Finishing and polishing effects of multiblade burs on the surface texture of 5 resin composites: microhardness and roughness testing

  • Ehrmann, Elodie;Medioni, Etienne;Brulat-Bouchard, Nathalie
    • Restorative Dentistry and Endodontics
    • /
    • 제44권1호
    • /
    • pp.1.1-1.12
    • /
    • 2019
  • Objectives: The aim of this in vitro study was to test the effect of 2 finishing-polishing sequences (QB, combining a 12/15-fluted finishing bur and an EVO-Light polisher; QWB, adding a 30-fluted polishing bur after the 12/15-fluted finishing bur used in the QB sequence) on 5 nanotech-based resin composites (Filtek Z500, Ceram X Mono, Ceram X Duo, Tetric Evoceram, and Tetric Evoceram Bulk Fill) by comparing their final surface roughness and hardness values to those of a Mylar strip control group (MS). Materials and Methods: Twelve specimens of each nanocomposite were prepared in Teflon moulds. The surface of each resin composite was finished with QB (5 samples), QWB (5 samples), or MS (2 samples), and then evaluated (60 samples). Roughness was analysed with an optical profilometer, microhardness was tested with a Vickers indenter, and the surfaces were examined by optical and scanning electron microscopy. Data were analysed using the Kruskal-Wallis test (p < 0.05) followed by the Dunn test. Results: For the hardness and roughness of nanocomposite resin, the QWB sequence was significantly more effective than QB (p < 0.05). The Filtek Z500 showed significantly harder surfaces regardless of the finishing-polishing sequence (p < 0.05). Conclusions: QWB yielded the best values of surface roughness and hardness. The hardness and roughness of the 5 nanocomposites presented less significant differences when QWB was used.

Simulated occlusal adjustments and their effects on zirconia and antagonist artificial enamel

  • Alfrisany, Najm Mohsen;Shokati, Babak;Tam, Laura Eva;De Souza, Grace Mendonca
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권3호
    • /
    • pp.162-168
    • /
    • 2019
  • PURPOSE. The aim of this study was to evaluate the effect of occlusal adjustments on the surface roughness of yttria-tetragonal zirconia polycrystal (Y-TZP) and wear of opposing artificial enamel. MATERIALS AND METHODS. Twenty-five Y-TZP slabs from each brand (Lava, 3M and Bruxzir, Glidewell Laboratories) with different surface conditions (Control polished - CPZ; Polished/ground - GRZ; Polished/ground/repolished - RPZ; Glazed - GZ; Porcelain-veneered - PVZ; n=5) were abraded (500,000 cycles, 80 N) against artificial enamel (6 mm diameter steatite). Y-TZP roughness (in ${\mu}m$) before and after chewing simulation (CS) and antagonist steatite volume loss (in $mm^3$) were evaluated using a contact surface profilometer. Y-TZP roughness was analyzed by three-way analysis of variance (ANOVA) and steatite wear by two-way ANOVA and Tukey Honest Difference (HSD) (P=.05). RESULTS. There was no effect of Y-TZP brand on surface roughness (P=.216) and steatite loss (P=.064). A significant interaction effect (P<.001) between surface condition and CS on Y-TZP roughness was observed. GZ specimens showed higher roughness after CS (before CS - $3.7{\pm}1.8{\mu}m$; after CS - $13.54{\pm}3.11{\mu}m$), with partial removal of the glaze layer. Indenters abraded against CPZ ($0.09{\pm}0.03mm^3$) were worn more than those abraded against PVZ ($0.02{\pm}0.01mm^3$) and GZ ($0.02{\pm}0.01mm^3$). Higher wear caused by direct abrasion against zirconia was confirmed by SEM. CONCLUSION. Polishing with an intraoral polishing system did not reduce the roughness of zirconia. Wear of the opposing artificial enamel was affected by the material on the surface rather than the finishing technique applied, indicating that polished zirconia is more deleterious to artificial enamel than are glazed and porcelain-veneered restorations.

