• 제목/요약/키워드: Pressurized Heavy Water Reactor Pressure Tube

검색결과 11건 처리시간 0.029초

DETERMINISTIC EVALUATION OF DELAYED HYDRIDE CRACKING BEHAVIORS IN PHWR PRESSURE TUBES

  • Oh, Young-Jin;Chang, Yoon-Suk
    • Nuclear Engineering and Technology
    • /
    • 제45권2호
    • /
    • pp.265-276
    • /
    • 2013
  • Pressure tubes made of Zr-2.5 wt% Nb alloy are important components consisting reactor coolant pressure boundary of a pressurized heavy water reactor, in which unanticipated through-wall cracks and rupture may occur due to a delayed hydride cracking (DHC). The Canadian Standards Association has provided deterministic and probabilistic structural integrity evaluation procedures to protect pressure tubes against DHC. However, intuitive understanding and subsequent assessment of flaw behaviors are still insufficient due to complex degradation mechanisms and diverse influential parameters of DHC compared with those of stress corrosion cracking and fatigue crack growth phenomena. In the present study, a deterministic flaw assessment program was developed and applied for systematic integrity assessment of the pressure tubes. Based on the examination results dealing with effects of flaw shapes, pressure tube dimensional changes, hydrogen concentrations of pressure tubes and plant operation scenarios, a simple and rough method for effective cooldown operation was proposed to minimize DHC risks. The developed deterministic assessment program for pressure tubes can be used to derive further technical bases for probabilistic damage frequency assessment.

중수로 연료관 검사시스템 개발 (Development of Fuel Channel Inspection System in PHWR)

  • 최성남;양승옥;김광일;이희종
    • 비파괴검사학회지
    • /
    • 제36권1호
    • /
    • pp.60-67
    • /
    • 2016
  • 가압중수로는 운전중 연료교체가 가능하도록 설계된 연료관에서 핵분열을 유도하여 에너지를 얻는다. 연료관은 핵연료와 직접 접촉하며 원자로 냉각재의 통로인 압력관, 주위 감속재와 접촉하며 원자로에 확관된 원자로관, 이것을 양쪽에서 지지하는 엔드피팅과 압력관과 원자로관의 접촉을 방지하기 위한 스페이서 등으로 구성되어 있다. 연료관은 가장 안전성이 요구되는 설비이므로, 캐나다 기술기준 CSA N 285.4에 따라 주기적이고 철저한 가동중검사를 수행하여 건전성을 확인한다. 월성 중수로 연료관의 가동중검사를 수행하기 위해 연료관 검사시스템을 개발하였다. 본 논문은 월성 연료관 현장시험 결과를 검토하고, 개발된 연료관 검사시스템의 유효성을 확인하였다.

가압 중수로형 원자력발전소 압력관 비파괴검사기술의 상호비교 (Intercomparisonn of Techniques for Pressure Tube Inspection of Pressurized heavy Water Reactor)

  • 이희종;김용식;윤병식;이영호
    • 비파괴검사학회지
    • /
    • 제25권4호
    • /
    • pp.294-303
    • /
    • 2005
  • 본 논문은 가압 중수로형 원자력발전소 압력관의 건전성 평가에 적용하고 있는 각 비파괴검사기술의 특정을 평가하기 위해서 IAEA(International Atomic Energy Agency)주관으로 세계 6개국이 참여하는 수행한 다자간 비교시험(Round-Robin Test)결과를 분석한 내용이다. 이 다자비교시험에는 세계적으로 현재 가압 중수로형 원자력발전소를 운영하고 있는 한국, 카나다, 인도, 아르헨티나, 루마니아, 중국 등 총 6개구깅 참여하였으며, 시험에는 한국에서 제작한 인공결함시험편(시험편명 : "KOR-1")이 사용되었다. 본 연구를 위해 참여 6개국에서 적용한 비파괴검사 기술은 현재 압력관의 건전성 평가에 적용되고 있는 초음파검사와 와전류검사 등의 2가지 기술이다. 결함시험편에는 균열성 노치, 마모 등의 총 12개의 인공결함이 포함되어 있으며, 이 인공결함은 발전소 운전중 발생 가능성이 있는 결함과 유사한 형태를 가지고 있다. 다자비교시험 결과 참여 6개국에서 두가지 비파괴검사법을 적용하여 시험편내에 포함되어 있는 총 12개의 모든 인공결함을 검출하였으며, 결함 검출도는 초음파검사법이 와전류검사법보다 우수하였다. 또한 압력관 시험편 내경측 결함이 외경측 결함보다 용이하게 검출되었으며, 크기 측정 정확도는 결함 검출도와 동일하게 시험편 내경측 결함의 크기가 외경측 결함보다 더 정확하게 측정되었다.

