• 제목/요약/키워드: Progress measurement

검색결과 712건 처리시간 0.022초

소동물용 뇌자도 측정 시스템 개발 (Development of a Magnetoencephalograph System for Small Animals)

  • 김지은;김인선;강찬석;권혁찬;김진목;이용호;김기웅
    • Progress in Superconductivity
    • /
    • 제13권1호
    • /
    • pp.18-23
    • /
    • 2011
  • We developed a four-channel first order gradiometer system to measure magnetoencephalogram for mice. We used double relaxation oscillation SQUID (DROS). The diameter of the pickup coil is 4 mm and the distance between the coils is 5 mm. Coil distance was designed to have good spatial resolution for a small mouse brain. We evaluated the current dipole localization confidence region for a mouse brain, using the spherical conductor model. The white noise of the measurement system was about 30 fT/$Hz^{1/2}$/cm when measured in a magnetically shielded room. We measured magnetic signal from a phantom having the same size of a mouse brain, which was filled with 0.9% saline solution. The results suggest that the developed system has a feasibility to study the functions of brain of small animals.

심자도 측정을 위한 SQUID 센서 기술의 개발 현황 (Review of SQUID Sensors for Measuring Magnetocardiography)

  • 이용호;김진목;유권규;김기웅;권혁찬
    • Progress in Superconductivity
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2011
  • Measurement of magnetic signals generated from electric activity of myocardium provides useful information for the functional diagnosis of heart diseases. Key technical component of the magnetocardiography (MCG) technology is SQUID. To measure MCG signals with high signal-to-noise ratio, sensitive SQUID magnetic field sensors are needed. Present magnetic field sensors based on Nb SQUIDs have field sensitivity good enough to measure most of MCG signals. However, for accurate measurement of fine signal pattern or detection of local atrial fibrillation signals, we may need higher field sensitivity. In addition to field sensitivity, economic aspect of the SQUID system is also important. To simplify the SQUID readout electronics, the output voltage or flux-to-voltage transfer of SQUID should be large enough so that direct measurement of SQUID output can be done using room-temperature preamplifiers. Double relaxation oscillation SQUID (DROS), having about 10 times larger flux-to-voltage transfers than those of DC-SQUIDs, was shown to be a good choice to make the electronics compact. For effective cancellation of external noise inside a thin economic shielded room, first-order axial gradiometer with high balance, simple structure and long-baseline is needed. We developed a technology to make the axial gradiometer compact using direct bonding of superconductive wires between pickup coil and input coil. Conventional insert has mechanical support to hold the gradiometer array, and the dewar neck has equal diameter with the dewar bottom. Boiling of the liquid He can generate mechanical vibrations in the gradiometer array due to mechanical connection structure. Elimination of the mechanical support, and direct mounting of the gradiometer array into the dewar bottom can reduce the dewar neck diameter, resulting in the reduction of liquid He consumption.

계측기기 연구개발 전략에 관한 연구 (A Study on Research and Development Strategies for Measuring Instrument)

  • 최만용
    • 한국생산제조학회지
    • /
    • 제6권1호
    • /
    • pp.109-114
    • /
    • 1997
  • In the past few decades, the measuring instrument industries have made rapid progress with increase on the demand in industries such as precision instrument, chemistry, electronics, industrial measurement and automobile. Thus, development strategy and technical advancement are required for both securing the competitiveness on products in the world market and industrial development. Intensifying competitiveness of measuring instrument is needed in the world market. It can be achieved by development of measuring instrument holding comparative priority. A development strategy should be drawn up in the long-term point of view for coping with the increasing demand of measuring instrument and securing competitiveness in the world market.

  • PDF

TDR을 이용한 토양함수비 측정 (Mesurement of Soil Water Content using Time Domain Reflectometry(TDR))

  • 김경한;윤춘경
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.407-413
    • /
    • 1998
  • Considerable progress has been made in the application of time-domain reflectrometry(TDR) to measurement of soil water content. The TDR provides a means of monitoring the water content of soil over a wide range of values, in the field and in the laboratory The TDR measures the volumetric moisture content of the soil via a bureid sensor(probe). Probes can be buried and monitored remotely and an immediate result can be obtained. In addition to, the results are very reliable.

