• Title/Summary/Keyword: Problem Statement

Search Result 515, Processing Time 0.021 seconds

RESPONSE OF OSTEOBLASI-LIKE CELLS ON TITANIUM SURFACE TREATMENT

  • Roh Hyun-Ki;Heo Seong-Joo;Chang Ik-Tae;Koak Jai-Young;Han Jong-Hyun;Kim Yong-Sik;Yim Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.6
    • /
    • pp.699-713
    • /
    • 2003
  • Statement of problem. Titanium is the most important material for biomedical and dental implants because of their high corrosion resistance and good biocompatibility. These beneficial properties are due to a protective passive oxide film that spontaneously forms on the surface. Purpose. The purpose of this study was to evaluate the responses of osteoblast-like cells on different surface treatments on Ti discs. Material and Methods. Group 1 represented the machined surface with no treatment. Group 2 surfaces were sandblasted with $50{\mu}m\;Al_2O_3$ under $5kgf/cm^2$ of pressure. Groups 3 and 4 were sandblasted under the same conditions. The samples were treated on a titanium oxide surface with reactive sputter depositioning and thermal oxidation at $600^{\circ}C$ (Group 3) and $800^{\circ}C$ (Group 4) for one hour in an oxygen environment. The chemical composition and microtopography were analyzed by XRD, XPS, SEM and optical interferometer. The stability of $TiO_2$ layer was studied by petentiodynamic curve. To evaluate cell response, osteoblast extracted from femoral bone marrow of young adult rat were cultured for cell attachment, proliferation and morphology on each titanium discs. Results and Conclusion. The results were as follows : 1. Surface roughness values were, from the lowest to the highest, machined group, $800^{\circ}C$ thermal oxidation group, $600^{\circ}C$ thermal oxidation group and blasted group. The Ra value of blasted group was significantly higher than that of $800^{\circ}C$ thermal oxidation group (P=0.003), which was not different from that of $600^{\circ}C$ thermal oxidation group (P<0.05). 2. The degree of cell attachment was highest in the $600^{\circ}C$ thermal oxidation group after four and eight hours (P<0.05), but after 24 hours, there was no difference among the groups (P>0.05). 3. The level of cell proliferation showed no difference among the groups after one day, three days, and seven days (P>0.05). 4. The morphology and arrangement of the cells varied with surface roughness of the discs.

A STUDY ON THE ADHESION OF A SOFT LINER CONTAINING 4-META TO THE BASE METAL ALLOY AND ITS VISCOELASTIC PROPERTY

  • Park Hyun-Joo;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.6
    • /
    • pp.732-746
    • /
    • 2003
  • Statement of problem. Soft lining materials, also referred to as tissue conditioning materials, tissue heating materials, relining materials, soft liners or tissue conditioners, were first introduced to dentistry by a plastic manufacturer in 1959. Since the introduction of the materials to the dental field, their material properties have been continually improved through the effort of many researchers. Soft lining materials have become widely accepted, particularly by prosthodontists, because of their numerous clinical advantages and ease of manipulation. Unfortunately, few reports have been issued upon the topic of increasing the bond strength between the base metal alloy used in cast denture bases and PMMA soft liner modified with 4-META, nor upon the pattern of debonding and material change in wet environment like a intra oral situation. Purpose. The purposes of this study were comparing the bond strength between base metal alloy used for the cast denture bases and PMMA soft liner modified with 4-META, and describing the pattern of debonding and material property change in wet environment like the intraoral situation. Material and Methods. This study consisted of four experiments: 1. The in vitro measurement of shear bond strength of the adhesive soft liner. 2. The in vitro measurement of shear bond strength of the adhesive soft liner after 2 weeks of aging. 3. A comparison of debonding patterns. 4. An evaluation the Relation time of modified soft liner. The soft liner used in this study was commercially available as Coe-soft (GC America.IL.,USA), which is provided in forms of powder and liquid. This is a PMMA soft liner commonly used in dental clinics. The metal primer used in this study was 4-META containing primer packed in Meta fast denture base resin (Sun Medical Co., Osaka, Japan). The specimens were formed in a single lap joint desist which is useful for evaluating the apparent shear bond strength of adhesively bonded metal plate by tensile loading. Using the $20{\times}20mm$ transparent grid, percent area of adhesive soft liner remaining on the shear area was calculated to classify the debonding patterns. To evaluate the change of the initial flow of the modified adhesive soft liner, the gelation time was measured with an oscillating rheometer (Haake RS150W/ TC50, Haake Co., Germany). It was a stress control and parallel plate type with the diameter of 35mm. Conclusion. Within the conditions and limitations of this study, the following conclusions were drawn as follows. 1. There was significant increase of bond strength in the 5% 4-META, 10% 4-META containing groups and in the primer coated groups versus the control group(P<0.05). 2. After 2 weeks of aging, no significant increase in bond strength was found except for the group containing 10% 4-META (P<0.05). 3. The gelation times of the modified soft liner were 9.3 minutes for the 5% 4-META containing liner and 11.5 minutes for the 10% 4-META liner. 4. The debonding patterns of the 4-META containing group after 2 weeks of aging were similar to those of immediaely after preparation, but the debonding pattern of the primer group showed more adhesive failure after 2 weeks of aging.

