• Title/Summary/Keyword: Primary beam

Search Result 396, Processing Time 0.027 seconds

Patterns of Failure According to Radiation Treatment Technique in the Parotid Gland Cancer (이하선암의 술후 방사선치료시 방사선치료 방법에 따른 치료 실패 양상 분석)

  • Lee Sang-Wook;Lee Chang-Geol;Keum Ki-Chang;Park Cheong-Soo;Choi Eun-Chang;Shin Hyun-Soo;Chu Sung-Sil;Lee Suk;Cho Kwang-Hwan;Suh Chang-Ok;Kim Gwi-Eon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.16 no.2
    • /
    • pp.167-171
    • /
    • 2000
  • Objectives: To compare the outcomes of treatment with a focus on the effectiveness of the two primary techniques of radiation used for treating parotid gland malignancies. Materials and Methods: A retrospective analysis of 70 patients with parotid gland cancer treated between 1981-1997. Radiation was delivered through an ipsilateral field of high energy electron and photon in 37 patients(52.9%). Two wedge paired photon was used to treat in 33 patients(47.1%). The median dose was 60 Gy, typically delivered at 1.8-2.0Gy per fraction. The median follow-up times for surviving patients was 60 months. Results: The overall and disease free 5 year survival rates were 71.6% and 69.5%, respectively. Wedge paired photon and photon-electron treatment disease tree 5 year survival rates were 61.1% and 80.5%, respectively. Overall local failure rate was 18.6%. Local failure rate of wedge paired photon technique was higher than that of mixed beam technique. Late complication rate was 37.1%, but most of them were mild grade. Conclusion: Techniques of radiation were associated with local control. The technique of using an ipsilateral field encompassing the parotid bed and treated with high energy electrons often mixed photons was effective with minimal severe late toxicity. To irradiate deep sited tumors, we consider 3-D conformal treatment plan for well encompassing the target volume.

  • PDF

Postoperative radiotherapy for ependymoma

  • Jung, Jinhong;Choi, Wonsik;Ahn, Seung Do;Park, Jin Hong;Kim, Su Ssan;Kim, Young Seok;Yoon, Sang Min;Song, Si Yeol;Lee, Sang-Wook;Kim, Jong Hoon;Choi, Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.30 no.4
    • /
    • pp.158-164
    • /
    • 2012
  • Purpose: To evaluated the patterns of failure, survival rate, treatment-related toxicity and prognostic factors in postoperative radiotherapy of patients with ependymoma. Materials and Methods: Thirty patients who underwent surgery and postoperative radiotherapy for ependymoma between the period of June 1994 and June 2008 were reviewed retrospectively. The age of patients ranged from 21 months to 66 years (median, 19 years). Seventeen patients had grade II ependymoma, and 13 had grade III anaplastic ependymoma according to the World Health Organization grading system. The postoperative irradiation was performed with 4 or 6 MV photon beam with median dose of 52.8 Gy (range, 45 to 63 Gy), and radiation field including 2 cm beyond the preoperative tumor volume. Median follow-up period was 51 months (range, 12 to 172 months). Results: Fourteen out of 30 (46.7%) patients experienced recurrence, and 12 of those died. Among those 14 patients who experienced recurrence, 11 were in-field and 3 were out-of-field recurrence. The 5-year overall survival (OS) and progression-free survival (PFS) rates were 66.7% and 56.1%, respectively. On univariate analysis, tumor grade was a statistically significant prognostic factor for OS and PFS. There were two complications after surgery and postoperative radiotherapy, including short stature and facial palsy on the left side. Conclusion: We observed good survival rates, and histologic grade was a prognostic factor affecting the OS and PFS. Almost all recurrence occurred in primary tumor site, thus we suggest further evaluation on intensity-modulated radiotherapy or stereotatic radiosurgery for high-risk patients such as who have anaplastic ependymoma.

A Study on Dose Distribution using Virtual Wedge in Breast Cancer (유방암 환자에서 가상 쐐기모양 보상체의 선량분포 특성에 대한 연구)

  • Yun, Sang-Mo;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.7-12
    • /
    • 2007
  • In the radiation therapy for breast cancer patients, wedge shaped compensators are essentially used to achieve appropriate dose distribution because of thickness difference according to breast shapes. Tangential Irradiation technique has usually been applied to radiation therapy for breast cancer patients treated with breast conservative surgery. When a primary beam is incident on wedge shaped compensators from medial direction In tangential irradiation technique, low energy scattered radiation is generated and gives additional dose to the breast surface. As a method to reduced additional dose to breast surface, the use of virtual wedge shaped compensator is possible. Eclipse radiation treatment planning (RTP) systems Installed at our institution have virtual wedge shaped compensator for radiation therapy treatment planning. The dose distributions of 15, 30, 45, 60 degree physical wedges and virtual wedges were measured and compared. Results showed that there was no significant differences In symmetry of $10{\times}10$ field among various wedge angles. When the transmission factor was compared, transmission factor Increased linearly as the wedge angle Increased. These results Indicates that the appilcation of virtual wedge in clinical use is appropriate.

