• Title/Summary/Keyword: Prevention System

Search Result 4,794, Processing Time 0.03 seconds

A Study on Development of Lightning and Surge Protection System for Electrical Fire Prevention (전기화재 예방을 위한 낙뢰 및 써지 보호시스템 개발에 관한 연구)

  • Kwak, Dong-Kurl
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.3 s.40
    • /
    • pp.27-32
    • /
    • 2006
  • The occurrence frequency of lightning and surge from the weather accident is increasing recently, which the damage scale have been enlarged every year. A protection system development to solve these problems have been risen to a multinational concern field. In this paper, a novel protection system is proposed to restrain lightning and various surges which happen in electricity and communication equipment. The proposed protection system is designed to the structure to restrain the rise of the earth potential which is become to the problem of conventional protection system. The secondary damage as a result does not happen. The practicality of the developed surge protection system is proved through various accident occurrence simulator.

  • PDF

Design and Implementation of the Foot-and-Mouth Disease Prevention System using RTLS (RTLS를 이용한 구제역 예방 시스템의 설계 및 구현)

  • Lee, Ki-Young;Kim, Kyu-Ho;Kwun, Tae-Min;Lim, Myung-Jae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.4
    • /
    • pp.69-74
    • /
    • 2011
  • In this paper, we propose a foot-and-mouth disease prevention system using the RTLS technology and $A^*$ algorithm-based optimal path search method to avoid foot-and-mouth disease areas. The main features and contributions of the proposed system are as follows. First, the proposed system is developed based on active-tag for identifying status and location information of livestock. Second, the system is newly designed based on $A^*$ algorithm for supporting optimal path search services. The performance evaluation of the proposed system is performed via simulation. The results of performance evaluation show that the proposed system can efficiently support the optimal path search services.

A Study on Certification & Adoption of Occupational Health & Safety Management Systems in Korea (산업안전보건경영시스템의 인증 및 도입에 관한 연구)

  • 하정호;윤석준;강경식
    • Journal of the Korea Safety Management & Science
    • /
    • v.5 no.3
    • /
    • pp.21-30
    • /
    • 2003
  • This study was intended to help workplaces set up an occupational health & safety management system by investigating the certification of the system and by conducting a questionnaire to survey the necessity, purpose, effect and promotion of the system. The occupational health & safety management systems generally adopted in Korea are OHSAS 18001 and K-OHSMS 18001, which are the PDCA model, such like the quality and environment management system. Because these standards have a compatibility with other management systems, individual or integral certification is available. A telephone questionnaire was conducted with 30 workplaces in Kyeonggi Province and Incheon Metropolitan City, which have been certified for the occupational health & safety management systems (OHSAS 18001, KOSHA 2000, and/or K -OHSMS 18001). About 92 percent of them were large-sized workplaces with over 500 employees. For the question on the necessity of the system, most of the respondent answered very necessary. The purposes of the certification were to control the risks in safety and health, to have a systematic approach for accident prevention and sustainable improvement, and to comply with a range of regulations voluntarily, in that order. Most of the answers to the question on the effect of the system were prevention of accident. For the question on the promotion of the system, the most prominent answer was reduction in the workers compensation rate.

A Design of Disaster Prevention System and Detection of Wave Overtopping Number for Storm Surge base on CCTV (CCTV를 활용한 폭풍 해일의 월파 횟수 탐지 및 방재 시스템 설계)

  • Choi, Eun-Hye;Kim, Chang-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.2
    • /
    • pp.258-265
    • /
    • 2012
  • Our country is suffering from many human victims and property damages caused to occur great and small tidal waves in southern areas every year. Even though there were progressing many researches for storm surges, it was required more researches for detection of tidal wave and prevention system of its which can be applied in practical living fields. In this paper, we propose the disaster prevention system that can approximately detect a dangerousness of coast flooding and number of overtopping per time based on images of CCTV considering actual field application. And if it is detected a hazard of flooding of coast, the proposed detection system for tidal wave based GIS is quickly informed the areas of flooding to manager. The analyzing results of CCTV image of this proposed are derived from difference images between photos of fine day and photos or videos which are taken for the typhoon which is called "DIANMU" at our laboratory.

Physical test study on double-row long-short composite anti-sliding piles

  • Shen, Yongjiang;Wu, Zhijun;Xiang, Zhengliang;Yang, Ming
    • Geomechanics and Engineering
    • /
    • v.13 no.4
    • /
    • pp.621-640
    • /
    • 2017
  • The double-row long-short composite anti-sliding piles system is an effective way to control the landslides with high thrust. In this study, The double-row long-short composite anti-sliding piles with different load segment length (cantilever length) and different pile row spacing were studied by a series of physical tests, by which the influences of load segment length of rear-row piles as well as pile row spacing on the mechanical response of double-row long-short composite anti-sliding pile system were investigated. Based on the earth pressures in front of and behind the piles obtained during tests, then the maximum bending moments of the fore-row and the rear-row piles were calculated. By ensuring a equal maximum moments in the fore-row and the rear-row piles, the optimum lengths of the rear-row piles of double-row long-short composite system under different piles spacing were proposed. To investigate the validity of the reduced scale tests, the full-scale numerical models of the landside were finally conducted. By the comparisons between the numerical and the physical test results, it could be seen that the reduced scale tests conducted in this study are reliable. The results showed that the double-row long-short composite anti-sliding piles system is effective in the distribution of the landslide thrust to the rear-row and the fore-row piles.

