• Title/Summary/Keyword: Probe block

Search Result 61, Processing Time 0.021 seconds

A Probe Detection based on Private Cloud using BlockChain (블록체인을 적용한 사설 클라우드 기반 침입시도탐지)

  • Lee, Seyul
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.2
    • /
    • pp.11-17
    • /
    • 2018
  • IDS/IPS and networked computer systems are playing an increasingly important role in our society. They have been the targets of a malicious attacks that actually turn into intrusions. That is why computer security has become an important concern for network administrators. Recently, various Detection/Prevention System schemes have been proposed based on various technologies. However, the techniques, which have been applied in many systems is useful for existing intrusion patterns on standard-only systems. Therefore, probe detection of private clouds using BlockChain has become a major security protection technology to detection potential attacks. In addition, BlockChain and Probe detection need to take into account the relationship between the various factors. We should develop a new probe detection technology that uses BlockChain to fine new pattern detection probes in cloud service security in the end. In this paper, we propose a probe detection using Fuzzy Cognitive Map(FCM) and Self Adaptive Module(SAM) based on service security using BlockChain technology.

미세피치의 Probe Unit용 Slit Etching 고정 및 특성 연구

  • Kim, Jin-Hyeok;Sin, Gwang-Su;Kim, Seon-Hun;Go, Hang-Ju;Kim, Hyo-Jin;Song, Min-Jong;Han, Myeong-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.177-177
    • /
    • 2010
  • 본 연구에서는 반도체용 Si wafer에 마스크 공정 및 slit etching 공정을 적용하여 목표인 30um 이하의 Probe unit을 개발하기 위해 Deep Si Etching(DRIE) 장비를 이용하여 식각 공정에 따른 특성을 평가하였다. 마스크는 Probe block 조립에 적합한 패턴으로 설계 하였으며, slit의 에칭된 지점에 pin이 삽입될 수 있도록 그 폭을 최소한으로 설계하였다. 30um pitch와 20um pitch의 마스크를 각각 설계하여 포토공정에 의해 마스크패턴을 제작하였으며, 식각공정 결과 식각율 5um/min, profile angle $89^{\circ}{\pm}1^{\circ}$로 400um wafer의 양면관통 식각을 확인하였으며, 표면 및 단면 식각특성을 조사하였다.

  • PDF

Measurement of Motion Accuracy by Two-dimensional Probe on NC Machine Tools -2nd Report, Measurement of the Linear Motion Accuracy- (2차원 프로브에 의한 NC공작기계의 운동 정밀도 측정 -제2보 직선운동 정밀도 측정-)

  • JEON, Eon Chan;OYAMADA, Shigenori;TSUTSUMI, Masaomi;KAKUTA, Junichro
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.7
    • /
    • pp.15-21
    • /
    • 1997
  • This paper presented a linear motion accuracy by using two-dimensional probe with the master block and the square for NC machine tools. This measuring system could be measured motion error due to numerical control system. The results of measurement and simulation for motion error were similar, and so, this system had enough accuracy to measure a linear motion accuracy for NC machine tools. The experimental results are as follows. 1. This measuring system could be measured motion error due to mumerical control system. 2. The results of measurement and simulation for motion error were similar. 3. This measuring system had enough accuracy to measure a linear motion accuracy for NC machine tools.

  • PDF

Synthesis and Characterization of MPEG-b-PDPA Amphiphilic Block Copolymer via Atom Transfer Radical Polymerization and Its pH-Dependent Micellar Behavior

