• Title/Summary/Keyword: Pressure valve

Search Result 1,789, Processing Time 0.033 seconds

An Experimental Study on Evaporation/Condensation Heat Transfer with Flow Direction in Brazed Plate Heat Exchanger using Refrigerant 410A (R410A를 이용한 브레이징 타입 판형열교환기에서 물 측 유동방향에 따른 응축/증발 성능 평가)

  • Lee, Sung-Woo;Jeong, Young-Man;Lee, Jae-Keun;Lee, Dong-Hyuk
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1096-1101
    • /
    • 2009
  • The plate heat exchanger(PHE) in heat pump has two flow streams of the refrigerant and water. The flow direction of the refrigerant, unlike that of water, can be changed by a 4-way valve depending on operating condition. Therefore the flow arrangement is a parallel flow for heating and a counter flow for cooling, respectively. In this study, the effects of the flow direction of the water on the heat transfer rate are investigated experimentally. The experiments are carried out for brazed plate heat exchangers under a parallel and counter flow conditions in evaporation and condensation. The experimental parameters in this study include the mass flux of the refrigerant 410A from 3 to $14\;kg/m^2s$ and the flow patterns for the pressure of PHE fixed at 0.97 and 2.46 MPa. The results show that both the heat transfer rate and frictional pressure drop across the PHE increase with the mass flux. The heat transfer rate of the refrigerant 410A for evaporation show great sensitivity to flow direction of the water. The heat transfer rate for evaporation with a counter flow are 5-30% higher than that with a parallel flow.

  • PDF

Property Prediction of Rupture Disc by Using Finite Element Analysis (유한요소해석을 이용한 파열판의 특성 예측)

  • Han, Chang-Yong;Lee, Seong-Beom;Jung, Hee-Suk;Kim, Tae-Gu
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.3
    • /
    • pp.1-6
    • /
    • 2009
  • High pressure devices are used widely. Interest in rupture disc to people is the increases in protect of facilities and people. A rupture disc consists of mainly three parts: holder, plate and vacuum support. Rupture discs are rusted or destroyed by diverse environments. Rupture discs are made from STS 316L stainless steel because of its high corrosion resistance and yield strength. In this study, modeling of a rupture disc by CATIA V5 and finite element analysis by ANSYS were carried out. The finite element analysis results executed to predict properties of the rupture disc with thickness and height.

  • PDF

Development of a Non-contact Liquid Dispenser for High Contents Screening System (세포 기반 고집적 스크리닝 시스템용 비접촉식 고정밀 마이크로 디스팬서 제작)

  • Cho, Seong J.;Kim, Intae;Lim, Geunbae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.6
    • /
    • pp.581-585
    • /
    • 2016
  • Nowadays medical treatment service increase due to ageing population and improving the quality of life. Accordingly it is predicted that drug discovery market will expansion continuously. Therefore it is necessary that profit creation by drug discovery on the global market is important. HCS(High Contents Screening) has been emerging as a potential method to solve problems of the present drug discovery. This research is about liquid dispenser for HCS. The purpose of this research is to manufacture high performance liquid dispenser for HCS. The dispenser is designed to control 5 liquids separately. The liquid contact parts are designed disposably, biocompatibly and chemically inertly. Air curtain is equipped at the side of tip to dispense very small liquid volume and to prevent hanging drop on tip. Valving is performed by just controlling the pressure of the pressure driven pump without valve.

Experimental Analysis on the Performance of a Solar Powered Water Pump (태양열 물펌프의 실험적 성능분석)

  • Kim Y. B.;Son J. G.;Lee S. K.;Kim S. T.;La W. J.;Lee Y. K.
    • Journal of Biosystems Engineering
    • /
    • v.29 no.6 s.107
    • /
    • pp.521-530
    • /
    • 2004
  • The solar powered water pump is very ideal equipment because solar power is more intensive when the water is more needed in summer and it is very helpful in the rural area, in which electrical power is not available. The average solar radiation power is $3.488\;kWh/(m^2{\cdot}day)$ in Korea. In this study, the experimental system of the water pump driven by the radiation energy were designed, assembled, tested and analyzed fur realizing the solar powered water pump. Energy conversion ken radiation energy to mechanical energy by using n-pentane as operating material was done and the water pumping cycles were able to be continued. The quantity of the water pumped per cycle ranged from 2 L to 10 L depending on the level of the valve open area far the vapour supply. The average quantity was about 4,366 cc. The thermal efficiency was about $0.018\%$. The pressure level of the n-pentane vapour in flash tank was about $110\~150\;kPa$ and that in the water tank was $93\~130\;kPa$. The pressure in the condenser during cycles was maintained as about 70 kPa. The condensation of the n-pentane vapour in the water tank was increased with the cycles even though the internal and external insulation were done. Air tank performance was better with increasing of the water piston displacement and the water could be pumped with the water piston displacement becoming higher than 6,500 cc.

