• Title/Summary/Keyword: Pressure-Drop

Search Result 2,340, Processing Time 0.029 seconds

DECREASE OF OXYGEN SATURATION DURING DENTAL TREATMENT UNDER GENERAL ANESTHESIA OF DOWN SYNDROME PATIENT WITH CONGENITAL HEART DISEASE -A CASE REPORT- (선천성 심장질환을 가진 다운증후군환자에서 치과치료를 위한 전신마취 시 산소포화도 하강 -증례보고-)

  • Seo, Kwang-Suk;Chang, Ju-Hea;Shin, Teo-Jeon;Kim, Hyun-Jeong
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.5 no.1
    • /
    • pp.18-22
    • /
    • 2009
  • A 26-year-old female patient with Down syndrome visited to recieve dental treatment under gnenral anesthesia 6 years ago. The patient had difficulties in oral examination, radiograph taking and laboratory test. The patient had congenital heart disease and medical consultation based on the echocardiography was provided by a cardiologist indicating that the patient could tolearte general anesthesia during dental treatment. And two times of general anesthesia were administered during a dental treament with the interval of 3 years and no postoperpative complicaton was reported. At the third dental operation, the patient had a relatively good condition and her prescreening test revealed no abnormalities. Without further consultation with a cardiologist, general anesthesia was administered to the patient. Anaesthesia was based on thiopental and ventilation of desflurane and $N_2O$ in oxygen via an endotracheal tube with an appropriate monitoring. During the maintenance of anesthesia, the blood pressure of the patient started to drop and the oxygen saturation also began to decrease. Consequently, the proceding operation was discontinued and also inhalation anesthesia was ceased. As the patient was recovered from anesthesia, her systemic conditions were alleviated. After the complete recovery of the patient, she visited the cardiologist, and the cardiologic test revealed her severe right ventricular dilatation. In the anesthesia of patients with congenital heart disease, information on their systemic conditions needs to be undated from the medical consultation, which assures the safety of treatment.

  • PDF

Effectiveness of Photocatalytic Techniques for Disinfection of Indoor Bioaerosols (실내 미생물 입자 살균을 위한 광촉매 기술의 효율)

  • Shin, Seoung-Ho;Kim, Mo-Geun;Jo, Wan-Kuen
    • Journal of Environmental Science International
    • /
    • v.16 no.7
    • /
    • pp.785-791
    • /
    • 2007
  • The current study evaluated the technical feasibility of the application of titanium dioxide ($TiO_{2}$) photo-catalytic air cleaners for the disinfection of bioaerosols present in indoor air. The evaluation included both laboratory and field tests and the tests of hydraulic diameter (HD) and lamp type (LT). Disinfection efficiency of photocatalytic oxidation (PCO) technique was estimated by survival ratio of bacteria or fungi calculated from the number of viable cells which form colonies on the nutrient agar plates. It was suggested that the reactor coating with $TiO_{2}$ did not enhance the adsorption of bioaerosols, and that the UV irradiation has certain extent of disinfection efficiency. The disinfection efficiency increased as HD decreased, most likely due to the decrease in the light intensity since the distance of the catalyst from the light source increased when increasing the HD. It was further suggested that the mass transfer effects were not as important as the light intensity effects on the PCO disinfection efficiency of bioaerosols. Germicidal lamp was superior to the black lamp for the disinfection of airborne bacteria and fungi, which is supported by the finding that the disinfection efficiencies were higher when the germicidal lamp was used compared to the black lamp in the laboratory test. These findings, combined with operational attributes such as a low pressure drop across the reactor and ambient temperature operation, can make the PCO reactor a possible tool in the effort to improve indoor bioaerosol levels.

A Case Study on Meteorological Analysis of Freezing Rain and Black Ice Formation on the Load at Winter (겨울철 노면에 발생하는 어는 비와 블랙아이스의 기상학적 분석에 관한 사례 연구)

  • Park, Geun-Yeong;Lee, Soon-Hwan;Kim, Eun-Ji;Yun, Byeong Yeong
    • Journal of Environmental Science International
    • /
    • v.26 no.7
    • /
    • pp.827-836
    • /
    • 2017
  • Freezing rain is a phenomenon when precipitation falls as a liquid rain drop, but freezes when it comes into contact with surfaces or objects. In this study, we investigated the predictability of freezing rain and its characteristics, which are strongly related with the occurrence of black ice using synoptic scale meteorological observation data. Two different cases occurred at 2012 were analyzed and in the presented cases, freezing rain often occurs in the low-level low pressure with the warm front. The warm front due to the lower cyclone make suitable environment in which snow falling from the upper layer can change into supercooled water. The $0^{\circ}C$ temperature line to generate supercooling water is located at an altitude of 850 hPa in the vertical temperature distribution. And the ground temperature remained below zero, as is commonly known as a condition for black ice formation. It is confirmed that the formation rate of freezing rain is higher when the thickness after 1000-850 hPa is 1290-1310 m and the thickness of 850-700 hPa layer is larger than 1540 m in both cases. It can also be used to predict and estimate the generation of freezing rain by detecting and analyzing bright bands in radar observation.

