• Title/Summary/Keyword: Profile measurements

Search Result 546, Processing Time 0.023 seconds

Prediction of Deformation Behavior of a Shallow NATM Tunnel by Strain Softening Analysis (연화모델을 이용한 저토피 NATM 터널의 변형거동의 예측)

  • Lee, Jae-Ho;Shinich, Akutagawa;Kim, Young-Su
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.9
    • /
    • pp.17-28
    • /
    • 2007
  • Urban tunnels are usually important in terms of prediction and control of surface settlement, gradient and ground displacement. This paper has studied the application of strain softening analysis to predict deformation behavior of an urban NATM tunnel. The applied strain softening model considered the reduction of shear stiffness and strength parameter after yielding with strain softening effects of a given material. Measurements of surface subsidence and ground displacement were adopted to monitor the ground behavior resulting from the tunneling and to modify tunnel design. The numerical analysis results produced a strain distribution, deformational mechanism and surface settlement profile, which are in good agreement with the results of case study. The approach of strain softening modeling is expected to be a good prediction method on the ground displacement associated with NATM tunneling at shallow depth and soft ground.

Prediction of tenderness in bovine longissimus thoracis et lumborum muscles using Raman spectroscopy

  • Maria Sumampa Coria;Maria Sofia Castano Ledesma;Jorge Raul Gomez Rojas;Gabriela Grigioni;Gustavo Adolfo Palma;Claudio Dario Borsarelli
    • Animal Bioscience
    • /
    • v.36 no.9
    • /
    • pp.1435-1444
    • /
    • 2023
  • Objective: This study was conducted to evaluate Raman spectroscopy technique as a noninvasive tool to predict meat quality traits on Braford longissimus thoracis et lumborum muscle. Methods: Thirty samples of muscle from Braford steers were analyzed by classical meat quality techniques and by Raman spectroscopy with 785 nm laser excitation. Water holding capacity (WHC), intramuscular fat content (IMF), cooking loss (CL), and texture profile analysis recording hardness, cohesiveness, and chewiness were determined, along with fiber diameter and sarcomere length by scanning electron microscopy. Warner-Bratzler shear force (WBSF) analysis was used to differentiate tender and tough meat groups. Results: Higher values of cohesiveness and CL, together with lower values of WHC, IMF, and shorter sarcomere were obtained for tender meat samples than for the tougher ones. Raman spectra analysis allows tender and tough sample differentiation. The correlation between the quality attributes predicted by Raman and the physical measurements resulted in values of R2 = 0.69 for hardness and 0,58 for WBSF. Pearson's correlation coefficient of hardness (r = 0.84) and WBSF (r = 0.79) parameters with the phenylalanine Raman signal at 1,003 cm-1, suggests that the content of this amino acid could explain the differences between samples. Conclusion: Raman spectroscopy with 785 nm laser excitation is a suitable and accurate technique to identify beef with different quality attributes.

Stature estimation using the sacrum in a Thai population

  • Waratchaya Keereewan;Tawachai Monum;Sukon Prasitwattanaseree;Pasuk Mahakkanukrauh
    • Anatomy and Cell Biology
    • /
    • v.56 no.2
    • /
    • pp.259-267
    • /
    • 2023
  • Stature is an essential component of biological profile analysis since it determines an individual's physical identity. Long bone dimensions are generally used to estimate the stature of skeletal remains; however, non-long bones such as the sternum, cranium, and sacrum may be necessary for some forensic situations. This study aimed to generate a regression equation for stature estimation of the skeletal remains in the Thai population. Ten measurements of the sacrum were measured from 200 dry sacra. The results revealed that the maximum anterior breadth (MAB) provided the most accurate stature prediction model among males (correlation coefficient [r]=0.53), standard error of estimation (SEE=5.94 cm), and females (r=0.48, SEE=6.34 cm). For the multiple regression model, the best multiple regression models were stature equals 41.2+0.374 (right auricular surface height [RASH])+1.072 (anterior-posterior outer diameter of S1 vertebra corpus [APOD])+0.256 (dorsal height [DH])+0.417 (transverse inner diameter of S1 vertebra corpus [TranID])+0.2 (MAB) with a SEE of 6.42 cm for combined sex. For males, stature equals 63.639+0.478 (MAB)+0.299 (DH)+0.508 (APOD) with a SEE of 5.35, and stature equals 75.181+0.362 (MAB)+0.441 (RASH)+0.132 (maximum anterior height [MAH]) with a SEE of 5.88 cm for females. This study suggests that regression equations derived from the sacrum can be used to estimate the stature of the Thai population, especially when a long bone is unavailable.

