• 제목/요약/키워드: Primary energy supply

검색결과 115건 처리시간 0.025초

High-Efficiency Non-contact Power Supply System

  • Zheng, Bin;Kwan, Dae-Hwan;Lee, Dae-Sik
    • 한국정보기술응용학회:학술대회논문집
    • /
    • 한국정보기술응용학회 2005년도 6th 2005 International Conference on Computers, Communications and System
    • /
    • pp.233-235
    • /
    • 2005
  • Non-contact power supply (NCPS), as a clean and safe energy supply concept has been applying wildly. Comparing with the conventional transformer the non-contact transformer has a large air gap between the long primary winding and the secondary winding. Due to it, the non-contact transformer has increased leakage inductance and reduced magnetizing inductance. So the high frequency series resonant converter has been widly used on the non-contact power supply system for transferring the primary power to the secondary one, from what a high influence voltage can be gained on the secondry coil even though the large air gap exists. However, it still has the disadvantages of the load sensitive voltage gain characteristics when load is changing. In this paper, we propose a fuzzy logic controller to adjust the frequency of the inverter to track the resonat which is changing when the load is change.

  • PDF

통합수요관리 효과분석을 위한 한국형 Energy System Management 모형 개발에 관한 연구 (A study on Development of Korean - Energy System Management Model for Effect Analysis of Integrated Demand Management)

  • 김용하;조현미;김의경;유정희;김동근;우성민
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1103-1111
    • /
    • 2011
  • This paper is developed to Energy Balance Flow show the flow of total energy resource be used nationally. The Energy Balance Flow is applicable of demand management factor through the analysis of foreign energy model of supply and demand and energy statistic data in the country. This study is based on and developed to Energy system management model is able to appraisal efficient of energy cost cutting, CO2 emission reduction and Energy saving at the national level calculated effect reached amount of primary energy to change of energy flow followed application of demand side management factor is able to appraisal quantitatively at the total energy to model of demand and supply.

Energy Balance Flow 구축에 의한 에너지효율향상 효과분석 (Effect Analysis on Energy Efficiency Improvement for Establishing Energy Balance Flow)

  • 김용하;조현미;신형철;김형중;우성민;김영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.679-680
    • /
    • 2011
  • This paper is developed to Energy Balance Flow show the flow of total energy resource be used nationally. The Energy Balance Flow is applicable of demand management factor through the analysis of foreign energy model of supply and demand and energy statistic data in the country. This study is based on and developed to Energy system management model is able to appraisal efficient of energy cost cutting, CO2 emission reduction and Energy saving at the national level calculated effect reached amount of primary energy to change of energy flow followed application of demand side management factor is able to appraisal quantitatively at the total energy to model of demand and supply.

  • PDF

$\cdot$병렬 공진형컨버터를 이용한 비접촉전원 (Contact-less Power Supply Using Series-Parallel Rasonant Converter)

  • 김은수;구대현;김종무;강도현;신병철;공영수;양승철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.103-107
    • /
    • 2002
  • A contact-less power supply system (CPS) allows electrical energy to supply to mobile consumers without any electrical or mechanical contact. CPS works in the same principle as a transformer, with the track litz cable forming the primary circuit and the pickup as the secondary. The track power supply generates the high frequency alternating current in the track cable. The captured AC magnetic field generated by the track conductors produces electrical energy in the pickup coil and the pickup rectifier converts the high frequency AC power to DC while regulating the power to the load. This paper presents the theoretical analysis, simulation and experiment리 results of the series-parallel resonant converter working as contact-less power supply system.

  • PDF

지니계수를 이용한 시군구별 신재생에너지 자원의 불균등성 분석 (Analysis of the Regional Inequalities of Renewable Energy Resources using Gini's Coefficients)

  • 이지민
    • 농촌계획
    • /
    • 제22권2호
    • /
    • pp.109-119
    • /
    • 2016
  • Most of countries are trying to increase the supply of renewable energy as the substitute of the fossil energy for reducing greenhouse gas emissions. However, renewable energy sources account for only about 3.86% of the total Korea primary energy supply. To increase the rate of renewable energy in Korea's energy consumption, various policies for expanding the use of renewable energy should be applied. Also these policies should be consider renewable energy resources distribution and regional inequality. In this study, the potentials of photovoltaic, wind power and bioenergy from rice straw, livestock waste and food waste are calculated and the distribution characteristic and regional inequalities are analyzed using Gini's coefficient and Gini decomposition method. As the results, technical potentials of photovoltaic and wind power of city region(Gu) has more potential rate than theoretical potentials. Livestock waste has the most unequal distribution (Gini's coefficient: 0.617) among renewable resources.