  • PDF

SCADA 네트워크 보안 이슈 (Security Issues in SCADA Network)

  • 김학만;강동주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.46-47
    • /
    • 2007
  • SCADA (Supervisory Control and Data Acquisition) system has been used fur remote measurement and control on the critical infrastructures as well as modem industrial facilities. As cyber attacks increase on communication networks. SCADA network has been also exposed to cyber security problems. Especially, SCADA systems of energy industry such as electric power, gas and oil are vulnerable to targeted cyber attack and terrorism. Recently, many research efforts to solve the problems have made progress on SCADA network security. In this paper, we introduce recent security issue of SCADA network and propose the application of encryption method to Korea SCADA network.

  • PDF

초고층 RC구조의 기둥축소량 해석 및 현장계측 (Calculation and Measurement of Column Shortening High-Rise RC Structure)

  • 이성원;박현일;김원식;오정근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.133-138
    • /
    • 2003
  • Axial shortenings of wall and columns were measured on level 2 and precise leveling between wall and columns were surveyed on level 5 at the Galleria Palace structure. Measured and surveyed shortening values were compared with the analysis results at the earlier stage on the process of construction for evaluating the predicted values. Though measured values represent relatively low and scattered values at earlier construction stage, probably they show similar slope curves to predicted ones with the progress of time.

  • PDF

크랙에 의한 고온 초전도체 테이프의 임계전류 특성변화 (The variation of critical current by the formation of crack in a high-temperature superconducting tape)

  • 박을주;설승윤
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.73-77
    • /
    • 2002
  • The variation of critical current by the formation of crack in a high temperature super-conducting tape was studied by experimental and numerical analyses. The current-voltage relation of HTS tape is measured by the four-point measurement method. Numerical analyses are used to solve two dimensional heat conduction equation, considering the temperature distribution. By comparing current-voltage relation of experimental and numerical results, the validity of numerical method is verified.

Junction, Circuit and System Developments for a High-$T_c$ Superconductor Sampler

  • Hidaka, M.;Satoh, T.;Tahara, S.
    • Progress in Superconductivity
    • /
    • 제1권2호
    • /
    • pp.81-84
    • /
    • 2000
  • A Josephson sampler circuit using high-Tc superconductor (HTS) ramp-edge junctions has been designed, fabricated, and experimentally tested. It consists of five ramp-edge junctions with a stacked groundplane and is based on single-flux-quantum (SFQ) operations. The sampler was used to measure current waveforms at picosecond and microampere resolutions. We are developing a system based on the sampler for measuring the current waveform in a room-temperature sample. And measuring current flowing through wiring in a semiconductor large-scale integrated circuit is a promising application for the HTS sampler system.

  • PDF

Construction Of The Measurement Model Of User Satisfaction In Internet Shopping Environment -Based On The End-Use Computng Satisfaction Instrument -

  • 김태환
    • 통상정보연구
    • /
    • 제8권1호
    • /
    • pp.3-13
    • /
    • 2006
  • To develop and validate an instrument to measure user satisfaction in Internet shopping environment, the EUCS instrument by Doll and Torkzadeh (1988) was used for this research. The results of the study shows how the main constructs of the model that will eventually interact for the user satisfaction in internet commerce environment. This research will present significant progress towards keeping the End-User Computing Satisfaction instrument relevant and applicable under the Internet shopping environment.

  • PDF

Patient compliance with drug treatment - new perspectives on an old problem

  • Kruse W.
    • 대한예방의학회:학술대회논문집
    • /
    • 대한예방의학회 1994년도 교수 연수회(역학)
    • /
    • pp.332-335
    • /
    • 1994
  • Compared to other variables being considered in therapeutics, patient compliance has long been given minor attention although it affects every aspect of medical care; Limited methodology of compliance measurement, in particular, has hampered major progress in research, and pre-conceptions have been reiterated. However, there is a recent surge in interest derived from new data revealed by reliable methods, i.g. continuous medication (compliance) monitoring. The visualization of dynamics in drug regimen compliance over time offers unique opportunities, both to scientific drug evaluation and therapeutics in medical practice. New perspectives related to the descriptive and explanatory side of the problem are outlined by giving examples from various therapeutic fields.

  • PDF