• Title/Summary/Keyword: Preventive Diagnostic System

Search Result 76, Processing Time 0.043 seconds

Establishment of Diagnostic Criteria in the Preventive Diagnostic System for the Power Transformer (전력용 변압기 예방진단새스템의 진단기준치 실정)

  • Kweon Dong-Jin;Koo Kyo-Sun;Kwak Joo-Sik;Woo Jung-Wook;Kang Yeon-Wook
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.9
    • /
    • pp.449-456
    • /
    • 2005
  • The preventive diagnostic technique prevents transformers from power failure through giving alarm and observing transformers in service. And it helps to establish the plan for optimum maintenance of the transformer as well as to find location or cause of fault using accumulated data. Data detection and experience of the preventive diagnostic system need to establish the preventive diagnostic algorithm regarding interrelationship between detected data and deterioration of equipment. Therefore in-depth analysis about the preventive diagnosis system is required. KEPCO has adopted the preventive diagnostic system at nine 345kV substations since 1997. Techniques for component sensors of the preventive diagnosis system were settled but diagnosis algorithm, diagnostic criteria and practical use of accumulated data are not yet established. This paper, to build up the base of preventive diagnostic algorithm for the Power transformer. investigated the preventive diagnostic criteria for the power transformer.

Analysis of the Data Reliability for the Preventive Diagnostic System (예방진단시스템의 데이터 신뢰성 분석)

  • Kweon, Dong-Jin;Chin, Sang-Bum;Kwak, Joo-Sik;Woo, Jung-Wook;Choo, Jin-Boo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.2
    • /
    • pp.94-100
    • /
    • 2005
  • Abnormal symptoms on operating conditions of power transformer are monitored by a preventive diagnostic system which prevents the sudden power failure in case of quick progress of abnormal situation. The preventive diagnostic system helps plan the proper maintenance method according to the transformer conditions via accumulated data. KEPCO has adopted the preventive diagnostic system at nine of 345kV substations since 1997. Application techniques of the diagnostic sensors were settled, but diagnostic algorithm and practical use of accumulated data are not yet established. To build up the diagnostic algorithm and effective use of the preventive diagnostic system, the reliability of the data which were accumulated in a server computer is very important. This paper describes the data analysis in the server in order to advance the reliability of the accumulated data of the preventive diagnostic system. The principles and data flows of the diagnostic sensors were analyzed, and the data discrepancy between sensors and server were calibrated.

Investigation of the Preventive Diagnostic Criteria for Power Transformer (전력용 변압기 예방진단 기준치 검토)

  • Kweon, D.J.;Koo, K.S.;Kang, Y.W.;Woo, J.W.;Kwak, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.592-596
    • /
    • 2005
  • The preventive diagnostic system prevents transformers from power failure by giving alarm and observing transformers in service. And it helps to establish the plan for optimum maintenance of transformer as well as to find location or cause of fault using accumulated data. KEPCO has adopted the preventive diagnostic system at nine 345kV substations since 1997. Techniques for component sensors of preventive diagnostic system were settled but diagnostic algorithm, diagnostic criteria and practical use of accumulated data are not yet established. This paper, to build up the base of preventive diagnostic algorithm for the power transformer, investigated the preventive diagnostic criteria for power transformer.

  • PDF

Inspection On Sensors of Online Preventive diagnostic system Sensors for Power Transformer (변압기 온라인 예방진단 센서의 점검현황)

  • Koo, Kyo-Sun;Kweon, Dong-Jin;Chin, Sang-Bum;Kwak, Joo-Sik;Kang, Yeon-Woog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.455-460
    • /
    • 2005
  • Preventive diagnostic system for power transformer prevents the sudden power failure through monitoring of abnormal symptoms. KEPCO has adopted the preventive diagnostic system at nine 345kV substations since 1997. Application techniques of the diagnostic sensors were settled, but diagnostic algorithm and practical use of accumulated data are not yet established. To build up the diagnostic algorithm and effective use of the preventive diagnostic system, the reliability of the data accumulated in a server computer is very important. Therefore, this paper describes problem when apply system to substation and solution way to improve reliability of the system

  • PDF

Data Analysis of the Preventive diagnostic system of the 345kV Eui-Ryung substations (345kV 의령변전소 예방진단시스템의 데이터 분석)

  • Kweon, D.J.;Kang, Y.W.;Joo, B.S.;Lee, O.B.;Lee, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1899-1902
    • /
    • 2002
  • KEPCO is planning to operate 765kV Sin-Tao-Back and Sin-Ga-Pyong substations from 2004. A preventive diagnostic system to obtain the reliability of transformer and GIS is being adopted in 765kV substations. KEPRI has developed a preventive diagnostic system for 765kV substation since 1997. The preventive diagnostic system developed in that project was installed to the 345kV Eui-Ryung substation in June, 2000, and it is under circumstance durability test and operation capacity tests. In this paper, we analyze data of the preventive diagnostic system in 345kV Eui-Ryung substation.

