• 제목/요약/키워드: Probe current

검색결과 568건 처리시간 0.03초

LED 검사장비용 탐침의 특성 규명 (Characterization of Probe Pin for LED Inspection System)

  • 심희수;김선경
    • 한국생산제조학회지
    • /
    • 제24권6호
    • /
    • pp.647-652
    • /
    • 2015
  • A probe pin is a key component of LED inspection equipment. The probe pin makes contact with the LED electrodes and supplies an electric current. Because the mechanical and electrical homogeneity of the probe surface affects the service life and reliability, its characterization is essential. For this study, the hardness was measured using a micro-Vickers hardness test. Moreover, the thicknesses of the plating at different locations and the elemental compositions were examined using an FE-SEM. The uniformity of the plating was found to be acceptable because palladium was detected consistently throughout the tested domain. In addition, the hardness of the surface was determined to be higher than that of the typical palladium range, which is attributed to the use of undercoated nickel.

자기혼합형 LDF 프로브와 혈류 시뮬레이터의 구현 (Implementation of a self-mixing type LDF probe and blood flow simulator)

  • 고한우;김종원
    • 센서학회지
    • /
    • 제8권2호
    • /
    • pp.133-138
    • /
    • 1999
  • In this pager, the authors have implemented a blood flow simulator and a LDF(laser Doppler flowmeter) probe using self-mixing effect of the laser diode. The purpose of the blood flow simulator is to simulate microvascular blood flow in tissue. It consists of melinex film (thickness = $123\;{\mu}m$) which has similar optical characteristics to epidermis and porous polyethylene filter (Vyon, porosity 35%, mean pore size $50\;{\mu}m$, thickness=1 mm) which has similar optical characteristics to dermis. The blood flowmeter probe consists of laser diode(5 mW, 780 nm wavelength), CD lens(focal length 12 mm). current-to-voltage converter, highpass filter, and premplifier. It doesn't need optical fiber, therefore, implementation of the probe is simpler than conventional probe using optical fiber.

  • PDF

A Pivot And Probe Algorithm(PARA) for Network Optimization

  • Moonsig Kang;Kim, Young-Moon
    • 경영과학
    • /
    • 제15권1호
    • /
    • pp.1-12
    • /
    • 1998
  • This paper discusses a new algorithm, the PAPANET (Pivot And Probe Algorithm for NETwork optimization), for solving linear, capacitated linear network flow problem (NPs), PAPANET is a variation and specialization of the Pivot And Probe Algorithm (PAPA) developed by Sethi and Thompson, published in 1983-1984. PAPANET first solves an initial relaxed NP (RNP) with all the nodes from the original problem and a limited set of arcs (possibly all the artificial and slack arcs). From the arcs not considered in the current relaxation, we PROBE to identify candidate arcs that violate the current solution's dual constraints maximally. Candidate arcs are added to the RNP, and this new RNP is solved to optimality. This candidate pricing procedure and pivoting continue until all the candidate arcs price unfavorably and all of the dual constraints corresponding to the other, so-called noncandidate arcs, are satisfied. The implementation of PAPANET requires significantly fewer arcs and less solution CPU time than is required by the standard network simplex method implementation upon which it is based. Computational tests on randomly generated NPs indicate that our PAPANET implementation requires up to 40-50% fewer pivots and 30-40% less solution CPU time than is required by the comparable standard network simplex implementation from which it is derived.

  • PDF

경계요소해석을 이용한 와전류 센서의 특성 해석 (Analyse of characteristic of Eddy current sensor using Boundary Element Method)

  • 윤만식;최덕수;양규창;이향범;박승한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.697-699
    • /
    • 2002
  • In this paper, the characteristics analysis of the eddy current sensor by using boundary element method package is presented. For the boundary element analysis. Faraday, which is the commercial package of the integrated engineering software, is used. To observe the impedance characteristic of the eddy current senor with the sensor position and lift-off, the eddy current testing analysis is performed on the ferromagnetic plate with defect. Considering the skin depth of the ferromagnetic specimen, the 800(Hz) driving source is chosen. The result shows that electro motive force is reduced as the probe moves to near the defect and the lift-off of the probe increases.

  • PDF

이온프로브 장착 점화플러그를 이용한 노크발생 판정 (Knock Detection Using an Ionization Probe Installed Spark Plug)

  • 한성주;이용규;민경덕;김응서
    • 한국자동차공학회논문집
    • /
    • 제8권6호
    • /
    • pp.1-8
    • /
    • 2000
  • A new method of knock detection in SI engines, using a change of ion concentration in the combustion chamber, was developed. In order to measure in-cylinder ionization current, ionization probes were installed at spark plug and cylinder head of production engine. It was found that the electric current generated by ionized gas in core burned gas region of knocking cycle is between 2 and 10 times larger than that of normal cycle, because the burned gas temperature which is the dominant parameter of a change of ion concentration increases. However, a change of ionization current in boundary region of burned gas is relatively weak. Hence a change of ion concentration in core burned gas region can be used for knock detection.