A STUDY ON THE CHANGE OF IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS

  • Park Chan-Jin;Kim Yung-Soo;Kim Chang-Whe;Cho Lee-Ra;Yi Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.271-287
    • /
    • 2003
  • Statement of problem: Resonance frequency analysis (RFA) has been increasingly served as a non-invasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized baseline data using RFA. Purpose: This study was performed to evaluate RFA value changes in two stage surgery group and one stage surgery group in patients. Material and method: Forty-seven mandibles in consecutively implant installed patients were selected for this study and 141 fixtures were installed. Ninety-three fixtures were double threaded, machined surface design ($Br{\aa}anemark^{(R)}$ MK III, Nobel Biocare AB, Goteborg, Sweden) and 48 fixtures were root form, threaded, HA-coated surface one ($Replace^{TM}$, Steri-Oss/Nobel Biocare AB, USA). Among those, each 10 fixture was installed in one stage group patients. ISQ values were measured using $Osstell^{TM}$ (Integration Diagnostics Ltd. Sweden) during fixture installation, at healing abutment connection and in the loading period for two stage surgery group patients and during at each 4, 6, 8, 10, 12week and in the loading phase for one stage surgery group patients and evaluated the changes according to the time and fixture type. Results: In two stage surgery group, mean and SO of ISQ values of machined surface implants were $76.85{\pm}3.74,\;75.76{\pm}5.04,\;75.73{\pm}4.41$ and those of HA-coated surface implant were $75.05{\pm}6.23,\;77.58{\pm}5.23,\;78.32{\pm}4.29$ during fixtures installation, at healing abutment connection and in the loading period, respectively. In one-stage surgery group, the ISQ values of machined surface and HA-coated surface implants decreased until 4 or 6 week and maintained at plateau for 1-3 week and increased to the loading period. Conclusions: Machined and HA-coated surface implants showed minimal ISQ changes with time if they were installed at the sites showing at least intact cortical plate and good bone qualities. And HA-coated implants had a tendency to show somewhat increased ISQ values with time.

