• 제목/요약/키워드: Primary control

검색결과 3,244건 처리시간 0.026초

쌍생아(雙生兒) 치아(齒牙) 우식증(齲蝕症)에 관(關)한 역학적(疫學的)인 연구(硏究) (EPIDEMIOLOGICAL STUDY ON DENTAL CARIES IN TWINS.)

  • 정태련
    • 대한소아치과학회지
    • /
    • 제1권1호
    • /
    • pp.57-61
    • /
    • 1974
  • The Study reported here was designed to analyze the prevalence of Dental Caries in the primary teeth of monozygote twins, and to ascertain and compare the intrapair differences with the intrapair differences in control pairs. The prevalence of dental caries in the primary teeth of 40 pairs of presumably monozygote twins, based on phenotypic analysis, was studied. The age range was from 3 to12 years. The control group consisted of pairs that included a twin chosen at random and an unrelated child of the same sex and age, so that for each pair of twins there was a corresponding control pair. The clinical examination was carried out by an operator using an oral mirror and sharp explorers, and with good lighting. 40 pairs of twins were examined with a total of 4,950 primary tooth surfaces (990 primary teeth) and 40 control pairs with a total of 4,935 primary tooth surfaces (987 primary teeth). Five surfaces were considered for each tooth. After the def individual index was determined, the ratio between this index and the number of examined surfaces was established in each case, the cer (Caries experience rate) index. The def and cer averages were determined for the subjects and the controls. All intrapair differences in twin and control groups were compared following the paired sampling method. The following conclusions were made: 1. Intrapair differences in the control group were significantly greater than in twins, when defs, ds, es, fs, and cer were compared. 2. The genotype appeared to be a determining factor in dental caries susceptibility or resistance, although the environment played an important role as well. 3. Intrapair differences in American children were significantly greater than in Korean when defs, es, fs, and cer were compared, but ds was equal.

  • PDF

The Effect of Enzyme/Microbial Additive on Anaerobic Digestion of Primary Sludge

  • Kim, Hyung-Jin;Song, Chang-Soo;Kim, Dong-Wook;Pagilla, Kishna-R.
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제10권S_1호
    • /
    • pp.35-40
    • /
    • 2001
  • Effect of the addition of an enzyme/microbial additive(EMA) to enhance anaerobic digestion of the primary sludge was investigated. Two laboratory scale anaerobic digester were operated with primary sludge taken from a municipal wastewater treatment plant. The digester receiving EMA with the sludge feed performed better than the control digester, when both were operated at 10-days and 15-days Solid Retention Time(SRT). Addition of EMA to the experimental digester provided 7%(10-days SRT) and 16%(15-days SRT) higher gas production compared to the control digester when both were fed with the same amount of volatile solids. The reduction in volatile solids was 24% better in the experimental digester compared to the control ar 10-days SRT, and the improvement 10% at 15-day SRT. Improvement in COD reduction, and fecal coliform density reduction were also seen in the experimental digester due to EMA addition compared to the control both ar 10-days SRT and 15-day SRT operation. Preliminary cost benefit analysis for a wastewater treatment plant showed that approximately $115/day in gas production improvements can be realized upon addition of EMA to primary sludge anaerobic digesters operating at 10-day SRT. The value of increased gas production was $172/day if the same digesters are operated with EMA addition at 15-day SRT.

  • PDF

An Experimental Study of the Trust Vector Control Using Counterflow Concept

  • C. M. Lim;Kim, H. D.;Lee, K. H.;T. Setoguchi
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.192-197
    • /
    • 2004
  • Recently, fluidic thrust vectoring methods have been preferably employed to control the movement of propulsive systems due to relatively simpler design and lower cost than mechanical thrust vectoring methods. For An application of the thrust vectoring to flight bodies, it is necessary to understand very complicated exhaust flows which are often subject to shock waves and boundary layer separation. But researches for the thrust vector control using counterflow have been few. In the present study, experiments have been performed to investigate the characteristics of supersonic jets controlled by a thrust vectoring method using counterflow. The primary jet is expanded through a two-dimensional primary nozzle shrouded by collars, and is deflected by the suction of the air near nozzle into an upper slot placed between the primary nozzle and the upper collar. A shadowgraph method is used to visualize the supersonic jet flowfields. Primary nozzle pressure ratios and suction nozzle pressure ratios are varied from 3.0 to 5.0, and from 0.2 to 1.0 respectively. The present experimental results showed that, for a given primary nozzle pressure ratio, a decrease in the suction nozzle pressure ratio produced an increased thrust vector angle. As the suction nozzle pressure ratios were increased and decreased, the hysteresis of the thrust vectoring was observed through the wall pressure distributions

  • PDF

주파수추종서비스 제공을 위한 다수 배터리전기저장장치(BESS)의 통합제어 전략 (Integrated Control Strategy of Multiple BESS for providing Primary Frequency Control)

  • 유가람;최우영;국경수
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1169-1175
    • /
    • 2016
  • As an Increased penetration level of renewable resources has caused concerns about primary frequency response, an increase in BESS(Battery Energy Storage System) capacity has been expected because of its fast response to the disturbances in the power system. This paper proposes the Integrated Control Strategy of multiple BESS for effectively providing the primary frequency control in the bulk power systems by coordinating the response, SOC and its recovery of BESS. The proposed strategy prevents multiple BESS from providing exceeding response and keeps the balance between SOC of multiple BESS. In addition, It would recover the SOC of BESS efficiently. The effectiveness of the proposed strategy is verified through various case studies employing Korean power system.

