• Title/Summary/Keyword: Procedural rupture

Search Result 14, Processing Time 0.02 seconds

Endovascular Treatment of Aneurysms Arising from the Proximal Segment of the Anterior Cerebral Artery

  • Ko, Jun Kyeung;Cha, Seung Heon;Lee, Tae Hong;Choi, Chang Hwa;Lee, Sang Weon;Lee, Jae Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.2
    • /
    • pp.75-80
    • /
    • 2013
  • Objective : Aneurysms arising from the proximal segment of the anterior cerebral artery (A1) are rare and challenging to treat. The aim of this study was to report our experience with endovascular treatment of A1 Aneurysms. Methods : From August 2007 through May 2012, eleven A1 aneurysms in eleven patients were treated endovascularly. Six aneurysms were unruptured and 5 were ruptured. One patient with an unruptured A1 aneurysm presented with subarachnoid hemorrhage due to rupture of an anterior communicating artery aneurysm. Procedural data, clinical and angiographic results were reviewed retrospectively. Results : All of the aneurysms were successfully treated with coil embolization. Six were treated with a simple technique while the remaining 5 required adjunctive technique : double catheters (n=2), balloon-assisted (n=2), and stent-assisted (n=1). The immediate angiographic control showed a complete occlusion in all cases. Procedure-related complication occurred in only one patient : parent artery occlusion, which was not clinically significant. All patients had excellent clinical outcomes but one patient was discharged with a slight disability. No neurologic deterioration or bleeding was seen during the follow-up period in this cohort of patients. Follow-up angiography (mean, 20 months) was available in ten patients and revealed stable occlusion in all cases. Conclusion : Endovascular treatment is a feasible and effective therapeutic modality for A1 aneurysms. Tailored microcatheter shaping and/or adjunctive techniques are necessary for successful aneurysm embolization because of the projection and location of A1 aneurysms.

Safety and Efficacy of Transluminal Balloon Angioplasty Using a Compliant Balloon for Severe Cerebral Vasospasm after an Aneurysmal Subarachnoid Hemorrhage

  • Choi, Beam-Jin;Lee, Tae-Hong;Lee, Jae-Il;Ko, Jun-Kyeung;Park, Hwa-Seung;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.3
    • /
    • pp.157-162
    • /
    • 2011
  • Objective : Vasospasm of cerebral vessels remains a major source of morbidity and mortality after an aneurysmal subarachnoid hemorrhage (SAH). The purpose of this study was to evaluate the safety and efficacy of transluminal balloon angioplasty (TBA) for SAH-induced vasospasm. Methods : Eleven patients with an angiographically confirmed significant vasospasm (>50% vessel narrowing and clinical deterioration) were studied. A total of 54 vessel segments with significant vasospasm were treated by TBA. Digital subtraction angiography was used to confirm the presence of vasospasm, and TBA was performed to dilate vasospastic arteries. Medical and angiographic reports were reviewed to determine technical efficacy and for procedural complications. Results : TBA using Hyper-Glide or Hyper-Form balloons (MicroTherapeutics, Irvine, CA) was successfully accomplished in 88.9% vasospastic segments (48 of 54), namely, in the distal internal carotid artery (100%, n=7), the middle cerebral artery (100%), including the M1 (n=10), M2 (n=10), and M3 segments (n=4), in the vertebral artery (100%, n=2), basilar artery (100%, n=1), and in the anterior cerebral artery (ACA), including the A1 (66%), A2 (66%), and A3 segments (100%). Vessel diameters significantly increased after TBA. There were no cases of vessel rupture or thromboembolic complications. GCS at one day after TBA showed an improvement in all patients except one. Conclusion : This study suggests that TBA using Hyper-Glide or Hyper-Form balloons is a safe and effective treatment for subarachnoid hemorrhage-induced cerebral vasospasm.

