• Title/Summary/Keyword: Primary Sludge

Search Result 113, Processing Time 0.025 seconds

Evaluation of Sewage Treatment Plant Efficiency in the Variation of Sewage Inflow and Sludge Interface Height by Rainfall (강우로 인한 유입하수량 증가와 슬러지 계면높이 변화에 따른 하수처리장 효율평가)

  • Park, Hye-Sook;Song, Seok Heon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.8
    • /
    • pp.549-553
    • /
    • 2014
  • Variation of sewage sludge interface height and flow rate by rainfall were applied to the actual public sewage treatment plant, and the efficiency of sewage treatment was evaluated by measuring $BOD_5$, $COD_{Mn}$, SS, T-N, and T-P. When both flow and interfacial height are increased, the treatment efficiencies in terms of the five water pollutants are decreased. Among them SS is the most critical pollutant in rainfall. When 0.5 Q inflow was applied, the efficiencies were 74.2% at the sludge interface height of 0.5 m, 76.4% at 1.0 m, 70.2% at 1.5 m, and 60.7% at 2.0 m. When 1.0 Q inflow was applied, the efficiencies were 71.7% at the sludge interface height of 0.5 m, 71.9% at 1.0 m, 46.4% at 1.5 m, and -38.0% at 2.0 m. Operation at 2.0 Q~2.0 m and 3.0 Q~1.0 m above the sludge rising phenomenon occurred causing adverse effects on the public bodies. If the flow rate increases, the processing efficiency is reduced from 74.2% to 17.3%, even though the sludge interface height was maintained at 0.5 m, so that the inflow adjustment was most important during rainfall, and the interface height of 1.0 m should be maintained to minimize the adverse effect on public water system.

A Mathematical Model for Prediction of the Fats of Polycyclic Aromatic Hydrocarbons in Activated Sludge Processes : Steady State and Dynamic Simulation (활성슬러지 하수처리장에 유입된 Polycyclic Aromatic Hydrocarbons의 농도분포를 예측하기 위한 수학적 모형의 개발)

  • Ko, Kwang Baik;Berthouex, Paul Mac
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.4
    • /
    • pp.173-184
    • /
    • 1990
  • A mathematical model was proposed to predict the predominant reactions and transport pathways of anthracene in a conventional activated sludge wastewater treatment system. The model consists of five differential equations with seven kinetic parameters and eighteen input variables. Volatilization, biodegradation, adsorption/desorption as well as the convective inputs and outputs are included in the model. The steady state calculations showed that volatilization (61%) in aeration tank and the withdrawal of primary sludge (33%) were two major pathways for removal of anthracene from the system. The overall removal was about 97%. The system reached a practical steady state at about 160 hours via dynamic modeling. The proposed model can give plausible predictions of the fate of priority organic pollutants in activated sludge processes.

  • PDF

Study on Concentrations and Mass Flows of Perfluorinated Compounds (PFCs) in a Wastewater Treatment Plant (폐수처리장의 과불화화합물 검출수준 및 처리공정 중 물질흐름 해석에 관한 연구)

  • Park, Jong-Eun;Kim, Seong-Kyu;Oh, Jung-Keun;Ahn, Sung-Yun;Lee, Mi-Na;Cho, Chon-Rae;Kim, Kyoung-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.326-334
    • /
    • 2012
  • To determine the concentrations and the mass flow of selected 10 perfluorinated compounds (PFCs), a field study was conducted in a wastewater treatment plant. Raw influent, primary influent, primary effluent, aeration tank effluent, secondary effluent, final effluent, dehydration liquor, primary sludge, thickened sludge, final sludge were collected over 3 days in the summer and the winter respectively. Collected samples were equally mixed and then served as an analytical sample. Total 10 compounds were analyzed. In terms of treated water, the concentration of perfluorooctanesulfonate (PFOS) and perfluorooctanoate (PFOA) were in range of N.D.~26.29 ng/L and N.D.~38.15 ng/L respectively. Perfluorononanoate (PFNA) and perfluorohexanesulfonate (PFHxS) were ranged from N.D. to 36.79 ng/L and from N.D. to 24.36 ng/L. In terms of sludges, a concentration of PFOS, PFOA, and perfluorodecanesulfonate (PFDS) were detected from 6.82 to 59.37 ng/g, from 0.13 to 0.37 ng/g, from N.D. to 0.83 ng/g respectively. Mass loading for PFCs increased during wastewater treatment except for PFNA. The observed increase in mass flow of PFCs may have resulted from biodegradation of precursor compounds.

