• 제목/요약/키워드: Probe forces

Search Result 47, Processing Time 0.024 seconds

A Study on Improvement of Accuracy using Geometry Information in Reverse Engineering of Injection Molding Parts (사출성형품의 역공학에서 Geometry 정보를 이용한 정밀도 향상에 관한 연구)

  • Kim, Yeon-Sul;Lee, Hui-Gwan;Hwang, Geum-Jong;Gong, Yeong-Sik;Yang, Gyun-Ui
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.10
    • /
    • pp.99-106
    • /
    • 2002
  • This paper proposes an error compensation method that improves accuracy with geometry information of injection molding parts. Geometric information can give an improved accuracy in reverse engineering. Measuring data can not lead to get accurate geometric model, including errors of physical parts and measuring machines. Measuring data include errors which can be classified into two types. One is molding error in product, the other is measuring error. Measuring error includes optical error of laser scanner, deformation by probe forces of CMM and machine error. It is important to compensate these in reverse engineering. Least square method (LSM) provides the cloud data with a geometry compensation, improving accuracy of geometry. Also, the functional shape of a part and design concept can be reconstructed by error compensation using geometry information.

Micropositioning of a Linear Motion Table with Magnetic Bearing Suspension (자기 베어링으로 지지 되는 직선운동 테이블의 초정밀 위치제어에 관한 연구)

  • 김의석;안형준;장인배;한동철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.466-469
    • /
    • 1995
  • This paper presents a design and performance of the 6 D.O.F linear motion table with a magnetic bearing suspension. The linear positioning of the table with a 150mm stroke is driven by a brushless DC Linear motor and the other attitudes of the stage are controlled by the analog PD controller with magnetic bearing actuators. Each magnetic bearing unit which consists of 3 electromagnets, 3 capacitance probes and 3 backup bearings affords controlled forces by detecting the air gap between the probes and guideways. An integral type capacitance probe amplifier is equipped on the upper plate of the table so that the probe line to the probe amplifier can be shorter therefore the problems due to the stray capacitance and noise can be reduced. Form the pitch-yaw errormeasured by the autocollimator, the vertical and horizont straightness errors of the table are derived that they are maintained below 1.mu. m over 100mm stroke. The positioning accuracy of the linear motion is maintained below 2 .mu. m and the repeatability error is below 1 .mu. m

  • PDF

Spectrofluorometric Study of the Interaction of Coumarin Derivatives with Bovine Serum Albumin

  • Kamat, B.P.;Seetharamappa, J.;Kovala-Demertzi, D.
    • Journal of Photoscience
    • /
    • v.11 no.32
    • /
    • pp.65-69
    • /
    • 2004
  • The mechanism of interaction of four coumarin derivatives (CDS) with bovine serum albumin (BSA) was studied using spectrofluorometric technique. It was found that the coumarin ring common to all CDS makes major contribution to interaction. Binding affinities could be related to parachor values of CDS. Stem-Volmer plots indicated the presence of static component in the quenching mechanism. Results also showed that both tryptophan residues of protein are accessible to CDS. The high magnitude of rate constant of quenching indicated that the process of energy transfer occurs by intermolecular interaction forces and thus CDS binding site is in close proximity to tryptophan residues of BSA. Binding studies in the presence of the hydrophobic probe, 8-anilino-l-naphthalein-sulfonic acid showed that there is hydrophobic interaction between CDS and the probe and they do not share common sites in BSA. Thermodynamic parameters obtained from data at different temperatures showed that the binding of CDS to BSA involve hydrophobic bonds predominantly. The effects of various metal ions on the binding of CDS with BSA were also investigated.

  • PDF

Design & development of a device for thin-film evaluation using a two-component loadcell (2축 로드셀을 이용한 박막평가장치의 설계 및 개발)

  • Lee, Jeong-Il;Kim, Jong-Ho;Park, Yon-Kyu;Oh, Hee-Geun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1448-1452
    • /
    • 2003
  • A scratch tester was developed to evaluate the adhesive strength at interface between thin-film and substrate(silicon wafer). Under force control, the scratch tester can measure the normal and the tangential forces simultaneously as the probe tip of the equipment approaches to the interface between thin-film and substrate of wafer. The capacity of each component of force sensor is 0.1 N ${\sim}$ 100 N. In addition, the tester can detect the signal of elastic wave from AE sensor(frequency range of 900 kHz) attached to the probe tip and evaluate the bonding strength of interface. Using the developed scratch tester, the feasibility test was performed to evaluate the adhesive strength of thin-film.

  • PDF

Microscopic Surface Dynamics Studied by Scanning Probe Microscopy

  • Gwon, Gi-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.111-111
    • /
    • 2011
  • Arrangement of individual atoms and molecules with atomic precision and understanding the resulting properties at the molecular level are ultimate goals of chemistry, biology, and materials science. For the past three decades, scanning probe microscopy has made strides towards these goals through the direct observation of individual atoms and molecules, enabling the discovery of new and unexpected phenomena. This talk will discuss the origin of forces governing motion of small organic molecules and their extended self-assembly into two-dimensional surface structures by direct observation of individual molecules using scanning tunneling microscopy (STM). In addition, atomic force microscopy (AFM) is utilized for the investigation of fundamental mechanisms of bone mineral dissolution by examining atomically well characterized simulated bone minerals under aqueous solution environments.