가압중수로 압력관 이물질 프레팅 결함의 탄성 응력집중계수 수식 도출 (Derivation of Elastic Stress Concentration Factor Equations for Debris Fretting Flaws in Pressure Tubes of Pressurized Heavy Water Reactors)

  • 김종성;오영진
    • 대한기계학회논문집A
    • /
    • 제38권2호
    • /
    • pp.167-175
    • /
    • 2014
  • 가동중검사 동안 가압중수로 압력관에서 탐지된 베어링 패드 프레팅 결함, 이물질 프레팅 결함 등 체적결함에 대해서는 CSA N285.8-05 에 따라 탄성 응력집중계수 수식을 이용하여 피로균열 및 수소지연균열이 개시되는 것을 평가하여야 한다. CSA N285.8-05 에는 이물질 프레팅 결함에 대해서는 선형파괴역학 기반한 개략적인 수식만이 제시된다. 본 연구에서는 이러한 이물질 프레팅 결함에 대해 2 차원 유한요소 해석과 일부 수정된 Kinectrics 사의 공학적 절차를 통해 이물질 프레팅 결함의 기하학적 특성이 좀더 상세히 고려된 탄성 응력집중계수 수식을 도출하였다. 도출된 수식을 적용한 결과와 3 차원 유한요소 해석 결과를 비교한 결과, 도출된 수식은 유한요소 해석과 잘 일치하는 결과를 얻을 수 있음을 확인하였다.

와전류검사 기술을 적용한 가압중수로 원전 압력관 비파괴검사 (Nondestructive Examination of PHWR Pressure Tube Using Eddy Current Technique)

  • 이희종;최성남;조찬희;유현주;문균영
    • 비파괴검사학회지
    • /
    • 제34권3호
    • /
    • pp.254-259
    • /
    • 2014
  • 중수로 원자로는 한 개의 원자로용기로 구성된 경수로와는 달리 약 380여개의 연료채널(fuel channel)로 구성되어 있다. 연료채널을 구성하는 압력유지 기기인 압력관(pressure tube)은 지르코니움 합금(Zr-2.5wt% Nb) 재질로서 치수는 내경이 103.4 mm, 두께가 약 4.19 mm, 길이가 6.36 m인 튜브 형태의 관이다. 압력관은 내부에 핵연료 다발과 냉각재가 내장되며 압력관의 기능은 연료를 지지하고 열수송 유체인 중수($D_2O$)를 이송한다. 압력관의 단순한 기하학적인 형상으로 인하여 자동화 비파괴검사가 가능하고 접근성이 우수하다. 연료채널은 경수로형 원전과 동일하게 설치전과 운전중에 원자력안전위원회 법령 요건에 따라 주기적으로 엄격한 비파괴검사를 수행하여 건전성을 확인한다. 연료채널의 주기적 비파괴검사에는 초음파탐상 및 와전류탐상검사 기법을 적용한 체적 비파괴검사 기술이 적용된다. 이중에서 와전류탐상검사 기법은 초음파탐상검사에서 검출된 결함의 확인을 위한 보충검사기술로 적용되고 있지만 표면결함에 대한 검출능이 초음파탐상검사 기법보다 우수한 장점을 가지고 있다. 본 논문에서는 압력관 내부 표면 비파괴검사에 적용되고 있는 와전류탐상검사 기술의 압력관 내면에 발생할 수 있는 결함의 검출 및 깊이 측정 특성에 대한 연구결과를 기술하였다. 즉, 와전류검사 기술은 압력관 내면에 발생할 수 있는 아주 미세한 결함을 매우 우수한 분해능으로 검출할 수 있으므로 초음파탐상검사 결과 확인을 위한 보충기술로서 매우 유용하지만, 결함의 깊이 측정은 오차가 매우 크게 발생하므로 결함 깊이 측정에는 적합하지 않고 오직 표면결함 검출에만 적용하는 것이 바람직하다.

