• Title/Summary/Keyword: Probe block

검색결과 61건 처리시간 0.024초

블록체인을 적용한 사설 클라우드 기반 침입시도탐지 (A Probe Detection based on Private Cloud using BlockChain)

  • 이세열
    • 디지털산업정보학회논문지
    • /
    • 제14권2호
    • /
    • pp.11-17
    • /
    • 2018
  • IDS/IPS and networked computer systems are playing an increasingly important role in our society. They have been the targets of a malicious attacks that actually turn into intrusions. That is why computer security has become an important concern for network administrators. Recently, various Detection/Prevention System schemes have been proposed based on various technologies. However, the techniques, which have been applied in many systems is useful for existing intrusion patterns on standard-only systems. Therefore, probe detection of private clouds using BlockChain has become a major security protection technology to detection potential attacks. In addition, BlockChain and Probe detection need to take into account the relationship between the various factors. We should develop a new probe detection technology that uses BlockChain to fine new pattern detection probes in cloud service security in the end. In this paper, we propose a probe detection using Fuzzy Cognitive Map(FCM) and Self Adaptive Module(SAM) based on service security using BlockChain technology.

미세피치의 Probe Unit용 Slit Etching 고정 및 특성 연구

  • 김진혁;신광수;김선훈;고항주;김효진;송민종;한명수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.177-177
    • /
    • 2010
  • 본 연구에서는 반도체용 Si wafer에 마스크 공정 및 slit etching 공정을 적용하여 목표인 30um 이하의 Probe unit을 개발하기 위해 Deep Si Etching(DRIE) 장비를 이용하여 식각 공정에 따른 특성을 평가하였다. 마스크는 Probe block 조립에 적합한 패턴으로 설계 하였으며, slit의 에칭된 지점에 pin이 삽입될 수 있도록 그 폭을 최소한으로 설계하였다. 30um pitch와 20um pitch의 마스크를 각각 설계하여 포토공정에 의해 마스크패턴을 제작하였으며, 식각공정 결과 식각율 5um/min, profile angle $89^{\circ}{\pm}1^{\circ}$로 400um wafer의 양면관통 식각을 확인하였으며, 표면 및 단면 식각특성을 조사하였다.

  • PDF

2차원 프로브에 의한 NC공작기계의 운동 정밀도 측정 -제2보 직선운동 정밀도 측정- (Measurement of Motion Accuracy by Two-dimensional Probe on NC Machine Tools -2nd Report, Measurement of the Linear Motion Accuracy-)

  • 전언찬;소산전중덕;제정신;각전윤일랑
    • 한국정밀공학회지
    • /
    • 제14권7호
    • /
    • pp.15-21
    • /
    • 1997
  • This paper presented a linear motion accuracy by using two-dimensional probe with the master block and the square for NC machine tools. This measuring system could be measured motion error due to numerical control system. The results of measurement and simulation for motion error were similar, and so, this system had enough accuracy to measure a linear motion accuracy for NC machine tools. The experimental results are as follows. 1. This measuring system could be measured motion error due to mumerical control system. 2. The results of measurement and simulation for motion error were similar. 3. This measuring system had enough accuracy to measure a linear motion accuracy for NC machine tools.

  • PDF

Synthesis and Characterization of MPEG-b-PDPA Amphiphilic Block Copolymer via Atom Transfer Radical Polymerization and Its pH-Dependent Micellar Behavior

  • Dayananda, Kasala;Kim, Min-Sang;Kim, Bong-Sup;Lee, Doo-Sung
    • Macromolecular Research
    • /
    • 제15권4호
    • /
    • pp.385-391
    • /
    • 2007
  • Block copolymer micelles are generally formed via the self-assembly of amphiphilic block copolymers in an aqueous medium. The hydrophilic and hydrophobic blocks form shell and core micelles, respectively. The block copolymers of methoxy poly(ethylene glycol) (MPEG)-b-poly(2-diisopropylamino)ethyl methacrylate (PDPA) were synthesized via atom transfer radical polymerization, with the macro initiator synthesized by the coupling of 2-bromoisobutyryl bromide with MPEG in the presence of a triethyl amine base catalyst. The atom transfer radical polymerization of 2-diisopropylamino)ethyl methacrylate was performed in conjunction with an N,N,N',N",N"-pentamethyl-diethylenetriamine/copper bromide catalyst system, in DMF, at $70^{\circ}C$. The pH induced micellization/demicellization was studied using fluorescence, with a pyrene probe. Furthermore, the pH dependent micellization was confirmed using the microviscosity method, with a dipyme fluorescence probe. The pH dependant micelle size distribution was studied using dynamic light scattering. The characterization of the synthesized polymers was established using gel permeation chromatography and from the $^1H-nuclear$ magnetic resonance spectroscopy.

