• Title/Summary/Keyword: Primary clarifier

Search Result 23, Processing Time 0.027 seconds

Validity evaluation of wastewater treatment system applying advanced treatment processes (고도처리공법이 적용된 하수처리시설에서의 공법적용의 적정성 평가)

  • Ahn, June-Shu;Park, Tae-Sool;Cho, Jung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.4055-4068
    • /
    • 2010
  • In this study, validity of wastewater treatment system with advanced treatment processes was evaluated by studying its operational conditions by applying the advanced treatment to the wastewater treatment system which was operating for last several years. Study indicated a fair result for the removal efficiencies of BOD, T-P, and T-N for each unit operation. BOD removal efficiencies for primary clarifier, bioreactor, final effluent are 35, 87, and 48 % respectively. T-P(T-N) removal efficiencies for primary clarifier, bioreactor, final effluent are 18(23), 40(38), and 25(25) % respectively. Further investigation of bioreactor showed that various microorganism such as bacteria, protozoa, and metazoa is present in the bioreactor, and the main function of the media, adhesion (adsorption) of microorganism onto the media, is stabilized. Final effluent quality was lower than the regulation, and BOD, COD, SS, T-N, T-P were 5.5, 9.9, 4.6, 11.8, 0.99 mg/L respectively.

Finding the operation conditions to minimize nitrous oxide emission from MLE configuration wastewater treatment plant using computer simulation program (컴퓨터 시뮬레이션을 이용한 MLE 공법 하수처리장에서 최저 아산화질소 발생 운전 조건 파악)

  • Jisoo Han;Mincheol Kim;Byonghi Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.2
    • /
    • pp.19-38
    • /
    • 2023
  • Nitrous oxide, one of the six greenhouse gases from Kyoto protocol, is known to be emitted in biological nitrification and denitrification reactions at wastewater treatment plant. In this study, EQPS which is a computer program that can simulate nitrous oxide gas emission amount at wastewater treatment plants is used. The MLE process which treats wastewater from combined sewer is studied. Operational variables which are MLR, water temperature at reactor and primary clarifier by-pass percentage are changed to define the condition which produces the least amount of nitrous oxide gas. 200 % of MLR, 20 ℃ of water temperature at bioreactor and 15 % of primary clarifier by-pass percentage are shown the least nitrous oxide emission factor. Also, it is found that the deep aeration tank produces less amount of nitrous oxide gas since less air is required to meet oxygen demand in this type of aeration tank.

Development of Depot Encircled with Oxidation Canal for Water Quality Improvement (수질 개선을 위한 침전산화수로 개발)

  • 김원장;박상현
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.6
    • /
    • pp.83-89
    • /
    • 2000
  • A depot encircled with contact oxidation canal has been developed to improve water qualityr. The depot is aimed to settle suspended solid in the flow. The oxidation canal is to contact the pollutants and oxygen in the surface of gravel filter to purify the water. The deposit of the pollutant in the depot is released by the drainage culvert located at the bottom of it. Aeration nozzle is installed to supply enough oxygen to the gravel filter layers in the bottom of the detent the flow and improve oxidation efficiency. From the experiment it is founded that 91% of SS, 39% of TN, 63% of TP and 77% of COD were removed in the system. The treatment efficiency of total nitrogen is rather lower than any other components, however, it would be higher when some floating vegetation is added in the primary clarifier. The depot and oxidation canal system would be useful to purify the flows in the mouth of the reservoirs or at the outlet of the drainage canal.

  • PDF

The Effect of Hydraulic Loading on the Performance of Biofilter System (수리부하량 변화에 따른 바이로필터의 처리효율에 관한 연구)

  • 방천희;김철성;권순국
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.789-794
    • /
    • 1999
  • The performance of a small on-site wastewater treatment system consisting of an anaerobic septic tank and upgraded absorbent biofilter was investgted . The anaerobic septic tank was used as a pre-treatment of the absorbent Biofitler instead of the primary clarifier. The treatment capacity of the system was examined by changing the hydraulinc loadings to the Absorbent Biofilter as 2.5㎥/day , 4.5㎥/day, 6.0㎥/day, respective. The effluent from the septic tank was fed into the Absorbent Bilfilter. Based on the experimental results, the quality of treated wastewater satisfied the regulation and the BOD and SS was removed down to approximately 5mg/$\ell$ and 1mg/$\ell$, respectively.

