Search Result 983, Processing Time 0.027 seconds

Effect of the STereoLithography File Structure on the Ear Shell Production for Hearing Aids According to DICOM Images (DICOM 영상에 의한 STL 파일 구조가 보청기 이어 쉘 제작에 미치는 영향)

  • Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.121-126
    • /
    • 2017
  • A technique for producing the ear shell for a hearing aid using DICOM (Digital Imaging and Communication in Medicine) image and a 3D printing was studied. It is a new application method, and is an application technique that can improve the safety and infection of hearing aid users and can reduce the production time and process stages. In this study, the effects on the shape surface were examined before and after the printing of the ear shell using a 3D printer based on the values obtained from the raw data of the DICOM images at the volumes of 0.5 mm, 1.0 mm, and 2.0 mm, respectively. Before the printing, relative relationship was compared with respect to the STL (STereoLithography) file structure; and after the printing, the intervals of the layered structure of the ear shell shape surface were compared by magnifying them using a microscope. For the STL file structure, the numbers of triangular vertices, more than five intersecting points, and maximum intersecting points were large in the order of 0.5 mm, 1.0 mm, and 2.0 mm, respectively; and the triangular structure was densely distributed in the order of the bending, angle, and crest regions depending on the sinuosity of the external auditory meatus shape. As for the ear shell shape surface examined by the digital microscope, the interval of the layered structure was thick in the order of 2.0 mm, 1.0 mm, and 0.5 mm. For the STL surface structure mentioned above, the intersecting STL triangular structure was denser as the sinuosity of the 3D ear shell shape became more irregular and the volume of the raw data decreased.

Evaluation of the consistency and homogeneity of artificial latent fingerprint printed with artificial sweat (인공땀으로 출력한 인공지문의 균질성 평가)

  • Hong, Ingi;Hong, Sungwook
    • Analytical Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.26-32
    • /
    • 2015
  • The consistency and homogeneity of repetitive printing of artificial fingerprint were evaluated using a visual minutiae comparison method and an Automated Fingerprint Identification System (AFIS). The standard latent fingerprint pattern was prepared by the printing of a master digital fingerprint pattern with an inkjet printer cartridge case filled with artificial sweat. The master digital fingerprint pattern was prepared with a scanning of an inked fingerprint pattern of a living subject. The intensities of the master digital fingerprint pattern were adjusted by changing the 'output level' values of the Adobe Photoshop CS 5 software. Number of standard latent fingerprint patterns were printed and then developed with conventional latent fingerprint developing methods; ninhydrin treatment method and 1,2-indandion(1,2-IND)/$ZnCl_2$ treatment method. The ridge details of the latent fingerprint patterns developed with the reagents were visually compared with the inked fingerprint pattern and could confirm that the minutiae of both patterns are visually identical. The ridge detail of the inked fingerprint and reagent developed standard latent fingerprint patterns were compared with an AFIS. The average number of minutiae searched by the AFIS was $52.4{\pm}2.4$ (range = 48~56) for 50 ninhydrin developed latent fingerprint patterns, and $50.2{\pm}1.9$ (range = 47~53) for 50 1,2-IND/$ZnCl_2$ developed latent fingerprint patterns. These low standard deviation values over 50 repetitive printing demonstrated that the 50 standard latent patterns were printed with consistent and homogeneous manner.

Research on Continuous After-Treatment Process and System for DTP(Digital Textile Printing) (DTP(Digital Textile Printing)용 후처리 및 연속공정 시스템에 관한 연구)