Application of Levenberg Marquardt Method for Calibration of Unsteady Friction Model for a Pipeline System (관수로 부정류 마찰항 보정을 위한 Levenberg Marquardt 방법의 적용연구)

  • Park, Jo Eun;Kim, Sang Hyun
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.4
    • /
    • pp.389-400
    • /
    • 2013
  • In this study, a conventional pipeline unsteady friction model has been integrated into Levenberg Marquardt method to calibrate friction coefficient in a pipeline system. The method of characteristics has been employed as the modeling platform for the frequency dependant model of unsteady friction. In order to obtain Hessian and Jacobian matrix for optimization, the direct differentiation of pressure to friction factor was calculated and sensitivities to friction for heads and discharges were formulated for implementation to the integration constant in the characteristic method. Using a hypothetical simple pipeline system, time series of pressure, introduced by a sudden valve closure, were obtained for various Reynolds numbers. Convergency in fiction factors were evaluated both in steady and unsteady friction models. The comparison of calibration performance between the proposed method and genetic algorithm indicates that faster and stabler behaviour of Levenberg Marquardt method than those of evolutionary calibration.

A Study on Tracking Position Control of Pneumatic Actuators Using Neural Network (신경회로망을 이용한 공압구동기의 위치 추종제어에 관한 연구)

  • Gi Heung Choi
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.3
    • /
    • pp.115-123
    • /
    • 2000
  • Pneumatic actuators are widely used in a variety of hazardous working environments. Any process that involves pneumatic actuation is also recognized as "eco-friendly". In most cases, applications of pneumatic actuators require only point-to-point control. In recent years, research efforts have been directed toward achieving precise position tracking control. In this study, a tracking position control method is proposed and experimentally evaluated for a linear positioning system. The positioning system is composed of a pneumatic actuator and a 3-port proportional valve. The proposed controller has an inner pressure control loop and an outer position control loop. A PID controller with feedback linearization is used in the pressure control loop to nullify the nonlinearity arising from the compressibility of the air. The position controller is also a PID controller augmented with the friction compensation by a neural network. Experimental results indicate that the proposed controller significantly improves the tracking performance.rformance.

  • PDF

Surgical Correction of Tetralogy of Fallot in Adults - 101 Cases Report - (성인 활로씨 4징증 수술치험 101예 보고)

  • 조범구
    • Journal of Chest Surgery
    • /
    • v.21 no.4
    • /
    • pp.649-655
    • /
    • 1988
  • One hundred and one patients with tetralogy of Fallot who were older than 16 years of age underwent a total correction of the anomaly between May, 1964 and July, 1987. This group comprised 14.9% of the 679 consecutive patients who had repair of the tetralogy at our institution during the same period. Of the 101 patients, 8 had a previous shunt procedure for palliation. The preoperative mean hemoglobin value was 16.9*1.0% and the mean systemic oxygen saturation, 84.4*0.9%. In 76 patients[75.2%], a type II ventricular septal defect was seen whereas in 14 patients[13.9%], the defect was type I. In 72 patients[71.3%], other cardiac anomalies were present which included patent foramen ovale in 37.6%, atrial septal defect in 8.99b, vegetations in 6.9%, right sided aortic arch in 5.9% and coronary artery anomaly in 5.0%. The right ventricular outflow obstruction was caused most commonly by combination of infundibular and valvular stenosis[74.3%], followed by isolated infundibular stenosis[19.8%] and valvular stenosis [5.9%] alone in order. The preoperative mean diameter of the pulmonary valve ring size was 10.2*0.5 mm in diameter. A transannular patch enlargement of the right ventricular outflow tract was performed in 28 patients and, in 12 a pericardial monocusp was utilized. Major anomalous aorto-pulmonary vessels were encountered in 5 patients which were detected before or during the operation. In 3 patients, they were ligated beforehand to control the flooding of the operative field. Postoperatively, the mean systolic pressure gradient between the right ventricle and the main pulmonary artery was 16.2*2.3 mmHg and the mean systolic pressure- ratio between the right and the left ventricle was 45.3*2.0%. Perioperative complications including bleeding in 8.9%, pleural effusion in 7.9%, dysrrhythmia in 4.9%, and residual VSD in 4.0%. Operative mortality was 8.9%. There has been no operative death in the recent 65 cases since 1981. There were 2 late deaths, 68 and 113 months after surgery. There were 2 late detachment of the VSD patch during the follow-up period. Of the 6 patients with patch detachment found during the postoperative period, 3 had subacute bacterial endocarditis before or after the operation indicating The serious nature of this complication. Two of these patients subsequently underwent a successful reoperation.