  • PDF

Applicability Evaluation of Nitritation with Various Wastewater (다양한 하수를 대상으로 아질산화 반응 적용성 평가)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.17 no.1
    • /
    • pp.11-18
    • /
    • 2015
  • As the seriousness of water pollution resulted from nitrogen is being magnified, research has been conducted to reduce nitrogen in sewage as well as wastewater. Particularly research on innovative nitrogen removal methods that are based on the reaction of nitritation and are economically feasible and eco-friendly has been receiving attention. However, research on the applicability and efficiency of the methods based on the reaction of nitritation has not been completely done yet. Accordingly, the current study has analyzed the characteristics of sewage flowing into municipal wastewater treatment plants, primary clarifier supernatant, recycled water, and livestock wastewater and also operated a laboratory-level reactor. The result shows that recycled water and livestock wastewater contain higher-concentration nitrogen than other kinds of sewage, so they increase nitrogen loading in the water treatment line. And the result of operating a reactor shows that because of ammonium nitrogen low concentration, sewage and primary clarifier supernatant do not induce the reaction of nitritation. Also, there exist differences in the conditions of retention time inducing the reaction of nitritation by the types of sewage, and this seems to be attributed to organic compound and ammonium nitrogen concentration. Among the kinds of sewage inducing the reaction of nitritation, anaerobic digester supernatant indicates the highest efficiency.

A Study on Anaerobic Sewage Treatment Using a Fluidized Bed Reactor (유동상 반응조를 이용한 하수의 혐기성 처리에 관한 연구)

  • Ye, Hyoung-Young;Lee, Eun-Young;Bae, Jae-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.265-273
    • /
    • 2012
  • Anaerobic sewage treatment is drawing attentions due to high energy consumptions and sludge production associated with aerobic treatment. This study evaluates the treatment characteristics and energy balance of a fluidized bed reactor (FBR) for treating domestic sewage at $20^{\circ}C{\sim}25^{\circ}C$ for 245 days. Sewage fed to the FBR was a primary clarifier effluent of a domestic sewage treatment plant with COD of 99-301 mg/L and $BOD_{5}$ of 37-149 mg/L. Effluent $SBOD_{5}$ and its removal efficiency at HRT of 1~3 h were 6~15 mg/L and 73.4~85.5%, respectively, achieving high removal efficiency for soluble organic substances even at short HRTs. COD removal efficiency and its effluent concentration were 53.8~75.9% and 51~83 mg/L, respectively. The energy production potential from gaseous methane was 0.009-0.028 kWh/$m^{3}$, which satisfies the energy required for the FBR operation.

The Application of RO Membrane System in Municipal Wastewater Reclamation (RO Membrane System을 이용한 도시하수처리)

  • 이규현;안준수;유제강
    • Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.78-95
    • /
    • 1991
  • Water factory 21(WF 2) in Orange County California, is a advanced wastewater treatment(AWT) plant designed to reclaim biologically treated munidpal wastewater for injection into a seawater barrier system. Processes included are lime treatment air stripping, filtration, activated carbon adsorption, reverse osmosis(RO), and chlorination. The effectiveness of each treatment process is presented including pretreatment, RO dimineralization. The data collected show that the processes, including RO, used at WF-21 are capable of producing a very high quality water on a reliable basis. Treatment reduced all contaminants, to levels below national primary drinldng water regulation maximum contaminant levels. It was found that lime clarified secondary effluent can be used as feedwater to a RO dimineralizer. Experiments with new low pressure membrane(250psi) show great potential for reducing RO cost.