Synthesis of New pH-Sensitive Amphiphilic Block Copolymers and Study for the Micellization Using a Fluorescence Probe

  • Kim, Kyung-Min;Choi, Song-Yee;Jeon, Hee-Jeong;Lee, Jae-Yeol;Choo, Dong-Joon;Kim, Jung-Ahn;Kang, Yong-Soo;Yoo, Hyun-Oh
    • Macromolecular Research
    • /
    • 제16권2호
    • /
    • pp.169-177
    • /
    • 2008
  • This paper reports a facile synthesis of new water-soluble poly(ethylene oxide) (PEO)-based amphiphilic block copolymers showing pH sensitive phase transition behaviors. The copolymers were prepared by atom transfer radical polymerization (ATRP) of methacrylamide type of monomers carrying a sulfonamide group using a PEO-based macroinitiator and a Cu(I)Br/$Me_6TREN$ catalytic system in aqueous media. The resulting polymers were characterized by a combination of $^1H$-NMR, size exclusion chromatography, and UV/Visible spectrophotometeric analysis. The micellization of the block copolymers as a drug-loading mechanism in aqueous media using fluorescein salt was examined as a function of pH. The stable micelle formation and its loading efficacy suggest that the block copolymers can be used as precursors for drug-nanocontainers.

강구조물(鋼構造物) 진단(診斷)을 위한 초음파(超音波) 센서 (Ultrasonic Sensors for Steel Structure Inspection)

  • 신병철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제2권2호
    • /
    • pp.170-176
    • /
    • 1998
  • The team mixed PbO, $ZrO_2$, $TiO_2$, $Nb_2O_5$ and $MnCO_3$, to make $Pb[(Zr_{0.54}\;Ti_{0.46})\;Nb_{0.005}]O_3+4%MnCO_3$. The electroded PZT ceramics were poled by 3 kV/mm at $110^{\circ}C$ for 600 s. We assembled the 0.4mm thick PZT slices into ultrasonic transducers. Central frequency of the probe is 5 MHz, which is proper to the thickness gauge for steel pipes and for flaw detector. The probe can detect a disk shape defect of 1mm diameter at 15cm deep in steel block. The new probe's Fresnel zone that the ultrasonic beam do not broaden is 13mm. Over the Fresnel zone, the ultrasonic beam spreads. Half of the beam spread angle of the probe is $4.3^{\circ}-4.6^{\circ}$. This probe can be used for the ultrasonic transducers for non-destructive testing of steel bridges.

  • PDF

3차원 초음파 시스템의 캘리브레이션 방법 (Calibration Technique for Freehand 3-D Ultrasound System)

  • 황면중
    • 한국산학기술학회논문지
    • /
    • 제14권12호
    • /
    • pp.6066-6071
    • /
    • 2013
  • 본 논문에서는 의료용 초음파를 이용하는 로봇 시스템을 위한 3차원 캘리브레이션 방법을 제안한다. 고정된 기준점을 구성하기 위한 캘리브레이션 블록을 제작한 후 옵티컬 트래커(optical tracker)를 이용하여 초음파 프루브(probe)의 위치와 기준점의 위치를 측정한다. 초음파 영상의 픽셀 좌표와 센서로 측정된 위치를 비교하여 6개의 파라미터로 이루어진 초음파 프루브와 영상 내의 픽셀 좌표와의 관계 행렬을 구하고 2개의 파라미터로 이루어진 스케일링 행렬을 계산한다. 정밀한 캘리브레이션을 위해 캘리브레이션 블록 내부 모양과 매질 선택에 대한 적절성을 실험을 통해 검증한다. 제안된 방법은 간단한 형태의 캘리브레이션 블록과 옵티컬 트래커를 사용하여 설치에 많은 시간이 필요하지 않는 장점이 있기 때문에 초음파 영상을 이용하는 로봇 작업에 널리 적용이 가능하다.

