• 제목/요약/키워드: Probe's

검색결과 1,466건 처리시간 0.032초

강구조물(鋼構造物) 진단(診斷)을 위한 초음파(超音波) 센서 (Ultrasonic Sensors for Steel Structure Inspection)

  • 신병철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제2권2호
    • /
    • pp.170-176
    • /
    • 1998
  • The team mixed PbO, $ZrO_2$, $TiO_2$, $Nb_2O_5$ and $MnCO_3$, to make $Pb[(Zr_{0.54}\;Ti_{0.46})\;Nb_{0.005}]O_3+4%MnCO_3$. The electroded PZT ceramics were poled by 3 kV/mm at $110^{\circ}C$ for 600 s. We assembled the 0.4mm thick PZT slices into ultrasonic transducers. Central frequency of the probe is 5 MHz, which is proper to the thickness gauge for steel pipes and for flaw detector. The probe can detect a disk shape defect of 1mm diameter at 15cm deep in steel block. The new probe's Fresnel zone that the ultrasonic beam do not broaden is 13mm. Over the Fresnel zone, the ultrasonic beam spreads. Half of the beam spread angle of the probe is $4.3^{\circ}-4.6^{\circ}$. This probe can be used for the ultrasonic transducers for non-destructive testing of steel bridges.

  • PDF

3축 열선 PROBE의 특성과 그 평가 (The Characteristics of Triple Hot-Wire Probe and It's Evaluation)

  • 김경훈
    • 한국정밀공학회지
    • /
    • 제5권3호
    • /
    • pp.48-62
    • /
    • 1988
  • A triple hot-wire probe has an essential potentiality for the measure- ment of an instantaneous velocity vector in a three dimensional unsteady flow with large amplitude of velocity fluctuations, the key problems asso- ciated with this instrument are the directional range of applicability and the accuracy. This present paper is concerned with a new method of the techniques of calibration and data processing to estimate the three dimensional flow field using an arbitrary shaped triple hot-wire probe. The method is not based on the assumptions of orthogonality or symmetry and it is especially useful for applications to a hand-made probe where probe geometry is not accurately known. The test application is made to evaluate the effect of cone angles of symmetric non-orthogonal probe.

  • PDF

Hall Probe를 이용한 초전도선재의 비접촉 임계전류 측정 방법 (Non-contact critical current measurement of superconducting coated conductor using Hall Probe)

  • 김호섭;오상수;이남진;하동우;백승규;고락길;하홍수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.12-12
    • /
    • 2010
  • The hall probe measurement system was used to measure the critical current distribution of superconducting coated conductor. The system consists of reel to reel moving apparatus, 7 array hall probe, a rotary encoder and permanent magnet. The magnetic field profile across the width of superconducting coated conductor using Bean's critical state model was calculated. The effect of various parameters of the formulas on the magnetic field distribution and the effect of shape and size of artificial defects, which were formed on the surface of SmBa2Cu3O7-d(SmBCO) coated conductor using laser marking system, on the hall probe magnetic field signal of the hall probe measurement system was investigated.

  • PDF

${\epsilon}$-다중목적 진화연산을 이용한 DNA Microarray Probe 설계 (A Probe Design Method for DNA Microarrays Using ${\epsilon}$-Multiobjetive Evolutionary Algorithms)

  • 조영민;신수용;이인희;장병탁
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2006년도 한국컴퓨터종합학술대회 논문집 Vol.33 No.1 (A)
    • /
    • pp.82-84
    • /
    • 2006
  • 최근의 생물학적인 연구에 DNA microarray가 널리 쓰이고 있기 때문에, 이러한 DNA microarray를 구성하는데 필요한 probe design 작업의 중요성이 점차 커져가고 있다. 이 논문에서는 probe design 문제를 thermodynamic fitness function이 2개인 multi-objective optimization 작업으로 변환한 뒤, ${\epsilon}$-multiobjective evolutionary algorithm을 이용하여 probe set을 찾는다. 또한, probe 탐색공간의 크기를 줄이기 위하여 각 DNA sequence의 primer 영역을 찾는 작업을 진행하며, 사용자가 직접 프로그램을 테스트할 수 있는 웹사이트를 제공한다. 실험 대상으로는 mycoides를 선택하였으며, 이 논문에서 제안된 방법을 사용하여 성공적으로 probe set을 발견할 수 있었다.

  • PDF

Wafer Pin Array Frame을 이용한 Probe Head Module (Make Probe Head Module use of Wafer Pin Array Frame)

  • 이재하
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2012년도 추계총회 및 학술대회 논문집
    • /
    • pp.71-71
    • /
    • 2012
  • Memory 반도체 Test공정에서 사용되는 Probe Card의 Probing Area가 넓어지면서 종래에 사용되던 Cantilever제품의 사용이 불가능하게 되고, MEMS공정을 사용한 새로운 형태의 Advanced제품이 시장에 출현을 하였다. MEMS형의 제품은 다수의 Micro Spring을 MLC(Multi Layer Ceramic)위에 MEMS 공정을 사용하여 생성하는 방식으로서 MLC는 좁은 지역에 다수의 Pin을 생성 할 수 있는 공간을 만들어 주며, 또 다른 이유는 전기적 특성인 임피던스를 맞추고 다수의 Pin의 압력에 의하여 생기는 하중을 Ceramic기판으로 지탱하기 위한 목적도 있다. 이에 MLC와 같은 전기적 특성을 임피던스를 맞춘 RF-CPCB를 사용하여 작은 면적에 다수의 Pin접합이 가능한 방법을 마련한 후, 이 RF-PCB를 부착하여 Pin의 하중을 받는 Wafer와 유사한 열팽창을 갖는 Substrate를 사용하여 MLC를 대체하여 다양한 온도 조건에서 사용이 가능하며, 복잡하고 공정비가 많이 드는 MEMS 공정에 의한 일괄 Micro Spring 생성 공정을 전주 도금 또는 2D방식의 도금 Pin으로 대체하였으며, Probe Card의 중요한 물리적 특성인 Pin들의 정렬도를 마련하기 위해 Photo Process를 사용한 Wafer로 만든 Wafer Pin Array Frame을 사용하여 2D 제작 Pin을 일괄 또는 부분 접합이 가능한 방법으로 Probe Array Head를 제작하여 이들을 부착하여 Probe Array Head를 이전의 MEMS공정 방법에 비해 쉽고 빠르게 만들어 probe Card를 제작 할 수 있게 되었다.

