Finasteride $[N-(1, 1-dimethylethyl)-3-oxo-4-aza-5{\alpha}-androst-1-ene-17{\beta}-carboxamide]$ is a 4-aza-3-oxosteroidal inhibitor of human $5{\alpha}-reductase$. The purpose of the present study was to evaluate the bioequivalence of two finasteride tablets, $Proscar^{\circledR}$ (MSD Korea Ltd.) and Procare (Hana Pharm. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of finasteride from the two finasteride formulations in vitro was tested using KP VIII Apparatus II method with various dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty six healthy male subjects, $23.7\;{\pm}\;2.24$ years in age and $67.2\;{\pm}\;8.55\;kg$ in body weight, were divided into two groups and a randomized $2\;{\time}\;2$ cross-over study was employed. After two tablets containing 5 mg as finasteride was orally administered, blood samples were taken at predetermined time intervals and the concentrations of finasteride in serum were determined using HPLC with UV detector. The dissolution profiles of two formulations were similar in all tested dissolution media. The pharmacokinetic parameters such as $AUC_t,\;C_{max},\;and\;T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t,\;C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Proscar^{\circledR}$, were 6.39, 4.65 and -13.9% for $AUC_t,\;C_{max},\;and\;T_{max},$ respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.800 to log 1.25 $(e.g.,\;log\;0.990{\sim}log\;1.14\;and\;log\;0.977{\sim}log\;1.13 for\;AUC_t\;and\;C_{max},\;respectively)$. Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Procare tablet was bioequivalent to $Proscar^{\circledR}$ tablet.
de Oliveira Monteiro, Marco Antonio;Antunes, Alberto Nogueira da Gama;Basting, Roberta Tarkany
Journal of Dental Anesthesia and Pain Medicine
/
제21권2호
/
pp.139-153
/
2021
Background: In anesthetic techniques, touching bones can cause needle bending. Theoretically, a needle should support such deflection without fracturing. However, it is possible that a needle may fracture depending on the quality and type of needle used. This study evaluated the physical, chemical, and micromorphological characteristics of long and short dental anesthetic needles, as well as the mechanical properties of flexural load and bending resistance when needles are subjected to different bending angles. Methods: Long and short needles (30G, Jets, Misawa, Selekto, Terumo, Unoject and 27G, Dencojet, Injex, Jets, Misawa, Procare, Setoject XL, Terumo) were evaluated. Scanning electron microscopy was used to evaluate the needle bevels and energy-dispersive X-ray spectroscopy was used for the chemical analysis of needle compositions. Flexural loading and bending strength assessments were performed using a universal testing machine by bending the needles (n = 5) to angles of 30°, 60°, or 90°, or until fracture occurred. Results: The Injex 27G, Jets 27G, and Septoject XL 27G needles were all less than 30 mm in length. There were small percentage variations in the chemical compositions of the needles. Superior smoothness was observed for the Unoject 30G needle, which exhibited the highest fracture resistance at 60°. The Jets 30G needle exhibited greater resistance to fractures at 90°. The Procare 27G needle exhibited the highest load resistance to bending, followed by the Septoject XL 27G needle, and both needles were tied for the lowest fracture resistance. No needle fractured when bent to 30° or at less than three bends to 60° or 90°. Conclusions: Greater needle resistance to bending increases the probability of early fracturing. Thinner and shorter needles are more resistant than longer and thicker needles. Performing a single bend does not result in any significant risk of fracture or obliterate the lumen, allowing for the continued passage of anesthetic liquid.
목 적 : 소아 청소년 건강관리에서 혈압 측정의 중요성이 점차 강조되고 있는 시점에서 한국의 소아 청소년들을 위한 정상 혈압 참고 치를 만들고자 하였다. 방 법 : 2005년에 새로운 신체성장 표준치를 만들기 위해 시행한 전국 소아 청소년들의 신체계측사업에 혈압 계측사업을 포함시켜 7-20세에 해당하는 소아 청소년 57,433명(남: 29,443명, 여: 27,990명)에서 신장, 체중 및 혈압 계측치를 얻었다. 혈압은 자동 진동혈압계인 Dinamap Procare 200(GE Inc., Milwaukee, Wi, USA)를 이용하여 측정하였고 앉은 자세에서 안정한 후 우측 팔에서 5분 간격으로 2번 측정하였다. 두 측정치의 평균치를 수축기 혈압과 이완기 혈압으로 기록하여 원 자료로 하였다. 체중이 +3SD 이상인 과체중아들 2,373명의 혈압은 제외하고 분석 하였다. 혈압 백분위수 표는 성별, 연령별, 신장 백분위수별로 만들어 졌으며 통계기법은 2004 Task Force in NHLBI (USA)이 사용한 통계기법을 원용한 고정 변형 LMS 방법을 사용하였다. 결 과 : 성별, 연령별(7-18세), 신장 백분위수별(5th, 10th, 25th, 50th, 75th, 90th, 95th) 혈압 참고치가 완성되었으며 신장 백분위수에 대한 자료는 질병관리본부 홈페이지인 http://www.cdc.go.kr/webcdc/에서 확인 할 수 있다. 고혈압의 기준치는 성별, 연령별, 신장대비에서 95 백분위수 이상으로 하고, 전고혈압 기준치는 90-95 백분위수 또는 수축기 및 이완기 혈압 130/80 mmHg 이상으로 정하였다. 결 론 : 이번에 마련된 우리나라 소아 청소년 정상 혈압 참고치는 처음이기 때문에 사용기준 및 고혈압의 기준은 앞으로 지속적인 논의와 연구가 필요할 것으로 생각된다. 또한 본 혈압 표는 자동 진동혈압계로 마련된 것이기 때문에 수동 수은 혈압계를 이용한 혈압 치를 평가하는 기준표로 사용하는 것은 주의해야 할 것이다.