Effect of various types of dental magnetostrictive ultrasonic scaler tip on surface characteristics of titanium (여러가지 치과용 자기변형 초음파 스케일러 팁이 티타늄 표면특성에 미치는 영향)

  • Min-Cheol Yang;Seok-Hwan Jeong;Seol Kim;Seung-Hwan Seol;Seung-Kyu Lee;Sang-Joun Yu;Byung-Ock Kim
    • Journal of the Korean institute of surface engineering
    • /
    • v.57 no.4
    • /
    • pp.296-305
    • /
    • 2024
  • The aim of this in vitro study was to evaluate the changes in the roughness and weight of titanium discs treated with 3 different types of magnetostrictive ultrasonic scaler tip. Eighty identical disks (10 mm in diameter), 50 for surface roughness and 30 for weight change, were investigated in this study. For this study, 3 types of scaler tip were used as follows; Powerline(FSI-PWR-1000), Slimline(FSI-SLI-1000), and Thinsert(-16 00037374). The power was set to high power(HP), medium power(MP), and low power(LP), in the blue zone recommended by the manufacturer. Surface topography analysis was carried out using scanning electron microscopy (SEM). Surface roughness measurements, the average surface roughness (Ra) and mean roughness profile depth (Rz), were compared between treated and non-treated surfaces with a profilometer. A PowerLINE-MP of magnetostrictive ultrasonic scalers for implant patients might be recommended when considering changes in the roughness and weight of titanium discs.

Dosimetric Characteristics of Detectors in Measurement of Beam Data for Small Fields of Linear Accelerator (선형가속기의 소조사면에 대한 빔 자료 측정에서 검출기의 선량 특성 분석)

  • Koo, Ki-Lae;Yang, Oh-Nam;Lim, Cheong-Hwan;Choi, Won-Sik;Shin, Seong-Soo;Ahn, Woo-Sang
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.265-273
    • /
    • 2012
  • Aquisition of accurate beam data is very important to calculate a reliable dose distribution of the treatment planning system for small radiation fields in intensity-modulated radiation therapy(IMRT) and stereotactic radiosurgery(SRS). For the measurement of small fields, the choice of a suitable detector is important due to the shape gradient in profile penumbra, the lack of lateral electronic equilibrium, and the effect of effective detector volume. Therefore, this study was to analyze the dosimetric characteristics of various detectors in measurement of beam data for small fields of linear accelerator. 0.01cc and 0.13cc ion chambers (CC01 and CC13) and a stereotactic diode detector(SFD) were used for measurement of small fields. The beam data, including the percent depth dose, output factor, and beam profile were acquired under 6 MV and 15 MV photon beams. Measurements were performed with the field size ranging from $2{\times}2cm^2$ to $5{\times}5cm^2$. For $2{\times}2cm^2$ field size, the differences of the ratios of $PDD_{20}$ and $PDD_{10}$ measured by CC01 and SFD detectors were 1.02% and 0.12% for 6 MV and 15 MV photon beams, respectively. For field sizes larger than $3{\times}3cm^2$, the differences of values of $PDD_{20}/PDD_{10}$ obtained from each detector were 1.15% and 0.71% for 6 MV and 15 MV photon beams, respectively. The output factors obtained from CC01 and SFD for $2{\times}2cm^2$ field size were within 0.5% and 1.5% for 6 MV and 15 MV, respectively. The differences in output factor of three detectors for $3{\times}3cm^2$ to $5{\times}5cm^2$ field sizes were within 0.5%. Profile penumbras measured by the SFD, CC01, and CC13 detectors at three depths were average 2.7 mm and 3.5 mm, 3.4 mm and 4.3 mm, and 5.2 mm and 6.1 mm for 6 MV and 15 MV photon beams, respectively. In conclusion, it could be possible to use of the CC01 and SFD detectors for the measurement of percent depth dose and output factor for $2{\times}2cm^2$ field size, and to use of three detectors for $3{\times}3cm^2$ to $5{\times}5cm^2$ field sizes. CC01 and SFD detectors, consider ably smaller than the radiation field, should be used in order to accurately measure the profile penumbra for small field sizes.