가변구조제어에 의한 조준경 고각 안정화 (Stabilization of elevation for gunner primary sight using variable structure control)

  • 김중완;이정규;김주상;이만형
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.643-647
    • /
    • 1990
  • Gunner primary sight(GPS) stabilization system lays line of sight(LOS) to find out a target and transmits informations to the fire control system (FCS). In a moving vehicle, accuracy of LOS and FCS depends on the design of GPS and servomechanism system. The heavy vibration of vehicle on the severe off-road environment degenerates the stabilization capability of GPS. In this study, to stabilize of elevation for GPS using the variable structure control, we derived the dynamic equation of GPS system and designed the variable structure controller. Computer simulation results fulfilled the static and dynamic stability of GPS using the variable structure control.

  • PDF

Transition over 35 Years in the Incidence Rates of Primary Central Nervous System Tumors in Shanghai, China and Histological Subtyping Based on a Single Center Experience Spanning 60 Years

  • Shen, Fang;Wu, Chun-Xiao;Yao, Yu;Peng, Peng;Qin, Zhi-Yong;Wang, Yin;Zheng, Ying;Zhou, Liang-Fu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권12호
    • /
    • pp.7385-7393
    • /
    • 2013
  • Background: Only few epidemiological data on primary central nervous system (CNS) tumors in Shanghai have been reported. Methods: All cases of primary CNS tumors that were registered at Center for Disease Control and Prevention (CDC) were collected (1973-2007: urban Shanghai; 2003-2007: whole Shanghai city). Trends were analyzed using joinpoint analysis and rates were stratified by age, gender and region. Histological data were collected from both CDC and Huashan Hospital. Results: From 1973 to 2007, the five-year average incidence rate in urban Shanghai increased in both genders, especially in the elderly population. Joinpoint analysis showed the age-adjusted incidence rate for males increased first but then plateaued, whilst rates for females continued increasing over the 35 years. For the five-year status quo (2003-2007), rural had a higher age-adjusted incidence rate than urban populations, and females higher than males, especially those with advanced age. According to CDC (2003-2007) and Huashan Hospital (1951-2011), the two most common histological subtypes were neuroepithelial tumors (with male predominance) and meningiomas (with female predominance). Conclusions: In Shanghai, a steadily increased incidence rate of primary CNS tumors was observed in general, and in the elderly and female population in particular.

Grid-friendly Control Strategy with Dual Primary-Side Series-Connected Winding Transformers

  • Shang, Jing;Nian, Xiaohong;Chen, Tao;Ma, Zhenyu
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.960-969
    • /
    • 2016
  • High-power three-level voltage-source converters are widely utilized in high-performance AC drive systems. In several ultra-power instances, the harmonics on the grid side should be reduced through multiple rectifications. A combined harmonic elimination method that includes a dual primary-side series-connected winding transformer and selective harmonic elimination pulse-width modulation is proposed to eliminate low-order current harmonics on the primary and secondary sides of transformers. Through an analysis of the harmonic influence caused by dead time and DC magnetic bias, a synthetic compensation control strategy is presented to minimize the grid-side harmonics in the dual primary side series-connected winding transformer application. Both simulation and experimental results demonstrate that the proposed control strategy can significantly reduce the converter input current harmonics and eliminates the DC magnetic bias in the transformer.

Primary Current Generation for a Contactless Power Transfer System Using Free Oscillation and Energy Injection Control

  • Li, Hao Leo;Hu, Aiguo Patrick;Covic, Grant Anthony
    • Journal of Power Electronics
    • /
    • 제11권3호
    • /
    • pp.256-263
    • /
    • 2011
  • This paper utilizes free oscillation and energy injection principles to generate and control the high frequency current in the primary track of a contactless power transfer system. Here the primary power inverter maintains natural resonance while ensuring near constant current magnitude in the primary track as required for multiple independent loads. Such energy injection controllers exhibit low switching frequency and achieve ZCS (Zero Current Switching) by detecting the high frequency current, thus the switching stress, power losses and EMI of the inverter are low. An example full bridge topology is investigated for a contactless power transfer system with multiple pickups. Theoretical analysis, simulation and experimental results show that the proposed system has a fast and smooth start-up transient response. The output track current is fully controllable with a sufficiently good waveform for contactless power transfer applications.

무접점 전원공급 시 1차측 전류를 이용한 금속 물질 검출에 관한 연구 (The Metal Detection using Primary Current in Contact-less Power Supply)

  • 김유석;유주희;김춘삼;성원기
    • 전력전자학회논문지
    • /
    • 제17권5호
    • /
    • pp.445-452
    • /
    • 2012
  • The impurity detection method applied to existing discriminated the normality(R, L, C) and impurity(Metal) load using mutual RFID/ID method in the contactless power supply in which the primary side and the secondary side are completely separation by using the contactless transformer. However, this kind of system is caused the high cost of the system and complexity of control. Therefore, in this paper was proposed the contact-less power transfer using the primary current that determine normality or impurity load by compare the primary current Amplitude to reference quantity value and design the 3[W] contact-less power transfer and conduct an experiment for demonstrate the validity.

초기강우 유입 시 하수처리시설 일차 침전지 운전제어 전략 (Control strategy of primary clarifier operation in wastewater treatment plant during rainfall inflow)

  • 유광태;권혁재
    • 한국수자원학회논문집
    • /
    • 제52권11호
    • /
    • pp.947-950
    • /
    • 2019
  • 이 논문의 주요 특징은 초기강우 유입 시 일차 침전지 처리효율을 개선하기 위한 운전제어 전략을 제공하는 것이다. 최근 IoT 기술과 센싱 기술이 발전함에 따라 하수처리시설 운전제어를 위한 기반이 개선되고 있으며, 온라인 측정결과를 활용한 일차침전지 처리효율 개선에 따라 미처리 하수의 하천 유출을 최소화하고, 하수처리시설 운영효율 개선에기여할 수 있다.