Effects of Bleeding on Heat/Mass Transfer in a Rotating Channel with Transverse Ribs (90도 요철이 설치된 회전덕트에서 유출이 열/물질전달에 미치는 영향)

  • Park, Suk-Hwan;Jeon, Yun-Heung;Kim, Kyung-Min;Lee, Dong-Hyun;Cho, Hyung-Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.1 s.34
    • /
    • pp.25-31
    • /
    • 2006
  • The present study investigates the effects of bleed flow on heat/mass transfer and pressure drop in a rotating channel with transverse rib turbulators. The hydraulic diameter $(D_h)$ of the square channel is 40.0mm. The bleed holes are located between the rib turbulators on leading surface and the hole diameter (d) is 4.5 mm. The square rib turbulators are installed on both leading and trailing surfaces. The rib-to-rib pitch is 10.0 times of the rib height(e) and the rib height-to-hydraulic diameter ratio $(e/D_h)$ is 0.055. The tests were conducted at various rotation numbers (0, 0.2, 0.4), while the Reynolds number and the rate of bleed flow to main flow (BR) were fixed at 10,000 and $10\%$, respectively. The results suggest that the heat/mass transfer characteristics in the internal cooling passage are influenced by rib turbulators, bleed flow and the Coriolis force induced by rotation. For the rotating ribbed passage with bleed flow, the heat/mass transfer on the leading surface is hardly affected by bleed flow, but that on the trailing surface decreases due to the diminution of main flow. The results also show that the friction factor decreases with the bleed flow.

Improved Control Algorithm Development for Control Element Drive Mechanism Control System (제어봉구동장치제어계통의 개선된 제어 알고리즘 개발)

  • Kim, Byeong-Moon;Lee, Young-Ryul;Han, Jae-Bok;You, Joon
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.761-765
    • /
    • 1995
  • The old Timing Controller for Control Element Drive Mechanism (CEDM) is designed as an open loop control system because it is difficult to mount sensors within the Control Element Drive Mechanism(CEDM) which is operating under the pressure boundary of the reactor vessel. In this work new method which can be used to detect the CEDM operational conditions without mounting sensors within the CEDM housing is developed in order to resolve problems of the old Timing Controller. By using the developed new method, the new Timing Controller for the CEDM is designed as a closed loop controller which has features of the control rod drop prevention, fine position control and the coil life time extension. The algorithm developed under closed loop control concept resolves most problems occurred in the old Timing Controller and improves the performance and reliability of the system. During designing and testing of the Timing Controller algorithm, the real time CEDM simulator developed here was used. And all functions of the developed algorithm were verified using CEDM simulator with the real data collected from the site. The results show that the Timing Controller performs its intended functions properly.

  • PDF

Development of Membrane Filter with Nanostructured Porous Layer by Coating Metal Nanoparticles onto a Micor-Filter (마이크로-필터 상에 금속 나노입자 코팅에 의한 나노구조 기공층 멤브레인 필터 개발)

  • Lee, Dong Geun;Park, Seok Joo;Park, Young Ok;Ryu, Jeong In
    • Korean Chemical Engineering Research
    • /
    • v.45 no.6
    • /
    • pp.591-595
    • /
    • 2007
  • The membrane filter coated with nanostructured porous surface layer was made by heat treatment after depositing nanoparticles onto a conventional micron-fibrous metal filter as a substrate filter. The nanostructured porous layer membrane filter (NSPL-MF), whose the filtration performance was improved compared with the conventional metal membrane filters, was developed by coating the nanoparticle agglomerates of dendrite structure onto the micron-fibrous metal filter. Pressure drop of nanostructured porous layer membrane filter decreased with increasing the heat treatment temperature to make the nanostructured porous layer adhered on the filter surface because the nanoparticle agglomerates shrank, but filtration efficiency did not decrease clearly.

