• 제목/요약/키워드: Prompt NO

검색결과 218건 처리시간 0.03초

Jones Jig를 이용한 하악 제 1 대구치 원심이동의 치험례 (Distalization of the lower first molar using Jones Jig)

  • 이상민;김종범;한세현
    • 대한소아치과학회지
    • /
    • 제24권3호
    • /
    • pp.543-548
    • /
    • 1997
  • The first permanent molar takes important place in the occlusion. Malposition of the lower first molar is frequently due to mesial migration, which is occurred by early exfoliation of the second deciduous molar or proximal caries of deciduous teeth. Above things happen without any consideration of space maintainer, prompt measures for space regaining have to be started. Especially in the case with early loss of the second deciduous molar, it has been said that there is no suitable appliance for maintaining the space before the eruption of the permanent first molar. In distalizing the upper first molar, headgears have been routinely used, which its result was definitely depended on cooperation of the patients. Nowadays, appliances such as pendulum appliances, K-loop, magnets, which can be used without cooperation of the patients, are introduced. Jones Jig, one of the molar distalizing appliances, was used on the patients who visited department of pediatric dentistry in Seoul National University Dental Hospital complaining of no eruption space for the lower second bicuspid. Either removable splint or lingal arch was used as the anchorage. Jones Jig was favorably used in the lower molar, where vestibule is shallow, and this is a case report on the satisfactory result thereof.

  • PDF

DESIGN OF LSDS FOR ISOTOPIC FISSILE ASSAY IN SPENT FUEL

  • Lee, Yongdeok;Park, Chang Je;Kim, Ho-Dong;Song, Kee Chan
    • Nuclear Engineering and Technology
    • /
    • 제45권7호
    • /
    • pp.921-928
    • /
    • 2013
  • A future nuclear energy system is being developed at Korea Atomic Energy Research Institute (KAERI), the system involves a Sodium Fast Reactor (SFR) linked with the pyro-process. The pyro-process produces a source material to fabricate a SFR fuel rod. Therefore, an isotopic fissile content assay is very important for fuel rod safety and SFR economics. A new technology for an analysis of isotopic fissile content has been proposed using a lead slowing down spectrometer (LSDS). The new technology has several features for a fissile analysis from spent fuel: direct isotopic fissile assay, no background interference, and no requirement from burnup history information. Several calculations were done on the designed spectrometer geometry: detection sensitivity, neutron energy spectrum analysis, neutron fission characteristics, self shielding analysis, and neutron production mechanism. The spectrum was well organized even at low neutron energy and the threshold fission chamber was a proper choice to get prompt fast fission neutrons. The characteristic fission signature was obtained in slowing down neutron energy from each fissile isotope. Another application of LSDS is for an optimum design of the spent fuel storage, maximization of the burnup credit and provision of the burnup code correction factor. Additionally, an isotopic fissile content assay will contribute to an increase in transparency and credibility for the utilization of spent fuel nuclear material, as internationally demanded.

The Effect of Ownership Structure of Initial Public Offerings (IPOs) on Dividend Initiation: A Case Study in Malaysia

  • DWAIKAT, Nizar;QUEIRI, Abdelbaset;QUBBAJ, Ihab Sameer
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제8권4호
    • /
    • pp.317-328
    • /
    • 2021
  • This study aims to determine the factors that affect dividends initiation by initial public offering firms in Malaysia. The ownership structure is examined from a corporate governance theoretical perspective in order to evaluate the impacts of managerial, institutional, and family ownership on the dividend's initiation decision of IPO firms. This study employs a quantitative pooled cross-section of 372 Malaysian IPO companies active during the period of 2002-2013. The number of firms that went public each year varies, thus the pooled cross-section data takes place in this case rather than the panel data. The logistic model was employed to test the proposed hypotheses. The results revealed that the presence of institutional investors in the ownership structure make it more likely for IPO firms to initiate dividends. On the contrary, the presence of a family ownership structure in IPO companies as the controlling shareholder makes these companies less probable to initiate dividends. Managerial ownership was found to have no effect on the decision of initiating dividends by IPO firms. The findings of this study suggest that the existence of institutional and family ownerships are agency cost mitigators, as these ownership types could prompt IPOs firms to initiate dividends to overcome the agency conflicts.