  • PDF

A Numerical Study On Various Energy and Environmental Systems (에너지${\cdot}$환경 제반 시스템에 관한 수치해석적 연구)

  • Jang D.S.;Song W.Y.;Na H.R.;Park B.S.;Lee E.J.;Kim B.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.160-168
    • /
    • 1995
  • This paper describes computational efforts on the various energy and environmental problems using Patankar's SIMPLE method. The specific problems included in this study are : pollutant and flammable material dispersions in open and confined areas, aerator-induced flow in a lake for DO(dissolved oxygen) concentration, primary clarifier for water and waste water treatment, hood ventilation in workplace, cyclone and LNG combustors and Dow chlorination reactor. A control-volume based finite-difference method is employed together with the power-law scheme. The pressure-velocity coupling is resolved by the use of the revised version of SIMPLE, says SIMPLER and SIMPLEC. The Reynolds stresses are closed using the standard or the RNG $k-{\varepsilon}$ models. Turbulent reaction is modeled using two fast chemistry methods such as eddy breakup and conserved scalar models. Further, a nonequilibrium model is developed for the application of the chlorination process in the Dow reactor. Other important empirical models and physical insights appeared in this study are presented and discussed in a brief note. The computational method developed in this study is considered, in general, as a viable tool for the design and determination of the optimal condition of various engineering system of interest.

  • PDF

A Performance Evaluation of the Highly Efficient Coagulation System for the Treatment of Overflows from Primary Clarifier in WWTP (강우시 하수처리장 일차침전지 월류수 처리를 위한 고효율응집시스템의 적용성 평가)

  • Gwon, Eun-Mi;Oh, Seok-Jin;Kim, Heung-Seup;Cho, Seung-Ju;Lee, Seung-Chl;Ha, Sung-Ryong;Lim, Chea-Hoan;Park, Ji-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.391-398
    • /
    • 2011
  • This study is to develop highly efficient coagulation system(HECS) that runs treatment with a short retention time to cover the overflow in the rain, which coagulation, mixing and settling are contacted in a single reactor and to estimate the applicability. Setting up 100ton/day-size pilot scale plant, the results of continuous operation in case of runoff, maintaining 20 minute-retention time at optimum chemical injection condition(Alum 100mg/L, Polymer 1.0mg/L) shows the highest removal efficiency(Turbidity 93.1%, TCODcr 80.6%, BOD 81.8%, SS 92.5%, TN 72.3% and T-P 87.3%). It was estimated that the large amount of cost for separate sewage system and the size of area for system instruction can be reduced if the HECS is applied for CSOs treatment because the HECS is so compact and quickly. When we see the results, HECS from this study could be able to treat the pollutant quickly within a short retention time only with coagulant and polymer, which could show high applicability.

The Statistical Analysis for the fate of Antibiotic Resistance according to the Spatial and Operational Wastewater Treatment Factors (하수 처리시설의 공간 및 운전인자에 따른 항생제 내성의 통계학적 분석)

  • Kim, Sung-Pyo;Cho, Yun-Chul;Kim, Lee-Hyung;Chandran, Kartik
    • Journal of Wetlands Research
    • /
    • v.13 no.1
    • /
    • pp.117-127
    • /
    • 2011
  • The aim of this study was to examine the fate of tetracycline resistant bacteria (TRB) and tetracycline resistant genes (TRG) according to the spatial and operational wastewater treatment factors. As part of the effort, TRB and TRG of water samples at each unit processes of three different wastewater treatment plants (WWTPs) were analyzed over seven month study periods. With the data about different spatial and operating conditions of these WWTPs, TRB and TRGs, principal component analysis (PCA) was performed to find out any general correlation trend. Based on the statistic analysis results, the extent of TRB concentration in the activated sludge (TRBAS) is much related to the TRB concentration in primary clarifier effluent (TRBPE). Also, the study results indicated that the fate of TRB and TRG are significantly affected by the SRT variations.