  • Park, Soon-Young;Jeon, Dong-Won;Park, Yoon-Cheol;Lee, Beom-Soo;Cho, Hang-Sung
    • Journal of Fashion Business
    • /
    • v.15 no.5
    • /
    • pp.43-54
    • /
    • 2011
  • Digital Textile Printing(DTP) is appropriate for quick response system(QRS) and is closely connected with high value added fashion industry. Fashion products of high price are mainly silk and cotton. For high quality DTP products, it is important to optimize the parameters of media, pre and after-treatment, ink, printer, etc. DTP for these two fiber materials is also accompanied certainly with steaming as after-treatment process for coloration. Role of steam is like water in exhaustion dyeing. Steam can diffuse dye or ink in printing paste to fiber. Quality of DTP products depend on after-treatment processes such as steaming, washing, drying. Current production amount of DTP is smaller than one of conventional textile printing. However conventional after-treatment system has been using so far. This is mismatched with DTP in terms of process efficiency, spot work of small lot, quality control. In this study, continuous after-treatment system has been suitably designed for DTP that washing and drying are available after steaming. So, It is possible to improve efficiency of DTP process. Especially, the effects of after-treatment process, such as temperature of heat drum, steaming time on printability, color difference, color fastness were examined. Two types of samples(cotton knit and silk fabrics) were used. The results were obtained as follows : First, there is no a wide difference between the K/S values of cotton and silk treated with continuous after-treatment system and those of sample treated with conventional printing after-treatment method. So it is more effective to use the continuous after-treatment system than conventional printing after-treatment system in case of the daily throughput of 1,000 yards below. Second, after continuous after-treatment for DTP, K/S values were increased and lightness($L^*$) values were decreased. ${\Delta}E$ values were below 2.3. Third, DTP samples treated with continuous after-treatment system were tested for fastness(washing, light, rubbing). Grades of fastness(washing, light, rubbing) were above 3 grade.

Development of Auto-spray system to improve the quality of 3D Scanning Quality (3D 스캔 시 품질향상을 위한 스프레이 도포 자동화 장비 개발)

  • Kim, Wonseop;Jo, Jae Heung;Kim, Dongsu;Kim, Donggyoo;Hong, Seokmoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.100-105
    • /
    • 2016
  • The use of 3D scanners has increased gradually according to increasing 3D printer applications. The precision inspection of car parts or electronic components is an important issue not only in the field of mass production, but also in small-scale production. Recently, 3D scanner equipment efficiency and recognition technology has been improved continuously. On the other hand, the spraying time to prepare 3D scanning is time-consuming and has environmental problems. Therefore, an automatic spray system has been in demand by the manufacturing industry. Automatic spray equipment was newly developed for the preparation of a 3D scanner. In this research, the automatic spray system guarantees uniform spray operation. To determine the optimal spray parameters, various spraying methods, solutions and conditions were tested and compared with the experiments. The preparation time for 3D scanning was reduced to 1/10 compared to the manual spraying time, and indicates the optimal spraying conditions through a comparison of various spray coating conditions.

Identification of Korean Native Goat Meat using Amplified Fragment Length Polymorphism (AFLP) DNA Markers (Amplified Fragment Length Polymorphism (AFLP) DNA Marker를 이용한 한국 재래흑염소육 감별)

  • 정의룡
    • Food Science of Animal Resources
    • /
    • v.22 no.4
    • /
    • pp.301-309
    • /
    • 2002
  • This study was carried out to develop the breed-specific DNA markers for breed identification of Korean native goat meat using amplified fragment length polymorphism (AFLP)-PCR techniques. The genomic DNAs of Korean native goat, imported black goat and four dairy goat breeds(Saanen, Alpine, Nubian and Toggenburg) were extracted from muscle tissues or blood. Genomic DNA was digested with a particular combination of two restriction enzymes with 4 base(Mse I and Taq I) and 6 base(EcoR I and Hind III) recognition sites, ligated to restriction specific adapters and amplified using the selective primer combinations. In AFLP profiles of polyacrylamide gels, the number of scorable bands produced per primer combination varied from 36 to 74, with an average of 55.5. A total of 555 bands were produced, 149(26.8%) bands of which were polymorphic. Among the ten primer combinations, two bands with 2.01 and 1.26 kb in M13/H13 primer and one band with 1.65 kb in E35/H14 primer were found to be breed-specific AFLP markers in Korean native goat when DNA bands were compared among the goat breeds. In the E35/H14 primer combination, 2.19, 2.03, 0.96 and 0.87 kb bands detected in imported black goat, 2.13 kb band in Saanen breed and 2.08 kb band in Nubian breed were observed as breed-specific bands showing differences between goat breeds, respectively. The E35/H14 primer combination produced four DNA bands distinguished between Korean native goat and Saanen breed. The is study suggested that the breed specific AFLP bands could be used as DNA markers for the identification of Korean native goat meat from imported black goat and dairy goat meats.