Physical and mechanical changes on titanium base of three different types of hybrid abutment after cyclic loading

  • Rimantas Oziunas;Jurgina Sakalauskiene;Laurynas Staisiunas;Gediminas Zekonis;Juozas Zilinskas;Gintaras Januzis
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권1호
    • /
    • pp.33-43
    • /
    • 2023
  • PURPOSE. This study investigated the physical and mechanical changes in the titanium base of three different hybrid abutment materials after cyclic loading by estimating the post-load reverse torque value (RTV), compressive side fulcrum wear pattern of titanium base, and surface roughness. MATERIALS AND METHODS. A total of 24 dental implants were divided into three groups (n = 8 each): Group Z, LD, and P used zirconia, lithium disilicate, and polyetheretherketone, respectively, for hybrid abutment fabrication. RTV was evaluated after cyclic loading with 50 N for 1.2 × 106 chewing cycles. The compressive sides of the titanium bases were analyzed using a scanning electron microscope, and the roughness of the affected areas was measured using an optical profilometer after loading. Datasets were analyzed using Kruskal-Wallis test followed by Mann-Whitney tests with the Bonferroni correction (α = .05). RESULTS. Twenty-three samples passed the test; one LD sample fractured after 770,474 cycles. Post-load RTV varied significantly depending on the hybridabutment material (P = .020). Group P had a significantly higher median of post-load RTVs than group Z (16.5 and 14.3 Ncm, respectively). Groups LD and P showed minor signs of wear, and group Z showed a more pronounced wear pattern. While evaluating compressive side affected area roughness of titanium bases, lower medians were shown in group LD (Ra 0.16 and Rq 0.22 ㎛) and group P (Ra 0.16 and Rq 0.23 ㎛) than in group Z (Ra 0.26 and Rq 0.34 ㎛); significant differences were found only among the unaffected surface and group Z. CONCLUSION. The hybrid abutment material influences the post-load RTV. Group Z had a more pronounced wear pattern on the compressive side of titanium base; however, the surface roughness was not statistically different among the hybridabutment groups.

Hydroxyapatite 피막 처리된 임프란트에 대한 여러가지 기계적 표면처리방법이 임프란트 표면조도 및 성상에 미치는 영향 (EFFECT OF VARIOUS MECHANICAL TREATMENTS OF HYDROXYAPATITE-COATED IMPLANT SURFACES)

