• Title/Summary/Keyword: Probe unit

Search Result 138, Processing Time 0.029 seconds

Measurement of the Volumetric Thermal Errors for CNC Machining Center Using the Star-type-styluses Tough Probe

  • Lee, Jae-Jong;Yang, Min-Yang
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.111-117
    • /
    • 2000
  • One of the major limitations of productivity and quality in metal cutting is the machining accuracy of machine tools. The machining accuracy is affected by geometric errors, thermally-induced errors, and the deterioration of the machine tools. Geometric and thermal errors of machine tools should be measured and compensated to manufacture high quality products. In metal cutting, the machining accuracy is more affected by thermal errors than by geometric errors. This paper models the thermal errors for error analysis and develops an on-the-machine measurement system by which the volumetric errors are measured and compensated. The thermal error is modeled by means of angularity errors of a column and thermal drift error of the spindle unit which are measured by the touch probe unit with a star type styluses and a designed spherical ball artifact (SBA). Experiments show that the developed system provides a high measuring accuracy, with repeatability of $\pm$2$\mu\textrm{m}$ in X, Y and Z directions. It is believed that the developed measurement system can be also applied to the machine tools with CNC controller. In addition, machining accuracy and product quality can be also improved by using the developed measurement system when the spherical ball artifact is mounted on a modular fixture.

  • PDF

Scanning Probe Microscopy Study on the Degradation of Optical Recoding Disks by Environmental Factors (광디스크의 노화에 관한 주사 탐침 현미경 연구)

  • Yoon, Man-Young;Shin, Hyun-Chang
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.29 no.3
    • /
    • pp.97-104
    • /
    • 2011
  • The storing ability of information of optical disks directly depends on the physical property of recording unit cells. It means that the degradation of optical disks ultimately causes the loss of the physical and chemical properties of recording unit cells and leads also information, too. We investigated the degradation and life time of optical disks which tell us the longevity of the preservation of information. Optical disks were aged using the accelerated aging system and studied by optical reflectivity spectroscopy and atomic force microscopy(AFM), and the preservation environment of electronic media in National central library of Korea also were analysed. Results show that the double reflective coated optical disks have good preservation of recording information but revealed some deformation of dye area in the AFM images. It means that we should include the mechanical and chemical degradation of the optical disks in the life time expectation evaluation.

LCD Cell Aging Tester

  • Son, Hyuk;Baek, Sung-Sik;Oh, Hyeong-Geun;Choi, Byoung-Deog
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1383-1385
    • /
    • 2009
  • This paper suggests that testing method and equipment structure to detect potential failures of LCD cells. LCD Cell Aging Tester is the unique process to detect failures related with ASG circuits. This system consists of four components that is Aging chamber, work table, probe contact unit, and pattern generator. The key factor of the concept is temperature aging and HVS driving. Complicated combination of test parameters including voltage, temperature and frequency provided practical burn-in conditions eligible for prediction of mass production.

  • PDF

A Study on the Performance of Soot Probe of Diesel Vehicles using Free Acceleration Mode Method (무부하급가속검사방법을 이용한 디젤자동차의 매연프로브 성능에 관한 연구)

  • Kim, Jae-Yeol;Chae, Il-Seok;Oh, Hoo-suk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.9
    • /
    • pp.40-46
    • /
    • 2020
  • Inspection of vehicle systems is regularly performed by the state to ensure the emission status and the safety of vehicles. Thereby, the safety and quality of life can be improved by reducing green-house gases and fine dust, which are the main causes of vehicle defects and air pollution. This study analyzed the soot measuring probes used in the free acceleration mode method, at no-load condition, looking at the efficiency of a probe to measure soot emissions from diesel vehicles. In this study, a technique that can improve the inhalation efficiency of the probe over the (a) probes and the improved (b) probes was applied to probes (c). Probe (c) involves a structure designed close to the center of the circumference of the exhaust pipe. Results showed that the suction efficiency was improved by adding a variable center unit.

The Optical Design of Probe-type Microscope Objective for Intravital Laser Scanning CARS Microendoscopy

  • Rim, Cheon-Seog
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.431-437
    • /
    • 2010
  • A stack of gradient-index (GRIN) rod lenses cannot be used for coherent anti-Stokes Raman scattering (CARS) microendoscopy for insertion to internal organs through a surgical keyhole with minimal invasiveness. That's because GRIN lens has large amount of inherent chromatic aberrations in spite of absolutely requiring a common focus for pump and Stokes beam with each frequency of ${\omega}_p$ and ${\omega}_S$. For this endoscopic purpose, we need to develop a long slender probe-type objective, namely probe-type microscope objective (PMO). In this paper, we introduce the structure, the working principle, and the design techniques of PMO which is composed of a probe-type lens module (PLM) and an adaptor lens module (ALM). PLM is first designed for a long slender type and ALM is successively designed by using several design parameters from PLM for eliminating optical discords between scanning unit and PLM. A combined module is optimized again to eliminate some coupling disparities between PLM and ALM for the best PMO. As a result, we can obtain a long slender PMO with perfectly diffraction-limited performance for pump beam of 817 nm and Stokes beam of 1064 nm.