An authentication service application using Context-awareness (상황인식 기법을 이용한 인증 서비스 응용)

  • Lee, Myung-jun;Lee, Tae-sik;Hong, Ho-jung;Hwang, Hyeon-seo;Oh, Young-jun;Lee, Kang-whan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.169-172
    • /
    • 2013
  • In this paper, we develop an application service of user authentication system using context awareness technology. The proposed security printer system service is applying 'NFC(Near Field Communication) technology', 'authentication system using communication with server, according to context awareness to application system. Our system extracts several context-awareness elements that happen through the user's printing with server communication. The proposed system property elements contain as print time, number of printing and name of document, etc. based on working memory operation as DB. This proposed system provide with context-awareness weight algorithm and analyzes the service which decides success or failure of user's printing. The develop app service is formed and applied when approved user who gets request. Approved user according to these context awareness tech will be provided with final service after authenticating again for the certain NFC card to reader. This results cab be contributed an authentication service based on context awareness weight algorithm and improved performance of management service in secure service applications.

  • PDF

The effectiveness of Cardiopulmonary Resuscitation training in elementary students (일부 초등학생의 심폐소생술교육의 효과)

  • Kim, Hee-Jung;Choi, Eun-Sook
    • The Korean Journal of Emergency Medical Services
    • /
    • v.11 no.2
    • /
    • pp.51-66
    • /
    • 2007
  • Purpose: With a view to providing basic data to develop cardiopulmonary resuscitation education suitable for elementary students, the cardiopulmonary resuscitation education was conducted to grasp students' knowledge, skills accuracy and the attitude change before and after the education. Methods: Convenience sampling was made on fourth and fifth graders(total-35 students) of S elementary school located in K city, Chungcheongnam-do, and this was a pre-experiment research designed before and after choosing a single group. In terms of methods, specifically we, researchers ; 1) Handed out questionnaires to students directly to make them fill in firsthand and collected the questionnaires. 2) Utilized PPT materials based on 2005 AHA guideline and DVD materials of AHA, to give students theoretical education of cardiopulmonary resuscitation. We used Anne/SkillReporter$^{(R)}$ torso produced by Leardal Inc, and Little Anne to conduct practical education individually. 3) Asked students to give Anne/SkillReporter$^{(R)}$ torso cardiopulmonary resuscitation five times with the ratio of 30 : 2, and then one of researchers filled in the evaluation sheet individually. 4) Evaluated the accuracy of students' ability to perform the resuscitation based on the record of Anne/SkillReporter$^{(R)}$ integrated printer(which was the objective tool to grasp students' skills accuracy). 5) Gave out questionnaires to make students fill them in and then collected them. after completing the practical evaluation. Results: 1) In case of the attitude about cardiopulmonary resuscitation, Students' confidency rose from 19.28%(before the education) to 93.57(after the education)- which is a positive change. 2) As the result of the education, some elementary students scored 11 points (full score-16 points), up from 5 points before the education, in terms of the knowledge about cardiopulmonary resuscitation. The average point also reached 13.14 points(after the education), jump from 8.37(before the education), which was the rise of 29.8%. 3) When it comes to the practical performance, the skills accuracy was 80.93% on average, and the calculation method was as follows: total items were 16, and each item was marked form 0 to 2 points, meaning the full score was 32 points. The minimum score was 19 points and the maximum was 32($M{\pm}SD=25.90{\pm}2.88$), which was calculated based on percentage. 4) Regarding skills accuracy, respiration accuracy(%)($M{\pm}SD=30.20{\pm}27.16$) was higher than pressure accuracy(%) ($M{\pm}SD=15.34{\pm}25.27$). Conclusion: The result showed that students' attitude on cardiopulmonary resuscitation changed positively. and meaningful difference(p = .00) existed in the change of students' knowledge. In terms of skills accuracy. chest compression and airway control showed high accuracy, but the result of Anne/SkillReporter$^{(R)}$ performance showed that the accuracy of chest compression was lower than that of mouth-to-mouth resuscitation.