  • 양경란;정오철;이재목;서조영
    • Journal of Periodontal and Implant Science
    • /
    • 제24권1호
    • /
    • pp.131-143
    • /
    • 1994
  • 구강내 노출된 임프란트를 건강한 상태로 유지하기 위해서는 임프란트 매식체 표면을 처치하여 주위조직과 잘 적합할 수 있는 표면구조를 만들어 주어야 한다. 실패한 임프란트의 처리방법으로 구연산이나 air-abrasive system과 같은 여러 가지 방법이 소개 되었으나 HA 피막 처치된 임프란트와 같은 거친 표면이 구강내로 노출된 경우에는 구연산이나 air-abrasive system을 이용한 표면 처리방법을 세균독소 제거에는 효과적이나 HA 피막 처리된 매식체의 거친 표면 제거는 어렵기 때문에 계속되는 치태침착을 방지하기에는 효과적이지 못하므로 세균독소를 제거하는 한편 표면성상을 변화시키지 않고 평활한 표면을 만들기 위한 처리방법들을 알아보고자 하였다. IMZ사에서 제작한 HA 피막 처리된 disc에 high speed diamond bur, low speed diamond bur, stone bur, rubber point, jetpolisher를 처치하고 표면평활도를 알아보기 위하여 표면조도측정 및 주사전자현미경으로 표면상태를 관찰하고 표면성분 변화 유무를 알아보기 위하여 EDX를 이용하여 표면성분을 분석한 결과 다음과 같은 결과를 얻었다. 각 시편에 대한 표면조도 측정 결과는 실험 I군 $2.11{\mu}m$, 실험 II군 $4.17{\mu}m$, 실험 III군 $7.28{\mu}m$, 실험 IV군 $8.61{\mu}m$, 실험 V군 $39.44{\mu}m$의 최대높이값을 나타내므로써, I, II, III, IV, V군 순으로 표면이 평활하게 나타났다. 주사전자현미경 관찰에서는 실험 I군은 비교적 평활한 면을 보였고, 실험 II군은 HA 입자가 거의 삭제되었으나 잔존하는 일부의 HA 입자로 인하여 I군보다 약간 거친 표면을 보였다. 실험 III군과 IV군은 삭제되지 않고 잔존하는 HA 입자가 많아 거친 양상을 보였으며 실험 V군인 HA 피막 처리된 면의 경우는 깊은 홈과 돌출된 부분을 가진 매우 불규칙한 표면 구조를 보였다. 시편의 단면 관찰에서는 실험 I군은 균일한 면을 보였으며 실험 III군과 IV군에서는 삭제되지 않고 잔존하는 다량의 HA 입자로 인해 거친 표면을 보였으나 HA 피막의 두께는 상당량 감소되어 나타났다. 또한 실험 II군과 I군과 유사한 양상을 보였다. 실험 V군의 경우는 일정하지는 않지만 약 $40{\mu}m$의 두께를 보였다. EDX에 의한 표면성분 분석 결과, 삭제가 가장 우수한 실험 II군에서는 calcium과 phosphorus가 소량 나타났고, 삭제가 완전하지 않은 실험 III, IV군에서는 calcium peak와 phosphorus peak를 보였다. 모든 군에 나타난 aluminum은 제조과정 중의 혼입으로 사료된다. 모든 실험군에서 titanium, aluminum, calcium, phosphorus 이외의 다른 성분은 나타나지 않았다.

  • PDF

Corrosion Characteristics of Cell-Covered Ternary Ti-Nb-Ta Alloy for Biomaterials

  • Kim, W.G.;Yu, J.W.;Choe, H.C.;Ko, Y.M.;Park, G.H.
    • Corrosion Science and Technology
    • /
    • 제8권2호
    • /
    • pp.62-67
    • /
    • 2009
  • Ti and Ti-alloys have good biocompatibility, appropriate mechanical properties and excellent corrosion resistance. However, the widely used Ti-6Al-4V is found to release toxic ions (Al and V) into the body, leading to undesirable long-term effects. Ti-6Al-4V has much higher elastic modulus (100 GPa) than cortical bone (20 GPa). Therefore, titanium alloys with low elastic modulus have been developed as biomaterials to minimize stress shielding. The electrochemical behavior of surface-modified and MC3T3-E1 cell-cultured Ti-30(Nb,Ta) alloys with low elastic modulus have been investigated using various electrochemical methods. Surfaces of test samples were treated as follows: $0.3{\mu}m$ polished; $25{\mu}m$, $50{\mu}m$ and $125{\mu}m$ sandblasted. Specimen surfaces were cultured with MC3T3-E1 cells for 2 days. Average surface roughness ($R_a$) and morphology of specimens were determined using a surface profilometer, OM, and FE-SEM. Corrosion behavior was investigated using a potentiostat(EG&G PARSTAT 2273), and electrochemical impedance spectroscopy was performed (10 mHz to 100 kHz) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The microstructures of the Ti-30(Ta,Nb) alloys had a needle-like appearance. The $R_a$ of polished Ti-30Ta and Ti-30Nb alloys was lower than that of the sandblasted Ti alloy. Cultured cells displayed round shapes. For polished alloy samples, cells were well-cultured on all surfaces compared to sandblasted alloy samples. In sandblasted and cell-cultured Ti-30(Nb,Ta) alloy, the pitting potential decreased and passive current density increased as $R_a$ increased. Anodic polarization curves of cell-cultured Ti alloys showed unstable behavior in the passive region compared to non-cell-cultured alloys. From impedance tests of sandblasted and cell-cultured alloys, the polarization resistance decreased as $R_a$ increased, whereas, $R_a$ for cell-cultured Ti alloys increased compared to non-cell-cultured Ti alloys.