Behaviors of the High-profile Arch Soil-steel Structure During Construction (높은 아치형 지중강판 구조물의 시공 중 거동 분석)

  • 이종구;조성민;김경석;김명모
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.71-84
    • /
    • 2003
  • The metallic shell of soil-steel structures are so weak in bending moment that it should sustain the applied load by the interaction of the backfill soil around the structures. The shell can be subjected to excessive bending moment during side backfilling or under live-load when the soil cover is less than the minimum value. The current design code specifies the allowable deformation and Duncan(1979) and McGrath et al.(2001) suggested the strength analysis methods to limit the moments by the plastic capacity of the shell. However, the allowable deformation is an empirically determined value and the strength analysis methods are based on the results of FE analysis, hence the experimental verification is necessary. In this study, the full-scale tests were conducted on the high-profile arch to investigate its behaviors during backfilling and under static live-loads. Based on the measurements, the allowable deformation of the tested structure could be estimated to be 1.45% of rise, which is smaller than the specified allowable deformation. The comparison between the measurements and the results of two strength analyses indicate that Duncan underestimates the earth-load moment and overestimates the live-load moment, while McGrath et al. predicts both values close to the actual values. However, as the predicted factors of safeties using two methods coincide with the actual factor of safety, it can be concluded that both methods can predict the structural stability under live-loads adequately when the cover is less than the minimum.

GafChromic Film Dosimetry for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 정위방사선 치료 시 GafChromic Film을 이용한 선량측정)

  • Han Seung Hee;Cho Byung Chul;Park Suk Won;Oh Do Hoon;Park Hee Chul;Bae Hoon Sik
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.167-173
    • /
    • 2003
  • Purpose: The purpose of this study was to evaluate whether a GafChromic film applied to stereotactic radiosurgery with a linear accelerator could provide information on the value for acceptance testing and quality control on the absolute dose and relative dose measurements and/or calculation of treatment planning system. Materials and methods: A spherical acrylic phantom, simulating a patient's head, was constructed from three points. The absolute and relative dose distributions could be measured by inserting a GafChromic film into the phantom. We tested the use of a calibrated GafChromic film (MD-55-2, Nuclear Associate, USA) for measuring the optical density. These measurements were achieved by irradiating the films with a dose of 0-112 Gy employing 6 MV photon. To verify the accuracy of the prescribed dose delivery to a target isocenter using a five arc beams (irradiated in 3 Gy per one beam) setup, calculated by the Linapel planning system the absolute dose and relative dose distribution using a GafChromic film were measured. All the irradiated films were digitized with a Lumiscan 75 laser digitizer and processed with the RIT113 film dosimetry system. Results: We verified the linearity of the Optical Density of a MD-55-2 GafChromic film, and measured the depth dose profile of the beam. The absolute dose delivered to the target was close to the prescribed dose of Linapel within an accuracy for the GafChromic film dosimetry (of $\pm$3$\%$), with a measurement uncertainty of $\pm$1 mm for the 50$\~$90$\%$ isodose lines. Conclusion: Our results have shown that the absolute dose and relative dose distribution curves obtained from a GafChromic film can provide information on the value for acceptance. To conclude the GafChromic flim is a convenient and useful dosimetry tool for linac based radiosurgery.

A STUDY ON PROFILE CHANGE AND STABILITY OF TREATMENT AFTER WEARING FACE MASK (상악골 전방견인 장치 사용후 측모 변화 및 안정성에 대한 연구)

  • Park, Young-Chel;Shin, Ja-Young;Yu, Hyung-Seog
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.1-20
    • /
    • 1997
  • Skeletal Class III malocclusions are growth-related discrepancies, and the problems are more severe until growth is complete. Causes of skeletal Class III malocclusion are classified into mandibular overgrowth, maxillary deficiency, and combination of the two. Face mask has been recommended for treatment of Class III malocclusion with maxillary deficiency in the early time of growth. Numerous experiments were performed and clinical studies have been reported on face mask ; nevertheless, studies on profile changes and stability after treatment of face mask are considered to be somewhat insufficient. The author selected 50 patients who can be checked for follow-up. They had been diagnosed as skeletal Class III malocclusion with maxillary deficiency and then treated with face mask ; the sample group was divided according to sex, treatment beginning age, palatal suture opening (intraoral appliance). For each group, changing pattern of facial profile and stability of treatment observed, and comparison with 20 Korean normal children(Angle's Class I). The following results were obtained. 1. skeletal, dental, and soft tissue measurements indicated more changes in the amounts of maxillary forward movement during face mask treatment. 2. R.P.E. group showed more significant maxillofacial changes and La-Li group showed more dental changes. 3. Growth changes of maxilla induced in the treatment group during wearing face mask were much more than those of normal group. 4. Growth changes of maxilla in the treatment group after treatment of face mask were less than those of normal group. From the obtained aata, it can be concluded that there was a stimulative effect on forward growth of maxilla during the use of face mask ; however, on removal of face mask, the stimulative effect was eliminated and undergrowth tendency of maxilla resumed.