Synthesis and Characterization of Zeolite Using Water Treatment Sludge (정수슬러지를 이용한 제올라이트의 합성 및 특성연구)

  • Ko, Hyun Jin;Ko, Yong Sig
    • Clean Technology
    • /
    • v.26 no.4
    • /
    • pp.263-269
    • /
    • 2020
  • Zeolite was synthesized hydrothermally using the water-treatment sludge, and the effects of various synthesis parameters like reaction temperature, reaction time, and Na2O/SiO2 molar ratio on the crystallization of zeolite were investigated. Crystal structure, physical property, and thermal stability of zeolite crystals were characterized by X-ray powder diffraction, FTIR spectroscopy, BET nitrogen adsorption, and TGA measurements. The removal efficiencies of nitrogen in ammonia, heavy metal ions, and TOC were calculated to evaluate zeolite's adsorption capacity. The primary chemical composition of water-treatment sludge was 28.79% Al2O3 and 27.06% SiO2. The zeolites were synthesized by merely employing the water-treatment sludge as silica and alumina sources without additional chemicals. Zeolite crystals synthesized through the water-treatment sludge were confirmed as an A-type zeolite structure. Zeolite A had the highest crystallinity obtained from a gel with the molar composition 2.1Na2O-Al2O3-1.6SiO2-65H2O after 5 h at a temperature of 90 ℃. The specific surface area of zeolite obtained was 55 ㎡ g-1, which was higher than commercial zeolite A. The removal efficiency of nitrogen in ammonia was 68% after 3 h of reaction time, while the removal efficiencies of Pb2+ and Cd2+ ions were 99.1% and 99.3%, respectively. These results indicate active ion exchange between Pb2+ or Cd2+ ion and Na+ ion in the zeolite framework. The adsorption experiments on the different zeolite addition conditions were performed for 3 h with 300 ppm humic acid. Based on the results, TOC's highest efficiency was 83% when 5 g of zeolite was added.

Characteristic evaluation of anaerobic co-digestion using desulfurization sludge and primary sludge (탈황슬러지 및 생슬러지를 이용한 혐기성 병합소화 특성평가)

  • Seulki Koo;Woojin Chung;Soonwoong Chang;Myoungsoo Park
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.4
    • /
    • pp.51-58
    • /
    • 2023
  • In this study, anaerobic co-digestion was carried out using desulfurization sludge and sewage sludge (primary sludge) to evaluate the effects of sulfur compounds in anaerobic digestion. The experiment was carried out in the form of a batch test using 500 mL duran bottle, and the mixing ratio of the feedstock was selected based on the ratio of COD/SO4. As a result of the experiment, it was confirmed that the amount of biogas generated and the yield decreased at the mixing ratio of COD/SO4 20 or less. In particular, below COD/SO4 10, it was lower than seed (283.5 mL) which was set without feedstock to correct biogas generated by itself from seed sludge. Methane yield tended to decrease from a ratio of COD/SO4 20 or less to 0.135 m3/kg VS compared to 0.396 m3/kg VS of COD/SO4 50. In addition, compared to 0.0097 m3/kg VS of hydrogen sulfide yield from COD/SO4 50, the ratio of COD/SO4 20 increased sharply to 0.0223 m3/kg VS, and in particular, the highest result was 0.0855 m3/kg VS in COD/SO4 10. Based on these results, it is judged that the effect of sulfide in anaerobic digestion can have an adverse effect if the COD/SO4 ratio decreases to less than 20.

An Analytical Study on The Polycyclic Aromatic Hydrocarbons of Wastewater Effluents from Petrochemical Industries (석유화학공업 폐수중 다환방향족 탄화수소류에 관한 조사연구)

  • 한희정;박석환;정문식
    • Journal of Environmental Health Sciences
    • /
    • v.20 no.3
    • /
    • pp.1-12
    • /
    • 1994
  • Wastewaters being treated and final effluents were collected from 3 wastewater treatment plants of petrochemical industries, from August 31 to October 4, 1993 in an interval of 10 days, and further analysed by GC/FID to investigate discharge situation and removal efficiency on polycyclic aromatic hydrocarbons. The results were as follows: 1. The PAHs 294.57 $\mu$g/l were discharged in primary treatment effluent of plant A to manufacture vinyl acetate resin and acryl, and removed 54.51% by aeration and totally 84.71%. 2. The PAHs of the highest concentration were discharged in primary treatment effluent of plant B to manufacture PS resin and ABS resin, but removed 91.65% by activated sludge process and 98.19% by activated carbon to discharge PAHs of the lowest concentration comparing to another treatment operations. 3. The PAHs 99.96 $\mu$g/l of the lowest concentration were discharged in wastewater of plant C to manufacture epoxy resin, and removed 80.48% by activated sludge process. 4. B treatment system including activated carbon showed up the best removal efficiency of PAHs. Activated carbon therefore, seems to be effective as tertiary treatment. 5. Correlation coefficient of components to total PAHs was generally low, and correlation coefficients of phenanthrene, pyrene and acenaphthylene to total PAHs were each 0.98, 0.97 and 0.80, respectively. Correlation coefficient of the sum of phenanthrene, pyrene and acenaphthylene to total PAHs was 0.99, so that the sum of phenanthrene, pyrene and acenaphthylene was available as index to estimated total PAHs. 6. Phenanthrene and Chrysene were very well treated biologically and acenaphthylene and fluoranthene were untreated biologically. 7. Considering EPA standards, it seems that the concentration of phenanthrene, pyrene, fluoranthene, and benzo(k)fluoranthene is high level.