  • PDF

Effect of Contact Conditions on the Micro-adhesion Characteristics using SPM (SPM을 이용한 접촉조건 변화에 따른 미소응착 특성 연구)

  • 윤의성;박지현;양승호;공호성
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.18-22
    • /
    • 2000
  • An experimental study was carried out to investigate the effect of nano-contact condition on the nano-adhesion phenomena. SPM(scanning probe microscope) tips with different radius of curvature were fabricated by a series of masking and etching processes. DLC(diamond-like carbon) and W-DLC (tungsten-incorporated diamond-like carbon) were coated on (100) silicon wafer by PACVD(plasma assisted chemical vapor deposition). Pull-off forces of Pure Si-wafer, DLC and W-DLC were measured with SPM(scanning probe microscope). Also, the same series of tests were carried out with the tips with different radius of curvature. Results showed that DLC and W-DLC showed much lower pull-off force than Si-wafer and Pull-off force increased with the tip radius.

  • PDF

Spectroscopic Studies on the Interaction of N-alkyl Phenothiazines with Bovine Serum Albumin

  • Seetharamappa, J.;Shaikh, S.M.T;Kamat, B.P.
    • Journal of Photoscience
    • /
    • v.12 no.1
    • /
    • pp.25-32
    • /
    • 2005
  • Binding of N-Alkyl phenothiazines (NAP) to bovine serum albumin (BSA) was studied by spectroscopic methods.It was found that the phenothiazine ring common to all drugs makes major contribution to interaction. However, the nature of alkylamino group at position 10 influences the protein binding significantly. Stern-Volmer plots indicated the presence of static component in the quenching mechanism. The high magnitude of rate constant of quenching indicated that the process of energy transfer occurs by intermolecular interaction and thus the drug-binding site is in close proximity to tryptophan residues of BSA. Binding studies in presence of hydrophobic probe, 8-anilino-1-naphthalein-sulphonic acid showed that there is hydrophobic interaction between drug and the probe and they do not share common sites in BSA. Thermodynamic parameters obtained from data at different temperatures showed that the binding of NAP to BSA predominantly involve hydrophobic forces. The effects of some cations and anions common ions were investigated on NAP-BSA interactions. The CD spectrum of BSA in presence of drug showedthat binding of drug leads to change in the helicity of the protein.

  • PDF

A Comparison of Rheological Measurement Methods of Instant Cooked Rice by a Texture Analyzer (텍스처 분석기를 활용한 즉석밥 물성 측정 방법의 상호 비교)

  • Kim, Heesu;Oh, Im Kyung;Yang, Seonkyeong;Lee, Suyong
    • Food Engineering Progress
    • /
    • v.22 no.4
    • /
    • pp.381-385
    • /
    • 2018
  • Various rheological methods to measure the hardness of instant cooked rice by a texture analyzer were investigated and compared. Specifically, instant white rice samples with a wide range of hardness were subjected to four different rheological tests with disk, cylinder, rod, and cone probe whose results were inter-correlated. All the measurements demonstrated that the hardness of instant rice was reduced with increasing moisture content and showed negatively linear relationships. Out of the four tests applied in this study, the highest coefficient of correlation ($R^2=0.9268$) was observed distinctly in the cone probe test, where both compressive and shear forces can be applied to deform individual rice grains. However, the cylinder probe test had the lowest coefficient of correlation ($R^2=0.7247$) because it may be ineffective in causing direct deformation of individual rice grains. Furthermore, when the hardness values (N) were converted to stress (Pa), highly linear correlations ($R^2{\approx}0.99$) were observed between the tests with similar probe geometry and force application.

Friction and Pull-off Forces on Submicron-Size Asperity Measured in High Vacuum

  • Ando, Y.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.57-58
    • /
    • 2002
  • Asperity arrays and Independent asperities were fabricated on a silicon plate. Then pull-off and friction forces were measured on each asperity pattern by using AFM (atomic force microscope) in humid air and high vacuum of $2{\times}10^{-5}$ Pa. The probe of AFM cantilever has a flat square of about $1\;{\mu}m^2$ on its tip. The results showed that the pull-off force was proportional to the curvature radius of asperity peak in each ambient condition. The friction force was proportional to the pull-off force and was slightly higher in the humid air than in the high vacuum.

  • PDF

Two-dimensional Surface Structures of Arenthiols Studied by STM

  • Gwon, Gi-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.89-89
    • /
    • 2012
  • Arrangement of individual atoms and molecules with atomic precision and understanding the resulting properties at the molecular level are ultimate goals of chemistry, biology, and materials science. For the past three decades, scanning probe microscopy has made strides towards these goals through the direct observation of individual atoms and molecules, enabling the discovery of new and unexpected phenomena. This talk will discuss the origin of forces governing motion of small organic molecules and their extended self-assembly into two-dimensional surface structures by direct observation of individual molecules using scanning tunneling microscopy (STM).

  • PDF