Posttraumatic bilateral thigh Morel-Lavallée lesions without an underlying bone fracture in the United Kingdom: a case report

  • Sarah Razaq;James Geffner;Asma Khan;Harry Mee;Cynthia Udensi;Fahim Anwar
    • Journal of Trauma and Injury
    • /
    • 제36권3호
    • /
    • pp.269-275
    • /
    • 2023
  • A Morel-Lavallée lesion results from a degloving injury between the muscle fascia and the subcutaneous layer. It is most commonly found in the trochanteric area but can occur at other sites. The treatment of the condition varies according to the medical circumstances, as well as the size and chronicity of the condition. A case of large (18×6 and 10×5 cm) bilateral posttraumatic Morel-Lavallée lesions with no underlying bone fracture is presented; the case occurred in a 49-year-old male patient 4 weeks posttrauma. Ultrasound scans showed bilateral large collections of anechoic fluid, which were aspirated under ultrasound guidance and further managed by compression bandages. There were no further complications. The objective of this case report is to present this unique and educational case, as well as to provide an overview of the pathophysiology, diagnosis, and management of Morel-Lavallée lesions. We conclude by discussing the importance of having a high index of suspicion to ensure early detection and prompt treatment of such lesions to avoid complications.

Core Network 유지 보수를 위한 NO.7 Protocol 감시 방안 (Core network maintenance by NO.7 protocol analyzing)

  • 유준모;김윤성
    • 대한전자공학회논문지TC
    • /
    • 제42권1호`
    • /
    • pp.49-60
    • /
    • 2005
  • 유무선 기간 망에서 사용되어 지는 Core Network System간 연동 부분의 Back Bone이 NO.7 Protocol이다. 그래서 유선망에서 기본적인 중계 ISUP이나, 지능망 INAP 처리, 그리고 이동망에서 각 Network Element System간 연동되는 MAP 연동 방식이 NO.7 방식을 사용하고 있다. 따라서 이 NO.7을 이용하는 Core Network에서 운영 중에 장애가 발생하거나, 기존에 인지되지 않고 지나온 문제점들을 최단시간에 감지하여 도출할 수 있는 시스템이 필요로 되었다. 본 논문에서는 Core Network 에서 사용되는 NO.7 Signaling 방식에 대해 더욱 신뢰성을 확보하고, 장애 발생 여부 등을 분석할 수 있도록 하기 위하여 NO.7 Signaling Message들을 추출하여 Core Network 시스템의 기능 및 성능을 분석하고 Report를 작성할 수 있는 NO.7 Protocol 분석 측정 시스템을 고안하였다. 이 시스템은 NO.7 Signaling을 담당하는 Core Network 시스템의 NO.7 HW Module 에 연결하여 Monitoring만 수행하고, 어떤 시나리오에 대한 Emulator 기능이나 Simulation 기능은 제공하지 않는다. 이 시스템은 현재 NO.7 MTP, ISUP, INAP, 그리고 MAP 에 대해 측정 및 분석기능을 수행하도록 하였고, 여러 유무선 기간 망 사업자에 제공하여 SW 및 HW 적인 면 그리고 운영적인면 등에서 여러 가지 문제들을 확인하여 교정할 수 있었다. 향후에는 이외에 BSC-MSC 연동되어 지는 A-Interface 등과 같은 기능도 제공함으로써 NO.7 Protocol 전반적인 분석과 동시에 Core Network 시스템에 효율적인 운영을 도모할 수 있다.