Evaluation of Condensation Prevention for Centralized Hybrid Ventilation System Using TDR (TDR을 이용한 중앙집중형 하이브리드 환기시스템의 결로방지 성능 평가)

  • Kim, Yu-Min;Lee, Jong-Eun;Choi, Gyeong-Seok;Lee, Yong-Jun;Kang, Jae-Sik
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.81-86
    • /
    • 2015
  • Purpose: Condensation in the apartment housing is one of the most significant defects and complaints for condensation are rapidly increasing according to the growing interest in residential environment. Korea government established a regulation for reducing condensation in the apartment housing and TDR is adapted as a standard. However prevention of condensation depend on improving the performance of building envelop has limitation because of the increase of the cost. Centralized Hybrid ventilation system is suggested to prevent condensation. Method: Field measurement was conducted to verify the ventilation rate of the ventilation system. Based on the measurement, air network and CFD simulation was conducted to analyze ventilation rate for each room. Surface temperature was calculated by regulated TDR according to the regions and surfaces. The performance of condensation prevention was evaluated by the ventilation rate and surface temperature. Result: In the results, it was found that condensation was prevented in more than 90% of households by the centralized hybrid ventilation system which provided 0.19 ~ 0.81ACH for each room.

An Implementation of the Spam Mail Prevention System Using Reply Message with Secrete Words (비밀단어의 회신을 이용한 스팸메일 차단 시스템의 구현)

  • Ko Joo Young;Shim Jae Chang;Kim Hyun Ki
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.1
    • /
    • pp.111-118
    • /
    • 2005
  • This paper describes an implementation of the spam mail prevention system using reply message with secrete words. When user receives a new e-mail, the e-mail address is compared with the white e-mail addresses in database by the system. If user receives a new e-mail which does not exist in a white e-mail addresses database, a reply e-mail attached with secrete words is delivered automatically. And the system is compared with the white domains first for intranet environment. It speeds up processing time. proposed algorithm is required a small database and faster than the black e-mail addresses comparison. This system is implemented using procmail, PHP and IMAP on Linux and the user can manage the databases on the web.

  • PDF

A Study for the Computer Simulation on the Flood Prevention Function of the Extensive Green Roof in Connection with RCP 8.5 Scenarios (RCP 8.5 시나리오와 연동한 저관리형 옥상녹화시스템의 수해방재 성능에 대한 전산모의 연구)

  • Kim, Tae Han;Park, Sang Yeon;Park, Eun Hee;Jang, Seung Wan
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.17 no.3
    • /
    • pp.1-11
    • /
    • 2014
  • Recently, major cities in Korea are suffering from frequent urban flooding caused by heavy rainfall. Such urban flooding mainly occurs due to the limited design capacity of the current drainage network, which increases the vulnerability of the cities to cope with intense precipitation events brought about by climate change. In other words, it can be interpreted that runoff exceeding the design capacity of the drainage network and increased impervious surfaces in the urban cities can overburden the current drainage system and cause floods. The study presents the green roof as a sustainable solution for this issue, and suggests the pre-design using the LID controls model in SWMM to establish more specific flood prevention system. In order to conduct the computer simulation in connection with Korean climate, the study used the measured precipitation data from Cheonan Station of Korea Meteorological Administration (KMA) and the forecasted precipitation data from RCP 8.5 scenario. As a result, Extensive Green Roof System reduced the peak runoff by 53.5% with the past storm events and by 54.9% with the future storm events. The runoff efficiency was decreased to 4% and 7%. This results can be understood that Extensive Green Roof System works effectively in reducing the peak runoff instead of reducing the total stormwater runoff.

A Preliminary Design for Hybrid Building System with Progressive Collapse Prevention Means (연속붕괴가 방지된 초고층 복합빌딩시스템의 예비설계)

  • Choi, Ki-Bong;Cho, Tae-Jun;Kim, Seong-Soo;Lee, Jin-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.48-54
    • /
    • 2015
  • In this study, we propose an innovative lateral force distribution building system between tall buildings by utilizing the difference of moment of inertia, resulting the reduction of lateral displacement and the lateral forces in terms of an alternative for the dense human and increased cost of lands in highly integrated city area. A successive collapse prevention means by providing additional bearing plate between connections is proposed. In addition to that, a more economical vibration reduction is expected due to the suggested tuned mass damper on the surface of spacial structure. In the considered verification examples, reduced drifts at the top location of the building systems are validated against static wind pressure loads and static earthquake loads. The suggested hybrid building system will improve the safety and reliability of the new or existing building system in terms of more than 30% reduced drift and vibration through the development of convergence of tall buildings and spatial structures.

A Study on the Prevention of Lightning Accidents According to Climate Change Response (기후변화에 따른 낙뢰사고 예방을 위한 제도 방안 연구)

  • Ju, Suk-won;Kim, Seong-Bin;Rie, Dong-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.48-55
    • /
    • 2020
  • The installation of lightning protection system has recently been increasing, but the amount of damage has still been increasing. In this study, survey (interview) and field conditions were conducted to identify the installation and safety standards of the lightning protection system. it was analyzed that the safety management system is non-existent at the stage of the design, manufacturing and construction of the site lightning protection system, and that the safety inspection of the lightning protection facility is not properly managed. It has been shown that lightning protection systems, that can solve these problems, need to be re-established according to the reality so that safety inspection can be carried out in accordance with safety standards such as management of safety certification products, operation of survey institutions, design, manufacturing, and construction of safety standards at a national level.