• Title/Summary/Keyword: Primary pressure

검색결과 1,069건 처리시간 0.022초

고압실 형상에 따른 환형 제트펌프의 특성 (The Effect of High Pressure Chamber's Shape on the Characteristics of Annular Jet Pump)

  • 권오붕
    • 수산해양기술연구
    • /
    • 제35권4호
    • /
    • pp.428-434
    • /
    • 1999
  • Experimental studies on the characteristics of annular jet pump were carried out in this paper. Jet pump can be used widely for the transportation of solid materials, farm produce and fishes. The effects of high pressure chamber on the characteristics of annular jet pump were sought in this paper. Experiments were done for three shapes of high pressure chamber, and for several lengths of the high pressure chamber. Three types of the high pressure chamber's entrances($90^{\circ}$ single inflow, $45^{\circ}$single inflow, and $45^{\circ}$ double inflow) were tested. Water was used for both the primary fluid and secondary fluid. The results obtained in this study are as follows; $45^{\circ}$double inflow type is the most effective among the tested three types of the high pressure chamber's entrances. The efficiency of jet pump with 400mm of high pressure chamber length is the highest among the chamber lengths tested in this study, thus indicating appropriate chamber length is required to get an efficient.

  • PDF

화력 발전용 보일러 덕트-홴 시스템의 진동현상에 대한 연구 : 입구측 와류에 의한 과대진동 사례 (A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers : Inlet Vortex Induced Excessive Vibration)

  • 김철홍;주영호
    • 한국소음진동공학회논문집
    • /
    • 제13권3호
    • /
    • pp.194-201
    • /
    • 2003
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in a fan-duct system of fossil fueled boilers. We measured static pressure variation (pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this Paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

고압실 형상에 따른 환형 제트펌프의 특성 (The Effect of High Pressure Chamber's Shape on the Characteristics of Annular Jet Pump)

  • 김명관;권오붕
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.75-81
    • /
    • 2000
  • Experimental studies on the characteristics of annular jet pump were carried out in this paper. The effects of high pressure chamber on the characteristics of annular jet pump were sought in this paper. Experiments were done for three shapes of high pressure chamber, and for several lengths of the high pressure chamber. Three types of the high pressure chamber's entrances($90^{\circ}$ single inflow, $45^{\circ}$ single inflow, and $45^{\circ}$ double inflow) were tested. Water was used for both the primary fluid and secondary fluid. The results obtained in this study are as follows; $45^{\circ}$ double inflow type is the most effective among the tested three types of the high pressure chamber's entrances. The efficiency of jet pump with 400mm of high pressure chamber length is the highest among the chamber lengths tested in this study, thus indicating appropriate chamber length is required to get an efficient jet pump.

  • PDF

Inlet Cone Vortex에 의한 500 MW급 발전용 보일러 홴-덕트 시스템의 과대진동 (Excessive Vibration of the Fan-duct Systems in 500 MW Power Plant Boilers Due to Inlet Cone Vortex)

  • 김철홍;주영호;변형현
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.116-121
    • /
    • 2000
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in the fan-duct systems of fossil fueled boilers. We measured static pressure variation(pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure Pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

  • PDF

Water-Entry Induced Cavity Pressure

  • Lee, Min-Hyung
    • Journal of Mechanical Science and Technology
    • /
    • 제14권5호
    • /
    • pp.562-568
    • /
    • 2000
  • The pressure in a water-entry induced cavity, is analyzed up to the closed cavity (bubble). Water-entry is a highly transient phenomenon, and the evolution of the water-entry cavity must be explained by considering the entry speed, shape of the solid body, atmosphere pressure, and cavity pressure as the primary variables. This work is an extension of the cavity dynamics model recently reported by Lee (l997a). To extend the model for a wide range of entry speeds the cavity pressure is calculated from a one-dimensional quasi-steady flow model. The estimation of the cavity pressure allows us to explain the experimentally observed surface closure phenomena at low entry speeds. Predictions for the time of surface closure are compared with the published experimental data.