  • PDF

Application and Comparative Analysis of River Discharge Estimation Methods Using Surface Velocity (표면유속을 이용한 하천 유량산정방법의 적용 및 비교 분석)

  • Jae Hyun, Song;Seok Geun Park;Chi Young Kim;Hung Soo Kim
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.2
    • /
    • pp.15-32
    • /
    • 2023
  • There are some difficulties such as safety problem and need of manpower in measuring discharge by submerging the instruments because of many floating debris and very fast flow in the river during the flood season. As an alternative, microwave water surface current meters have been increasingly used these days, which are easy to measure the discharge in the field without contacting the water surface directly. But it is also hard to apply the method in the sudden and rapidly changing field conditions. Therefore, the estimation of the discharge using the surface velocity in flood conditions requires a theoretical and economical approach. In this study, the measurements from microwave water surface current meter and rating curve were collected and then analyzed by the discharge estimation method using the surface velocity. Generally, the measured and converted discharge are analyzed to be similar in all methods at a hydraulic radius of 3 m or over or a mean velocity of 2 ㎧ or more. Besides, the study computed the discharge by the index velocity method and the velocity profile method with the maximum surface velocity in the section where the maximum velocity occurs at the high water level range of the rating curve among the target locations. As a result, the mean relative error with the converted discharge was within 10%. That is, in flood season, the discharge estimation method using one maximum surface velocity measurement, index velocity method, and velocity profile method can be applied to develop high-level extrapolation, therefore, it is judged that the reliability for the range of extrapolation estimation could be improved. Therefore, the discharge estimation method using the surface velocity is expected to become a fast and efficient discharge measurement method during the flood season.

A STUDY ON THE CORRELATIONSHIP OF SUBMENTOVERTEX VIEW AND LATERAL CEPHALOGRAM MEASUREMENTS (이하두정방사선사진과 측모두부방사선사진상에서의 계측치 상호연관성에 관한연구)

  • Cho, Jae-Hyung;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.26 no.4
    • /
    • pp.414-420
    • /
    • 1996
  • Cephalometric measureements have disadvantage of representing cranio-facial structures in two dimension only and therefore they pose limitations in describing three-dimentional structures of cranio-facial region. More interests have been put on the correlation between the two planes. This study evaluated correlations between facial type score, which allows effects on malocclusion, growth change prediction and establishment of treatment method and prognosis, and measurements from submentovertex view. Cephalometric view and submentovertex view were taken of skeletal Class I adults with optimal profile and correlations between them have been observed. Following results were obtained: 1. To learn about factors that influence average condylar angulation, FACE, INT-CO-ANG, MN-CORPUS, CON-RATIO, GON-RATIO, MN-RATIO were used as variables and underwent multiple regression analysis. As a result, the following equation was obtained : CON-AVE=.l73(FACE)-.322(INT-CO-ANG)+36.34(GON-RATIO) +.420(MN-CORPUS) (($R^2=.85451$) 2. The following equation was obtained concerning facial type score. FACE= .050(CON-ANG)+.023(INT-CO-ANG)-.075(MN-CORPUS)($R^2=.31547$) 3. Among the submentovertex measurements, MN-CORPUS, CON-RATIO, GON-RATIO, MN-RATIO showed close correlations. (P<0.05) 4. Average condylar angualtions were $23.37^{\circ}$ on the right and $20.71^{\circ}$ on left. There was a difference between the two. FACE : facial type soore. CON-ANG: mean value of condylar angulation. CON-AVE: mean value of Rt. Lt condylar angulation. INT-CO-ANG : angle between Rt. Lt condylar axis. MN-CORPUS : angle formed between RT. Lt gonion & pogonion. CON-RATIO: lntercondylar distance/mandibular body length. GON-RATIO : intergonion distanoe/mandibular body length. MN-RATIO: lntermylohyoid distance/mandibular body length. MX-RATIO: intermaxillary tuberosity distance/ANS-PNS distance.

  • PDF