• Title/Summary/Keyword: Preventive fire administration

Search Result 18, Processing Time 0.025 seconds

Analysis of Fire Risk Assessment Indicators of Publicly-Used Establishments using Delphi/AHP (Delphi/AHP를 활용한 다중이용업 신종업종의 화재위험평가지표 분석)

  • Kim, Myung-Cheol;Kim, Hak-Joong;Park, Kyung-Hwan;Youn, Hae-Kwon;Lee, Seung-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.87-94
    • /
    • 2019
  • Through a press release dated July 17, 2018, the Anti-Corruption and Civil Rights Commission recommended that the National Fire Agency develop preventive measures against fire in the "Indoor Archery Ground" and "Room Escape Café" etc., which were originally excluded from the category of "Publicly Used Establishments." This study developed the hierarchy of domains and indicators of measurement for fire risk assessment of the new business of publicly used establishments through the Delphi Method. It analyzed the goodness of fit scores (over 3.00) and secured an average score of 4.25. Using AHP analysis, the ratio of consistency for the domains of measurement of fire risk assessment was found to be 4.0%, which was lower than CR ≤ 0.1 (10%). The consistency of subsequent measurement indicators were distributed in the range of 0.1%~3.6%, and they were identified as being commonly consistent. The indicators of measurement appeared as follows in order of importance and priority: Type of Internal Passage of Establishment and Evacuation Capacity of Exit (0.316), Control of Ignition Source (0.141), Inherent Risk (0.106), Appropriateness and Adaptiveness of Fire Detection System (0.097), Control of Inflammables/Combustibles (0.084), Guides and Facilities helping Evacuation (0.075), Fire Resistant Structure and Finishing Materials (0.060), Compartmentalization and Emergency Exit (0.049), Risk of Fire Expansion (0.046), and Appropriateness and Adaptiveness of Fire Extinguishing Facilities (0.026). The findings of this study are expected to be expansively used as data for future research on the development of fire risk assessment indicators.

A Study on the Positive Economic Values of Rain After a Long Drought: for the Rainfall Case of 20~21 April, 2009 (오랜 가뭄 뒤 내린 비에 대한 긍정적 측면의 경제적 가치 연구: 2009년 4월 20~21일 강수 사례 중심으로)

  • Lee, Young-Gon;Kim, Baek-Jo;Cha, Kee-Uk;Park, Gil-Un;Ryoo, Kyong-Sik
    • Atmosphere
    • /
    • v.20 no.2
    • /
    • pp.173-186
    • /
    • 2010
  • The impact of the precipitation has been focused on losses in social and economical sectors. However, as growing the concerns of the future water shortage caused by the climate change, the precipitation should be consider in various views for an effective planning in the water resource management. A precipitation case occurred from 20 to 21 April 2009 was recorded as a welcome rain because it reduced the severe drought continued in Korea from winter season of 2008. In this study, economic values of the event was calculated with positive aspects in various sectors. The estimation is based on four major parts such as a secure of water resources, the improvement of air quality, the decrease of forest fires, and the reduction of the drought impact. The water resources only considered inflow waters into dams and the reservoirs managed by Korean public institutions and their economic values accounts for 5.92 billion won. Decreases of four air pollutants($PM_{10}$, $NO_2$, CO, and $SO_2$) were considered as the positive effects of the rainfall and estimated 175.4 billion won. The preventive effect of the forest fire after the rainfall results in 0.48 billion won. Finally, the rainfall during the drought period is effective to reduce the social costs of 108.65 billion won. Although the economic values estimated in this study explain parts of the positive effects of the precipitation, it can help to develop a comprehensive and systematic valuation system for the whole process of the precipitation. For doing this, various rainfall types should be analyzed in social-economic terms including economics, environments and hydrology.