연못 생태계의 영양구조와 에너지 유전 (Trophic Structure and Energy Flow of a Pond Ecosystem)

  • 정연숙
    • Journal of Plant Biology
    • /
    • 제25권3호
    • /
    • pp.123-133
    • /
    • 1982
  • The tropic structure and the function of a small pone ecosystem under the tree stand were studied in terms of energy flow. About 28% of total solar radiation was intercepted by the tree canopy over the pond. Primary producers converted 1.1%(3,382 kcal$\cdot$$m^{-2}$$\cdot$$y^{-1}$) of solar radiation (320,000 kcal$\cdot$$m^{-2}$$\cdot$$y^{-1}$) into gross primary production. The amount of energy availble to the pond snail was 1,683 kcal.m-2.y-1 of the net production by primary producers and 1,033 kcal$\cdot$$m^{-2}$$\cdot$$y^{-1}$ of the litter fallen into the pond. The amount of gross secondary production by the pond snail was 245 kcal$\cdot$$m^{-2}$$\cdot$$y^{-1}$. Judging from these, supply of both net primary production and the litter was indispensable for the maintenance of the pond ecosystem. The total amont of energy as gross primary production plus litter was 4,415 kcal$\cdot$$m^{-2}$$\cdot$$y^{-1}$(100%). Since the total respiration loss was calculated to be 1,917 kcal$\cdot$$m^{-2}$$\cdot$$y^{-1}$(43.4%), the rate of energy accumulation in the pond estimated to 56.6%.

  • PDF

Comments on "Optimal Utilization of a Cognitive Shared Channel with a Rechargeable Primary Source Node"

  • El Shafie, Ahmed;Salem, Ahmed Sultan
    • Journal of Communications and Networks
    • /
    • 제17권3호
    • /
    • pp.265-266
    • /
    • 2015
  • In a recent paper [1], the authors investigated the maximum stable throughput region of a network composed of a rechargeable primary user and a secondary user plugged to a reliable power supply. The authors studied the cases of an infinite and a finite energy queue at the primary transmitter. However, the results of the finite case are incorrect. We show that under the proposed energy queue model (a decoupled M/D/1 queueing system with Bernoulli arrivals and the consumption of one energy packet per time slot), the energy queue capacity does not affect the stability region of the network.

Optimal installation of electric vehicle charging stations connected with rooftop photovoltaic (PV) systems: a case study

  • Heo, Jae;Chang, Soowon
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.937-944
    • /
    • 2022
  • Electric vehicles (EVs) have been growing to reduce energy consumption and greenhouse gas (GHG) emissions in the transportation sector. The increasing number of EVs requires adequate recharging infrastructure, and at the same time, adopts low- or zero-emission electricity production because the GHG emissions are highly dependent on primary sources of electricity production. Although previous research has studied solar photovoltaic (PV) -integrated EV charging stations, it is challenging to optimize spatial areas between where the charging stations are required and where the renewable energy sources (i.e., solar photovoltaic (PV)) are accessible. Therefore, the primary objective of this research is to support decisions of siting EV charging stations using a spatial data clustering method integrated with Geographic Information System (GIS). This research explores spatial relationships of PV power outputs (i.e., supply) and traffic flow (i.e., demand) and tests a community in the state of Indiana, USA for optimal sitting of EV charging stations. Under the assumption that EV charging stations should be placed where the potential electricity production and traffic flow are high to match supply and demand, this research identified three areas for installing EV charging stations powered by rooftop PV in the study area. The proposed strategies will drive the transition of existing energy infrastructure into decentralized power systems. This research will ultimately contribute to enhancing economic efficiency and environmental sustainability by enabling significant reductions in electricity distribution loss and GHG emissions driven by transportation energy.

  • PDF

서울지역 고등학교 건물의 에너지소비특성에 관한 사례분석 (A Case Study for Energy Consumption Characteristics of High School Facilities in Seoul)

  • 김성범;오병칠;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제36권6호
    • /
    • pp.61-69
    • /
    • 2016
  • In this study, we analyzed five-year(2011~2015) data for D high school in Seoul area to analyze energy consumption characteristics in high school. The results are summarized as follows. (1) In the result of comparison analysis about 2015 energy consumption by usage, based on primary energy, 18% of energy was consumed in cafeteria, and 82% was consumed in main building. In the case of main building, base and constant load excepting hot water supply in restroom took 40%, heating including freeze protection took 20%, hot water supply in restroom took 14%, and cooling took 8% in order. (2) In the 2015 total energy consumption in D high school based on primary energy, heating energy takes 28%. The range and limit of energy savings coming from the reinforcement of insulation and window performance could be estimated. (3) To introduce new & renewable energy system in high school, electricity-based system is suitable than heat-based system because usage of electric energy is larger than that of heat energy in high school. (4) Five-year energy consumption unit according to heating degree-day showed a linearly increasing trend, and the coefficient of determination(R2) was 0.9763, which means high correlation.

자원수급(資源需給)의 세계적(世界的)인 추세(趨勢)와 우리나라의 동향(動向) -국내자원(國內資源)의 유효이용(有效利用)을 위한 처리(處理) 및 회수기술(回收技術) 동향조사(動向調査)(1)- (Worldwide Trend and Korean Recent Status in the Supply-Demand for Resources -The Current Situation of Recycling Technology for Waste Resources in Korea(1)-)

  • 오재현;김미성;조성백
    • 자원리싸이클링
    • /
    • 제15권3호
    • /
    • pp.3-19
    • /
    • 2006
  • 본 연구에서는 우리나라 미이용 자원의 유효이용 즉, 리싸이클링의 동향을 조사하기에 앞서 다양한 자원의 전체현황을 파악하려고 노력하였다. 그러기 위해서 자원수급의 세계적인 추세를 논하였고, 우리나라와 비교 검토하기 위해서 일본의 주요금속의 머티리얼 흐름을 조사하였다. 끝으로 우리나라 금속자원, 에너지자원 및 광물자원의 수급동향을 탐색, 고찰하였다.