  • Dayananda, Kasala;Kim, Min-Sang;Kim, Bong-Sup;Lee, Doo-Sung
    • Macromolecular Research
    • /
    • v.15 no.4
    • /
    • pp.385-391
    • /
    • 2007
  • Block copolymer micelles are generally formed via the self-assembly of amphiphilic block copolymers in an aqueous medium. The hydrophilic and hydrophobic blocks form shell and core micelles, respectively. The block copolymers of methoxy poly(ethylene glycol) (MPEG)-b-poly(2-diisopropylamino)ethyl methacrylate (PDPA) were synthesized via atom transfer radical polymerization, with the macro initiator synthesized by the coupling of 2-bromoisobutyryl bromide with MPEG in the presence of a triethyl amine base catalyst. The atom transfer radical polymerization of 2-diisopropylamino)ethyl methacrylate was performed in conjunction with an N,N,N',N",N"-pentamethyl-diethylenetriamine/copper bromide catalyst system, in DMF, at $70^{\circ}C$. The pH induced micellization/demicellization was studied using fluorescence, with a pyrene probe. Furthermore, the pH dependent micellization was confirmed using the microviscosity method, with a dipyme fluorescence probe. The pH dependant micelle size distribution was studied using dynamic light scattering. The characterization of the synthesized polymers was established using gel permeation chromatography and from the $^1H-nuclear$ magnetic resonance spectroscopy.

Synthesis of New pH-Sensitive Amphiphilic Block Copolymers and Study for the Micellization Using a Fluorescence Probe

  • Kim, Kyung-Min;Choi, Song-Yee;Jeon, Hee-Jeong;Lee, Jae-Yeol;Choo, Dong-Joon;Kim, Jung-Ahn;Kang, Yong-Soo;Yoo, Hyun-Oh
    • Macromolecular Research
    • /
    • v.16 no.2
    • /
    • pp.169-177
    • /
    • 2008
  • This paper reports a facile synthesis of new water-soluble poly(ethylene oxide) (PEO)-based amphiphilic block copolymers showing pH sensitive phase transition behaviors. The copolymers were prepared by atom transfer radical polymerization (ATRP) of methacrylamide type of monomers carrying a sulfonamide group using a PEO-based macroinitiator and a Cu(I)Br/$Me_6TREN$ catalytic system in aqueous media. The resulting polymers were characterized by a combination of $^1H$-NMR, size exclusion chromatography, and UV/Visible spectrophotometeric analysis. The micellization of the block copolymers as a drug-loading mechanism in aqueous media using fluorescein salt was examined as a function of pH. The stable micelle formation and its loading efficacy suggest that the block copolymers can be used as precursors for drug-nanocontainers.

Ultrasonic Sensors for Steel Structure Inspection (강구조물(鋼構造物) 진단(診斷)을 위한 초음파(超音波) 센서)

  • Shin, Byoung-Churl
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.2
    • /
    • pp.170-176
    • /
    • 1998
  • The team mixed PbO, $ZrO_2$, $TiO_2$, $Nb_2O_5$ and $MnCO_3$, to make $Pb[(Zr_{0.54}\;Ti_{0.46})\;Nb_{0.005}]O_3+4%MnCO_3$. The electroded PZT ceramics were poled by 3 kV/mm at $110^{\circ}C$ for 600 s. We assembled the 0.4mm thick PZT slices into ultrasonic transducers. Central frequency of the probe is 5 MHz, which is proper to the thickness gauge for steel pipes and for flaw detector. The probe can detect a disk shape defect of 1mm diameter at 15cm deep in steel block. The new probe's Fresnel zone that the ultrasonic beam do not broaden is 13mm. Over the Fresnel zone, the ultrasonic beam spreads. Half of the beam spread angle of the probe is $4.3^{\circ}-4.6^{\circ}$. This probe can be used for the ultrasonic transducers for non-destructive testing of steel bridges.

  • PDF

Calibration Technique for Freehand 3-D Ultrasound System (3차원 초음파 시스템의 캘리브레이션 방법)

  • Hwang, Myun Joong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6066-6071
    • /
    • 2013
  • This paper proposes a calibration method for a freehand 3-D ultrasound system in medical robotic research. The calibration block with six wires was designed to set the fixed target points. The positions of the ultrasound probe and calibration block were measured using an optical tracker. The relationship between the position of the ultrasound probe and the pixel coordinates in the images was derived using a calibration process. The scaling matrix was also calculated. The experimental results showed that the proposed method could find solutions using a simple least square method from one or multiple ultrasound images.

