• Title/Summary/Keyword: Prevent fires

Search Result 161, Processing Time 0.026 seconds

Classification of Forest Fire Occurrence Risk Regions Using Forest Site Digital Map (수치산림입지도를 이용한 산불발생위험지역 구분)

  • An Sang-Hyun;Won Myoung-Soo;Kang Young-Ho;Lee Myung-Bo
    • Fire Science and Engineering
    • /
    • v.19 no.3 s.59
    • /
    • pp.64-69
    • /
    • 2005
  • In order to decrease the area damaged by forest fires and to prevent the occurrence of forest fires, we are making an effort to improve prevention measures for forest fires. The objective of this study is developing the forest fire occurrence probability model by means of forest site characteristics such as soil type, topography, soil texture, slope, and drainage and forest fire sites. Conditional probability analysis and GIS were used in developing the forest fire occurrence probability model that was used in the classification of forest fire occurrence risk regions.

Assessment of steel structures designed for progressive collapse under localized fires

  • Behrouz Behnam
    • Steel and Composite Structures
    • /
    • v.46 no.2
    • /
    • pp.279-292
    • /
    • 2023
  • Structural design against the progressive collapse has been a vital necessity for decades due to occasional tragic events. The question of whether designed structures against the progressive collapse are still robust if subjected to multi-hazard scenarios containing column removal and successive localized fires is ad-dressed in the current study. Two seven-story steel structures with an identical area but different structural configurations of 4- and 5-bays are designed against the progressive collapse; the structural components are also fireproofed for a 60 min fire resistance. The structures are then subjected to different column re-moval scenarios over different stories followed immediately by localized fires. Results indicate that the structures are not able to keep their stability under all of the considered scenarios; the 4-bay structure is more vulnerable than the 5-bay structure. It is also indicated that upper stories are more sensitive toward the considered scenarios than lower stories. To advance structural safety, two strategies are adopted: in-creasing the thickness of the insulation materials to reduce the thermal effects, or, increasing the safety fac-tor (ΩN) of the structures when designing against the progressive collapse. As for the first strategy, provid-ing a 35% and a 25% increase in the insulation thicknesses of the structural components of the 4-bay and 5-bay structures, respectively, can prevent a progressive collapse to trigger. As for the second strategy, in-creasing ΩN by 10% can enhance the structural integrity to where no collapse occurs under all of the sce-narios.

Study on Horizontal and Vertical Temperature Analysis of Cable Fire in Common Duct using Room Corner Experiment (룸코너 실험을 이용한 공동구 케이블 화재 시 수평·수직 방향 온도 분석에 관한 연구)

  • JaeYeop Kim;SeHong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.634-643
    • /
    • 2023
  • Purpose: Underground common duct fires are steadily occurring, and the proportion of property damage is particularly large among property and human casualties caused by fires. Especially, cable fires that occur in common areas can spread vertically quickly and pose a great risk. This paper aims to scientifically analyze the nature of the fire by reproducing the fire through experiments. Method: To analyze the characteristics of cable fires in underground common duct, heat release rate and temperature changes were measured through Room-corner (ISO 9705) test, and the vertical and horizontal propagation of cable fires was quantitatively compared and analyzed. Result: The Room Corner Test (ISO 9705) was used to compare the temperature changes at each data logger point. The results showed that the time it took for the fire to reach the ignition temperature in the horizontal and vertical directions from the center point of the first-tier cable was 589 seconds and 536 seconds, respectively, which means that the vertical fire propagation is 53 seconds faster than the horizontal propagation. This proves that the vertical propagation of fire is relatively faster than the horizontal propagation. The horizontal propagation speed of the fire was also compared for each floor cable tray. The results showed that the third-tier cable propagated at 3.4 times the speed of the second-tier cable, and the second-tier cable propagated at 1.5 times the speed of the first-tier cable. This means that the higher the cable is located, the faster the fire spreads and the larger the fire becomes. Conclusion: This study identified the risks of cable fires and analyzed the risks of vertical fire propagation during cable fires based on the results of the Room Corner Test. Studies to prevent the spread of fire and fire response policies to prevent vertical fire propagation are required. The results of this study are expected to be used to assess the fire risk of common areas and other fires.

A Study on Indoor Smoke Detection Based on Convolutional Neural Network Using Real Time Image Analysis (실시간 영상분석을 이용한 합성곱 신경망 기반의 실내 연기 감지 연구)

  • Ryu, Jin-Kyu;Kwak, Dong-Kurl;Lee, Bong-Seob;Kim, Dae-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.537-539
    • /
    • 2019
  • Recently, large-scale fires have been generated as urban buildings have become more and more density. Especially, the expansion of smoke in buildings due to high-rise is an problem, and the smoke is the main cause of death in fires. Therefore, in this paper, the image-based smoke detection is proposed through deep learning-based artificial intelligence techniques to prevent possible damage if existing detectors are not detected. In addition, the detection model was not configured simply through only the smoke data set, but the data set in the haze form was additionally composed together to compensate for the accuracy.