COMPARISON OF MECHANICAL PROPERTIES OF VARIOUS POST AND CORE MATERIALS

  • Ahn Seung-Geun;Sorensen John A.
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.288-299
    • /
    • 2003
  • Statement of problem: Many kinds of post and core systems are in the market, but there are no clear selection criteria for them. Purpose: The purpose of this study was to compare the flexural strength and modulus of elasticity of core materials, and measure the bending strength of post systems made of a variety of materials. Material and Methods: The flexural strength and elastic modulus of thirteen kinds core buildup materials were measured on beams of specimens of $2.0{\times}2.0{\times}24{\pm}0.1mm$. Ten specimens per group were fabricated and loaded on an lnstron testing machine at a crosshead speed of 0.25mm/min. A test span of 20 mm was used. The failure loads were recorded and flexural strength calculated with the measured dimensions. The elastic modulus was calculated from the slopes of the linear portions of the stress-stram graphs. Also nine kinds commercially available prefabricated posts made of various materials with similar nominal diameters, approximately 1.25mm, were loaded in a three-point bend test until plastic deformation or failure occurred. Ten posts per group were tested and the obtained data were anaylzed with analysis of variance and compared with the Tukey multiple comparison tests. Results: Clearfil Photo Core and Luxacore had flexural strengths approaching amalgam, but its modulus of elasticity was only about 15% of that of amalgam. The strengths of the glass ionomer and resin modified glass ionomer were very low. The heat pressed glass ceramic core had a high elastic modulus but a relatively low flexural strength approximating that of the lower strength composite resin core materials. The stainless steel, zirconia and carbon fiber post exhibited high bending strengths. The glass fiber posts displayed strengths that were approximately half of the higher strength posts. Conclusion: When moderate amounts of coronal tooth structure are to be replaced by a post and core on an anterior tooth, a prefabricated post and high strength, high elastic modulus core may be suitable. CLINICAL IMPLICATIONS In this study several newly introduced post and core systems demonstrated satisfactory physical properties. However when the higher stress situation exists with only a minimal ferrule extension remaining a cast post and core or zirconia post and pressed core are desirable.

A STUDY ON OSTEOBLAST-LIKE CELL RESPONSES TO SURFACE-MODIFIED TITANIUM

  • Hong Min-Ah;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Su;Lee Jae-Il
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.300-318
    • /
    • 2003
  • Statement of problem: The success of implants depends on intimate and direct contact of implant material on bone tissue and on functional relationship with soft tissue contact. Creation and maintenance of osseointegration depend on the understanding of the tissue's healing, repairing, and remodeling capacity and these capacities rely on cellular behavior. Altering the surface properties can modify cellular responses such as cell adhesion, cell motility, bone deposition, Therefore, various implant surface treatment methods are being developed for the improved bone cell responses. Purpose: The purpose of this study was to evaluate the responses of osteoblast-like cells to surface-modified titanium. Materials and Methods: The experiment was composed of four groups. Group 1 represented the electropolished surface. Group 2 surfaces were machined surface. Group 3 and Group 4 were anodized surfaces. Group 3 had low roughness and Group 4 had high roughness. Physicochemical properties and microstructures of the discs were examined and the responses of osteoblast-like cells to the discs were investigated. The microtopography was observed by SEM. The roughness was measured by three-dimension roughness measuring system. The microstructure was analyzed by XRD, AES. To evaluate cell responses to modified titanium surfaces, osteoblasts isolated from calvaria of neonatal rat were cultured. Cell count, morphology, total protein measurement and alkaline phosphatase activities of the cultures were examined. Results and Conclusion: The results were as follows 1. The four groups showed specific microtopography respectively. Anodized group showed grain structure with micropores. 2. Surface roughness values were, from the lowest to the highest, electropolished group, machined group, low roughness anodized group, and high roughness anodized group. 3. Highly roughened anodized group was found to have increased surface oxide thickness and surface crystallinity. 4. The morphology of cells, flattened or spherical, were different from each other. In the electropolished group and machined group, the cells were almost flattened. In two anodized groups, some cells were spherical and other cells were flattened. And the 14 day culture cells of all of the groups were nearly flattened due to confluency. 5. The number of attached cells was highest in low roughness anodized group. And the machined group had significantly lower cell count than any other groups(P<.05). 6. Total protein contents showed no difference among groups. 7. The level of alkaline phosphatase activities was higher in the anodized groups than electropolished and machined groups(P<.05).

