• Title/Summary/Keyword: Prism sheet

Search Result 39, Processing Time 0.019 seconds

Flat Fluorescent Lamp for LCD Backlighting (LCD 후면 광원용 평판형광램프)

  • Kwon, Soon-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.15-19
    • /
    • 2007
  • A 15[inch] diagonal mercury-free flat discharge lamp with insulated electrode has been developed as backlight for a LCD backlighting. When the drive voltage pulse conditions were set properly, a uniform and stable discharge extends over the entire volume. It was obtained luminance of $10,330[cd/m^2]$ without prism sheet in uniform and stable discharge.

A Study on the Fabrication of Porous Nickel Substrates (다공성 니켈지지체의 제조에 관한 연구)

  • 신동엽;조원일;백지흠;조병원;강탁;윤경석
    • Journal of the Korean institute of surface engineering
    • /
    • v.28 no.3
    • /
    • pp.123-132
    • /
    • 1995
  • While a nickel mesh and an expanded nickel sheet are used as current collectors for supporting active anode materials in rechargeable batteries, a porous nickel substrate is studied extensively for its 3-dimensional structure which has high capabilities for active materials and current collection. Optimum plating conditions were studied by polarization measurement. Scanning Electron Microscopy (SEM) showed that both electroless-and electro-plated nickel on an urethane substrate were highly porous and consisted of nearly spherical pores. The diameter and the channel size of the pores were found to be 300~500 $\mu\textrm{m}$ and 50~200$\mu\textrm{m}$, respectively. The shape of skeleton resembled a triangular prism with length extending about 50~100 $\mu\textrm{m}$.

  • PDF

An Experimental Study on the Replication Ratio of Micro Patterns of 7 inch LGP using Injection/Compression and RHCM (사출/압축 및 RHCM 기술이 7인치 도광판 마이크로 패턴 전사성에 미치는 영향에 대한 실험적 연구)

  • Cho, S.W.;Kim, J.S.;Hwang, C.J.;Yoon, K.H.;Kang, J.J.
    • Transactions of Materials Processing
    • /
    • v.20 no.1
    • /
    • pp.11-16
    • /
    • 2011
  • Recently, according to the rapid development of display, many display applications, such as, cellular phone, navigation, monitor and LCD TV have been changed from CRT type to LCD type. BLU(Back Light Unit) is one of main parts in LCD unit and generally, it consists of a light source, a reflective sheet, a LGP(Light Guide Plate), a diffuser sheet, and two prism sheets. The most important component of BLU is a light guide plate, which diffuses the input light to the TFT-LCD module uniformly. The LGP is usually made by injection molding process, and it has numerous optical micro patterns on the surface. In the present study the micro-patterned stamper which has cylindrical shape was fabricated by using the UV-LiGA process. And the replication characteristics have been compared among three different kinds of injection molding process; general injection molding, injection/compression molding and RHCM(Rapid Heating and Cooling Molding). Average replication ratios of CIM and ICM were 19.1% and 64.6%, respectively. On the other hand, the average replication ratio of RHCM process showed the higher value of 98.4% among these. It show that maintaining the mold surface above $T_g$ could increase the replication ratio of micro patterns substantially.

Luminance Normalization of Optical Sheets in a Backlight Unit for LCD-TVs (LCD-TV용 백라이트 광학시트의 휘도 정량화)

  • Jeong, Jong-Mun;Kim, Jung-Hyun;Shin, Myeong-Ju;Lee, Mi-Ran;Chung, Jae-Yoon;Jeong, Hee-Suk;Kim, Jin-Sheon;Hong, Byeong-Hee;Kang, June-Gill;Cho, Guang-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.424-432
    • /
    • 2007
  • Luminance properties of external electrode fluorescent lamps and optical components in backlight unit (BLU) and optical transmission rates of optical sheets, are investigated for LCD-TV of 32" in diagonal with WXGA level resolution (1366$\times$768). The luminance is measured in 12-lamps and 18-lamps of BLU. The luminance uniformity preserves about 85 % in the 12-lamps backlight, while the luminance of optical components and the efficiency of backlight in the 12-lamps are lower than those in the 18-lamps backlight. When the lamp luminance in BLU having 12-lamps and 18-lamps is normalized as 100 %, the relative luminance of a diffusion plate, a diffusion sheet, a prism sheet (BEF), a polarization sheet (DBEF), has a constant value without dependence on a lamp luminance. The relative luminance of optical components in 12-lamps BLU is lower than that in 18-lamps backlight. The light transmission rate, the relative luminance of liquid crystal display panel with the luminance 100 % of backlight, is 7.14 % in the use of DBEF and BEF, 6.12 % in the use of only DBEF, and 3.21 % in the use of only BEF. Those Data obtained in this experiment for the lamps and optical components, are the design parameters for the LCD backlight.

A New Field Sequential Stereoscopic LCDs by use of Dual-Directional-Backlight

  • Yuuki, A.;Agari, M.;Iwsaki, N.;Sasagawa, T.;Tahata, S.;Satake, T.;Murakami, O.;Oda, K.;Ito, A.;Miyake, S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.255-258
    • /
    • 2004
  • We have developed the Scan-backlight Stereoscopic LCD that is a kind of field-sequential -Stereoscopic LCD combining the Dual-Directional-Backlight and the fast-response OCB panel. The Dual-Directional-Backlight using a double-sided prism sheet can change the direction of light by switching the LED light sources. The OCB panel using Feed-Forward Drive can realize frame rate of 120 Hz. As a result, the Scan-backlight Stereoscopic display works at its original resolving power, and produces flicker-free stereoscopic images. This auto stereoscopic display can resolved the problems of the double images and the pseudoscopic images in case of watching at oblique angles.

