• Title/Summary/Keyword: Process-driven evaluation

Search Result 96, Processing Time 0.024 seconds

Development of gear type grease lubricator by rapid prototyping (쾌속조형기에 의한 기어식 주유장치의 개발)

  • Wang, Duck Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.6
    • /
    • pp.46-53
    • /
    • 2014
  • An automatic grease lubricator provides an adequate amount of fresh grease constantly to any type of rotating machine to minimize friction heat and reduce friction loss. This study seeks to develop an automatic grease lubricator by means of rapid prototyping with a gear-driven mechanism and a controlled operation time. The ultimate design is to lubricate an adequate amount of grease by a simple dip-switch clicking mechanism according to an advanced set cycle. The backlash of the gear was minimized to increase the power, and to increase the power of the mechanism, the binding frequency and the thickness of the coil were changed. To control the rotation cycles of the main shaft according to certain set numbers, different resistances and chips were used in the design of the circuit which controls the electrical signals via a pulse. A digital mock-up was analyzed and the rapid prototyping (RP) trial products were tested with a PCB circuit and grease. An evaluation of the outlet capacity of RP trial products was conducted, as the friction caused by the outlet on the wall surface was an important factor in the operation of the equipment. Finally, a finishing process was applied to decrease the roughness of a surface to a comparable level to test the performance of the product.

Development of Multi-axis Nano Positioning Stage for Optical Alignment (광소자 정렬용 극초정밀 다축 위치 제어장치 개발)

  • 정상화;이경형;차경래;김현욱;최석봉;김광호;박준호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.304-307
    • /
    • 2004
  • As optical fiber communication grows, the fiber alignment become the focus of industrial attention. This greatly influence the overall production rates for the opto-electric products. We proposed multi-axis nano positioning stage for optical fiber alignment. This device has 3 DOF translation and sub nanometer resolution. This nano stage consist of 3 PZT-driven flexure stages which are stacked parallel. The displacement of it is measured with capacitance gauge and is controlled by computer-embedded main controller. The design process of flexure stage using FEM is proposed and the performance evaluation of this system is verified with experiments.

  • PDF

A Study on Endurance Estimation of 3D Sprag Type Ultra Precision Reverse-Locking Clutches under Contact Condition (접촉상태에 있는 의 초정밀 역전방지클러치의 3D SPRAG TYPE 내구성 평가에 관한 연구)

  • 이상범;서정세;이석순;이태선;최중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1429-1433
    • /
    • 2004
  • Recently, a dangerous event occurred at the field industry and mechanical system. At developed by SUNGGOK corp. a R-L clutches of a small and high capacity serves safety device from a variety environment of mechanical system, it permits transmission of driving torque form input to output shaft in both directions of rotation, but restrains any feedback torque of the driven load from rotating the output shaft in either direction. This study was carried out to demonstrate through finite element methode and durability estimation for safety of the R-L clutches without sliding during the engagement process. As results, we organized about endurance test methode when applied rated torque.

  • PDF

Development of Target-Controlled Infusion system in Plasma Concentration. PART2: Design and Evaluation (혈중 목표 농도 자동 조절기(TCI) 개발 PART2: 시스템 구현 및 평가)

  • 안재목
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.45-53
    • /
    • 2003
  • Based on the 4-compartmental pharmacokinetic model developed in PART1, target-controlled infusion(TCI) pump system was designed and evaluated. The TCI system consists of digital board including microcontroller and digital signal process(DSP), analog board, motor-driven actuator, user friendly interface, power management and controller. It provides two modes according to the drugs: plasma target concentration and effect target concentration. Anaesthetist controls the depth of anaesthesia for patients by adjusting the required concentration to maintain both plasma and effect site in drug concentration. The data estimated in DSP include infusion rate, initial load dose, and rotation number of motor encoder. During TCI operation, plasma concentration. effect site concentration, awaken concentration, context-sensitive decrement time and system error information are displayed in real time. Li-ion battery guarantees above 2 hours without power line failure. For high reliability of the system, two microprocessors were used to perform independent functions for both pharmacokinetic algorithm and motor control strategy.

Medeical Therapy For Pulmonary Arterial Hypertention (폐동맥고혈압에서 폐혈관계 작용약물)

  • Choi, Hye Sook;Lee, Sang Do
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.2
    • /
    • pp.142-150
    • /
    • 2006
  • Pulmonary arterial hypertension (PAH) is often difficult to diagnose and challenging to treat. Untreated, it is characterized by a progressive increase in pulmonary vascular resistance leading to right ventricular failure and death. The past decade has seen remarkable improvements in therapy, driven largely by the conduct of randomized controlled trials. Still, the selection of most appropriate therapy is complex, and requires familiarity with the disease process, evidence from treatment trials, complicated drug delivery systems, dosing regimens, side effects, and complications. We tried to provide evidence-based treatment recommendations for physicians involved in the care of these complex patients. Due to the complexity of the diagnostic evaluation required, and the treatment options available, it is strongly recommended that consideration be given to referral of patients with PAH to a specialized center.