A SHEAR BOND STRENGTH OF RESIN CEMENT BONDED TO HUMAN UNCUT ENAMEL, CUT ENAMEL, AND DENTIN IN VITRO

  • Lee Jong-Yeop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.319-324
    • /
    • 2003
  • Statement of problem. Adhesives in dentistry playa major role in the success of restorative treatments. In the treatment of all ceramic restoration it is needed to find the adequate bond strength between enamel and dentin. Purpose. The purpose of this study was to evaluate shear bond strength of resin cement bonded to extracted human uncut enamel, cut enamel, and dentin in vitro. Material and methods. Ten freshly extracted anterior teeth without any previous restorative treatments were chosen. The extracted teeth were embedded in PMMA cold acrylic in the shape of a cylinder, 25 mm in diameter by 25 mm in height. The bonding system used was as follow: Uni-Etch (32% phosphoric acid), One-Step adhesive, Duolink resin cement. The specimens were acid etched and rinsed with water. Two layers of One-Step adhesive were coated with a disposable brush on the uncut enamel. VIP curing light at $500mV/cm^2$ was used to cure the adhesive. For cut enamel shear bond test, the specimen used for uncut enamel was further reduced approximately $0.3{\sim}0.5mm$ using a laminate preparation diamond bur (0.3 mm in depth). The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit SiC paper and cleaned with distilled water. The bonding procedure on the cut enamel was same as uncut enamel bonding procedure. For dentin bonding test, the specimen used for cut enamel was further reduced approximately $0.5mm{\sim}1.0mm$ using a laminate preparation diamond bur (0.5 mm in depth of diamond cutting). The amount of reduction was evaluated with the silicone mold. The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit silicon carbon paper and cleaned in distilled water. The bonding procedure on the dentin was same as uncut enamel bonding procedure. All samples were mounted and secured on the Ultradent shear bond test sample holder, and Ultradent restricted shear bond testing device was used with Universal Instron machine until fracture. Analysis of variance (ANOVA) test was performed comparing the result at P<0.05. Multiple comparison (Tukey) was used to compare each groups. Result. The result showed that the mean value in shear bond strength of resin cement bonded to uncut enamel, cut enamel and dentin were 27.04 Mpa, 30.25 Mpa and 26.39 Mpa with respect. Conclusion. Within the limitation of this study, the mean value of the shear bond strength of cut enamel was higher than those of uncut enamel or dentin. However there existed no statistical differences between three different human dentition substrates due to increased adhesive characteristics.

THE EFFECT OF THE BIORESORBABLE COLLAGEN MEMBRANE ON THE REGENERATION OF BONE DEFECT BY USING THE MIXTURE OF AUTOGRAFT AND XENOGRAFT BONE

  • Lee Jung-Min;Kim Yung-Soo;Kim Chang-Whe;Han Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.325-341
    • /
    • 2003
  • Statement of problem: In cases where bony defects were present, guided bone regenerations have been performed to aid the placement of implants. Nowadays, the accepted concept is to isolate bone from soft tissue by using barrier membranes to allow room for generation of new bone. Nonresorbable membranes have been used extensively since the 1980's. However, this material has exhibited major shortcomings. To overcome these faults, efforts were made to develop resorbable membranes. Guided bone regenerations utilizing resorbable membranes were tried by a number of clinicians. $Bio-Gide^{(R)}$ is such a bioresorbable collagen that is easy to use and has shown fine clinical results. Purpose: The aim of this study was to evaluate the histological results of guided bone regenerations performed using resorbable collagen membrane($Bio-Gide^{(R)}$) with autogenous bone, bovine drived xenograft and combination of the two. Surface morphology and chemical composition was analyzed to understand the physical and chemical characteristics of bioresorbable collagen membrane and their effects on guided bone regeneration. Material and methods: Bioresorbable collagen membrane ($Bio-Gide^{(R)}$), Xenograft Bone(Bio-Oss), Two healthy, adult mongrel dogs were used. Results : 1. Bioresorbable collagen membrane is pure collagen containing large amounts of Glysine, Alanine, Proline and Hydroxyproline. 2. Bioresorbable collagen membrane is a membrane with collagen fibers arranged more loosely and porously compared to the inner surface of canine mucosa: This allows for easier attachment by bone-forming cells. Blood can seep into these spaces between fibers and form clots that help stabilize the membrane. The result is improved healing. 3. Bioresorbable collagen membrane has a bilayered structure: The side to come in contact with soft tissue is smooth and compact. This prevents soft tissue penetration into bony defects. As the side in contact with bone is rough and porous, it serves as a stabilizing structure for bone regeneration by allowing attachment of bone-forming cells. 4. Regardless of whether a membrane had been used or not, the group with autogenous bone and $Bio-Oss^{(R)}$ filling showed the greatest amount of bone fill inside a hole, followed by the group with autogenous bone filling, the group with blood and the group with $Bio-Oss^{(R)}$ Filling in order. 5. When a membrane was inserted, regardless of the type of bone substitute used, a lesser amount of resorption occurred compared to when a membrane was not inserted. 6. The border between bone substitute and surrounding bone was the most indistinct with the group with autogenous bone filling, followed by the group with autogenous bone and $Bio-Oss^{(R)}$ filling, the group with blood, and the group with $Bio-Oss^{(R)}$ filling. 7. Three months after surgery, $Bio-Gide^{(R)}$ and $Bio-Oss^{(R)}$ were distinguishable. Conclusion: The best results were obtained with the group with autogenous bone and $Bio-Oss^{(R)}$ filling used in conjunction with a membrane.

