육상 디젤 발전소용 저속 2행정 디젤엔진의 종진동에 관한 연구 (A study of Axial Vibration of Two Stroke Low Speed Diesel Engine On the Diesel Power Plant)

  • 이돈출;고재용;유정대
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1816-1822
    • /
    • 2000
  • The maximum and mean indicated pressure of two stroke low speed diesel engine has been continuously increased with a view of increasing engine power and also reducing fuel consumption. As a result, axial excitation has been highed comparing to that of the previous and so in standard axial vibration damper is applied to all two stroke low speed diesel engine at the free end of crankshaft. Though many studies were carried out for marine use, few has been made for diesel power plant because there was little demand for power plant. Nowadays, diesel engine is much to be used for many benefits and so in this paper, the optimum design of axial vibration on the 65 MW diesel power plant with 9K80MC-S engine was carried out. And the axial-torsional coupled vibration of this shafting system is identified by theoretical analysis and vibration measurement.

  • PDF

육상 디젤 발전소용 저속 2행정 디젤엔진의 종진동에 관한 연구 (A Study of Axial Vibration of Two Stroke Low Speed Diesel Engine on the Diesel Power Plant)

  • 이돈출;남정길;고재용
    • 한국소음진동공학회논문집
    • /
    • 제11권9호
    • /
    • pp.398-405
    • /
    • 2001
  • The maximum and mean indicated pressure of two stroke low speed diesel engine has been continuously increased with a view of increasing engine power and also reducing fuel consumption. As a result, axial excitation has been increased comparing to that of the previous one. So the axial vibration damper in standard one is applied to all two stroke low speed diesel engine at the free end of crankshaft. Though many studies were carried out for marine use, few has been made for diesel power plant because there was little demand for power plant. Nowadays, diesel engine is much to be used for many benefits. In this paper, the optimum design of axial vibration on the 65 kW diesel power plant with tow 9K80MC-S engines of 9 cylinders was carried out. And the axial-torsional coupled vibration of this shafting system is identified by theoretical analysis and vibration measurement.

  • PDF

유동 양식 선도를 이용한 에어컨 실내기의 냉매 소음 저감 분석 (Experimental Study of the Refrigerant Induced Noise for Air Conditioner Using Flow Pattern Map)

  • 한형석;모진용;정의봉
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.957-963
    • /
    • 2008
  • The refrigerant-induced noise of the air conditioner is one of the irregular noises which occurs at the indoor unit. Because the air-conditioner makers are always trying to reduce the sound pressure level radiated from indoor unit, reducing the refrigerant-induced noise at low cooling mode is very important problem. But it is very difficult to estimate whether the refrigerant-induced noise occurs or not before it becomes problem. In this paper, a method to predict the refrigerant-induced noise is suggested using flow pattern map. It is estimated that the irregular noise from the refrigerant comes from the slug flow in a pipe.

  • PDF

An Experimental Study for Noise Reduction of the Cross-Flow Fan of the Room Air-Conditioners

  • Koo, Hyoung-Mo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.89-100
    • /
    • 2000
  • Present study explains some experimental results on the aerodynamic noise of the cross-flow fan usually installed in the indoor unit of the room air-conditioners and provides a simple reduction method of radiating sound to decrease the total noise level. The spectra of the noise of the cross-flow fan were analyzed by the spectral decomposition method to characterize the generated sound. The unsteady fluctuating flow field was also measured using the I-type hot-wire probe. Comparing the spectral characteristics of the sound and the flow velocity, a useful noise reduction method was proposed, which bounds the region with a fence where the flow fluctuations were noticeably changed in the same fashion as the source spectral distribution functions vary. To validate the proposed method for reducing noise generated by the cross-flow fan, the sound pressure levels of the cross-flow fan system were compared with and without the bounding fence for various flow rates.