부식시간이 소의 법랑질 부식깊이와 교정용 레진의 전단결합강도에 미치는 영향 (EFFECTS OF VARIOUS ETCHING TIMES ON DEPTH OF ETCH AND SHEAR BOND STRENGTH OF AN ORTHODONTIC RESIN TO BOVINE ENAMEL)

  • 김정훈;이기수;박영국
    • 대한치과교정학회지
    • /
    • 제23권1호
    • /
    • pp.75-88
    • /
    • 1993
  • Recent reports indicate that shorter etching times than 60 seconds can be adopted without affecting the bond strength and clinical disadvantages. The purpose of this in vitro study was to compare the shear bone strength and to measure depth of etch at different etching time length. One hundred and eight extracted bovine lower central incisors were embedded each in a tooth cup with cold-cure acrylic resin. The facial surfaces of the teeth were ground wet with 600-, 800-, 1000-, and 1200-grit Sic papers, and finally polished with a water slurry of extrafine silicon carbide powder, washed with tap water, and dried with hot air. Nine groups of nine prepared teeth were etched with a commercial($38\%$ phosphoric acid solution) for 0, 5, 10, 15, 20, 30, 60, 90, and 120 seconds, respectively, rinsed with tap water, and dried with hot air. One conditioned teeth from every group was selected randomly for the scanning electron microscopic examination, and the remaining eight teeth of the groups were used for measuring the push shear bond strength after bonding brackets and immensing them in the $36.5^{\circ}C$ water for 24 hours. Another nine groups of three teeth were used for measuring the depth of etch and surface roughness with a surface profilometer. after pieces of adhesive tape of 3mm inner diameter positioned on the ground enamel surfaces, and etched with the above mentioned. The data obtained form the above expeiments were analysed statistically with one way ANOVA and Dunkan's multiple range test with the $95\%$ confidence level. The results and conclusion of the study were as follows; 1. The results of shear bond strength for the given experimental etching times were not statistically different, but showed the tendency of decreasing shear bone strength after over 60 seconds etching times. 2. On the scanning election microscopic examination, it was observed that the morphological patterns of etched enamel surface for 5 to 20 seconds were similar and consitent, and those for 30 to 120 seconds showed increasing over-etched patterns depending on the length of etching times. 3. The depth of etch was increased almost proportionally by the length of etching times, but it was not associated with the shear bond strength. 4. The surface roughness increased depending on the length of etching times, but it was not associated with the shear bond strength. 5. This experiment indicated that proper etching time with $38\%$ phosphoric acid solution is in the range of 5 to 30 seconds.

  • PDF

Bond strength of veneer ceramic and zirconia cores with different surface modifications after microwave sintering