  • PDF

Bacterial Removal Efficiencies by Unit Processes in a Sewage Treatment Plant using Activated Sludge Process (활성슬러지공정 하수종말처리장의 단위공정별 세균 제거효율)

  • Lee, Dong-Geun;Jung, Mira;Sung, Gi Moon;Park, Seong Joo
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.871-879
    • /
    • 2010
  • To figure out the removal efficiency of indicator and pathogenic bacteria by unit processes of a sewage treatment plant using activated sludge process, analyses were done for incoming sewage, influent and effluent of primary clarifier, aeration tank, secondary clarifier and final discharge conduit of the plant. A matrix of bacterial items (average of bacterial reduction [log/ml], p value of paired t-test, number of decreased cases of twenty analyses, removal percentage only for decreased cases) between incoming sewage and final effluent of the plant were heterotrophic plate counts (1.54, 0.000, 20, 95.01), total coliforms (1.38, 0.000, 19, 83.94), fecal coliforms (0.90, 0.000, 20, 94.84), fecal streptococci (0.90, 0.000, 20, 98.08), presumptive Salmonella (0.23, 0.561, 7, 99.09), and presumptive Shigella (1.02, 0.002, 15, 92.98). Total coliforms, fecal coliforms, heterotrophic plate counts, and fecal streptococci showed highest decrease through secondary clarifier about 1-log (p<0.001) between 88% and 96%, and primary clarifier represented the significant (p<0.05) decrease. However, final effluent through discharge conduit showed higher total coliforms and fecal streptococci than effluent of secondary clarifier (p<0.05). In addition, final effluent once violated the water quality standard while effluent of secondary clarifier satisfied the standard. Hence some control measures including elimination of deposits in discharge conduit or disinfection of final effluent are necessary.

Methods of Determination of Nonbiodegradable Organic Contents in Solid Wastes (고형(固形) 폐기물(廢棄物)내의 생물학적(生物學的)으로 분해불능(分解不能)한 유기물질(有機物質)의 함량(含量)의 결정(決定)에 관한 연구(研究))

  • Choi, Eui So
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.3
    • /
    • pp.113-118
    • /
    • 1988
  • Laboratory aerobic and anaerobic digesters were operated to determine the nonbiodegradable fractions in PS (Primary Sludge) and WAS (Waste Activated Sludge)from a municipal wastewater treatment plant in Seoul. Nonbiodegradable fractions were determined to be 45 to 47% in PS and 58 to 68% in WAS. Ultimate $CH_4$ gas production rates were estimated to be 0.76 for PS and $0.54m^3/kg$ VS removed for WAS. $CH_4$ contents were respectively 63% for PS and 65% for WAS.

  • PDF

Survey of the Secondary Effluents from Municipal Wastewater Treatment Plants in Korea (우리나라 하수처리장 방류수 수질현황 및 특성)

  • Kim, Youngchul;An, Ik-Sung;Kang, Min-Gi
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.158-168
    • /
    • 2005
  • In this study, the discharging effluents from have been 9 municipal wastewater treatment plants surveyed for 1 year-period. Statistics including probability distribution, cumulative occurrence concentration and other statistical parameters were presented. In addition, treatment performance and its stability were also discussed. Most of the plants, have an operational problem of high soluble organic content in the secondary effluent which may be associated with the integrated treatment of human and livestock manures. Nitrogen concentration in the effluents were usually higher during the period of summer and winter. It was found that this is mainly due to lack of the proper C/N ratio during the summer, or/and the effects of low temperature and less dilution by dry weather during the winter. Phosphorus concentration is sharply increased in June. Discussion with plant operators told that it is due to the dissolution of phosphate from the sludge accumulated in the primary settling tanks from the early spring to june. During this period, usually, sludge treatment line is highly overloaded with flush-outs of the sediments also stored in the bottom of combined sewer due to the low flow during winter season. Most of the plants can meet new effluent discharge limits of the nitrogen and phosphorus, and total coliform without further treatment.

Application of upflow multi-layer bioreactor (UMBR) for domestic wastewater treatment in HCMC

  • Cao, Duc Hung;Nguyen, Ngoc Han;Nguyen, Phuoc Dan;Bui, Xuan Thanh;Kwon, J.C.;Shin, H.S.;Lee, E.T.
    • Membrane and Water Treatment
    • /
    • v.3 no.2
    • /
    • pp.113-121
    • /
    • 2012
  • Up-flow multi-layer bioreactor (UMBR) is a hybrid system using dual sludge that consists of an up-flow multi-layer bioreactor as anaerobic/anoxic suspended growth microorganisms followed by an aeration tank. The UMBR acts as a primary settling tank, anaerobic/anoxic reactor, thickener which requires low energy due to mixing by up-flow stream. This study focused on using a pilot UMBR plant with capacity of 20-30 $m^3$/day for domestic wastewater in HCMC. HRTs of UMBR and aeration tank were 4.8 h and 7.2 h, respectively. The average MLSS of UMBR ranged from 10,000-13,600 mg/l SS. Internal recycle rate and sludge return were 200-300% and 150-200%, respectively. The results obtained from this study at flow rate of 20 $m^3$/day showed that removal of COD, SS, TKN, N-$NH_4$, T-N, and color were 91%, 87%, 86%, 80%, 91% and 91%, respectively.