  • PDF

에어컨용 직교류홴의 저소음화를 위한 실험적 연구 (An experimental study for noise reduction of the cross-flow fan of the room air-conditioners)

  • 구형모
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.871-879
    • /
    • 1999
  • Present study explains some experimental results on the aerodynamic noise of the cross-flow fan usually installed in the indoor unit of the room air-conditioners and provides a simple reduction method of radiating sound to decrease the total noise level. The spectrums of the noise of the cross-flow fan were analyzed by the spectral decomposition method to characterize the generated sound. The unsteady fluctuating flow field was also measured using the I-type hot-wire probe. Comparing the spectral characteristics of the sound and the flow velocity, a useful noise reduction method was proposed which bounds the region with a fence where the flow fluctuations were noticeably changed in the same fashion as the source spectral distribution functions vary. To validate the proposed method for reducing noise generated by the cross-flow fan, the sound pressure levels of the cross-flow fan system were compared of the experimental rig with and without the bounding fence for various flow rates.

  • PDF

GIS 절연 신뢰성 향상을 위한 탱크 내면 코팅이 파티클 거동에 미치는 영향 (Effect of the Inner Side Dielectric Coating of the Tank on the Particle Movement for Improving of GIS Insulation Reliability)

  • 이방욱;구자윤;김민규;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.267-269
    • /
    • 1996
  • In this work, the influence of wire type conducting particles on the insulation reliability of GIS has been systematically investigated when outer electrode was dielectric coated by epoxy resin. For this purpose, coaxial cylinder-type electrode was adopted in 362 kV chamber and various size of Cu conducting particle was used and different gas pressure was applied. To prove the coating effect on the gas insulation, different thickness of epoxy coated outer electrode have been considered and the lift-off voltage and flashover voltage have been analyzed. The results show that the dielectric coated electrode has an remarkable influence on the reducing particle behavior in GIS system and enhancing the GIS insulation reliability.

  • PDF

환자를 대상으로 마사지 중재를 적용한 국내 연구 분석 (The Analysis of Research on Massage Interventions for Patients in Korea)

  • 노영숙;김소선;김종일
    • 임상간호연구
    • /
    • 제15권3호
    • /
    • pp.171-182
    • /
    • 2009
  • Purpose: The purpose of this study was to find out the research trend and analyze the evidence of research on massage interventions for patients in Korea. Methods: Literature database search from 2003 to 2008 was carried out including KSTUDY, RICHIS, RISS4U, and NANET using the following MeSH terms: massage and patients. Results: A total of 51 articles registered in Korea Research Foundation were reviewed for analysis. Major participants of the studies were patients with cancer, surgery patients, stroke patients, and preterm babies. The outcome variables most commonly measured were blood pressure, state anxiety, and pain. While massage intervention was reported having a significant effect on lowering anxiety and pain, the other effects of massage in patients were inconsistent. Conclusion: Massage intervention has evidence-based effects on reducing anxiety and pain in patients. A larger body of methodologically sound research is needed to verify the multidimensional effects of massage.

입자상물질과 Ash양이 디젤매연여과장치 내의 배압 및 유동균일도에 미치는 영향 (Effect of Particulate Matter and Ash Amount on Pressure Drop and Flow Uniformity of Diesel Particulate Filter Reduction System)

  • 김윤지;한단비;서태원;오광철;백영순
    • 청정기술
    • /
    • 제26권1호
    • /
    • pp.22-29
    • /
    • 2020
  • 최근 미세먼지 증가로 인하여 디젤엔진의 배출 규제가 강화됨에 따라 디젤 매연여과장치에 관심이 급증하게 되었으며, 특히 디젤 배기가스 후처리 장치의 고효율화에 대한 기술개발이 더욱 요구되고 있다. 이에 대한 일환으로서 디젤매연여과장치(diesel particulate filter, DPF) 내 배기가스의 유동 균일도를 향상시키고 배압을 낮추어서 배기가스처리 효율을 높이는 연구가 많이 되고 있다. 본 연구에서는 ANSYS Fluent를 이용하여 직경 12"의 DPF와 디젤산화촉매(diesel oxidation catalyst, DOC)를 장착한 디젤 매연여과장치에서의 배기가스의 유속과 온도, DPF IO ratio, Ash와 PM양에 따른 배압에 미치는 영향을 시뮬레이션 하여 배압을 낮추는 최적화 연구를 하였다. 결과로서 배기가스의 온도와 유속이 낮을수록 배압이 낮아졌으며, PM양이 Ash양보다 배압에 더 큰 영향을 주는 것으로 나타냈다. 또한 비대칭 DPF가 대칭 DPF에 비해 배압이 더 낮게 나타냈으나, 유동 균일도의 경우는 다양한 변수에 관계없이 일정하게 나타냈다. european stationary cycle (ESC), european transient cycle (ETC) 조건에서 PM의 정화효율은 비대칭, 대칭 DPF 관계없이 유사하나, particle number (PN)의 정화효율에서는 비대칭 DPF가 대칭 DPF에 비해 높게 나타냈다.