Resection and Observation for Brain Metastasis without Prompt Postoperative Radiation Therapy

  • Song, Tae-Wook;Kim, In-Young;Jung, Shin;Jung, Tae-Young;Moon, Kyung-Sub;Jang, Woo-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권6호
    • /
    • pp.667-675
    • /
    • 2017
  • Objective : Total resection without consecutive postoperative whole brain radiation therapy is indicated for patients with a single or two sites of brain metastasis, with close follow-up by serial magnetic resonance imaging (MRI). In this study, we explored the effectiveness, usefulness, and safety of this follow-up regimen. Methods : From January 2006 to December 2015, a total of 109 patients (76 males, 33 females) underwent tumor resection as the first treatment for brain metastases (97 patients with single metastases, 12 with two metastases). The mean age was 59.8 years (range 27-80). The location of the 121 tumors in the 109 patients was supratentorial (n=98) and in the cerebellum (n=23). The origin of the primary cancers was lung (n=45), breast (n=17), gastrointestinal tract (n=18), hepatobiliary system (n=8), kidney (n=7), others (n=11), and unknown origin (n=3). The 121 tumors were totally resected. Follow-up involved regular clinical and MRI assessments. Recurrence-free survival (RFS) and overall survival (OS) after tumor resection were analyzed by Kaplan-Meier methods based on clinical prognostic factors. Results : During the follow-up, MRI scans were done for 85 patients (78%) with 97 tumors. Fifty-six of the 97 tumors showed no recurrence without adjuvant local treatment, representing a numerical tumor recurrence-free rate of 57.7%. Mean and median RFS was 13.6 and 5.3 months, respectively. Kaplan-Meier analysis revealed the cerebellar location of the tumor as the only statistically significant prognostic factor related to RFS (p=0.020). Mean and median OS was 15.2 and 8.1 months, respectively. There were no significant prognostic factors related to OS. The survival rate at one year was 8.2% (9 of 109). Conclusion : With close and regular clinical and image follow-up, initial postoperative observation without prompt postoperative radiation therapy can be applied in patients of brain metastasi(e)s when both the tumor(s) are completely resected.

광조사 시간이 접착제의 표면 미중합층의 두께와 전단접착강도에 미치는 영향에 관한 연구 (Influence of the curing time for the adhesive on the oxygen-inhibited layer thickness and the shear bond strength to dentin)

  • 최용훈;배지현;손호현;이인복;백승호;엄정문;김오영;김창근;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.177-184
    • /
    • 2004
  • 본 연구는 광중합형 상아질 접착제에서 광조사 시간의 증가가 접착제 표면의 미중합층에 대한 영향과 그에 따른 전단접착강도에 대해 연구하고자 120개의 치아를 아크릴 몰드에 식립한 후 상아질이 노출되도록 연마하였다. 3종류의 접착제 〔All Bond2 (AB2), One-Step (OS) and Adper Prompt (AP)〕를 40개 치아에 제조사의 지시대로 도포한 후 각각 다른 광조사 시간 (10, 20, 30 and 60sec)동안 광조사 하고 복합레진을 접착한 24시간 후 전단접 착강도를 측정하였다. 미중합층의 두께와 중합률은 슬라이드 글라스와 FT-NIR을 이용하여 FT-NIR spectrum에서의 peak height를 비교 측정하여 다음과 같은 결론을 얻었다. 1. 전단접착강도에서 AB2는 20초 이후 감소하고, AP는 30초까지 증가하였으며,OS는 차이를 보이지 않았다. 2. 미중합층 두께는 3가지 접착제 모두 유의성 있는 차이를 보이지 않았다. 3. 중합률에서 OS는 10초와 나머지군 사이에 유의성 있는 차이를, AP는 60초에서 유의성 있게 증가되고, AB2의 경우 차이를 나타내지 않았다.

올인원 접착제의 미세누출에 관한 정량적 분석 (A QUANTITATIVE ANALYSIS ABOUT MICROLEAKAGE OF ALL-IN-ONE ADHESIVES)