Development of Monitoring Program for Detecting Current and Voltage Signals for Series Arc (직렬아크에 대한 전류 및 전압 신호분석이 가능한 Monitoring Program 개발)

  • Kim, Doo-Hyun;Park, Jong-Young;Kim, Sung-Chul;Lee, Jong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.2
    • /
    • pp.29-34
    • /
    • 2010
  • This paper is aimed to develop monitoring software for detecting the characteristics of current and voltage signals for series arc on electric wire. In order to attain this purpose, the characteristics of series arc were analyzed by the current and voltage signals on electric wire which were installed, and also analyzed by the changes of RMS, instantaneous of waveform value in time domain and THD in frequency domain. Monitoring program which analyze the signal was developed by Labview which can analyze in time domain and frequency domain, and save data. Experimental setup for detecting verification of monitoring program was composed loads of a lamp, an electric heater and an electric fan loads which were usually using. Measurement points for detecting verification of monitoring program were selected at both the panel board and the arc generator at the same time. As results of the experiments by monitoring program, the arc current waveform showed the same characteristic in all measurement points of all load. But the arc voltage waveform was different in each measurement point. When arc occurred, the THD of current value increased above 20%. The results of this study will be effectively used in developing the preventive system of electric fire by series arc.

Impact Range Comparative Analysis of BLEVE by Gas Leakage According to LPG Main Components (LPG 주성분에 따른 누출 폭발 피해 영향범위 비교분석)

  • Soo-Hee Lim;Su-Yeon Son;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.3
    • /
    • pp.51-57
    • /
    • 2024
  • The purpose of this study is to compare and analyze the impact range of explosion damage due to gas leaks at LPG filling stations, focusing on propane and butane, which are components of vehicle LPG. The scenarios were designed based on the explosion incident at an LPG filling station in Gangwon-do, where an actual gas leak accident occurred, resulting in Scenario I and Scenario II. The ALOHA program, developed by the U.S. National Oceanic and Atmospheric Administration (NOAA), was used as the tool to analyze the impact range of the explosion damage for both substances. The results of the study indicated that, under identical conditions, propane had a wider impact range of damage than butane. This is presumed to be due to the greater explosion energy of propane, attributable to its physicochemical properties. Therefore, when preparing for LPG leak accidents, measures for propane need to be prioritized. As safety measures for propane, two suggestions were made to minimize human casualties. First, from a preventive perspective, it is suggested to educate workers about propane. Second, from the perspective of response measures and damage minimization, it is suggested to thoroughly prepare emergency evacuation and rescue plans, evacuation routes, designated shelters, and emergency response teams. This study compares and analyzes the impact range of radiative heat damage based on LPG components. However, hazardous accidents are critically influenced by the type of leaking substance, the form of the leak, and meteorological factors affecting the diffusion pattern of the substance. Therefore, for future research, it is proposed to model various leakage scenarios for the same substance to conduct a comprehensive risk assessment.

A study on enhancing professionalism of civil anti-disaster organizations for public safety in Korea: with a focus on CAIND (한국 재난관리 체계에서 민간 방재조직의 전문성 제고 방안 - 지역자율방재단을 중심으로 -)

  • Chae, Jong-Sik
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.3
    • /
    • pp.163-178
    • /
    • 2021
  • Purpose: This study explored a plan for improving the overall preventive activity of Korean Citizen-Corps-Active-in-Disaster (CAIND). Methods: The study used the documentary survey and the technical approach methods. This way, detailed information regarding civil anti-disaster organizations was found in scholarly monographs, specialty publications, and master's/doctoral dissertations. It further utilized the statistical yearbooks between 2015 and 2018 from the Korean Ministry of Public Administration, Security, and Fire Service, and the National Statistical Office, to discover practical problems through a statistical analysis. Volunteer activities being inherent, related issues were reviewed at the same time to for purposes of clarifying the characteristics of disaster prevention activity by CAIND. Results: The study provided four major suggestions for improvement. First, the quota management system of Korean CAIND considering the characteristics of rural areas should be supplemented. Second, the education and training systems of Korean CAIND should be established to satisfy regional conditions. Third, management members' readership competency in operating organizations, including that of the Korean CAIND captain in charge, should be strengthened. Fourth, the reward system for Korean CAIND activities should be improved. Conclusion: In the future, the results of this study are expected to be utilized as a basic data to develop Korean CAIND.

