• 제목/요약/키워드: Processing Equipment

검색결과 1,228건 처리시간 0.026초

위생교육에 따른 선식 제조기구와 작업장의 위생상태변화 및 일부 선식제품의 안정성과 영양적 평가 (Nutritional Evaluation, Stability of Cereals and Sanitation Status of Processing Utensils and Environments Based on Hygiene Education)

  • 김은미;김현숙
    • 대한지역사회영양학회지
    • /
    • 제7권6호
    • /
    • pp.833-843
    • /
    • 2002
  • This study was carried out to investigate the effect of hygiene education on the microbiological changes of processing utensils and the environmental in the manufacture of cereals and to evaluate the Cd, Pb contents and nutrient compositions of 11 cereals. The result of microbiological evaluation was that fungi, coliforms and staphylococcus species were detected in employees, on equipment, utensils and environments in the first inspection. Fungi were detected in most of the cereals, staphylococcus species were detected in soybeans, perilla seeds and sea tangle How, and bacillus cereus was detected in sorghum and black sesame seeds. The water content of rice, barley, glutinous rice, brown rice and carrot flour in packaged products, and in carrot flour, angelica keiskei, carrot, sea mustard and potato in bulk products was in excess of 8.0%. The Pb content of cereals was 0.14-0.51 mg/kg and Cd was not found. The acid value of Job s tears flour and black sesame seed flour was higher than 5.0 mg/g oil. Cereals were manufactured from 41 different cereals and grains, legumes, seeds and nuts, vegetables, potatoes, seaweeds, fruits, glucose and salt. The average content of cereals and grains, legumes, and seeds and nuts in cereals was 75.75%, 16.19% and 4.93%, respectively. The mean nutrient content per 100 g of cereals was calories 365.8kcal, protein 13.3 g, fats 5.9 g, carbohydrates 63.4 g, Ca 91.8 mg, p 269.9 mg, Fe 3.15 mg, Na 76.2 g, K 421.8 mg, Zn 2.33 mg, Vit. A 12.5 R.E., Vit. B$_1$0.23 mg, Vit. $B_2$ 0.16 mg, Vit. $B_6$ 0.46 mg, Niacin 3.5 mg, Vit. C 1.36 mg, folic acid 62.3 $\mu$g and Vit. E 1.24 mg. When nutrients value of 48 g of cereals and 200 $m\ell$l of milk was compared to 1/3 of the RDA, the values were below than 60% of 1/3 of the RDA except Na, K, Vitamin $B_1$ and C contents. The average carbohydrate : protein : fat ratio of energy intake was 54.27 : 17.45 : 28.28, respectively. Therefore, a training program consisting of the education of the staff in surveillance and standard operating procedures, the elimination of dangerous procedures, sanitation checklist, the implementation of Preparation methods and standard recipes for cereals is required.

WCDMA 시스템에서 단말 측정에 의한 압축 모드 방법 (UE Measurement Based Compressed Mode in WCDMA)

  • 김선명;장원학;조영종;임재성
    • 한국통신학회논문지
    • /
    • 제29권7A호
    • /
    • pp.814-827
    • /
    • 2004
  • WCDMA 시스템에서는 다른 주파수 또는 다른 시스템의 신호 세기를 측정하기 위하여 압축 모드(Compressed Mode)를 사용한다. 압축 모드로 동작하는 동안에는 처리 이득(Processing Gain)이 낮아지기 때문에 단말의 QoS(Quality of Service)에 영향을 끼친다. 그러므로 기지국은 단말이 요구하는 QoS를 만족시키기 위해서 전송 전력량을 증가시킨다. 한편 압축 모드의 전송 간격(Transmission Gap) 동안에는 내부 회로 전력 제어가 동작하지 않고 인터리빙(Interleaving)의 영향도 줄어들기 때문에 단말은 더 높은 Eb/No을 요구하게 된다. 따라서 시스템의 전체적인 성능 저하를 초래하게 된다. 성능에 미치는 영향 때문에, 압축 모드는 RNC(Radio Network Controller)에 의해서 다른 주파수 또는 다른 시스템의 신호 측정이 필요한 경우에만 동작하여야 한다. 그러나 3GPP는 압축 모드 동작을 결정할 수 있는 방법을 정의하지 않았다. 그러므로 성능 저하를 줄이기 위해서 압축 모드 동작을 결정할 수 있는 방법이 필요하다. 본 논문에서는 서비스 셀과 같은 주파수를 사용하는 인접 셀과 다른 주파수 또는 다른 시스템을 사용하는 인접 셀로 구성된 셀 환경에서 압축 모드가WCDMA 순방향 링크의 성능에 미치는 영향을 수식적으로 분석하고 압축 모드 사용에 따른 성능 저하를 줄이기 위하여 압축 모드가 필요하지 않은 단말의 압축모드 동작을 제한할 수 있는 단말 측정에 의한 압축 모드 방법을 제안한다. 수치적 분석 결과, 압축 모드를 사용할 때의 성능은 압축 모드를 사용하지 않을 때의 성능에 비해 급격하게 감소하는 것을 확인하였다. 그리고 제안하는 방법을 적용하였을 때, 압축 모드 사용에 따른 성능 감소를 크게 줄임을 확인하였다.