  • PDF

Average Droplet Size Distribution of a GDI Spray by Simultaneous Fluorescence/Scattering Image Technique (형과/산란광 동시 측정에 의한 GDI 분무의 평균 입경 분포에 관한 연구)

  • Gwak, Su-Min;Ryu, Gyeong-Hun;Choe, Dong-Seok;Kim, Deok-Jul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.868-875
    • /
    • 2001
  • The objective of this study is to investigate the average droplet size distributions of a GDI spray by simultaneous fluorescence/scattering image technique. GDI engine is recently very popular because of high engine efficiency and low emissions. However, the injectors must have good spray characteristics because the fuel is directly injected into the cylinder. The fuel mixtures used in this study were 2% of fluorobenzene, 9% of DEMA(diethyl-methyl-amine) and 89% of hexane by volume. The system for obtaining 2-D fluorescence/scattering images of fuel spray was constituted of a laser sheet, a doubling prism, optical filters, and an ICCD camera. Using the ratio of the fluorescence to the scattering intensities, SMD distributions were obtained. SMD measured by the technique was compared with that obtained by PDA. It was found that average droplet size was bigger at spray center in the early stage of injection and at the outer periphery of the spray in the late stage of injection.

A Study on the Flow Field Characteristics of Air Induction System for Reducing the Signal-to-Noise in the MAFS Output

  • Yoo, Seoung-Chool
    • Journal of ILASS-Korea
    • /
    • v.5 no.1
    • /
    • pp.49-57
    • /
    • 2000
  • This study presents the flow visualization results, velocity and turbulence intensity measurements made within an air filter cover and entry region of a mass air flow sensor (MAFS) which is used in an induction system of 3.8L engine. Flow structure in two air filter cover assemblies were examined. The first was a clear plastic replica of the production cover while the second was a modified clear plastic cover with a geometry configured to reduce fluctuations. High speed flow visualization and laser doppler velocimetry (LDV) systems were used to reveal and analyze the flow field characteristics encountered in the sensor design process under steady flow conditions. A 40-watt copper vapor laser was used as a light source. Its beam is focused down to a sheet of light approximately 1.5mm thick. The light scattered off the particles was recorded by a 16mm high speed rotating prism camera at 5000 frames per second. A comparison of the flow patterns and LDV measurements in the original and modified air filter covers is presented to illustrate the controlling effect of the cover design on the turbulence structure formation near the bypass and on the sensor output signal. In both axial and radial planes of the main passage it was found that the turbulence flow pattern is remarkably influenced by the air filter cover and main passage configuration.

  • PDF

A New Field Sequential Stereoscopic LCDs by use of Dual-Directional-Backlight

  • Yuuki, A.;Agari, M.;Iwsaki, N.;Sasagawa, T.;Tahata, S.;Satake, T.;Murakami, O.;Oda, K.;Ito, A.;Miyake, S.
    • Journal of Information Display
    • /
    • v.5 no.2
    • /
    • pp.6-9
    • /
    • 2004
  • We have developed the Scan-backlight Stereoscopic LCD that is a kind of field-sequential -Stereoscopic LCD combining the Dual- Directional- Backlight and the fast-response OCB panel. The Dual-Directional-Backlight using a double-sided prism sheet can change the direction of light by switching the LED light sources. The OCB panel using Feed-Forward Drive can realize frame rate of 120 Hz. As a result, the Scan-backlight Stereoscopic display works at its original resolving power, and produces flicker-free stereoscopic images. This auto- stereoscopic display can resolved the problems of the double images and the pseudoscopic images in case of watching at oblique angles.

Optimization of the Dual-layer LGP for Improving Luminance and Uniformity of Edge Type Back Light Unit (에지형 Back Light Unit의 휘도와 균일도 향상을 위한 복합도 광판 최적화)

  • Oh, Se-Won;Kim, Nam;Kim, Eun-Suk;An, June-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.6
    • /
    • pp.247-253
    • /
    • 2010
  • A dual-layer light guide plate (DLGP) was designed and a simulation was done to optimize the structure of the light guide plates used at backlight units while maintaining the luminance, uniformity and viewing angle by reducing the optical sheet. The characteristic of DLGP with prism pattern with curvature on the top surface is simulated and the luminance and uniformity are obtained. In order to improve the uniformity, the V groove prism pattern on the bottom surface was turned by an angle of $90^{\circ}$. In particular, we used the pitch calculation program to select the value of the ratio (Max : Min) between the pitch at the extreme outside and the pitch at the middle, the number of V groove lines and the variance at the bottom pattern of DLGP. After that, the optimum distance between V grooves was determined. For optimizing the DLGP, we examined the uniformity again by changing the number of pattern grooves on the bottom surface of DLGP. As a result of the simulation, we find that the BLU with DLGP has a uniformity of 90.6% and viewing angle $145^{\circ}$.