다한증 환자에서 흉부 교감신경절 차단과 인지 체온 변화와의 관계 (Changes of Index Finger Temperature as Indices of Success of Thoracic Sympathetic Ganglion Block)

  • 이효근;윤경봉;서영선;김찬
    • The Korean Journal of Pain
    • /
    • 제7권2호
    • /
    • pp.217-221
    • /
    • 1994
  • Percutaneous neurolysis of upper thoracic sympathetic ganglion was performed in 40 patients by simultaneously injecting 3 ml of pure alcohol into the T2 and T3 levels after 3 ml of injection of local anesthetic agent on the same sites. Using a skin temperature probe, finger tip temperatures were measured on the index finger ipsilateral to the nerve block before block, 15 and 30 minutes after test block, and 30 minutes after alcohol block. Alcohol block was performed immediately after 30 minutes test block. Finger tip temperatures obtained at 30 minutes post alcohol block and test block and the differences in the temperatures measured before and 30 minutes after alcohol block were shown to be statistically important as potential indicators for prediciting long term outcome of therapy for palmar hyperhidrosis using this technique. These results demonstrate that the palmar temperature monitoring method is sufficiently sensitive to predict the outcome of nerve block during and after thoracic sympathetic ganglion block.

  • PDF

전자현미경 In Situ Hybridization에 의한 Viral RNA의 진단에 관한 연구 (Studies on In Situ Hybridization of Electron Microscopy for Detection of Viral RNA)

  • 최원기;주경웅;김석홍
    • 대한의생명과학회지
    • /
    • 제2권2호
    • /
    • pp.257-265
    • /
    • 1996
  • 토끼 바이러스성 출혈증의 원인체를 실험 토끼에 접종하여 증식을 유도하고 간장에서 hematoxylin & eosin 염 색 에서 조직학적 진단과 세포내 viral RNA의 소재를 결정하기 위해 post-unicryl 포매한 block의 절편을 사용하여 단 염색과 전자현미경적 in situ hybridization을 시도하였다. 토끼 출혈증 viral RNA의 보합 결합에 이용하는 probe는 4717에서 4800(84bases)까지 oligonucleotide를 5'말단에 biotin-CE phosphoramidite로 표지하여 사용하였다. 보합결합물의 증명은 신호 표지로서 antibiotin antibody-l0nm gold를 사용하였으며, hybridization이나 증명은 기존 protocol에서 약간의 변법을 사용하였다. 0.02% glutaraldehyde에서 고정하고 unicryl resin 포매한 표본, biotinylated oligonucleotide probe, antibiotin antibody-l0nm gold로 실험한 결과 증강된 신호를 얻을 수 있었다. 특히 전처리를 생략하므로써 실험 과정을 간단하게 하여 신속한 결과를 얻을 수가 있었다. 전자현미경 in situ hybridization을 통하여 토끼 출혈증 바이러스의 주요 표적은 간세포로 감염 세포의 세포질 내 미토콘드리아와 핵 사이에서 immune gold입자가 뚜렷하게 표지 됨으로서 viral RNA를 증명할 수 있었다.

  • PDF

화상인식을 이용한 시각장애인용 보행보조장치 (Ambulatory Aid Device for the Visually Handicapped Person Using Image Recognition)

  • 박상준;신동원
    • 제어로봇시스템학회논문지
    • /
    • 제12권6호
    • /
    • pp.568-572
    • /
    • 2006
  • This paper presents the device of recognizing image of the studded paving blocks, transmitting, the information by vibration to a visually handicapped person. Usually the blind uses the walking stick to recognize the studded paving block. This research uses a PCA (Principal Component Analysis) based image processing approach for recognizing the paving blocks. We classify the studded paving blocks into 5 classes, that is, vertical line block, right-declined line block, left-declined line block, dotted block and flat block. The 8 images for each of 5 classes are captured for each block by 112*120 pixels, then the eigenvectors are obtained in magnitude order of eigenvectors by using principal component analysis. The principal components for images can be calculated using projection of transformation matrix composed of eigenvectors. The classification has been executed using Euclidean's distance, so the block having minimum distance with a image is chosen as matched one. The result of classification is transmitted to the blind by electric vibration signals with different magnitudes and frequencies.