of $CH_4$/air premixed flame was conducted to validate the heat loss model and investigate NOx formation characteristics in the postflame region. The predicted temperature and NO concentration were compared to experimental data and previous heat loss model results using a constant gradient of temperature (100 K/cm). The following conclusions were drawn. In the heat loss model using steady-state heat transfer equation, the numerical results using the effective heat loss coefficient ($h_{eff}$) of $1.0\;W/m^2K$ were in very good agreement with the experiments in terms of temperature and NO concentration. On the other hand, the calculated values using the constant gradient of temperature (100 K/cm) were lower than that in the experiments. Although the effects of heat loss suppress NO production near the flame region, a significant difference in NO concentration was not found compared to that under adiabatic conditions. In the postflame region, however, there were considerable differences in NO emission index as well as the contribution of NO formation mechanisms. In particular, in the range of ${\phi}\;{\geq}\;0.8$, the prompt NO mechanism plays an important role in the NO reduction under the adiabatic condition. On the other hand, the mechanism contributes to the NO production under the heat loss conditions.

Spontaneous Perforation of Colon in Previously Healthy Infants and Children: Its Clinical Implication

  • Kim, Soo-Hong;Cho, Yong-Hoon;Kim, Hae-Young
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.19 no.3
    • /
    • pp.193-198
    • /
    • 2016
  • Purpose: Spontaneous colon perforations are usually encountered as necrotizing enterocolitis in the neonatal period, but occur rarely in infants and children without pathological conditions. This study was conducted to describe its clinical implication beyond the neonatal period. Methods: Cases of spontaneous colon perforation confirmed after the operation were reviewed retrospectively and the clinicopathological characteristics were analyzed. Clinical data were compared according to the presence of pneumoperitoneum as initial findings. Results: Eleven patients were included in the study period and showed a history of hospitalization before transfer due to management for fever, respiratory or gastrointestinal problems. Six patients showed a sudden onset of abdominal distention and only seven patients showed a pneumoperitoneum as initial radiologic findings, however there were no significant clinicopathological differences. Perforation was found evenly in all segments of the colon, most commonly at the sigmoid colon in four cases. There were no specific pathologic or serologic causes of perforation. Conclusion: When previously healthy infants and children manifest a sustained fever with a sudden onset of abdominal distention during management for fever associated with respiratory or gastrointestinal problems, there is a great likelihood of colon perforation with no pathological condition. Prompt surgical management as timely decision-making is necessary in order to achieve a good progress.

High-pressure Injection Injuries in the Hand (수부의 고압 분사 손상)

  • Kim, Seong-Ki;Roh, Si-Gyun;Lee, Nae-Ho;Yang, Kyung-Moo
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.245-249
    • /
    • 2010
  • Purpose: High-pressure injection injury is caused by accidental injection of the high-pressure injection devices in industry. The initial benign appearance of the wound fools patients into delays in an adequate treatment. And it can result in disastrous outcomes such as necrosis and amputation. To avoid the poor prognosis, the injuries require a prompt surgical intervention. The purpose of this article is to recognize the poor outcome of the highpressure injection injury and to introduce an adequate treatment in need. Methods: We have 4 cases of the high-pressure injection injuries in the hand from April, 2005 to March, 2009. Average age is 39 years (30 - 49 years old), 2 cases are the palm of dominant hand, 1 case is the thumb of dominant hand, and 1 case is the palm of non-dominant hand, respectively. We followed up these patients for 20 months on average. In 3 cases, the immediate, aggressive surgical intervention was carried out, but the other one was delayed in early adequate treatment. The wounds were covered by local advancement flap, anterolateral thigh free flap, conservative treatment with antibiotics and dressing. Results: No pathogens after culture were found nor any findings of fracture in imaging study. Conservative treatment, local advancement flap and anterolateral thigh free flap for the open wound resulted in a desirable aesthetic outcome. In a long-term follow up, functional capability of the patient was also satisfactory. Conclusion: Upon initial evaluation, most high-pressure injection injuries present as innocuous wounds with very few symptoms and result in delaying the proper management. And the majority of high-pressure injection injuries will produce significant morbidity to the hand, amputation. And the initial aggressive surgical debridement was needed to prevent the poor outcome. The key to success in treating high-pressure injection injuries of the hand is the prompt aggressive surgical intervention.

Influence of Sodium Hypochlorite on Bond Strength of Dual-cured Core Build-up Resin Composite (이원중합형 코어 축조용 복합레진의 결합강도에 대한 NaOCI의 영향에 대한 연구)

  • Lee, Jun-Bong;Park, Jong-Duk;Kwon, Su-Mi;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.283-292
    • /
    • 2007
  • Two-step or one-step bonding systems generally inhibit curing process of dual-cured core build-up resin composite for their adhesive acidity. In addition this dual-cured core build-up resin composite can be applied to dentin of pulp chamber and root at the time that complete the endodontic treatment. The purpose of this investigation was to determine the influence of sodium hypochlorite on rnicrotensile bond strength of dual-cured core build-up resin composite. Extracted human molars were horizontally sectioned with 1mm thickness using low speed diamond saw. After the sectioned specimens were divided into 8 groups, adhesive systems (Clearfil SE-Bond, Prime&Bond NT[2-step, 1-step], Adper Prompt L-Pop) were then applied with or without sodium hypochlorite pretreatment. The treated specimen was filled with dual-cured core build-up resin composite (Luxacore, DMG corp., German). Then light cured for 40 seconds and soaked in $37^{\circ}C$ water bath for 24 hours. After the treated specimen was grinded with 1mm width and measured rnicrotensile bond strength by testing machine. Additionally 8 teeth were prepared for SEM evaluation. The results were as follows. : NaOCl treated groups generally had lower rnicrotensile bond strength but did not show any difference statistically except Adper Prompt L-Pop. When the teeth were treated by NaOCl, though the difference of applied adhesive system, it had no statistically significant difference within the NaOCl treated groups except the relation of between ClearFil SE-Bond adhesive system and Adper Prompt L-Pop adhesive system. In the SEM evaluation, NaOCl treated groups presented relatively long resin tags and incomplete hybrid layer formation generally.