Plaku-Alakbarova, Bora;Punnett, Laura;Gore, Rebecca J.;Procare Research Team
Safety and Health at Work
/
제9권4호
/
pp.408-415
/
2018
Background: Nursing home resident care is an ongoing topic of public discussion, and there is great interest in improving the quality of resident care. This study investigated the association between nursing home employees' job satisfaction and residents' satisfaction with care and medical outcomes. Methods: Employee and resident satisfaction were measured by questionnaire in 175 skilled nursing facilities in the eastern United States from 2005 to 2009. Facility-level data on residents' pressure ulcers, medically unexplained weight loss, and falls were obtained from the Centers for Medicare and Medicaid Services Long-Term Care Minimum Data Set. The association between employee satisfaction and resident satisfaction was examined with multiple and multilevel linear regression. Associations between employee satisfaction and the rates of pressure ulcers, weight loss, and falls were examined with simple and multilevel Poisson regression. Results: A 1-point increase in overall employee satisfaction was associated with an increase of 17.4 points (scale 0-100) in the satisfaction of residents and family members (p < 0.0001) and a 19% decrease in the incidence of resident falls, weight loss, and pressure ulcers combined (p < 0.0001), after adjusting for staffing ratio and percentage of resident-days paid by Medicaid. Conclusion: Job satisfaction of nursing home employees is associated with lower rates of resident injuries and higher resident satisfaction with care. A supportive work environment may help increase quality of care in the nation's nursing homes.
목 적 : 소아 고혈압은 성별, 연령별, 신장별 수축기 또는 이완기 혈압이 95 백분위수 이상으로, 진동식 자동 혈압계에 의한 소아 혈압치는 일부 연령에서만 보고되어 있고, 최근 6세 이하의 어린 소아에서 보고가 적다. 이에 저자들은 진동식 자동 혈압계를 이용하여 신생아부터 6세 이하의 정상 소아를 대상으로 성별, 연령별, 신장 백분위수별 수축기 및 이완기 혈압을 측정하여 정상 혈압치 및 혈압 백분위수 곡선을 구하여 우리나라 소아의 고혈압 진단과 치료에 도움이 되고자 본 연구를 실시하였다. 방 법 : 서울 시내 6세 이하의 어린이 6,690명(남아 3,545명, 여아 3,145명)을 대상으로 진동식 자동 혈압계(Dinamap, Procare-200, GE, USA)를 이용하여 수축기 혈압과 이완기 혈압을 각각 두 차례에 걸쳐 측정하였으며, 이를 이용하여 연령별, 성별 평균 혈압을 구하고, 신장 5, 10, 25, 50, 75, 90, 95 백분위수에 따른 50, 90, 95, 99 백분위수의 혈압을 산출하였고 혈압 백분위수 곡선을 구하였다. 수축기 혈압과 이완기 혈압은 성별 고정효과모형을 적용하여 선형회귀모형에서 회귀계수와 표준편차를 구하였다. 결 과 : 남아와 여아 모두에서 연령이 증가함에 따라 수축기 혈압과 이완기 혈압이 점차 증가하였다. 남아와 여아 모두 동일한 신장 백분위수를 가진 어린이들이 연령이 증가함에 따라서 수축기 혈압과 이완기 혈압 모두 증가하는 양상을 보였다. 남아와 여아 모두 동일한 연령대에서 신장이 커질수록 수축기 혈압과 이완기 혈압 모두 증가하는 양상을 보였다. 결 론 : 진동식 자동 혈압계를 이용하여 서울지역 6세 이하 어린이의 성별, 연령 및 신장 백분위수에 따른 혈압 백분위수를 구하였다. 이번 연구 자료가 6세 이하의 고혈압을 진단하고 치료하는데 큰 도움이 되리라 생각한다. 앞으로 고혈압 진단과 치료를 위해서는 서울시가 아닌 우리나라 전국 소아를 대상으로 한 대규모 연구가 필요하다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.