  • 강용희;신수일;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제29권1호
    • /
    • pp.66-72
    • /
    • 2004
  • All-in-one adhesives were recently developed for reducing the technique sensitivity and chair time, but lots of concerns were made on bondability, longevity, and microleakage. The object of this study was to evaluate microleakage and marginal quality of all-in-one adhesives using electrochemical method and SEM analysis quantitatively. After making Class V cavities, they were bulk filled with Heliomolar(#A1 after surface treatment with three adhesives: Adper Prompt (Group A), One up bond F (Group O), Xeno III (Group X) Electrical conductivity (microamphere, ${\mu}A$) was checked two times: before and after cavity filling. Percentage of leaky margin was estimated from SEM image (${\times}1,000$). The data were statistically analysed: ANOVA and Paired T test for electrical conductivity, Kruskal-Wallis and Mann-Whitney test for marginal quality, Spearman s rho test for checking of relationships between 2 methods. The result were as follows: 1. There was no difference in microleakage between adhesive systems and every specimen showed some of microleakage after filling. 2. Microleakage was reduced about 70% with composite resin filling. 3. Marginal quality was the best in group A. decreasing among groups in the following order: group O, followed by group X. There were significant differences between group A and group X (p=0.015), and between group 0 and group X (p=0.019). 4. There was no relationship between the microleakage measured by electrochemical method and marginal quality measured by SEM analysis. Within the results of this study, there was no difference in microleakage among groups by electrical conductivity. However, significant difference in marginal quality was seen among groups. It was believed that these dissimilar results might be induced because of their own characteristics. Analysis of microleakage needs various methods for accuracy.

Orbital floor fracture repair with implants: a retrospective study

  • Lee, Yong Jig
    • 대한두개안면성형외과학회지
    • /
    • 제22권4호
    • /
    • pp.177-182
    • /
    • 2021
  • Background: Although prompt surgery after an orbital fracture is preferable, the actual timing of surgery in real-world settings varies. Therefore, this study investigated the outcomes of implant surgery for inferior orbital wall fractures by comparing three groups according to the time interval between the injury and surgery. Methods: A retrospective review was conducted of patients' medical charts and initial computed tomography images from 2009 to 2020. The time to treatment was chosen by patients or their guardians based on the patients' comorbidities and the physician's explanation. The patients were divided into three groups according to the time of surgery (group 1: 3-7 days, group 2: 8-14 days, group 3: 15 or more days). Data were collected on age, the time interval until surgery, the dimensions of the defect, the operation time, the follow-up period, and the postoperative paresthesia score (ranging from 0 to 10). The outcomes were evaluated using a 4-point scale: 4=good (no complications), 3=fair (no subjective symptoms), 2=poor (remaining paresthesia), and 1=very poor (strabismus and/or enophthalmos). Results: The study included 85 patients with unilateral fractures who underwent surgery from 3 to 93 days after injury. The overall score distribution of the surgical outcomes was as follows: good=63, fair=7, poor=6, and very poor=9. The three groups showed no significant differences in the transverse dimension of the injury (p=0.110) or the anteroposterior dimension (p=0.144). In groups 1, 2, and 3, the postoperative outcome scores were 3.84±0.37, 3.63±0.87, and 2.93±1.33 (p=0.083), and the percentage of patients with good outcomes was 84%, 81.25%, and 57.14%, respectively. Conclusion: Performing surgery using an artificial implant within 2 weeks of the injury showed better outcomes and fewer postoperative complications than when treatment was delayed.

Numerical Modeling of Combustion Processes and Pollutant Formations in Direct-Injection Diesel Engines

  • Kim, Yong-Mo;Lee, Joon-Kyu;Ahn, Jae-Hyun;Kim, Seong-Ku
    • Journal of Mechanical Science and Technology
    • /
    • 제16권7호
    • /
    • pp.1009-1018
    • /
    • 2002
  • The Representative Interactive Flamelet (RIF) concept has been applied to numerically simulate the combustion processes and pollutant formation in the direct injection diesel engine. Due to the ability for interactively describing the transient behaviors of local flame structures with CFD solver, the RIF concept has the capabilities to predict the auto-ignition and subsequent flame propagation in the diesel engine combustion chamber as well as to effectively account for the detailed mechanisms of soot formation, NOx formation including thermal NO path, prompt and nitrous 70x formation, and reburning process. Special emphasis is given to the turbulent combustion model which properly accounts for vaporization effects on the mixture fraction fluctuations and the pdf model. The results of numerical modeling using the RIF concept are compared with experimental data and with numerical results of the commonly applied procedure which the low-temperature and high-temperature oxidation processes are represented by the Shell ignition model and the eddy dissipation model, respectively. Numerical results indicate that the RIF approach including the vaporization effect on turbulent spray combustion process successfully predicts the ignition delay time and location as well as the pollutant formation.