  • PDF

Strut-Tie Models and Load Distribution Ratios for Reinforced Concrete Beams with Shear Span-to-Effective Depth Ratio of Less than 3 (I) Models and Load Distribution Ratios (전단경간비가 3 이하인 철근콘크리트 보의 스트럿-타이 모델 및 하중분배율(I) 모델 및 하중분배율)

  • Chae, Hyun-Soo;Yun, Young Mook
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.3
    • /
    • pp.257-265
    • /
    • 2016
  • The failure behavior of reinforced concrete beams is governed by the mechanical relationships between the shear span-to-effective depth ratio, flexural reinforcement ratio, load and support conditions, and material properties. In this study, two simple indeterminate strut-tie models which can reflect all characteristics of the failure behavior of reinforced concrete beams were proposed. The proposed models are effective for the beams with shear span-to-effective depth ratio of less than 3. For each model, a load distribution ratio, defined as the fraction of load transferred by a truss mechanism, is also proposed to help structural designers perform the rational design of the beams by using the strut-tie model approaches of current design codes. In the determination of the load distribution ratios, the effect of the primary design variables including shear span-to-effective depth ratio, flexural reinforcement ratio, and compressive strength of concrete was reflected through numerous material nonlinear analysis of the proposed indeterminate strut-tie models. In the companion paper, the validity of the proposed models and load distribution ratios was examined by applying them to the evaluation of the failure strength of 335 reinforced concrete beams tested to failure by others.

Investigation on the Effective Moment of Inertia of Reinforced Concrete Flexural Members Under Service Load (사용하중 상태에서 철근콘크리트 휨부재의 유효 단면2차모멘트에 대한 고찰)

  • Lee, Seung-Bea;Park, Mi-Young;Jang, Su-Youn;Kim, Kang-Su;Kim, Sang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.3
    • /
    • pp.393-404
    • /
    • 2008
  • The approaches in many design codes for the estimation of the deflection of flexural reinforced concrete (RC) members utilize the concept of the effective moment of inertia which considers the reduction of flexural rigidity of RC beams after cracking. However, the effective moment of inertia in design codes are primarily based on the ratio of maximum moment and cracking moment of beam subjected to loading without proper consideration on many other possible influencing factors such as span length, member end condition, sectional size, loading geometry, materials, sectional properties, amount of cracks and its distribution, and etc. In this study, therefore, an experimental investigation was conducted to provide fundamental test data on the effective moment of inertia of RC beams for the evaluation of flexural deflection, and to develop a modified method on the estimation of the effective moment of inertia based on test results. 14 specimens were fabricated with the primary test parameters of concrete strength, cover thickness, reinforcement ratio, and bar diameters, and the effective moments of inertia obtained from the test results were compared with those by design codes, existing equations, and the modified equation proposed in this study. The proposed method considered the effect of the length of cracking region, reinforcement ratio, and the effective concrete area per bar on the effective moment of inertia, which estimated the effective moment of inertia more close to the test results compared to other approaches.

A Theoretical Calculation of Photon Dose Equivalent Conversion Factor For Extremity Dosimeter (말단선량계의 광자선량당량환산인자에 대한 이론적 계산)

  • Kim, Kwang-Pyo;Lee, Won-Keun;Kim, Jong-Su;Yoon, Yeo-Chang;Yoon, Suk-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.1
    • /
    • pp.41-50
    • /
    • 1996
  • In this study, the theoretical calculation of the air kerma-to-dose equivalent conversion factors was performed with a Monte Carlo N-Particle transport code for the two types of extremity phantom of the ANSI and the KAERI, respectively. Considering the distribution of absorbed dose due to the interaction of homogeneous Parallel broad beam of monoenergetic primary photons in the range between 15keV and 1.5MeV, the air kerma-to-dose equivalent conversion factors based on the kerma approximation were calculated. It is showed that all the theoretical conversion factors of the two types of the extremity phantom for the ANSI and the KAERI agree well with the experimental values of the ANSI N13.32 draft(1995) for each energy within 5.7%, maximum difference ratio, except for 13.6%, difference ratio in the case for the energy of less than 40keV. It is due to uncertainties of experiment occurred in the low X-ray energy range and geometry considered in the MCNP code.