Changes of Index Finger Temperature as Indices of Success of Thoracic Sympathetic Ganglion Block (다한증 환자에서 흉부 교감신경절 차단과 인지 체온 변화와의 관계)

  • Lee, Hyo-Keun;Yoon, Kyung-Bong;Suh, Young-Sun;Kim, Chan
    • The Korean Journal of Pain
    • /
    • v.7 no.2
    • /
    • pp.217-221
    • /
    • 1994
  • Percutaneous neurolysis of upper thoracic sympathetic ganglion was performed in 40 patients by simultaneously injecting 3 ml of pure alcohol into the T2 and T3 levels after 3 ml of injection of local anesthetic agent on the same sites. Using a skin temperature probe, finger tip temperatures were measured on the index finger ipsilateral to the nerve block before block, 15 and 30 minutes after test block, and 30 minutes after alcohol block. Alcohol block was performed immediately after 30 minutes test block. Finger tip temperatures obtained at 30 minutes post alcohol block and test block and the differences in the temperatures measured before and 30 minutes after alcohol block were shown to be statistically important as potential indicators for prediciting long term outcome of therapy for palmar hyperhidrosis using this technique. These results demonstrate that the palmar temperature monitoring method is sufficiently sensitive to predict the outcome of nerve block during and after thoracic sympathetic ganglion block.

  • PDF

Studies on In Situ Hybridization of Electron Microscopy for Detection of Viral RNA (전자현미경 In Situ Hybridization에 의한 Viral RNA의 진단에 관한 연구)

  • 최원기;주경웅;김석홍
    • Biomedical Science Letters
    • /
    • v.2 no.2
    • /
    • pp.257-265
    • /
    • 1996
  • Simple stain and electron microscopic in situ hybridization is studied and applied for the identification of rabbit haemorrhagic disease viral RNA in a unicrylated preparation of the liver after innoculation of rabbit haemorrhagic disease virus. Hybridization for detection of viral RNA in unicryl embedded tissues using complementary 84 bases oligonucleotide probe labelled by biotin CE-phosphoramidite compared with 4717∼4800 sequences of rabbit haemorrhagic disease virus, modified hybridization protocol and antibiotin antibody-l0nm gold as signal marker. The best results were obtained in 0.02% glutaraldehyde, Unicryl resin cell block, biotinylated oligonucleotide probes, antibiotin-l0nm gold. In this report, RHD viral RNA was distributed widely within the mitochondria and nucleus of liver cell by electron microscopic in situ hybridization. In situ hybridization has become a standard method for localizing DNA or RNA sequences in tissue or celt preparation. In situ hybridization is detected the virus genome in the cells and tissue as specifically compared with others nucleic acid hybridization method.

  • PDF

Ambulatory Aid Device for the Visually Handicapped Person Using Image Recognition (화상인식을 이용한 시각장애인용 보행보조장치)

  • Park Sang-Jun;Shin Dong-Won
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.6
    • /
    • pp.568-572
    • /
    • 2006
  • This paper presents the device of recognizing image of the studded paving blocks, transmitting, the information by vibration to a visually handicapped person. Usually the blind uses the walking stick to recognize the studded paving block. This research uses a PCA (Principal Component Analysis) based image processing approach for recognizing the paving blocks. We classify the studded paving blocks into 5 classes, that is, vertical line block, right-declined line block, left-declined line block, dotted block and flat block. The 8 images for each of 5 classes are captured for each block by 112*120 pixels, then the eigenvectors are obtained in magnitude order of eigenvectors by using principal component analysis. The principal components for images can be calculated using projection of transformation matrix composed of eigenvectors. The classification has been executed using Euclidean's distance, so the block having minimum distance with a image is chosen as matched one. The result of classification is transmitted to the blind by electric vibration signals with different magnitudes and frequencies.