Digital X-ray장비 구축 검진차량의 웹 기반 무선 네트워크 환경 구축 전과 후의 비교분석 (Comparative Analysis of pre and Post Digital X-ray Equipment Construction and Web-Based Wireless Network Environment Construction for Medical Screening Vehicles)

  • 류영환;권대철;구은회;동경래;최성현;장영일
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.103-111
    • /
    • 2010
  • A total of 200 hospital employees participated in this study from January 2009 to June 2010. For the survey, each participant was given necessary items for external health exams. Cronbach's alpha was calculated for the survey regarding wireless networks. There was a need for educating data processing workers in the medical field regarding fundamental information prior to wireless network construction. The reason is high scores would be collected, which would reflect knowledge regarding data processing used at hospitals and the differences between paper charts and electronic charts. However, low scores were obtained which reflected knowledge regarding the differences between wired and wireless networks and Mini-PACS. Time for each patient was shortened to a maximum of three minutes and minimum of one minute for treatment and transmitting medical images when comparing pre and post wireless network construction(p < 0.01). Scores from the pre and post construction survey increase 1.98, 1.65, and 1.43 points for activity in the health screening area, usage of space in the health screening vehicle, and patient information storage respectively(p < 0.05). The number of patients receiving external health screenings twelve times was 3,655 prior to construction of a wireless network system. However, the number increased to 4,265 after construction. The increasing percentage was 17% in total. Prior to construction, X-ray images were taken 527 times, but after construction of a wireless network, this number growed to 1,194 and it was 116% increase. The loss of patient's medical treatment charts was reduced from 19.8% to 18.7% after construction. We believe that educating medical workers on Mini-PACS and Mini-OCS Systems will not only increase their efficiency but also make patients receiving better treatment.

  • PDF

펄스형 초음파 신호에서 비선형 파라미터의 정밀 추정 (Precise Estimation of Nonlinear Parameter in Pulse-Like Ultrasonic Signal)

  • 하욥;장경영
    • 비파괴검사학회지
    • /
    • 제26권2호
    • /
    • pp.77-83
    • /
    • 2006
  • 초음파 비선형성은 적층 구조물 내부의 미세크랙이나 계면 들뜸을 검출하기 위한 수단으로 주목받고 있다. 비선형 초음파의 특징적인 현상은 전파 과정중에 고조파가 발생되는 것이다. 그러므로 비선형성의 정량화를 위해서는 수신된 초음파 신호에 포함된 고조파 성분의 검출이 중요하며, 일반적으로 2차 조화 성분과 기본 주파수 성분의 진폭비가 비선형 파라미터로 이용되고 있다. 그러나 이 비선형 파라미터를 정확하게 추정할 수 있는 방법이 확립되어 있지 않기 때문에 현재까지는 현장적용에 어려움을 겪고 있다. 본 연구에서는 초음파 비선형 파라미터의 정밀 추정을 위한 신호 처리 기술을 제안하고자 한다 이 기술은 파워 스펙트럼과 바이스펙트럼 분석에 기초하며, 특히 본 연구에서는 초음파 현미경(SAM, scanning acoustic microscope)에 사용되는 펄스형 신호로부터 고조파를 검출하는데 주목하였다. 제안된 기법의 유효성은 틈새의 크기가 접촉 중심에서 반경 방향으로 일정하게 증가하는 뉴턴링(Newton-ring)과 칩의 윗면에 국부적인 들뜸을 가진 반도체 샘플에 대한 실험을 통해 검증되었다. 결과적으로 제안된 신호처리기법에 의해 획득된 비선형 파라미터는 계면 들뜸과 좋은 상관성을 보였다.