The Theory and Application of Diffusive Gradient in Thin Film Probe for the Evaluation of Concentration and Bioavailability of Inorganic Contaminants in Aquatic Environments (박막분산탐침(diffusive gradient in thin film probe)의 수중 생물학적 이용가능한 중금속 측정 적용)

  • Hong, Yongseok
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.691-702
    • /
    • 2013
  • This review paper summarizes the theory, application, and potential drawbacks of diffusive gradient in thin film (DGT) probe which is a widely used in-situ passive sampling technique for monitoring inorganic contaminants in aquatic environments. The DGT probe employs a series of layers including a filter membrane, a diffusive hydrogel, and an ionic exchange resin gel in a plastic unit. The filter side is exposed to an aquatic environment after which dissolved inorganic contaminants, such as heavy metals and nuclides, diffuse through the hydrogel and are accumulated in the resin gel. After retrieval, the contaminants in the resin gel are extracted by strong acid or base and the concentrations are determined by analytical instruments. Then aqueous concentrations of the inorganic contaminants can be estimated from a mathematical equation. The DGT has also been used to monitor nutrients, such as ${PO_4}^{3-}$, in lakes, streams, and estuaries, which might be helpful in assessing eutrophic potential in aquatic environments. DGT is a robust in-situ passive sampling techniques for investigating bioavailability, toxicity, and speciation of inorganic contaminants in aquatic environments, and can be an effective monitoring tool for risk assessment.

Dimethylnitrosamine-Induced Reduction in the Level of Poly-ADP-Ribosylation of Histone Proteins of Blood Lymphocytes - a Sensitive and Reliable Biomarker for Early Detection of Cancer

  • Kma, Lakhan;Sharan, Rajeshwar Nath
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.15
    • /
    • pp.6429-6436
    • /
    • 2014
  • Poly-ADP-ribosylation (PAR) is a post-translational modification of mainly chromosomal proteins. It is known to be strongly involved in several molecular events, including nucleosome-remodelling and carcinogenesis. In this investigation, it was attempted to evaluate PAR level as a reliable biomarker for early detection of cancer in blood lymphocyte histones. PAR of isolated histone proteins was monitored in normal and dimethylnitrosamine (DMN)-exposed mice tissues using a novel ELISA-based immuno-probe assay developed in our laboratory. An inverse relationship was found between the level of PAR and period of DMN exposure in various histone proteins of blood lymphocytes and spleen cells. With the increase in the DMN exposure period, there was reduction in the PAR level of individual histones in both cases. It was also observed that the decrease in the level of PAR of histones resulted in progressive relaxation of genomic DNA, perhaps triggering activation of genes that are involved in initiation of transformation. The observed effect of carcinogen on the PAR of blood lymphocyte histones provided us with a handy tool for monitoring biochemical or physiological status of individuals exposed to carcinogens without obtaining biopsies of cancerous tissues, which involves several medical and ethical issues. Obtaining blood from any patient and separating blood lymphocytes are routine medical practices involving virtually no medical intervention, post-procedure medical care or trauma to a patient. Moreover, the immuno-probe assay is very simple, sensitive, reliable and cost-effective. Therefore, combined with the ease of preparation of blood lymphocytes and the simplicity of the technique, immuno-probe assay of PAR has the potential to be applied for mass screening of cancer. It appears to be a promising step in the ultimate goal of making cancer detection simple, sensitive and reliable in the near future.

An Algorithm for Finding Surface Atoms of a Protein Molecule Based on Voxel Map Representation (복셀 맵을 이용한 단백질 표면 원자의 발견 알고리즘)

  • Kim, Byung-Joo;Kim, Ku-Jin;Seong, Joon-Kyung
    • The KIPS Transactions:PartA
    • /
    • v.19A no.2
    • /
    • pp.73-76
    • /
    • 2012
  • In this paper, we propose an efficient method to extract surface atoms from a protein molecule. Surface atoms are defined as a set of atoms who can contact given probe solvent $P$, where $P$ does not collide with the molecule. The atoms contained in the molecule are represented as a set of spheres with van der Waals radii. The probe solvent also is represented as a sphere. We propose a method to extract the surface atoms by computing the offset surface of the molecule with respect to the radius of $P$. For efficient computation of the offset surface of a molecule, a voxel map is constructed for the offset surfaces of the spheres. Based on GPU (graphic processor unit) acceleration, a data parallel algorithm is used to extract the surface atoms in 42.87 milliseconds for the molecule containing up to 6,412 atoms.