Focal Length Measurement System for Camera Lens using the MTF (MTF 방법에 의한 카메라 렌즈 초점 자동 측정 시스템 개발)

  • 이석원;이동성;박희재;문호균;김영식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.264-270
    • /
    • 1996
  • In this paper, a computer automated system has been developed for measuring the focal length of camera lens using the MTF(Modurar Transfer Function) based on the signal processing around a line CCD and autocollimator. An optical Path for the focal length measurement system has been designed around thelight sourec, collimator, camera, mirror and the line CCD. The eyepiece of the collimator is replaced byline CCD, and the mirror is moved along the focal axis by a PC driven step motor. An efficient method has been designed for finding the optimum MTF value for the focal length based on the least squares approach. The developed system is fullycomputer automated: signal transmission to and from the camera, MTF evaluation based on the line CCD, step motor contorl, etc. The developed system has been applied to a practical camera manufacturing process and demonstrated its performance

  • PDF

A Study on the Linear Motor Control System (니리어모터 이송계 제어 특성분석에 관한 연구)

  • Yoo, Song-Min
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.466-471
    • /
    • 2003
  • In order to analyze linear motor driven feed system, preliminary studies have been conducted focusing on the performance evaluation of the system based on the various combination of control gain along with acceleration. Tentative simulation revealed that due to the complexity of control system reduced number of control condition is recommended. Actual machining process with conventional feed system using endmill tool was employed as a preliminary study. Several sensing methods including AE, acceleration sensors and tool dynamometer were used. Results revealed the consistency in AE and cutting resistance. There were inconsistent empirical results in accelerometer probably due to the insensitivity of the sensor signal with respect to the experimental system

  • PDF

Development of Multi-Axis Ultra Precision Stage for Optical Alignment (광소자 정렬용 초정밀 다축 스테이지 개발)

  • 정상화;이경형;김광호;차경래;김현욱;최석봉;박준호
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.213-218
    • /
    • 2004
  • As optical fiber communication grows, the fiber alignment become the focus of industrial attention. This greatly influence the overall production rates for the opto-electric products. We proposed multi-axis nano positioning stage for optical fiber alignment. This device has 3 DOF translation and sub nanometer resolution. This nano stage consist of 3 PZT-driven flexure stages which are stacked parallel. The displacement of it is measured with capacitance gauge and is controlled by computer-embedded main controller. The design process of flexure stage using FEM is proposed and the performance evaluation of this system is verified with experiments.

  • PDF

Performance Improvement of MOS type FDIS using Fuzzy Logic (퍼지논리를 이용한 다중관측자 구조 FDIS의 성능개선)

  • Ryu, Ji-Su;Park, Tae-Geon;Lee, Kee-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.410-413
    • /
    • 1998
  • A passive approach for enhancing fault detection and isolation performance of multiple observer based fault detection isolation schemes(FDIS) is proposed. The FDIS has a hierarchical framework to perform detection and isolation of faults of interest, and diagnosis of process faults. The decision unit comprises of a rule base and fuzzy inference engine and removes some difficulties of conventional decision unit which includes crisp logic and threshold values. Emphasis is placed on the design and evaluation methods of the diagnostic rule base. The suggested scheme is applied for the FDIS design for a DC motor driven centrifugal pump system.

  • PDF

Development of Heat Transfer and Evaporation Correlations for the Turbulent Natural Convection in the Vertical Channel by Using Numerical Analysis

  • Kang, Han-Ok;Lee, Un-Chul
    • Nuclear Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.532-541
    • /
    • 1996
  • Theoretical and numerical study on heat transfer and evaporation in the vertical channel has been carried out and basic correlations have been derived for the heat transfer evaluation of PCCS. Analysis program was developed with low-Reynolds-number k-$\varepsilon$ model and surface transfer rates were calculated for the turbulent natural convection in the vertical channel. In relation to dry cooling by buoyancy-driven air, first, the system parameters which govern overall heat transfer rate are determined through the adequate nondimensionalization procedure. After comparison with existing experimental data, numerical results are used to derive heat transfer correlation by sensitivity calculations. In relation to wet cooling by falling water film, numerical analysis are carried out for evaporation process with real film surface conditions and evaporation correlation is derived through analogy concept and correction factors.

  • PDF