  • PDF

The Preoperative Diagnosis of Thyroid Cancer in $^{18}F$-FDG PET/CT Dual Time Imaging of SUV and Evaluation of Radioactivity Measurement (갑상선암 수술 전 진단목적의 $^{18}F$-FDG PET/CT Dual Time Point영상에서 SUV값과 방사능 농도 측정법의 유용성 평가)

  • Lee, Hyun-Kuk;Khang, Hyun Soo;Yang, Seoung-Oh;Han, Man-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • Purpose : This study is designed to compare two parameters reflecting $^{18}F$-FDG uptake, SUV and radioactivity, for diagnosis of thyroid cancer in dual time $^{18}F$-FDG PET/CT imaging and to find which parameter is more useful to decide whether the tumor is malignant or not. Materials and Methods : We performed retrospective study for 40 patients. All patients are diagnosed as primary thyroid cancer and examined $^{18}F$-FDG PET/CT. First, we got the dispersion of scattering beam of neck and lung apex to set a background and compared each dispersion, mean value, standard deviation of maxSUV and radioactivity. Also, mean maxSUV, ${\Delta}maxSUV$, ${\Delta}maxBq$/ml(%) and radioactivity between groups according to lesion's size based on biopsy are compared with independent-sample t-test. Results : the values that were from maxSUV and radioactivity measurement technique were compensated and calculated to practical values for mean comparison and patients were divided to two groups based on tumor size, Group1 ($size{\leq}1$ cm, n=21), Group2 (size>1 cm, n=19) for accurate comparison. In Group1, maxSUV (semi-quantitative analysis) was increased from $5.64{\pm}5.85$ (1.89~17.84) at first image to $5.90{\pm}5.01$ (1.95~18.22) at second image and radioactivity (Bq/ml) (quantitative analysis) showed similar increase from $5.93{\pm}6.38$ (2.50~16.75) at first image to $6.01{\pm}5.25$ (2.66~16.58) at second image. In Group2, TFmaxSUV was $10.54{\pm}14.36$ (2.54~33.89) in true first image, TSmaxSUV was $9.85{\pm}12.88$ (2.62~26.20) in true second image separately. The maxSUV showed a significant difference in the mean comparison between the two groups (p=0.035) But, mean radioactivity (Bq/ml) was $5.93{\pm}6.38$ (4.81~40.99) in true first image, $6.01{\pm}5.25$ (4.51~36.93) in true second image and didn't show a significant difference statistically (p=0.126) Conclusion : In diagnosis of thyroid tumor, SUV and radioactivity depending on $^{18}F$-FDG uptake showed high similarity with coefficient of determination (R2=0.939) and malignant evaluation results using dual time also showed similar aspect. Radioactivity for evaluation of malignant tumor didn't show better specificity or sensitivity than maxSUV.

  • PDF

A Randomized Controlled Trial Comparing Clinical Outcomes and Toxicity of Lobaplatin- Versus Cisplatin-Based Concurrent Chemotherapy Plus Radiotherapy and High-Dose-Rate Brachytherapy for FIGO Stage II and III Cervical Cancer

  • Wang, Ji-Quan;Wang, Tao;Shi, Fan;Yang, Yun-Yi;Su, Jin;Chai, Yan-Lan;Liu, Zi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.14
    • /
    • pp.5957-5961
    • /
    • 2015
  • Background: We designed this randomized controlled trial (RCT) to assess whether lobaplatin-based concurrent chemotherapy might be superior to cisplatin-based concurrent chemotherapy for FIGO stage II and III cervical cancer in terms of efficacy and safety. Materials and Methods: This prospective, open-label RCT aims to enroll 180 patients with FIGO stage II and III cervical cancer, randomly allocated to one of the three treatment groups (cisplatin $15mg/m^2$, cisplatin $20mg/m^2$ and lobaplatin $35mg/m^2$), with 60 patients in each group. All patients will receive external beam irradiation (EBRT) and high-dose-rate intracavitary brachytherapy (HDR-ICBT). Patients in cisplatin $15mg/m^2$ and $20mg/m^2$ groups will be administered four cycles of $15mg/m^2$ or $20mg/m^2$ cisplatin intravenously once weekly from the second week to the fifth week during EBRT, while patients inthe lobaplatin $35mg/m^2$ group will be administered two cycles of $35mg/m^2$ lobaplatin intravenously in the second and fifth week respectively during pelvic EBRT. All participants will be followed up for at least 12 months. Complete remission rate and progression-free survival (PFS) will be the primary endpoints. Overall survival (OS), incidence of adverse events (AEs), and quality of life will be the secondary endpoints. Results: Between March 2013 and March 2014, a total of 61 patients with FIGO stage II and III cervical cancer were randomly assigned to cisplatin $15mg/m^2$ group (n=21), cisplatin $20mg/m^2$ group (n=21) and lobaplatin $35mg/m^2$ group (n=19). We conducted a preliminary analysis of the results. Similar rates of complete remission and grades 3-4 gastrointestinal reactions were observed for the three treatment groups (P=0.801 and 0.793, respectively). Grade 3-4 hematologic toxicity was more frequent in the lobaplatin group than the cisplatin group. Conclusions: This proposed study will be the first RCT to evaluate whether lobaplatin-based chemoraiotherapy will have beneficial effects, compared with cisplatin-based chemoradiotherapy, on complete remission rate, PFS, OS, AEs and quality of life for FIGO stage II and III cervical cancer.

