• Title/Summary/Keyword: Pressure-time curve

Search Result 192, Processing Time 0.032 seconds

A cycle simulation of the S.I. engine and it's verification test (S.I. 엔진의 사이클 시뮬레이션 및 이의 확인 실험)

  • 목희수;김승수
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.72-84
    • /
    • 1988
  • Engine performance is one of the main objectives specified at the beginning of a new engine design project. The cycle simulation for SI engine is based on the zero-dimensional gas exchange model and a heat release expression by Viebe. This program also requires minimum input data and takes only a short time to run. Heat transfer from cylinder transfer formula. The flow coefficient (effective area) is calculated from valve lift using the standard flow coefficient curve and engine friction is calculated from the Millington and Hartles' engine friction formula. The chemical species considered in burned gas are 6 species CO, CO, H$_{2}$, H$_{2}$O, $O_{2}$, N$_{2}$ and the cylinder pressure, homogeneous cylinder temperature, gas composition and burned fraction are calculated at each crank angle through the cycle. To check the validity and accuracy, experimental study was done with 3 engines for measuring cylinder pressure, indicated mean effective pressure, brake mean effective pressure and air flow rate, etc. Despite its simple assumptions, cycle simulation showes excellent breathing and performance correlation when compared with data of tested engines, and have been proved useful in engine design.

  • PDF

Probabilistic Fracture Mechanics Analysis of Boling Water Reactor Vessel for Cool-Down and Low Temperature Over-Pressurization Transients

  • Park, Jeong Soon;Choi, Young Hwan;Jhung, Myung Jo
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.545-553
    • /
    • 2016
  • The failure probabilities of the reactor pressure vessel (RPV) for low temperature over-pressurization (LTOP) and cool-down transients are calculated in this study. For the cool-down transient, a pressure-temperature limit curve is generated in accordance with Section XI, Appendix G of the American Society of Mechanical Engineers (ASME) code, from which safety margin factors are deliberately removed for the probabilistic fracture mechanics analysis. Then, sensitivity analyses are conducted to understand the effects of some input parameters. For the LTOP transient, the failure of the RPV mostly occurs during the period of the abrupt pressure rise. For the cool-down transient, the decrease of the fracture toughness with temperature and time plays a main role in RPV failure at the end of the cool-down process. As expected, the failure probability increases with increasing fluence, Cu and Ni contents, and initial reference temperature-nil ductility transition ($RT_{NDT}$). The effect of warm prestressing on the vessel failure probability for LTOP is not significant because most of the failures happen before the stress intensity factor reaches the peak value while its effect reduces the failure probability by more than one order of magnitude for the cool-down transient.

Acoustic Properties of Three-room Coupled System by Connected Two Apertures (개구부로 연결된 3중 커플룸의 음향특성)

  • Na, Hae Joong;Lim, Byoung-Duk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.3
    • /
    • pp.340-349
    • /
    • 2016
  • A coupled room system consists of adjacent rooms and apertures where the sound energy is exchanged between the two rooms. Acoustically, a coupled room system shows a non-exponential decay profile. Most of the related researches have been to analyze the acoustic properties of two-room coupled system so far whereas three-room coupled system were seldom studied. In this regard, this paper aims to analyse the distribution of sound pressure level, sound decay curve of three-room coupled system and sound energy flow between them by using the acoustic diffusion model and to further verify them through experiments. Firstly, the sound pressure level distribution and mean sound pressure level in the steady-state condition are analyzed at various frequencies and source locations. Good agreements are observed in both experiments and analysis results. Secondly, two double slope effect quantifiers of sound attenuation, LDT/EDT and LDT/T10 are compared at various frequencies and for different source locations. The result indicates that LDT/T10, less affected by the early reflection patterns than LDT/EDT, is more suitable to the analysis and experiments of a multi-slope sound decay curve. Lastly, the sound energy flow in each room is analyzed based on the acoustic diffusion model. After the early decay stage, the sound energy is observed to flow from the room with a long reverberation time to the room with a short one.

Statistical methods for evaluating the tracking phenomenon of blood pressure (혈압의 역학적 연구와 지속성(tracking)에 대한 통계학적 분석)

  • Suh, Il;Nam, Chung-Mo;Kang, Hyung-Gon
    • The Korean Journal of Applied Statistics
    • /
    • v.6 no.2
    • /
    • pp.191-200
    • /
    • 1993
  • This study introduced speical characteristics of an epidemiologic study on blood pressure and compared several statistical methods for evaluating the tracking phenomenon of blood pressure for Korean children. While correlation coefficients adjusted for measurement error are commonly used for the evaluation of tracking, it is hard to interpretate the results when correlation functions for lag-difference are not monotonous. McMahan defined a tracking as maintenance of relative rank over time and calculated tracking index usng growth curve model. The tracking index in McMahan's model is complicate to calculate, and it is hard to determine the degree of growth curve parameter. Blomqvist showed the relationship between the rate of change and the initial value. This concept could be extended for the evaluation of tracking. However, it is not so easy to interpretate the estimates in his model when those are non-positive.