COLOR STABILITY OF CEROMERS IN THREE FOOD COLORANTS (식용색소에 의한 CEROMER 수복물의 색안정성)

  • Jeong Yu-Jin;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.136-147
    • /
    • 2003
  • Statement of problem : Ceramic and composite resin have been used to fulfill the demand for esthetic prosthesis. However, ceramic is easy to break and wears off the opposite natural teeth. Conventional composite resin also has low abrasive resistance and color stability. Ceramic Optimized Polymer (ceromer) was developed in mid-1990s to overcome the shortfalls of ceramic and composite resin. Ceromer has similar abrasiveness with the natural tooth and has relatively high strength. Color stability affects esthetics and long-term prognosis of the prosthesis. Purpose The purpose of this study was to compare color stability of ceromers(2 types : $Artglass^{(R)}$. $Targis^{(R)}$) with ceramics ($Vintage^{(R)}$-polishing, $Vintage^{(R)}$-glazing). Material and Method : The color difference(${\Delta}E^*$) was measured by spectrophotometer with different immersion time. Twenty disks, 3mm in thickness and 10mm in diameter, were fabricated for each specimen in shade A2(Vita Lumin shade guide), Specimens (5 samples in each group) were immersed in the food colorants (Red no.3. Yellow no.4, Blue no.1, Distilled water) for 24 hours, 48 hours and 72 hours respectively. $L^*,\;a^*$ and $b^*$ value were measured with spectrophotometer (CM 503i : Minolta Co., Japan) and mean ${\Delta}E^*$ value was calculated for statistical analysis Results : The results of this study were obtained as follows. 1. The ${\Delta}E^*$ values of all test samples increased with the time of immersion. 2. The ${\Delta}E^*$ values of all materials increased in order of Distilled Water, Yellow no.4, Blue no.1 and fed no.3. There was significant difference between Red no.3 and the other food colorants(p<0.05). 3. The ${\Delta}E^*$ values increased in order of $Vintage^{(R)}$-glazing, $Vintage^{(R)}$-polishing. $Artglass^{(R)}$ and $Targis^{(R)}$. There was significant difference between $Vintage^{(R)}$-glazing and the other materials (p<0.05). Conclusion : By means of the above results, immersion time was found to be a critical factor for color stability of ceromer. For the long-term color stability of prosthesis it is recommended patients having ceromer prosthesis ($Artglass^{(R)},\;Targis^{(R)}$) to reduce the habitual intake of Red no.3 colorants con taming foods.