Feeder Pipe Inspection Robot with an Inch-Worm Mechanism Using Pneumatic Actuators

  • Choi, Chang-Hwan;Jung, Seung-Ho;Kim, Seung-Ho
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권1호
    • /
    • pp.87-95
    • /
    • 2006
  • The outlet feeder pipe thinning in a PHWR (Pressurized Heavy Water Reactor) is caused by a high pressure steam flow inside the pipe, which is a well known degradation mechanism called a FAC (Flow Assisted Corrosion). In order to monitor the degradation, the thickness of the outlet bends close to the exit of the pressure tube should be measured and analyzed at every official overhaul. This paper describes a mobile feeder pipe inspection robot that can minimize the irradiation dose to human workers by automating the measurement process. The robot can move by itself on the feeder pipe by using an inch worm mechanism, which is constructed by two gripper bodies that can fix the robot body on to the pipe, one extendable and contractible actuator, and a rotation actuator connected to the two gripper bodies to move forward and backward, and to rotate in a circumferential direction.

Pipe Inspection Robot Using an Inch-Worm Mechanism with Embedded Pneumatic Actuators

  • Choi, Chang-Hwan;Jung, Seung-Ho;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.346-351
    • /
    • 2005
  • The outlet feeder pipe thinning in a PHWR (Pressurized Heavy Water Reactor) is caused by high pressure steam flow inside the pipe, which is a well known degradation mechanism called FAC (Flow Assisted Corrosion). In order to monitor the degradation, the thickness of the outlet bends closed to the exit of the pressure tube should be measured and analyzed at every official overhaul. This paper develops a mobile feeder pipe inspection robot that can minimize the irradiation dose of human workers by automating the measurement process. The robot can move by itself on the feeder pipe by using an inch worm mechanism, which is constructed by two gripper bodies that can fix the robot body on the pipe, one extendable and contractable actuator, and a rotation actuator connected the two gripper bodies to move forward and backward, and to rotate in the circumferential direction

  • PDF

PREDICTION OF DIAMETRAL CREEP FOR PRESSURE TUBES OF A PRESSURIZED HEAVY WATER REACTOR USING DATA BASED MODELING

  • Lee, Jae-Yong;Na, Man-Gyun
    • Nuclear Engineering and Technology
    • /
    • 제44권4호
    • /
    • pp.355-362
    • /
    • 2012
  • The aim of this study was to develop a bundle position-wise linear model (BPLM) to predict Pressure Tube (PT) diametral creep employing the previously measured PT diameters and operating conditions. There are twelve bundles in a fuel channel, and for each bundle a linear model was developed by using the dependent variables, such as the fast neutron fluences and the bundle coolant temperatures. The training data set was selected using the subtractive clustering method. The data of 39 channels that consist of 80 percent of a total of 49 measured channels from Units 2, 3, and 4 of the Wolsung nuclear plant in Korea were used to develop the BPLM. The data from the remaining 10 channels were used to test the developed BPLM. The BPLM was optimized by the maximum likelihood estimation method. The developed BPLM to predict PT diametral creep was verified using the operating data gathered from Units 2, 3, and 4. Two error components for the BPLM, which are the epistemic error and the aleatory error, were generated. The diametral creep prediction and two error components will be used for the generation of the regional overpower trip setpoint at the corresponding effective full power days. The root mean square (RMS) errors were also generated and compared to those from the current prediction method. The RMS errors were found to be less than the previous errors.