한국인(韓國人)의 고추식생활(食生活)에 관한 조사연구(調査硏究) (Survey Studies on the Korean Dietary Life of Red Pepper)

  • 박상기;전재근
    • Applied Biological Chemistry
    • /
    • 제20권1호
    • /
    • pp.95-100
    • /
    • 1977
  • To get a basic information for improving Korean's pattern of comsuming red pepper and the possibility of its industrial production, consumer's ways of red pepper processing and his present dietary habits were surveyed and the results are follows; (1) Korean's daily consumption of red pepper was on the average 9.2 g on the basis of the whole dried red pepper. (2) The tendency of evading the home drying method was increased; 72.22% in urban community and 50.4% in rural community purchased the dried red pepper in the lump yearly. The household purchasing the fresh red pepper and using the home drying was 27.8% in urban community and 49.6% in rural community, so one third of urban household was still using the home drying method. The case of dependence on tine drying factory was no more than 2.6%. (3) Drying method was mainly sun drying which done on the poor circumstance like as the street side without the proper equipment of drying. Home process of red pepper by housewife was 70.8%, and the old, housekeeper were only 7.3% respectively. (4) The hygienic sense in the drying was rare; 68.8% was not washed and 51.9% of decayed red pepper was eaten. (5) Koreans prefered the strong pungency, deep red color and fine powder form. (6) While the 45.5% of seed was collected by second hand dealer and made use of as resources of edible oil, it was not used effectively due to complexity of its collection system. (7) While 40.1% desired the improvement of red pepper dietary life, 41.1% distrusted the present commercial red pepper powder on the market. From the results above, we conclude the fact many households have still hygienically poor red pepper processed at home, in spite of the red pepper is one of the most important spices in Korea. Considering the growing urban population, reduction of unemployed labor due to the increasing nuclear family and hygienic problems caused by the serious pollution, the improvement of red pepper processing method is urgently required. And it is believed that red pepper has a good prospect to be processed on the industrial scale in Korea.

  • PDF

2차원 바코드와 UCC/EAN-128을 이용한 생물자원 자동인식시스템 (An Automatic Identification System of Biological Resources based on 2D Barcode and UCC/EAN-128)

  • 주민석;류근호;김준우;김흥태;한복기
    • 정보처리학회논문지D
    • /
    • 제15D권6호
    • /
    • pp.861-872
    • /
    • 2008
  • 컴퓨팅 환경이 발전함에 따라 다양한 물리적 객체와 디지털 정보를 연동하는 자동인식 연구가 활발히 진행 중이다. 이러한 자동인식시스템은 다양한 산업분야에서 활용되고 있음에도 불구하고 보건의료와 관련한 자동인식 기술의 접목은 아직까지 다른 산업기술 전반에 미치지 못하고 있는 실정이다. 이에 따라 의료장비, 혈액, 인체조직 등 보건의료 용품의 자동인식에 관한 여러 연구가 진행 중이다. 이 논문은 인간 유전체 연구의 필수 연구재료인 생물자원을 대상으로 자동인식 기술의 적용 방안을 제안한다. 먼저, 자동인식기술 도입을 위해 사용 환경상의 고려사항을 정의하고, 조사과정 또는 실험을 통하여 적합한 형태의 태그 인터페이스로서 바코드를 선택하였다. 바코드 심볼로지는 2차원 바코드 심볼로지인 Data Matrix를 사용하고, 데이터 스키마는 국제적 범용성 추구를 위하여 UCC/EAN-128 기반으로 설계하였다. 제안된 기술들이 실제 환경에 적용되는지를 보이기 위한 어플리케이션을 개발하고, 이에 대한 실험 및 평가를 다음의 방법으로 수행하였다. 생물자원이 실제 보존되는 영하 $196^{\circ}C$, 영하 $75^{\circ}C$의 초저온 보존환경에서 바코드 인식실험을 한 결과 1.6초 내외의 평균 인식시간을 보이며, 데이터 스키마는 생물자원 활용 분야의 요구사항을 만족하는 것으로 평가되었다. 따라서 제안한 방법으로 생물자원의 정보처리 과정에서 정확성과 데이터 입력의 신속성이 제공될 수 있다.