COMPARISON OF BITE FORCE WITH DENTAL PRESCALE AND UNILATERAL BITE FORCE RECORDER IN HEALTHY SUBJECTS (Dental Prescale과 편측 교합력 측정기를 이용한 정상성인의 교합력 비교)

  • Kwon Ho-Keun;Yoo Ja-Hea;Kwon Young-Sook;Kim Baek-Il
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.103-111
    • /
    • 2006
  • Statement of problem: The previous unilateral bite force recorder has several limitations for taking long time for measuring and causing discomfort to subjects. Because of these reasons, it could not use widely for epidemiological researches. However, 'Dental Prescale System' which is new equipment for measuring bite force, is more convenient for measuring bite force than previous unilateral recorder. Purpose: The purpose of this study was to compare a new technique(Dental Prescale System) using pressure sensitive foils for recording of maximal jaw closing force with conventional measurement using unilateral bite force recorder Material and method: This studies included 22 healthy dental students in college of dentistry Yonsei university in Rep of Korea. Mean age was 23.9 years. All subjects had continuous dental arches and no significant malocclusion or signs from the teeth and craniomandibular system. The Dental Prescale System (Fuji Film, Tokyo, Japan) consists of a horseshoe-shaped pressure sensitive sheet (50H, R type) and a computerized scanning system.(FPD705) We also used unilateral bite force recorder(Denbotics Co. Seoul, Rep.Korea) for comparing with Dental Prescale. Results and conclusion: The total bite force recorded with Dental Prescale System (1423 N) was systematically higher than that recorded by unilateral bite force recorder. (256 N) However, the maximum bite force values measured in the two ways were significantly correlated (r=0.46, p<0.05). The Dental Prescale bite force calculated for first molar (208 N) was lower than that recorded by unilateral bite force recorder. (256 N) The two values were also very significantly correlated. (r=0.66. p<0.001) There were significantly different in bite force between two measurement methods. The reasons were first, unilateral bite force recorder measured only the bite force of a part of teeth, and Dental Prescale measured the total teeth force. Second, in measurement, a difference in muscle contraction appeared by an extent of mouth-opening. Third, unilateral bite force recorder has the reducing effect of the bite force by protective tape. Fourth, Dental Prescale has limitations during the computer scanning procedure. Therefore, Dental Prescale System is considered to be a very promising alternative to be conventional bite force recording methods.

Effect of post-bleaching time intervals on resin in dentin bonding strength (미백 후 유예 기간에 따른 상아질과 레진의 결합 강도의 변화)

  • Song, Shin-Jae;Kim, Sun-Jong;Ro, Yong-Seon;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.174-181
    • /
    • 2009
  • Statement of problem: There is a reduction of dentin bonding strength when the bonding procedure is carried out immediately after bleaching with peroxides. Purpose: The aim of this study is to evaluate a proper time interval for in-office bleaching technique using 35% hydrogen peroxide. Material and methods: Fifty extracted non-caries human third molars were used in this study. Buccal enamel of each tooth was removed and polished by 600 grits silicone carbide paper. They were randomly divided into five groups and bleached 35% hydrogen peroxide except control group. All groups were bonded with Single Bond/Z 350 after each time intervals ; Group-A: control, no bleaching treatment. Group-B: resin bonding immediately after bleaching. Group-C: resin bonding 1day after bleaching. Group-D: resin bonding 2 days after bleaching. Group-E: resin bonding 7days after bleaching. Shear bond strengths were measured with a cross-head speed of 1.0 mm/min using an Instron machine. The data of results were statistically analyzed by analysis of variance(ANOVA) and Tukey multiple comparison test.(P=.05) Results: There were significant decreases in mean shear strength in immediately bonding group after bleaching. The reduction of bond strengths was 78% compared with the group of no bleaching treatment. Group C showed the recovery of 51%, and Group D showed recovery of 63%. Both of them have no statistical difference with non-bleaching group. Group E showed no statistical difference with no bleaching treatment group. Conclusion: Dentin bonding strength is significantly reduced when bonding is performed immediately after bleaching for in-office bleaching regimens using 35% hydrogen peroxide, and increases as time goes by. One week of elapsed time between bleaching and resin bonding significantly increases bonding strengths for the in-office bleaching technique.