중수로 핵연료채널과 인접관의 간격측정을 위한 원거리장 와전류검사 기술개발 (Remote field Eddy Current Technique Development for Gap Measurement of Neighboring Tubes of Nuclear Fuel Channel in Pressurized Heavy Water Reactor)

  • 정현규;이동훈;이윤상;허형;정용무
    • 비파괴검사학회지
    • /
    • 제24권2호
    • /
    • pp.164-170
    • /
    • 2004
  • 중수로 내부구조물 중 칼란드리아관(CT)와 액체주입노즐관(LIN)은 서로 수평으로 90도 교차되게 배열되어 있으며 원자로 내의 열, 방사선, 하중에 의해 creep 현상이 발생되어 처짐이 일어난다. 칼란드리아관은 액체주입노즐관과 동일 재료이나 운전 온도와 방사선 조사량으로 인해 액체주입노즐관에 비해 상당히 열악한 조건에 노출되어 있으므로 처짐이 심각할 것으로 예상된다. 만약 두 관의 접촉이 발생되면 원전 안전성에 영향을 미칠 것이므로 인접관에 대한 접촉여부 점검은 중수로 안전현안 중 하나이다. 이러한 접촉여부를 확인하기 위하여 핵연료채널 내부로 탐촉자를 삽입하여 인접관과의 교차점에서 간격을 직접측정하기 위한 방법으로 원거리장 와전류검사 (RFECT) 기술을 적용하였다. 핵연료채널 인접관인 액체주입노즐관 신호 취득시 발생 가능한 잡음 신호(두께변화, Lift-off, 수축)에 대해 체적적분법에 의한 모델링으로 조사하였고, 신호와 잡음과의 분리 가능한 조건을 확인하였다. 원거리장 와전류검사 적정 조건은 민감도와 투과력 그리고 잡음신호 등을 동시에 고려하여 주파수 1kHz와 코일간격 200m로서 결정하였다. 원거리장 와전류검사 실험 결과 칼란드리아관과 액체주입노즐관 사이의 간격 변화에 대한 신호 특성을 전압평면을 이용하여 상관관계를 도출하였다.

중수로 연료관 건전성 평가시스템(WIES) 개발 (Development of an Integrity Evaluation System (WIES) for Fuel Channels in CANDU Reactors)

  • 최성남;김형남;유현주;권동기;황원걸
    • 대한기계학회논문집A
    • /
    • 제34권9호
    • /
    • pp.1273-1279
    • /
    • 2010
  • 가압중수로 연료관은 CSA N 285.4 기술기준에 따라 주기적인 가동중검사가 수행되고 있다. 가동중검사시 발견된 결함이 CSA N 285.4 의 허용기준을 초과하는 경우, 결함 연료관의 계속 운전을 위해 가동적합성 평가를 허용하고 있다. 캐나다 COG(CANDU Owner's Group)를 중심으로 중수로 연료관의 결함 건전성 평가 기술기준인 CSA N285.8 이 개발되었다. 본 논문에서는 CSA N285.8 을 기반으로 연료관의 건전성 평가시스템 WIES(Wolsong In-service Evaluation System)를 개발 하였다. 중수로 연료관의 가동중검사시 결함이 발견되는 경우, 개발된 시스템은 신속하고 정확한 건전성 평가를 수행하여 계획예방 정비기간의 연장을 방지하여 원전 이용률 향상에 기여할 것으로 판단된다.