Effects of Poria cocos Water Extract on DNCB-induced Atopic Dermatitis

  • Im, Lee-Rang;Ahn, Ji-Young;Kim, Jun-Ho;Xin, Mingjie;Yoo, Jae-Soo;Song, Bong-Suk;Song, Bong-Jun;Kim, Dae-Keun;Kim, Ok-Jin;Lee, Hyun-A;Kim, Dae-Ki;Lee, Young-Mi
    • Journal of Evidence-Based Herbal Medicine
    • /
    • v.2 no.2
    • /
    • pp.17-24
    • /
    • 2009
  • Poria cocos has been traditionally used for the treatment of edema, scanty urine, dizziness due to retention of fluid, reduced appetite due to asthenia of spleen, loose stool, diarrhea, distraction, sudden palpitation and insomnia in East Asia. The aim of this study was to confirm whether Poria cocos wonfire whethe(PCWE) and Poria cocos ointment (PCO) have a preventive e of ter Pthe development of afire wdethe(PCWE (AD) in 2,4-Diniwhochlorobenzene (oria)-applied Balb/ wme e. Oral administration (12.5wmg/kg, 25wmg/kg) of PCWE and fire al application (O.5wmg/mouse, 1.0mg/mouse) of PCO decreased the development of AD-like skin lesions, ear swelling, spleen weight, total serum IgE. PCWE and PCO significantly also inhibited the infiltration of mast cells in the dorsal skin.

  • PDF

Association between sleep quality and type of shift work in Korean firefighters

  • Hyun-Jeong Oh;Chang Sun Sim;Tae-Won Jang;Yeon Soon Ahn;Kyoung Sook Jeong
    • Annals of Occupational and Environmental Medicine
    • /
    • v.34
    • /
    • pp.27.1-27.12
    • /
    • 2022
  • Background: Shift work that interferes with normal sleep patterns, is known to be a cause of sleep disturbance and has been studied through various occupational groups. However, it is not known which shift type is better for sleep health. Methods: This study included 568 firefighters. Sleep quality was evaluated using Pittsburgh Sleep Quality Index. Sleep quality was categorized into 2 groups; good quality (≤ 5 points) and poor quality (≥ 6 points). Demographic variables, depression, anxiety, type of shift, and job were collected by self-reported questionnaires. The χ2 test, t-test, and multiple logistic regression analysis were used to evaluate the effect of shift type on the sleep quality of firefighters. Results: Three hundred thirty-seven firefighters (59.3%) have poor sleep quality. Compared to day workers, the odds ratios (ORs) of poor sleep quality were 2.169 (95% confidence interval: 1.137-4.134) in 6-day cycle, 2.161 (1.150-4.062) in 9-day cycle, 1.805 (1.087-2.997) in 21-day cycle, and 1.485 (0.718-3.069) in 3-day cycle. The ORs of poor sleep quality were 1.697(1.021-2.823) in fire suppression and 2.325 (1.213-4.455) in emergency medical service compared to administration. Conclusions: All shift work type except for the 3-day cycle was associated with poor sleep quality compared to day work.

A Study on the Thermal Crack Control of the In-Ground LNG Storage Tank as Super Massive Structures (지하식 LNG 저장탱크 구조물의 온도균열 제어에 관한 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.773-780
    • /
    • 2011
  • In this study, thermal stress analysis are carried out considering material properties, curing condition, ambient temperature, and casting date of the mass concrete placed in bottom slab and side wall of the in-ground type LNG tank as a super massive structure. Also, based on the numerical results, cracking possibility is predicted and counter measures to prevent the cracking are proposed. For the tasks, two optimum mix proportions were selected. From the results of the thermal stress analysis, the through crack index of 1.2 was satisfied for separately caste concrete lots except for the bottom slab caste in 2 separate sequences. For the double caste bottom slab, it is necessary introduce counter measures such as pre-cooling prior to the site construction. Also, another crack preventive measure is to lower the initial casting temperature by $25^{\circ}C$ or less to satisfy 1.2 through crack index criterion. In the $1^{st}$ and $2^{nd}$ caste bottom slab, the surface crack index was over 1.2. Therefore, the surface cracks can be controlled by implementing the curing conditions proposed in this study. Since the side wall's surface crack index was over 1.0, it is safe to assume that the counter preventive measures can control width and number of cracks.