  • PDF

Presidential Public Diplomacy 2.0: Seven Lessons to Prevent Fire in Cyberspace

  • dos Santos, Niedja de Andrade e Silva Forte
    • Journal of Public Diplomacy
    • /
    • v.1 no.1
    • /
    • pp.36-56
    • /
    • 2021
  • The Amazon fires in summer 2019 triggered an incendiary Twitter debate between French president Emmanuel Macron and Brazilian president Jair Bolsonaro that engaged political leaders, celebrities, and audiences worldwide. Currently, diplomats-in-chief connect to the global public through completely open debates, often without proper advice from foreign-affairs ministers, which may result in misunderstandings and conflicts among world leaders. Hence, this study argues that these interactions must be supported by Nicholas Cull's seven lessons in public diplomacy. The main topic on hand is presidential public diplomacy performed through digital means in cyberspace. Thus, after distinguishing cyberspace, digital diplomacy, and cyberdiplomacy, the literature review focuses on presidential public diplomacy, presidential diplomacy on Twitter, and Cull's seven lessons. Subsequently, the case study method provides a snapshot of the debate between Macron and Bolsonaro over the Amazon fires. This study concludes by answering the research question and indicating grist for the mill with regard to future developments.

Forest Fire Detection System using Drone Streaming Images (드론 스트리밍 영상 이미지 분석을 통한 실시간 산불 탐지 시스템)

  • Yoosin Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.5
    • /
    • pp.685-689
    • /
    • 2023
  • The proposed system in the study aims to detect forest fires in real-time stream data received from the drone-camera. Recently, the number of wildfires has been increasing, and also the large scaled wildfires are frequent more and more. In order to prevent forest fire damage, many experiments using the drone camera and vision analysis are actively conducted, however there were many challenges, such as network speed, pre-processing, and model performance, to detect forest fires from real-time streaming data of the flying drone. Therefore, this study applied image data processing works to capture five good image frames for vision analysis from whole streaming data and then developed the object detection model based on YOLO_v2. As the result, the classification model performance of forest fire images reached upto 93% of accuracy, and the field test for the model verification detected the forest fire with about 70% accuracy.

Study of IoT Service Strategy for Prevent Disasters (재난재해 감소를 위한 사물인터넷 서비스)

  • Yoon, YoungDoo;Choi, Hun
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.11
    • /
    • pp.102-109
    • /
    • 2017
  • The Nation's Constitution stipulates that the nation should strive to prevent disasters and protect the public from harm. That is, the nation is a protector of the protection of people's lives and property from potential danger. The disasters are the most important global issues, and disasters scope are not confined to natural disasters such as pre-existing earthquakes, landslides, floods, fires and fires extend to cyber terror and disease. In the age of IoT and ability of analyze big data, the establishment of a disaster prevention service system in modern society is a priority for the nation. In this study, we will explore the disaster prevention services for each country using IoT technology. Based on the research, it is believed that it will be the foundation for establishing strategies for service system of disasters using IoT technology.

A Study of Fire Prevention Measures for Single-person Households (1인 가구의 화재예방 대책 연구)

  • Kim, Jong Kouk;Han, Dong-Ho
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.424-431
    • /
    • 2021
  • This study explores fire prevention measures for single-person households on the phenomenon of an increase in single-person households due to changes in the family structure due to low birthrate and aging population, full marriage, non-marriage, separation, bereavement, and returning to farming villages, and increased flexibility in the labor market. The factor that affects the fire of single-person households is the residential environment problem at the structural level. In terms of behavior, there is an increase in fire occurrence due to the rearing of companion animals. In order to prevent fires in single-person households, safety regulations without exceptions are needed to improve the residential environment at the structural level. At the behavioral level, it is necessary to expand the prevention and safety guidance of related organizations. In addition, as a measure to prevent fire caused by companion animals, manufacturers of electric ranges should develop safety devices to prevent fires caused by companion animals, such as an automatic power-off device or power supply using a timer. It can also be an important means to create and distribute promotional videos of measures necessary to safely raise companion animals, or to develop and distribute disaster preparedness programs implemented in virtual reality.

A statistics and study of fire cause by electrics (전기로 인한 화재 원인 통계와 고찰)

  • Lee, Young-Soo;Kim, Myeong-Soo;Hawng, Byung-Pyo;Kim, Hyeong-Soo;Song, Young-Hak
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.10 no.1
    • /
    • pp.47-57
    • /
    • 2007
  • If it were the occurrence of fire by electricity with the rapid growth of economy, it would be serious damage for nation that effect human life and properties. To prevent electrical fires, it was basic countermeasure that make detail statistics classified by the source, place etc. with examining correct cause of fire. In this paper, we analuzed the present condition of fire occurrence of the lastest ten years and classified fires by the source, place, month in 2006. In addition our corporation staff execute in-depth and professional research on the actual state of electrics fire by visiting fire stations fire of the whole country for 8,554 electric fires in 2005. I expect this thesis to be used for preventing electric fires and providing a stepping stone on correct production of fire statistics.

  • PDF

Study on the Development of Protective Walls to prevent the spread of Ultra-Fast Fire in Small Industrial Facilities (소규모 산업시설의 초고속 화재 확산 방지를 위한 방호벽체 개발 연구)

  • Choe, Gyeong-Choe;Kim, Hong-Seop2
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.275-276
    • /
    • 2023
  • This study introduces the current progress of study on the development of protective wall aimed at preventing the spread of ultra-fast fires and ensuring fire safety in industrial facilities.

  • PDF