Radiation Therapy for Primary Eyelid Cancers in Tunisia

  • Belaid, A;Nasr, C;Benna, M;Cherif, A;Jmour, O;Bouguila, H;Benna, F
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3643-3646
    • /
    • 2016
  • Management of eyelid cancers is based on surgery and/or radiotherapy (RT). The treatment objective is to control tumors with acceptable functional and esthetic outcomes. The aim of this study was to evaluate the results of radiation therapy in management of epithelial eyelid cancers, reviewing retrospectively the clinical records of patients treated in our institution from January 1989 to December 2013. We focused on clinical and histological features, treatment characteristics, tolerance and disease control. One hundred and eight patients (62 men and 46 women) were enrolled, with a mean age of 61 years [ranges 15-87]. The most frequent tumor location was the inner canthus (42.6%). Median tumor size was 21 mm [ranges 4-70]. Histological type was basal cell carcinoma in 88 cases (81.5%), squamous cell carcinoma in 16 (14.8%) and sebaceous carcinoma in 4 (3.7%). Radiation therapy was exclusive in 67 cases (62%) and post-operative for positive or close margins in the remaining cases. Kilovoltage external beam radiotherapy (KVRT) was used in 63 patients (58.3%) and low-dose-rate interstitial brachytherapy in 37 (34.3%). Eight (7.4%) were treated with cobalt or with a combination of KVRT-cobalt, KVRT-electron beams, KVRT-brachytherapy or cobalt-electron beams. The total delivered radiation doses were 70 Gy (2 Gy/fraction) in 62 patients (57.4%), 66 Gy (2 Gy/fraction) in 37 (34.3%) and 61.2 Gy (3.4Gy/fraction) in 9 (8.3%). After a median follow-up of 64 months, we noted 10 cases of local recurrences(9.2%): 7 after exclusive and 3 after post-operative RT. No local recurrence occurred in patients treated with brachytherapy. Actuarial 5-year local recurrence-free rate, disease-free survival and overall survival were respectively 90%, 90% and 97%. T-stage was found to be a significant factor for recurrence (p=0.047). All acute radiation-related reactions were scored grade I or II. Delayed effects were eye watering in 24 cases (22.2%), eye dryness in 19 (17.6%), unilateral cataract in 7 (6.4%) and ectropion in 4 (3.7%). Radiation therapy and especially brachytherapy is an efficient treatment of eyelid cancers, allowing eye conservation and functional preservation with good local control rates and acceptable toxicity.

Flexural Behavior and Design of Concrete-filled U-shape Hybrid Composite Beams Fabricated from 570MPa High-strength Steel (570MPa급 고강도강을 적용한 콘크리트 채움 U형 하이브리드 합성보의 휨거동 및 설계)

  • Lee, Cheol Ho;So, Hyun Joon;Park, Chang Hee;Lee, Chang Nam;Lee, Seung Hwan;Oh, Ha Nool
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.2
    • /
    • pp.109-120
    • /
    • 2016
  • Flexural tests of full-scale concrete-filled U-shape hybrid composite beams were conducted. Ordinary (SS400) and high-strength (SM570) steel plates were used in the web and in the bottom flange of U-shape steel section respectively. The primary objectives were to develop the hybrid section configuration with maximized flexural capacity and to investigate its flexural strength and deformation capacity. All the hybrid test specimens in this study exhibited the plastic moment capacity and resonable deformability. It is shown that the plastic stress distribution can be assumed in calculating the flexural strength of the proposed hybrid composite beams if the plastic neural axis is located within 15% of the total beam depth from the top of the composite slab. The procedure for computing the effective flexural stiffness of hybrid composite beams is also recommended based on test results.