  • PDF

화력 발전용 보일러 Duct/Fan 시스템의 진동현상에 대한 연구 : Inlet Vortex에 의한 과대진동 사례 (A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers: Inlet Vortex Induced Excessive Vibration)

  • 김철홍;주영호;변형현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.82-87
    • /
    • 2000
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in the fan-duct systems of fossil fueled boilers. We measured static pressure variation(pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

  • PDF

인공위성 카메라 주반사경의 위상 최적화 (Topology Optimization of the Primary Mirror of a Multi-Spectral Camera)

  • 박강수;장수영;이응식;윤성기
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.920-925
    • /
    • 2001
  • A study on the topology optimization of a multi-spectral camera for space-use is presented. A multi-spectral camera for space-use experiences degradation of optical image in the space, which can not be detected on the optical test bench on the earth. An optical surface deformation of a primary mirror, which is a principal component of the camera system, under the self-weight loading is an important factor affecting the optical performance of the whole camera system. In this study, topology optimization of the primary mirror of the camera is presented. Total mass of the primary mirror is given as a constraint to the optimization problem. The sensitivities of the objective function and constraint are calculated by direct differentiation method. Optimization procedure is carried out by an optimality criterion method using the sensitivities of the objective function and the constraint. As a preliminary example, topology optimization considering a self-weight loading is treated. For practical use, the polishing pressure is included as a loading in the topology optimization of the primary mirror. Results of the optimized design topology for the primary mirror with varying mass ratios are presented.

  • PDF

The influence of internal ring beams on the internal pressure for large cooling towers with wind-thermal coupling effect

  • Ke, Shitang;Yu, Wei;Ge, Yaojun;Zhao, in;Cao, Shuyang
    • Wind and Structures
    • /
    • 제28권1호
    • /
    • pp.1-17
    • /
    • 2019
  • Internal ring beams are primary components of new ring-stiffened cooling towers. In this study, numerical simulation of the internal flow field of a cooling tower with three ring beams under wind-thermal coupling effect is performed. The studied cooling tower is a 220-m super-large hyperbolic indirect natural draft cooling tower that is under construction in China and will be the World's highest cooling tower, the influence of peripheral radiators in operating cooling tower is also considered. Based on the simulation, the three-dimensional effect and distribution pattern of the wind loads on inner surface of the cooling tower is summarized, the average wind pressure distributions on the inner surface before and after the addition of the ring beams are analyzed, and the influence pattern of ring beams on the internal pressure coefficient value is derived. The action mechanisms behind the air flows inside the tower are compared. In addition, the effects of internal ring beams on temperature field characteristics, turbulence kinetic energy distribution, and wind resistance are analyzed. Finally, the internal pressure coefficients are suggested for ring-stiffened cooling towers under wind-thermal coupling effect. The study shows that the influence of internal stiffening ring beams on the internal pressure and flow of cooling towers should not be ignored, and the wind-thermal coupling effect should also be considered in the numerical simulation of cooling tower flow fields. The primary conclusions presented in this paper offer references for determining the internal suction of such ring-stiffened cooling towers.

오리피스 노즐 수직 2 상 유동의 물질전달 특성 (Mass Transfer Characteristics of Vertical Two-Phase Flows with Orifice Nozzle)

  • 김동준;양희천
    • 대한기계학회논문집B
    • /
    • 제39권10호
    • /
    • pp.817-824
    • /
    • 2015
  • 본 논문은 수직 오리피스 노즐의 유동 및 물질전달 특성에 대한 실험적 연구를 목적으로 한다. 구동유체 및 부유체의 유량, 용존산소 농도 그리고 소비 전력을 측정하였으며, 고속 카메라를 이용한 직접 촬영 기법으로 수직 혼합유동의 가시화 이미지를 획득하였다. 측정자료를 이용하여 질량비, 총괄 산소전달 계수 그리고 물질전달 성능계수를 도출하였다. 구동압력이 증가하면 질량비는 약간 감소하는 반면에, 산소전달 계수와 소비전력은 증가하였다. 구동압력이 증가하고 질량비가 작아지면, 기포의 미세화가 촉진되고 확산도가 증대되기 때문에 산소 전달율이 증가하였다.

지상용 가스터빈 주동력장치(PPU) 연소기의 개발과 시험평가 (Development and Test of Gas Turbine Combustor for Ground Vehicle PPU(Primary Power Unit))

  • 이동훈;이강엽;전승배;양수석;고영성;최성만
    • 한국항공우주학회지
    • /
    • 제33권8호
    • /
    • pp.111-121
    • /
    • 2005
  • 지상용 장비의 주 동력원으로 사용할 수 있는 출력 100kW급 가스터빈 엔진의 연소기를 개발하여 시험하였다. 이를 위해 환형역류형 연소기와 압력선회식 연료노즐을 채택하였고, 1차원 설계와 3차원 열, 유동해석을 통하여 연소기 설계를 수행하였으며, 연료노즐 시험, 연소기 리그 시험 등을 통하여 개발된 연소기의 성능을 확인하였다. 개발된 연소기를 엔진에 장착하여 각종 환경시험을 수행한 결과, 연소기 저온 점화성능, 내구 성능 등에서 만족할 만한 결과를 도출하였으며, 개발된 연소기는 지상용 주 동력장치에 성공적으로 적용되었다.