허리 근골격계질환 예방 보조 조끼의 효과에 대한 실험적 연구 (An Experimental Study on the Effect of Supporting Vest for Musculoskeletal Disorders in Low Back)

  • 김윤정;장지훈;조요한;정진형;정하영;이상식
    • 한국정보전자통신기술학회논문지
    • /
    • 제13권3호
    • /
    • pp.219-225
    • /
    • 2020
  • 인구고령화에 따라 노인의 근골격계질환의 유병률이 계속해서 증가하고 있다. 또한 근골격계질환은 2015년 기준으로 산재보험 보상급여에서 업무상질병 중 상위 세 번째로 사회 및 경제적 손실을 초래한 질환으로서 근로자들에게도 많이 발생하는 질병이다. 본 연구에서는 허리의 근골격계질환의 예방과 치료에 보조할 수 있는 조끼를 제작하여 실험을 통해 그 효과의 유무를 확인하고자 한다. 허리부분의 질환은 코어근육과 밀접한 연관이 있다. 따라서 제작한 조끼는 코어근육을 지지해 주는 형태로 제작하였다. 효과 검증을 위해 조끼의 착용 전과 후에 허리 신전 운동인 멕켄지 운동을 10회 실시하면서 코어근육에 해당되는 배속빗근(내복사근, Internal oblique), 배곧은근(복직근, Rectus abdominis), 척추세움근(척추기립근, Erector spinae)의 근전도 데이터를 수집하고 수집한 데이터를 근전도 분석 프로그램인RM-3를 통해 분석하여 각 근육의 10회 측정 시 RMS값을 구하고 그 평균값을 비교하는 실험을 진행했다. 데이터비교 이후 유의성 검증을 위해 PASW ver18.0을 통해 측정결과의 기술통계치 산출과 평균차를 검증하고, 실험 결과치에 대응표본 T검정을 시행하여 통계 처리를 했다. 통계분석의 유의 수준은 α=.05로 설정하고 통계처리를 진행하였다.

폴리(부틸렌 테레프탈레이트)의 물성에 대한 윤활제의 효과 (Effect of Lubricants on the Physical Properties of Poly(butylene terephthalnte))

  • 김효갑;김준경;임순호;이건웅;박민;강호종
    • 폴리머
    • /
    • 제28권3호
    • /
    • pp.239-244
    • /
    • 2004
  • 윤활제 첨가에 따른 폴리(부틸렌 테레프탈레이트) [PBT]의 유변 특성 및 열 안정성 변화에 대하여 살펴보았다. 윤활제로 칼슘 스테아레이트 (CaST)와 아디프산 글리콜 폴리에스터 (AhGP)를 PBT에 첨가하는 경우 1 wt% 첨가만으로도 용융 점도가 현저히 감소함을 알 수 있었다. 이러한 정도 감소는 AAGP의 경우, PBT 주사슬에 내부 윤활제로 그리고 CaST는 가공 기기 표면과의 윤활 특성을 향상시키는 외부 윤활제로 작용하여 발현되며, 아울러 윤활제에 의한 PBT분자량 감소에도 기인됨을 확인할 수 있었다. 또한 본 연구에서 사용한 윤활제는 PBT의 열 안정성을 저하시키는 요인으로 작용함을 알 수 있었으나 3 wt% 이하의 CaST를 PBT에 적용하는 경우 열 안정성의 감소를 최소화 할 수 있었다. 이러한 결과로 부터 분자량 감소와 열 안정성 저하를 최소화하면서 동시에 점도를 낮출 수 있는 PBT윤활제로는 내부 윤활제보다는 외부 윤활제인 CaST가 적절함을 알 수 있었다.