전기집진기 예지보전 단계에서의 고장모드영향분석 (FMEA of Electrostatic Precipitator for Preventive Maintenance)

  • 한승훈;이정욱;이선엽;황종덕;강대곤
    • 해양환경안전학회지
    • /
    • 제26권6호
    • /
    • pp.706-714
    • /
    • 2020
  • 전 세계 90 %의 인구가 WHO의 연평균 미세먼지 노출 기준(10 ㎍/㎥)을 초과한 공기를 흡입하고 있다. 전 세계적으로 육상뿐만 아니라 해양에서 발생하는 질소산화물에 대한 규제를 통해 2차 오염물질, 초미세먼지 저감에 대해 노력하고 있으며 국내에서는 선박에서 미세먼지 발생의 주요한 원인인 황 함유량 저감과 환경친화적 선박의 개발 및 보급 등을 통해 깨끗한 해양환경 조성을 위한 노력을 하고 있다. 디젤엔진 유해 배출가스 저감을 위한 기술 중 압력 손실이 적고 높은 집진 효율 및 NOx의 제거와 유지 관리의 장점이 많은 전기 집진기의 수요와 중요성이 증가하고 있다. 본 연구는 총톤수 999톤급 선박의 2,427 kW 선박용 디젤엔진의 미세먼지 저감을 목적으로 개발된 전기 집진기를 예지보전단계에서 고장모드영향분석을 통해 장비 품질을 높여 선박 내에서의 내구연한을 높이고자 위험 우선순위 도출하였다. 위험 우선순위는 고장모드 241(poor dust capture efficiency)이 RPN 180으로 가장 높았다. Collecting electrode에서 가장 많은 고위험 고장모드를 검출하여 집중관리 부품으로 관리해야 할 필요가 있었으며 원인으로 진동과 핀 풀림으로 인한 유격 불량이 가장 많이 검출되었다. 핀 풀림 역시 근본적으로는 선체 또는 장비에서 발생하는 진동이 원인이 되어 발생할 수 있는 사항이기 때문에 핀 풀림이 발생하는 개소에 보완이 필요하겠다.

모듈레이팅 밸브 및 유압 클러치의 설계 변수가 전후진 파워시프트 변속기의 변속 품질에 미치는 영향 (Effect of Design Parameters of Modulating Valve and Hydraulic Clutch on Shift Quality of a Power Shuttle Transmission)

  • 김경욱;정병학;박영준
    • Journal of Biosystems Engineering
    • /
    • 제28권3호
    • /
    • pp.187-198
    • /
    • 2003
  • This study was conducted to investigate the effect of design parameters of modulating valve and hydraulic clutch on the shift quality of a power shuttle transmission using a computer simulation. Computer simulation models of a hydraulic control system and a power shuttle drive train were developed and verified by an experimental power train in a laboratory. The software EASY5 was used for the modeling and simulation of the power shuttle transmission. Results of the study were summarized as follows: For a good shift quality. it is required to reduce the transient torque transmitted to the output shaft of the transmission as much as possible. This may be achieved by reducing the modulating time and clutch pressure. It was found that the design parameters most significantly affecting the modulating time and clutch pressure were the spring constant and displacement of a load piston of the modulating valve, and the spring constant and damping of the clutch piston. The modulating time decreased as the spring constant increased and increased as the displacement of the load piston decreased. The transient torque decreased as the modulating time increased. However their relationships were not always linear. As the damping decreased, both the modulating pressure and time decreased, which also resulted in a decrease in the transient torque. The spring constant of the clutch piston affected the modulating time and the peak transient torque. As the spring constant of the clutch increased, the peak transient torque decreased.