  • PDF

Study on Validity and Reliablity of the Cutoff Probe and Langmuir Probe via Comparative Experiment in the Processing Plasma

  • Kim, D.W.;You, S.J.;You, K.H.;Lee, J.W.;Kim, J.H.;Chang, H.Y.;Oh, W.Y.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.576-576
    • /
    • 2013
  • Recently, diagnostics of plasma becomes more important due to requirement of precise control of plasma processing based on measurement of plasma characteristics. The Langmuir probe has been used for the diagnostics but it has an inevitable uncertainty and error sources such as incorrect tip length and RF noise. Instead of the Langmuir probe, various diagnostic methods have been developed and researched. The cutoff probe is promising one for plasma density using microwaves and resonance phenomenon at the plasma frequency. The cutoff probe has various advantages as follows; (i) it is simple and robust, (ii) it uses few assumptions, and (iii) it is free from deposition by reactive gas. However, the cutoff probe also has uncertainty and error sources such as gap between tips, tip length, direction of tip plane, and RF noise. In this study, the uncertainty and error sources in manufacturing both probes and in diagnostics process were analyzed via comparative experiment at various discharge conditions. Furthermore, to reveal the user dependence of both probes, three well trained Ph. D students made the Langmuir probe and the cutoff probe, respectively, and it were analyzed. Thought this study, it is established that reliability and validity of the Langmuir probe and the cutoff probe related with not only the intrinsic characteristics of probes but also probe user.

  • PDF

An Adaptive Probe Detection Model using Fuzzy Cognitive Maps

  • Lee, Se-Yul;Kim, Yong-Soo
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2003년도 ISIS 2003
    • /
    • pp.660-663
    • /
    • 2003
  • The advanced computer network technology enables connectivity of computers through an open network environment. There has been growing numbers of security threat to the networks. Therefore, it requires intrusion detection and prevention technologies. In this paper, we propose a network based intrusion detection model using Fuzzy Cognitive Maps(FCM) that can detect intrusion by the Denial of Service(DoS) attack detection method adopting the packet analyses. A DoS attack appears in the form of the Probe and Syn Flooding attack which is a typical example. The Sp flooding Preventer using Fuzzy cognitive maps(SPuF) model captures and analyzes the packet information to detect Syn flooding attack. Using the result of analysis of decision module, which utilized FCM, the decision module measures the degree of danger of the DoS and trains the response module to deal with attacks. The result of simulating the "KDD ′99 Competition Data Set" in the SPuF model shows that the Probe detection rates were over 97 percentages.

  • PDF

Coated conductor에서 magneto-optical image와 scanning hall probe를 이용한 flux profile의 측정 및 분석 (Measurement and Analysis of the Flux Profiles of the Coated Conductors using Magneto-optical Image and Scanning Hall Probe)

  • 이효연;곽기성;이준규;유재은;염도준
    • Progress in Superconductivity
    • /
    • 제11권2호
    • /
    • pp.128-134
    • /
    • 2010
  • The magnetic flux profiles in SmBCO and YBCO coated conductors(CC) in the presence of the external field were comparatively investigated by magneto-optic image and scanning hall probe measurements. The current distributions calculated by using the inversion method from measured field profiles show that the decrease of current densities near the edges of SmBCO CC is more significant than those of YBCO CC. Through the comparison of the numerical analysis based on Kim's critical state model and the Brandt and Indenbom's solution, we found that this feature is related to their different field dependant properties of the critical current densities.

Design of Hybrid Network Probe Intrusion Detector using FCM

  • Kim, Chang-Su;Lee, Se-Yul
    • Journal of information and communication convergence engineering
    • /
    • 제7권1호
    • /
    • pp.7-12
    • /
    • 2009
  • The advanced computer network and Internet technology enables connectivity of computers through an open network environment. Despite the growing numbers of security threats to networks, most intrusion detection identifies security attacks mainly by detecting misuse using a set of rules based on past hacking patterns. This pattern matching has a high rate of false positives and can not detect new hacking patterns, making it vulnerable to previously unidentified attack patterns and variations in attack and increasing false negatives. Intrusion detection and prevention technologies are thus required. We proposed a network based hybrid Probe Intrusion Detection model using Fuzzy cognitive maps (PIDuF) that detects intrusion by DoS (DDoS and PDoS) attack detection using packet analysis. A DoS attack typically appears as a probe and SYN flooding attack. SYN flooding using FCM model captures and analyzes packet information to detect SYN flooding attacks. Using the result of decision module analysis, which used FCM, the decision module measures the degree of danger of the DoS and trains the response module to deal with attacks. For the performance evaluation, the "IDS Evaluation Data Set" created by MIT was used. From the simulation we obtained the max-average true positive rate of 97.064% and the max-average false negative rate of 2.936%. The true positive error rate of the PIDuF is similar to that of Bernhard's true positive error rate.