광대역 VLBI 관측을 위한 32Gbps 관측장비의 시험결과 고찰 (A Study on the Test Results of 32 Gbps Observing System for Wideband VLBI Observation)

  • 오세진;염재환;노덕규;정동규;하라다 켄이치;타케자와 코스케
    • 융합신호처리학회논문지
    • /
    • 제18권1호
    • /
    • pp.13-20
    • /
    • 2017
  • 본 논문에서는 KVN의 광대역 VLBI 관측을 위한 백엔드 시스템으로써 도입한 32 Gbps 급 관측장비의 기본적인 시험결과에 대해 고찰한다. 천문학자들은 천체의 초미세 구조를 관측하고자 성능이 우수한 큰 전파망원경을 만들고 싶지만, 많은 돈이 소요된다. 따라서 민감도를 높이기 위해 수신시스템의 성능개선이나 넓은 주파수 대역폭을 관측하는 방법을 도입하고 있다. 이를 위해 본 연구에서는 넓은 관측 주파수 대역폭을 관측하기 위해서는 아날로그 신호를 초고속으로 변환하는 광대역 샘플링 방법과 디지털 필터링을 수행하는 광대역 샘플러를 도입하였다. 광대역 샘플러(OCTAD-K)는 최대 16Gsps-2bit 샘플링을 지원하며, 디지털필터링 기술을 이용하여 다양한 관측대역폭의 관측을 지원한다. 특히 KVN의 4주파수 동시관측시스템과 VERA의 2-beam 관측시스템을 지원할 수 있도록 설계되었다. 그리고 편파관측도 지원할 수 있으며, 관측데이터의 출력의 표준 VDIF 형식을 지원한다. 본 논문에서는 광대역 샘플러를 도입하기 전 수행한 공장검수와 현장시험을 수행한 후 시스템의 성능결과와 문제점 해결 등에 대해 자세히 기술한다.

  • PDF

최소화된 계측 및 신호 처리 시스템을 이용한 상시진동 케이블의 효율적인 장력 추정에 관한 연구 (A Study on the Efficient Tension Estimation of Cables under Ambient Vibration using Minimized Measurement and Signal Processing System)

  • 이형진
    • 한국산학기술학회논문지
    • /
    • 제19권11호
    • /
    • pp.594-603
    • /
    • 2018
  • 최근 계측 기술의 발달에 따라 종래의 복잡하고 시간 소모적인 현장 계측분석 작업을 단순하고 편리하게 만드는 작업이 가능해지고 있다. 이런 배경에서 이 논문에서는 최소화된 계측 및 신호처리를 통해 상시진동 케이블의 장력을 추정하는 문제에 대해 연구하였다. 최소화 계측 방법으로는 저가 영상장비로 촬영된 동영상만을 이용하는 영상 변위 계측을 구상하였다. 또한 이로 인한 유효 주파수 대역 부족 문제의 해결을 위해 미러 주파수를 이용한 고유진동수 추정 방법을 제시하였다. 더불어 현장 사용 성능과 관련한 상시진동 문제를 처리하기 위해 신호처리 및 고유진동수 추정법으로 FDD 방법이 채택되었다. 제안된 최소화 계측 시스템과 미러 주파수 개념의 특성 및 FDD 방법의 적용성을 보기 위하여 사장교 모형을 이용한 실험적 연구가 수행되었다. 실험 결과는 상시진동을 위한 FDD 방법이 최소화 시스템을 이용한 고유 진동수 판별에서도 효과적으로 잘 작동됨을 보여 주었다. 또한 미러 주파수 개념은 저속촬영에 따라 왜곡된 신호에서도 고주파수 영역에 있는 고유진동수 추정이 가능함을 보여 최소화 시스템의 한계돌파에 효과적임을 보여 주었다. 결론적으로 실험결과는 제안된 최소화 계측 및 신호처리 시스템이 상시진동 케이블 장력 추정에 효과적인 방법이 될 수 있음을 보여주었다.