An Experimental Study of Evaporative Heat Exchangers with Mini-channels (물의 증발잠열을 이용하는 미니채널 열교환기의 실험적 연구)

  • Lee, Hyung-Ju;Yoo, Young-June;Min, Seong-Ki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.245-253
    • /
    • 2010
  • The present study shows some results of developing evaporative heat exchangers with mini-channels. Heat exchangers with three different water paths were manufactured and tested to compare performances of cooling and pressure drop. Among the three types of heat exchangers, Type 2 with full-etching was proved to be the best in the cooling performances for considered operating conditions, and thus it is recommended to adopt Type 2 for its simplicity of production and outstanding performance. However, Type 1 was shown to be better when it is operated at a high air inlet temperature condition. The developed evaporative heat exchanger will be installed in Environmental Control Systems(ECSs) for aerial vehicles, and it can be used effectively in case an ECS is not only limited in its weight and volume but also required to absorb heats without supplying water (or a coolant) for a certain period of time.

  • PDF

Characteristics of the Onset of Flooding for Countercurrent Air-Water Flow in Vertical Annuli with a Direct Injection Mode (수직 환상관내 반류 공기-물 유동에서 직접분사방식에 따른 플러딩 시작점 특성)

  • Lee, S.C.;Shin, I.H.;Lee, S.M.;Chung, M.;Kim, D.S.;Chang, W.P.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.266-274
    • /
    • 1996
  • An experimental work was conducted to investigate the characteristics of the onset of flooding in vertical annuli with a direct injection mode using air and water. The onset of flooding was determined by means of pressure drop measurement while the air velocity was increased gradually under fixed liquid flow rates. Data of the onset of flooding were collected for various combinations of the tube size and the nozzle number. A theoretical analysis of the onset of flooding was also performed based on an envelope theory. The result shows that the onset of flooding in small-scale annuli can be predicted relatively well by the theory. A modified Wallis parameter was used to investigate the scaling effect of flooding phenomena in the annuli, indicating a relatively reasonable result. The number of nozzle has no effect on the flooding velocity when liquid was injected through 2, 3, 4 and 6 nozzles but the initiation of flooding was significantly expedited when 12 nozzles were employed for liquid injection.

Study on Design Change of a Pipe Affected by Liquid Droplet Impingement Erosion (액적충돌침식 영향 배관의 설계변경에 관한 연구)

  • Hwang, Kyeong-Mo;Lee, Chan-Gyu;Bhang, Keug-Jin;Yim, Young-Sig
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.10
    • /
    • pp.1097-1103
    • /
    • 2011
  • Liquid droplet impingement erosion (LDIE) is caused by the impact of high-velocity droplets entrained in steam or air on metal. The degradation caused by the LDIE has been experienced in steam turbine internals and high-velocity airplane components (particularly canopies). Recently, LDIE has also been observed in the pipelines of nuclear plants. LDIE among the pipelines occurs when two-phase steam experiences a high pressure drop (e.g., across an orifice in a line to the condenser). In 2011, a nuclear power plant in Korea experienced a steam leak caused by LDIE in a pipe through which a two-phase fluid was flowing. This paper describes a study on the design change of a pipe affected by LDIE in order to mitigate the damage. The design change has been reviewed in terms of fluid dynamics by using the FLUENT code.

RELAP5/MOD3 Analysis for Hydraulic Load Calculation of the SEBIM POSRV Discharge Riping System (SEBIM POSRV 방출배관계통의 수력학적 하중계산을 위한 RELAP5 / MOD3 분석)

  • Han, Kee-Soo;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.225-236
    • /
    • 1994
  • The sudden discharge of the loop seal water, which is present upstream of the SEBIM POSRV, creates large momentum and inertia forces on the downstream of the discharge piping system. This study provides the procedures and results of analysis of the thermal-hydraulic transient in the SEBIM POSRV discharge piping during the valve opening. The analysis is peformed by RELAP5/MOD3. The appropriate modeling of the discharge piping system, SEBIM POSRV opening characteristics, and loop seal water discharge for the RELAP5/MOD3 analysis is suggested. Also performed is the sensitivity study for the selection of proper options for the junction and volume control. flags. The analysis results demonstrate the adequacy of the RELAP5/HOD3 for the thermal-hydraulic transient analysis of the loop seal water discharge of the SEBIM POSRV discharge piping system. From the sensitivity analysis results, it is shown that the smooth area change option with reasonable geometric pressure drop distribution, non-equilibrium option, and proper time step should be selected for loop seal water discharge analysis.

  • PDF