  • Saka, Muhammet;Yuzugullu, Bulem
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.485-493
    • /
    • 2013
  • PURPOSE. To evaluate the effects of surface treatments on shear bond strength (SBS) between microwave and conventionally sintered zirconia core/veneers. MATERIALS AND METHODS. 96 disc shaped Noritake Alliance zirconia specimens were fabricated using YenaDent CAM unit and were divided in 2 groups with respect to microwave or conventional methods (n=48/group). Surface roughness (Ra) evaluation was made with a profilometer on randomly selected microwave (n=10) and conventionally sintered (n=10) cores. Specimens were then assessed into 4 subgroups according to surface treatments applied (n=12/group). Groups for microwave (M) and conventionally (C) sintered core specimens were as follows; $M_C$,$C_C$: untreated (control group), $M_1,C_1:Al_2O_3$ sandblasting, $M_2,C_2$:liner, $M_3,C_3:Al_2O_3$ sandblasting followed by liner. Veneer ceramic was fired on zirconia cores and specimens were thermocycled (6000 cycles between $5^{\circ}-55^{\circ}C$). All specimens were subjected to SBS test using a universal testing machine at 0.5 mm/min, failure were evaluated under an optical microscope. Data were statistically analyzed using Shapiro Wilk, Levene, Post-hoc Tukey HSD and Student's t tests, Two-Way-Variance- Analysis and One-Way-Variance-Analysis (${\alpha}$=.05). RESULTS. Conventionally sintered specimens ($1.06{\pm}0.32{\mu}m$) showed rougher surfaces compared to microwave sintered ones ($0.76{\pm}0.32{\mu}m$)(P=.046), however, no correlation was found between SBS and surface roughness (r=-0.109, P=.658). The statistical comparison of the shear bond strengths of $C_3$ and $C_1$ group (P=.015); $C_C$ and $M_C$ group (P=.004) and $C_3$ and $M_3$ group presented statistically higher (P=.005) values. While adhesive failure was not seen in any of the groups, cohesive and combined patterns were seen in all groups. CONCLUSION. Based on the results of this in-vitro study, $Al_2O_{3-}$ sandblasting followed by liner application on conventionally sintered zirconia cores may be preferred to enhance bond strength.

치경부 심미수복재의 잇솔질 마모에 관한 연구 (A STUDY ON TOOTHBRUSH ABRASION OF CERVICAL RESTORATIVE MATERIALS)

  • 백병주;양정숙;이두철;김재곤
    • 대한소아치과학회지
    • /
    • 제28권1호
    • /
    • pp.118-128
    • /
    • 2001
  • 본 연구에서는 치경부의 심미수복에 이용되고 있는 7종의 재료를 시험재료로 선택한 다음 잇솔질이 이들 수복재료의 마모도에 미치는 영향을 평가하기 위해 전동식 마모시험기를 이용하여 잇솔질 하중 2.0N으로 100,000회의 잇솔질을 시행한 다음 각 시편의 평균 두께 감소와 표면조도를 측정하였고, 표면경도가 연마성 마모에 미치는 영향을 평가하기 위해 누프 경도를 측정한 결과, 다음과 같은 결론을 얻었다. 1. 누프 경도값은 F2000 군에서 79.7로 가장 높고 Heliomolar 군에서 20.0으로 가장 낮은 값을 보였으며, Tukey 다중범위검증법에 의해서 각 군 사이의 통계적 유의성을 검증한 결과 Compoglass 군과 Dyract AP 군을 제외 한 모든 군들 사이에서 상호간에 유의 한 차이를 보였다(p<0.05). 2. 표면조도는 Improved Fuji II LC 군에서 가장 높고 UniFil F군에서 가장 낮게 나타났으며, Tukey 다중범위검증법에 의해서 각 군사이의 통계적 유의성을 검증한 결과, Improved Fuji II LC군, F2000 군과 UniFil F군 사이에서만 상호간에 유의한 차이를 보였다(p<0.05). 3. 표면조도와 마모도는 치약으로 유치용의 겔 형 페이스트인 Tom & Jerry를 사용한 경우보다 성인용의 페이스트인 Perio $A^+$를 사용한 경우에 높게 나타났다(p<0.05). 4. 연마면에서는 기질레진의 선택적인 마모에 의한 필러의 돌출로 인해 표면조도가 증가된 양상이 관찰되었다.