  • PDF

Novel condylar repositioning method for 3D-printed models

  • Sugahara, Keisuke;Katsumi, Yoshiharu;Koyachi, Masahide;Koyama, Yu;Matsunaga, Satoru;Odaka, Kento;Abe, Shinichi;Takano, Masayuki;Katakura, Akira
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.4.1-4.4
    • /
    • 2018
  • Background: Along with the advances in technology of three-dimensional (3D) printer, it became a possible to make more precise patient-specific 3D model in the various fields including oral and maxillofacial surgery. When creating 3D models of the mandible and maxilla, it is easier to make a single unit with a fused temporomandibular joint, though this results in poor operability of the model. However, while models created with a separate mandible and maxilla have operability, it can be difficult to fully restore the position of the condylar after simulation. The purpose of this study is to introduce and asses the novel condylar repositioning method in 3D model preoperational simulation. Methods: Our novel condylar repositioning method is simple to apply two irregularities in 3D models. Three oral surgeons measured and evaluated one linear distance and two angles in 3D models. Results: This study included two patients who underwent sagittal split ramus osteotomy (SSRO) and two benign tumor patients who underwent segmental mandibulectomy and immediate reconstruction. For each SSRO case, the mandibular condyles were designed to be convex and the glenoid cavities were designed to be concave. For the benign tumor cases, the margins on the resection side, including the joint portions, were designed to be convex, and the resection margin was designed to be concave. The distance from the mandibular ramus to the tip of the maxillary canine, the angle created by joining the inferior edge of the orbit to the tip of the maxillary canine and the ramus, the angle created by the lines from the base of the mentum to the endpoint of the condyle, and the angle between the most lateral point of the condyle and the most medial point of the condyle were measured before and after simulations. Near-complete matches were observed for all items measured before and after model simulations of surgery in all jaw deformity and reconstruction cases. Conclusions: We demonstrated that 3D models manufactured using our method can be applied to simulations and fully restore the position of the condyle without the need for special devices.

Colorization Algorithm Using Wavelet Packet Transform (웨이블릿 패킷 변환을 이용한 흑백 영상의 칼라화 알고리즘)

  • Ko, Kyung-Woo;Kwon, Oh-Seol;Son, Chang-Hwan;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • Coloriztion algorithms, which hide color information into gray images and find them to recover color images, have been developed recently. In these methods, it is important to minimize the loss of original information while the color components are embedded and extracted. In this paper, we propose a colorization method using a wavelet packet transform in order to embed color components with minimum loss of original information. In addition, the compensation processing of color saturation in the recovered color images is achieved. In the color-to-gray process, an input RGB image is converted into Y, Cb, and Cr images, and a wavelet packet transform is applied to the Y image. After analyzing the amounts of total energy for each sub-band, color components are embedded into two sub-bands including minimum amount of energy on the Y image. This makes it possible not only to hide color components in the Y image, but to recover the Y image with minimum loss of original information. In the gray-to-color process, the color saturation of the recovered color images is decreased by printing and scanning process. To increase color saturation, the characteristic curve between printer and scanner, which can estimate the change of pixel values before and after printing and scanning process, is used to compensate the pixel values of printed and scanned gray images. In addition, the scaling method of the Cb and Cr components is applied to the gray-to-color process. Through the experiments, it is shown that the proposed method improves both boundary details and color saturation in the recovered color images.

A Study on the Development of Urine Analysis System using Strip and Evaluation of Experimental Result by means of Fuzzy Inference (스트립을 이용한 요분석시스템의 개발과 퍼지추론에 의한 검사결과 평가에 관한 연구)

  • Jun, K. R.;Lee, S. J.;Choi, B. C.;An, S. H.;Ha, K.;Kim, J. Y.;Kim, J. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.477-486
    • /
    • 1998
  • In this paper, we implemented the urine analysis system capable of measuring a qualitative and semi-quantitative and assay using strip. The analysis algorithm of urine analysis was adopted a fuzzy logic-based classifiers that was robust to external error factors such as temperature and electric power noises. The spectroscopic properties of 9 pads In a strip were studied to developing the urine analysis system was designed for robustnesss and stability. The urine analysis system was consisted of hardware and software. The hardware of the urine analysis system was based on one-chip microprocessor, and Its peripherals which composed of optic modulo, tray control, preamplifier, communication with PC, thermal printer and operating status indicator. The software of the urine analysis system was composed of system program and classification program. The system program did duty fort system control, data acquisition and data analysis. The classification program was composed of fuzzy inference engine and membership function generator. The membership function generator made triangular membership functions by statical method for quality control. Resulted data was transferred through serial cable to PC. The transferred data was arranged and saved be data acquisition program coded by C+ + language. The precision of urine analysis system and the stability of fuzzy classifier were evaluated by testing the standard urine samples. Experimental results showed a good stability states and a exact classification.

  • PDF