  • PDF

Acute Pulmonary Thromboembolism: 14 Years of Surgical Experience

  • Park, Jiye;Lim, Sang-Hyun;Hong, You Sun;Park, Soojin;Lee, Cheol Joo;Lee, Seung Ook
    • Journal of Chest Surgery
    • /
    • v.52 no.2
    • /
    • pp.78-84
    • /
    • 2019
  • Background: Pulmonary thromboembolism (PTE) is a life-threatening disease with high mortality. This study aimed to assess the outcomes of surgical embolectomy and to clarify the sustained long-term effects of surgery by comparing preoperative, postoperative, and long-term follow-up echocardiography outcomes. Of 22 survivors, 21 were followed up for a mean (median) period of $6.8{\pm}5.4years$ (4.2 years). Methods: We retrospectively reviewed 27 surgical embolectomy cases for massive or submassive acute PTE from 2003 to 2016. Immediate and long-term follow-up outcomes of surgical embolectomy were assessed on the basis of 30-day mortality, long-term mortality, postoperative complications, right ventricular systolic pressure, and tricuspid regurgitation grade. Results: The 30-day and long-term mortality rates were 14.8% (4 of 27) and 4.3% (1 of 23), respectively. Three patients had major postoperative complications, including hypoxic brain damage, acute kidney injury, and endobronchial b leeding, respectively (3.7% each). Right ventricular systolic pressure (median [range], mm Hg) decreased from 62.0 (45.5-78.5) to 31.0 (25.7-37.0, p<0.001). The tricuspid valve regurgitation grade (median [range]) decreased from 1.5 (0.63-2.00) to 0.50 (0.50-1.00, p<0.05). The improvement lasted until the last echocardiographic follow-up. Conclusion: Surgical embolectomy revealed favorable mortality and morbidity rates in patients with acute massive or submassive PTE, with sustained long-term improvements in cardiac function.

Prediction of air inflow during central venous catheter insertion: experimental study (중심정맥관 삽입 시 발생하는 공기유입량의 예측: 실험연구)

  • Jung, Hyo Jae;Kim, Yang Weon;Park, Chang Min;Park, Chul Ho;Kang, Ji Hun;Yoon, Yoo Sang
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.641-648
    • /
    • 2018
  • Objective: This study examined the incidence and amount of air inflow during central venous catheter (CVC) insertion. Methods: This study was an experimental study aimed at designing an apparatus to implement blood vessel and blood flow in the human body. A 1.5-m long core tube with a Teflon tube, suction rubber tube, and polyvinyl chloride tube were made. This core tube was assumed to be the blood vessel of the human body. Blood was replaced with a saline solution. The saline solution was placed higher than the core tube and flowed into the inside of the tube by gravity. The CVC was injected 15-cm deep into the core tube. The air was collected through a 3-way valve into the upper tube. The experiments were carried out by differentiating the pressure in the tube, CVC insertion step, and diameter of the end of the catheter. The experiment was repeated 10 times under the same conditions. Results: The amount of air decreased with increasing pressure applied to the tube. Air was not generated when the syringe needle was injected, and the amount of air increased with increasing size of the distal end catheter. Conclusion: To minimize the possibility of air embolism, it is necessary to close the distal end catheter at the earliest point as soon as possible.

A study on the dynamic characteristics of the secondary loop in nuclear power plant

  • Zhang, J.;Yin, S.S.;Chen, L.;Ma, Y.C.;Wang, M.J.;Fu, H.;Wu, Y.W.;Tian, W.X.;Qiu, S.Z.;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1436-1445
    • /
    • 2021
  • To obtain the dynamic characteristics of reactor secondary circuit under transient conditions, the system analysis program was developed in this study, where dynamic models of secondary circuit were established. The heat transfer process and the mechanical energy transfer process are modularized. Models of main equipment were built, including main turbine, condenser, steam pipe and feedwater system. The established models were verified by design value. The simulation of the secondary circuit system was conducted based on the verified models. The system response and characteristics were investigated based on the parameter transients under emergency shutdown and overload. Various operating conditions like turbine emergency shutdown and overspeed, condenser high water level, ejector failures were studied. The secondary circuit system ensures sufficient design margin to withstand the pressure and flow fluctuations. The adjustment of exhaust valve group could maintain the system pressure within a safe range, at the expense of steam quality. The condenser could rapidly take out most heat to avoid overpressure.