Four-Year Experience Using an Advanced Interdisciplinary Hybrid Operating Room : Potentials in Treatment of Cerebrovascular Disease

  • Jeon, Hong Jun;Lee, Jong Young;Cho, Byung-Moon;Yoon, Dae Young;Oh, Sae-Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.1
    • /
    • pp.35-45
    • /
    • 2019
  • Objective : To describe our experiences with a fully equipped high-end digital subtraction angiography (DSA) system within a hybrid operating room (OR). Methods : A single-plane DSA system with 3-dimensional rotational angiography, cone-beam computed tomography (CBCT), and real-time navigation software was used in our hybrid OR. Between April 2014 and January 2018, 191 sessions of cerebrovascular procedures were performed in our hybrid OR. After the retrospective review of all cases, the procedures were categorized into three subcategorical procedures : combined endovascular and surgical procedure, complementary rescue procedure during intervention and surgery, and frameless stereotaxic operation. Results : Forty-nine of 191 procedures were performed using hybrid techniques. Four cases of blood blister aneurysms and a ruptured posterior inferior cerebellar artery aneurysm were treated using bypass surgery and endovascular trapping. Eight cases of ruptured aneurysm with intracranial hemorrhage (ICH) were treated by partial embolization and surgical clipping. Six cases of ruptured arteriovenous malformation with ICH were treated by Onyx embolization of nidus and subsequent surgical removal of nidus and ICH. Two (5.4%) of the 37 cases of pre-mature rupture during clipping were secured by endovascular coil embolization. In one (0.8%) complicated case of 103 intra-arterial thrombectomy procedures, emergency surgical embolectomy with bypass surgery was performed. In 27 cases of ICH, frameless stereotaxic hematoma aspiration was performed using $XperGuide^{(R)}$ system (Philips Medical Systems, Best, the Netherlands). All procedures were performed in single sessions without any procedural complications. Conclusion : Hybrid OR with a fully equipped DSA system could provide precise and safe treatment strategies for cerebrovascular diseases. Especially, we could suggest a strategy to cope flexibly in complex lesions or unexpected situations in hybrid OR. CBCT with real-time navigation software could augment the usefulness of hybrid OR.

Feasibility and efficacy of coil embolization for middle cerebral artery aneurysms

  • Choi, Jae Young;Choi, Chang Hwa;Ko, Jun Kyeung;Lee, Jae Il;Huh, Chae Wook;Lee, Tae Hong
    • Journal of Yeungnam Medical Science
    • /
    • v.36 no.3
    • /
    • pp.208-218
    • /
    • 2019
  • Background: The anatomy of middle cerebral artery (MCA) aneurysms has been noted to be unfavorable for endovascular treatment. The purpose of this study was to assess the feasibility and efficacy of coiling for MCA aneurysms. Methods: From January 2004 to December 2015, 72 MCA aneurysms (38 unruptured and 34 ruptured) in 67 patients were treated with coils. Treatment-related complications, clinical outcomes, and immediate and follow-up angiographic outcomes were retrospectively analyzed. Results: Aneurysms were located at the MCA bifurcation (n=60), 1st segment (M1, n=8), and 2nd segment (M2, n=4). Sixty-nine aneurysms (95.8%) were treated by neck remodeling techniques using multi-catheter (n=44), balloon (n=14), stent (n=8), or combination of these (n=3). Only 3 aneurysms were treated by single-catheter technique. Angiographic results were 66 (91.7%) complete, 5 (6.9%) remnant neck, and 1 (1.4%) incomplete occlusion. Procedural complications included aneurysm rupture (n=1), asymptomatic coil migration to the distal vessel (n=1), and acute thromboembolism (n=10) consisting of 8 asymptomatic and 2 symptomatic events. Treatment-related permanent morbidity and mortality rates were 4.5% and 3.0%, respectively. There was no bleeding on clinical follow-up (mean, 29 months; range, 6-108 months). Follow-up angiographic results (mean, 26 months; range, 6-96 months) in patients included 1 major and 3 minor recanalizations. Conclusion: Coiling of MCA aneurysms could be a technically feasible and clinically effective treatment strategy with acceptable angiographic and clinical outcomes. However, the safety and efficacy of this technique as compared to surgical clipping remains to be ascertained.