  • PDF

주사 전자 현미경에서 영상 획득에 필요한 구성 요소 구현 (Realization for Each Element for capturing image in Scanning Electron Microscopy)

  • 임선종;이찬홍
    • 한국레이저가공학회지
    • /
    • 제12권2호
    • /
    • pp.26-30
    • /
    • 2009
  • Scanning Electron Microscopy (SEM) includes high voltage generator, electron gun, column, secondary electron detector, scan coil system and image grabber. Column includes electron lenses (condenser lens and objective lens). Condenser lens generates fringe field, makes focal length and control spot size. Focal length represents property of lens. Objective lens control focus. Most of the electrons emitted from the filament, are captured by the anode. The portion of the electron current that leaves the gun through the hole in the anode is called the beam current. Electron beam probe is called the focused beam on the specimen. Because of the lens and aperture, the probe current becomes smaller than the beam current. It generate various signals(backscattered electron, secondary electron) in an interaction with the specimen atoms. In this paper, we describe the result of research to develop the core elements for low-resolution SEM.

  • PDF

Electromagnetic Susceptibility Analysis of I/O Buffers Using the Bulk Current Injection Method

  • Kwak, SangKeun;Nah, Wansoo;Kim, SoYoung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권2호
    • /
    • pp.114-126
    • /
    • 2013
  • In this paper, we present a set of methodologies to model the electromagnetic susceptibility (EMS) testing of I/O buffers for mobile system memory based on the bulk current injection (BCI) method. An efficient equivalent circuit model is developed for the current injection probe, line impedance stabilization network (LISN), printed circuit board (PCB), and package. The simulation results show good correlation with the measurements and thus, the work presented here will enable electromagnetic susceptibility analysis at the integrated circuit (IC) design stage.

원전SG세관의 결함크기에 따른 MRPC 프로브의 신호 해석 (Analysis of MRPC Probe Signal According to Defect Size Variation for S/G Tube in Nuclear Power Plant)

  • 김지호;송호준;임건규;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1008-1010
    • /
    • 2005
  • In the examination of steam generator(SG) tube in nuclear power plant, eddy current testing probes play an important role in detecting the defects. Bobbin probe and MRPC probe is usually used for the inspection of SG tube. Bobbin probe is good at high speed inspection, but ability of detection of circumferential defect is very weak. On the contrary MRPC probe, which moves for inspection in the direction of axial and circumferential simultaneously, has very slow inspection speed, but it has excellent detection capability for small cracks, which is hardly detected by bobbin probe. In this paper, for the accurate analysis of experimental ECT signals, construction of MRPC probe signals database according to the variation of defect size is the main purpose. Using 3-D finite element method, ECT signals are analyzed, and signals analysis add according to frequency ingredient. The results, which are analysis and characteristics ion of electromagnetism simulation signals, is databased.

  • PDF

원형튜브 단면형상검사용 와전류탐촉자 개발 (Development of Eddy Current Test Probe for Profilometry Inspection of Tube)

  • 이희종;남민우;이진황
    • 비파괴검사학회지
    • /
    • 제17권4호
    • /
    • pp.262-269
    • /
    • 1997
  • 발전 설비중 열교환기 튜브와 같이 단면 형상이 원형인 부품의 원주 방향으로 마모, 침식 등에 의해 발생할 수 있는 단면 형상 변화를 검사(profilometry)하기 위한 와전류 탐촉자를 임피던스 등가회로이론을 적용하여 개발하였다. 본 연구에서는 외경 9.68mm, 벽두께 0.47mm인 SS304 튜브 외부에 발생할 수 있는 마모, denting 등의 결함을 모의한 시편을 제작하여 실험을 통해 검출 감도와 S/N비가 최적인 탐촉자의 코일치수, 전기적 특성, 적용 시험 주파수 등을 설정하였다. 이 결과에 따라 단면 형상 검사용 $8{\times}1$ 다중표면 탐촉자를 설계 제작하여 모의시편의 각 결함별 마모율을 검사한 결과 튜브 외부 발생 단면 형상 변화를 튜브외경의 ${\pm}0.2%$ (0.022mm) 측정 오차 범위로 측정이 가능함을 확인하였다.

  • PDF

Ar 가스 압력과 RF 전력에 따른 유도결합형 플라즈마의 전기적 및 광학적 특성 (Electrical and Optical Characteristics of Inductively Coupled Plasma by Ar Gas Pressure and Rf Power)

  • 최용성;허인성;이영환;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제17권5호
    • /
    • pp.560-566
    • /
    • 2004
  • In this paper, the electrical and emission properties of electrodeless fluorescent lamp were discussed using the inductively coupled plasma (ICP) with the variation of argon gas pressure and RF power. The RF output was applied to the antenna in the range of 5∼50 W at 13.56 MHz. The internal plasma voltage of the chamber and the probe current were measured while varying the supply voltage to the Langmuir probe in the range of -100V∼+100V. When the pressure of argon gas was increased, electric current was decreased. There was a significant electric current increase from 10 to 30 W. Also, when the RF power was increased, electron density was increased. Also, the emission spectrum, Ar- I lins, luminance were investigated. At this time, the input parameter for ICP RF plasma, Ar gas pressure and RF power were applied in the range of 10∼60 mTorr, 10∼300 W, respectively. This implies that this method can be used to find an optimal RF power for efficient light illumination in an electrodeless fluorescent lamp.