  • PDF

Data Acquisition System Applying TMO for GIS Preventive Diagnostic System (GIS 예방진단시스템을 위한 TMO 응용 데이터 수집 시스템)

  • Kim, Tae-Wan;Kim, Yun-Gwan;Jang, Cheon-Hyeon
    • The KIPS Transactions:PartA
    • /
    • v.16A no.6
    • /
    • pp.481-488
    • /
    • 2009
  • GIS is used to isolate large power electrical equipment using SF6 gas. While GIS has simple structure, it has few break down, relatively high reliability. But it is hard to check up faults for reason of pressure. Faults of GIS should have a ripple effect on community and be hard to recovery. Consequently, GIS imports a preventive diagnostic system to find internal faults in advance. It is most important that reliability on the GIS preventive diagnostic system, because it estimates abnormality of system by analysis result of collected data. But, exist system which used central data management is low efficiency, and hard to guarantee timeliness and accuracy of data. To guarantee timeliness and accuracy, the GIS preventive diagnostic system needs accordingly to use a real-time middleware. So, in this paper, to improve reliability of the GIS preventive diagnostic system, we use a middleware based on TMO for guaranteeing timeliness of real-time distributed computing. And we propose an improved GIS preventive diagnostic system applying data acquisition, monitoring and control methods based on the TMO model. The presented system uses the Communication Control Unit(CCU) for distributed data handling which is supported by TMO. CCU can improve performance of the GIS preventive diagnostic system by guaranteeing timeliness of data handling process and increasing reliability of data through the TMO middleware. And, it has designed to take full charge of overload on a data acquisition task had been processed in an exist server. So, it could reduce overload of the server and apply distribution environment from now. Therefore, the proposed system can improve performance and reliability of the GIS preventive diagnostic system and contribute to stable operation of GIS.

Preventive diagnostic system for 765kV Sin-Ga-Pyong and Sin-Tae-Baek substations (765kV 신가평, 신태백 변전소 예방진단시스템)

  • Kweon, D.J.;Shim, E.B.;Jung, G.J.;Kim, B.J.;Kim, J.H.;Yoo, Y.P.;Eun, J.Y.;Shin, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1694-1697
    • /
    • 2002
  • KEPCO is planing to adopt a preventive diagnostic system to obtain the reliability of transformer and GIS in 765kV substation. KEPRI has developed the preventive diagnostic system for 765kV substation since 1997. We used various sensors and fault detecting devices such as a dissolved gas analyzer in oil, a ultrasonic detector and LA leakage current detector, etc., and carried out adaptation tests at the both a laboratory and a site. We developed a data acquisition system, a communication control unit and a server system as well. Furthermore, monitoring program and diagnostic expert system were also developed. This paper describes the preventive diagnostic system for 765kV Sin-Ga-Pyong and Sin-Tae-Baek substations which will be operated from 2004.

  • PDF

Development of the Preventive Diagnostic System for Substation (변전소 예방진단시스템 데이터 취득장치 개발)

  • Shim, J.T.;Sim, S.M.;Kweon, D.J.;Choi, I.H.;Jung, G.J.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.428-430
    • /
    • 2001
  • This paper describes development of a preventive diagnostic system for the substation equipments. Data acquisition system, communication control unit and computer systems have been developed in the recent 2 years. The developed system is operating in 345kV U-Ryung substation for performance and environment tests.

  • PDF

The Development of Classification System of Medical Procedures in Korea (한국표준의료행위 분류체계 개발)

  • Park, Hyoung-Wook;Sohn, Myong-Sei;Kim, Han-Joong;Park, Eun-Cheol;Yu, Seung-Hum
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.4 s.55
    • /
    • pp.877-897
    • /
    • 1996
  • In recent years, the Korean Medical Association has undertaken the feat of establishing the Korean Standard Terminology of Medical Procedures with the dedicated help of 32 medical academic societies. However, because the project is being conducted by several different circles, it has yet to see a clear system of classification. This thesis, therefore, proposes the three principles of scientific properties, usefulness and ideology as the basis for classification system and has developed the Classification System of Medical Procedures in Korea upon their foundation. The methodology and organization of this thesis as follows. First, by adopting scientific classification system of Feinstein(1988), an analysis of the classification systems of the medical procedures in the United States, Japan, Taiwan, WHO was carried out to reveal the framework and the basic principles in each system. Second, the direction of classification system has been constructed by applying the normative principle of medical field in order to show the future direction of the medical field and realize its ideology. Third, a finalized framework for the classification system will be presented as based on the direction of classification system. Of the three basis principles mentioned above, the analysis on the principles of usefulness was left out of this thesis due to the difficulty of establishing specific standards of analysis. The results of the study are as follows. The overall structure of the thesis is aimed at showing the 'Prevention-Therapy-Rehabilitation' quality of comprehensive health care and consists of six chapters; I. Prevention and Health Promotion II. Evaluation and Management III. Diagnostic Procedures IV. Endoscopy V. Therapeutic Procedures VI. Rehabilitation Chapter three Diagnostic Procedures is divided into four parts : Functional Diagnosis, Visual Diagnosis, Pathological Diagnosis, Biopsy and Sampling. Chapter five Therapeutic Procedures is divided into Psychiatry, Non-Invasive Therapy, Invasive Therapy, Anaesthesia and Radiation Oncology. Of these sub-divisions, Functional Diagnosis, Biopsy and Sampling, Endoscopy and Invasive Therapy employs the anatomical system of classification. On the other hand, Visual Diagnosis, Pathological Diagnosis, Anesthesia and Diagnostic Radiology, namely those divisions in which there is little or no overlapping in services with other divisions, used the classification system of its own division. The classification system introduced in this thesis can be further supplemented through the use of the cluster analysis by incorporating the advice and assistance of other specialists.

  • PDF

Basic design of the preventive diagnostic expert system for 765kV substation equipments (765 KV 변전설비 예방진단 전문가 시스템 기본설계)

  • Choi, I.H.;Kweon, O.J.;Jung, G.J.;Sun, J.H.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2133-2135
    • /
    • 1999
  • In this paper, we describe the basic design of the preventive diagnostic expert system for 765kV substation equipments. This expert system is developed to use expert system development tool and the main subjects considered are 765kV class power transformer and GIS. We basically designed the total structure of expert system and considered database interface methods, inference engine and control, triggering system which compose expert system.

  • PDF