  • PDF

일부 세치제와 주방세제 사용에 의한 의치상 레진의 표면변화 (Surface changes of denture base resin according to two toothpastes and a kitchen detergent)

  • 강재경;김수화;유은미;최혜숙;최유리;김광만
    • 한국치위생학회지
    • /
    • 제12권3호
    • /
    • pp.611-620
    • /
    • 2012
  • Objectives : This study evaluated the changes in surface roughness of denture base resin according to the types of denture cleansers. Methods : A denture base resin(Vertex RS, Dentimax, Netherland) was used. Two toothpaste(Antiplaque, Bukwang, Korea; 2080, Aekyung, Korea) and a kitchen detergent(Trio, Aekyung, Korea) were used as a denture cleanser. The specimens were put on the V8 crossbrushing machine(Sabri enterprises, Downers grove, IL, USA) to reproduce toothbrushing and the toothbrushes were flat, round end and soft type. The surfaces of denture base resin specimens were observed by profilometer(SJ-400, MITUTOYO, Japan) and SEM(S-3000N, Hitachi Co., Ibaraki, Japan). Results : 1. According to the result of measuring surface roughness, there was statistically significant difference in Ra, Rq, and Rz(p<0.05). 2. As for Ra, Rq and Rz, Antiplaque toothpaste showed the highest roughness, and there was significant difference from other groups(p<0.01). 2080 toothpaste, Trio, and distilled water were classified as the same group. 3. According to the result of observation with the SEM, the surfaces of the Antiplaque toothpaste group after toothbrushing showed the greatest roughness, and the surfaces of 2080 toothpaste, Trio, and distilled water groups were rough in order. Trio and distilled water had the surfaces similar to those before toothbrushing. Conclusions : Studies to compare the efficacy of denture management methods and examine the effects of denture cleansers on denture materials will be helpful for dental hygienists and dentists providing patients with proper information and education. And it will be also useful for denture users' oral health.

진동하중 하에서 거친 암석 절리면의 동력 마찰거동 (Dynamic Frictional Behavior of Artificial Rough Rock Joints under Dynamic Loading)

  • 전석원;박병기
    • 터널과지하공간
    • /
    • 제16권2호
    • /
    • pp.166-178
    • /
    • 2006
  • 암반구조물의 대형, 대단면화에 따라 자유면에 노출된 암반블록의 거동특성 평가가 더욱 중요해지고 있으며, 최근 들어 지진이나 발파, 고속철도의 운행에 의한 진동 등으로 야기되는 동적하중의 발생빈도가 증가하는 추세이므로 동적 하중조건 하에서 암반 절리의 거동특성 파악을 위한 연구의 필요성이 증대되고 있다. 본 연구에서는 거친 절리면의 동적 마찰거동 특성 파악을 위해 인공 인장절리시료를 제작하고 3차원 표면거칠기 측정을 통해 인장절리면의 거칠기 특성을 분석하였으며, 다양한 조건에서 진동대 시험을 수행하였다. 절리면이 맞물린 조건에서 경사시험을 통해 구한 한계 경사각과 진동하중 하에서의 임계가속도로부터 역산한 정적 마찰각을 비교한 결과 동하중 하에서 정적 마찰각이 평균 $2.7^{\circ}$ 정도 낮게 산정되는 경향을 보였다. 엇물린 상태에서 진동하중에 의해 미끄러지는 암석블록의 가속도 및 변위 계측결과를 블록거동 프로그램에 의한 결과와 비교하여 동적 마찰각을 산정하였는데 동적 마찰각 역시 한계 경사각에 비해 평균 $1.8^{\circ}$ 감소하는 결과를 얻었다. 미끄러짐 변위패턴을 4가지로 분류하였으며 이는 절리면의 1차 거칠기와 관련있는 것으로 나타났다. 절리면이 맞물린 상태에서 측정된 한계 경사각과 정적 마찰각은 2차 거칠기를 표현하는 파라미터인 평균 거 각과 상관성을 가지는 것으로 보이나, 엇물린 상태에서 측정된 한계 경사각과 동적 마찰각은 거칠기 파라미터와 특별한 상관성을 파악할 수 없었다. 진동대 시험에 의한 동적, 정적 마찰각은 직접전단시험에 의한 마찰각 결과보다 작게 산정되었다.