  • PDF

사출성형의 보압과정에 관한 연구

  • 이호상;전형환;한진현;설권;한창훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.46-50
    • /
    • 2001
  • Due to its ability in producing a net-shape product to high precision in a very shot cycle time, injection molding has become one of the most important polymer-processings in the industry today. Recently the CAE applications in the field of injection molding have provided significant contributions to the mold design and process optimization. As a part of such an application the packing process has been studied using C-PARK. The prediction of pressure variations during post-filling stage for amorphous material has been compared with an experimental observation for a simple rectangular geometry of uniform thickness. And the optimal packing processes were calculated using the cavity pressure curve near the gate. As a case study, a warpage simulation was carried out for a DY-HOLDER with the variable number of gates.

Behavior of the Solenoid Actuator for High-Voltage Circuit Breaker (고전압 차단기용 솔레노이드 액추에이터의 거동)

  • Yun S.;Ham Y.B.;Ahn B.K.;Kim G.D.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.1 no.3
    • /
    • pp.1-6
    • /
    • 2004
  • In the last few years, a considerable number of studies have been made on On-Off solenoid for fluid control. But, only few attempts have so far been made at solenoid actuator for high-voltage circuit breaker. In case of the high-pressure and high-flow system like high-voltage circuit breaker, a big size of On/Off solenoid is necessary which size is proportional to control pressure and flow rate. So, it is non-effective in the view point of system optimization. In this paper, On/Off solenoid actuator with the farce amplifier connected to the solenoid rod was proposed to get a high mechanical force and a fast response time. The magnetic force and the mechanical stress distributions were analysed using finite element analysis. The performances of suggested solenoid actuator were evaluated through the experimental results and compared with the analysis results.

  • PDF

Calibration of Contact Depth for Evaluating Residual Stress using Instrumented Indentation Testing (연속압입시험법을 이용한 원전구조물의 잔류응력 평가를 위한 접촉깊이의 보정)

  • Kim, Young-Cheon;Kang, Seung-Kyun;Ahn, Hee-Jun;Kim, Kwang-Ho;Kwon, Dongil
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.1
    • /
    • pp.41-47
    • /
    • 2011
  • Residual stress is the key parameter for reliability and lifetime assessment because it can reduce the fatigue strength and fracture properties of industrial structures. Recently, instrumented indentation testing (IIT) has been widely used for evaluating it, since it does not need specific specimen and time-consuming procedure. However, conventional Oliver-Pharr method, which is used for calibrating contact depth to analyze indentation load-depth curve, cannot estimate plastic pile-up between indenter and surface of specimen. Here, we introduce f parameter which is the ratio of contact depth and maximum depth, to consider pile-up height. And, its application for evaluating residual stress of weldment is introduced.

The Study of Nuclear Reactor Pressure Vessel Steel SA508Gr.3 Mechanical Properties and Temper-Parameter (원자력 압력용기용강 SA508Gr.3의 기계적 특성과 템퍼 파라메타에 관한 연구)

  • Kim, Byoung-Ok;Lee, Oh-Yeon
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.25 no.3
    • /
    • pp.121-125
    • /
    • 2012
  • The large forgings used in chemical plants or nuclear power plants are produced by complex heat treatment. because of thickness up to 200~300 mm and weight up to 200~300 ton, setting proper heat treatment cycle is so difficult. In addition, defects of products make companies wasting large money and valuable time. In this study, to reduce try & err, when setting heat treatment of reactor pressure vessel steel SA508Gr.3, carrying out the basic mechanical property test of SA508 Gr.3 and testing hardness of SA508Gr.3 in various tempering temperature. and calculating temper curve with Hollomon-Jaffe parameter.

Large Cryosorption Pump for the NBI Test Stand

  • In, S.R.;Shim, H.J.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.7 no.2
    • /
    • pp.27-32
    • /
    • 2003
  • A large cryo-pumping system composed of 4 cryosorption pumps was designed and manufactured to satisfy the pressure requirements of the NBI test stand. The cryosorption pump consists of a thermal shield/baffle assembly and a cryopanel coated with activated carbon granules. The thermal shield is cooled by liquid nitrogen, and the cryopanel by a commercial helium refrigerator. The operation characteristics and vacuum performance of the cryosorption pump were investigated. The cooling down time of the cryopanel to 20 K was about 6 hours with a liquid nitrogen consumption rate of about 35 L/hr. The maximum pumping speed of the cryosorption pump for the hydrogen gas measured by the steady pressure method was about 90,000 L/s.

  • PDF

A Novel Ocular Delivery System for Phenylephrine Hydrochloride

  • Durrani, A.M.;Jamshaid, M.;Kellaway, I.W.
    • Archives of Pharmacal Research
    • /
    • v.19 no.5
    • /
    • pp.386-389
    • /
    • 1996
  • The in vivo behaviour of phenylephrine hydrochloride in different vehicles like gels of Carbopol $907^circledR$, Carbopol $934P^circledR$ and latex system of cellulose acetate hydrogen phthalate(CAHP) was evaluated by measuring the reduction in intraocular pressure and the mydriatic activity. The parameters that haave been utilised to assess the performance of the formulations were the area under the curve (AUC), the maximum mydriasis $(I_{max})$, ethe time of maximum response $(T_{max})$ and the duration of activity (D). The influence of viscosity and mucoadhesion on the bioavailability parameters has also been investigated. Carbopol 934P and CAHP formulations showed prolonged duration of action and greater AUC compared to Carbopol 907 aqueous solution(P<0.05).

  • PDF