• Title/Summary/Keyword: Pressure shock

Search Result 1,013, Processing Time 0.029 seconds

Irradiation of Intense Characteristic X-rays from Weakly Ionized Linear Plasma

  • Sato, Eiichi;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.396-399
    • /
    • 2002
  • Intense quasi-monochromatic x-ray irradiation from the linear plasma target is described. The plasma x-ray generator employs a high-voltage power supply, a low-impedance coaxial transmission line, a high-voltage condenser with a capacity of about 200 nF, a turbo-molecular pump, a thyristor pulse generator as a trigger device, and a flash x-ray tube. The high-voltage main condenser is charged up to 55 kV by the power supply, and the electric charges in the condenser are discharged to the tube after triggering the cathode electrode. The x-ray tube is of a demountable triode that is connected to the turbo molecular pump with a pressure of approximately 1 mPa. As electron flows from the cathode electrode are roughly converged to the molybdenum target by the electric field in the tube, the weakly ionized plasma, which consists of metal ions and electrons, forms by the target evaporating. In the present work, the peak tube voltage was almost equal to the initial charging voltage of the main condenser, and the peak current was about 20 kA with a charging voltage of 55 kV. When the charging voltage was increased, the linear plasma x-ray source grew, and the characteristic x-ray intensities of K-series lines increased. The quite sharp lines such as hard x-ray lasers were clearly observed. The quasi-monochromatic radiography was performed by a new film-less computed radiography system.

  • PDF

Study on Flow Characteristics and Discharge Coefficient of Safety Valve for LNG/LNG-FPSO Ships (LNG / LNG-FPSO 선박용 안전밸브의 유동특성 및 유출계수에 관한 연구)

  • Kim, Sung-Jin;Jung, Sung-Yuen;Kim, Dang-Ju;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.5
    • /
    • pp.487-494
    • /
    • 2011
  • The safety valve used in LNG/LNG-FPSO ships plays an important role in maintaining a fixed level of pressure by emitting LNG gas out of the pipes in the LNG piping system. The discharge coefficient is regarded as the most important factor in the valve performance. To satisfy the ship's classification, the discharge coefficient of the safety valve must usually be over 0.8. Despite the importance of understanding the flow phenomena inside the safety valve, the valve design is usually based on experience and experiments. We carried out a computational fluid dynamics (CFD) investigation using the ANSYS-CFX software. We observed the flow phenomena inside the valve and measured the discharge coefficients according to changes in the valve lift, which is the distance between the exit of the nozzle and the lower part of the disc plate. We verified our CFD results for the discharge coefficients using available experimental data.

Control of Plume Interference Effects on a Missile Body Using a Porous Extension (다공확장벽을 이용한 미사일 동체에 대한 플룸간섭 현상의 제어)

  • Young-Ki Lee;Heuy-Dong Kim
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.4
    • /
    • pp.33-38
    • /
    • 2003
  • The Physics of the Plume-induced shock and separation Particularly at a high Plume to exit pressure ratio and supersonic speeds up to Mach 3.0 with and without a passive control method, porous extension, were studied using computational techniques. Mass-averaged Navier-Stokes equations with the RNG $\kappa$-$\varepsilon$ turbulence model were solved using a fully implicit finite volume scheme and a 4-stage Runge-Kutta method. The control methodology for plume-afterbody interactions is to use a perforated wall attached at either the nozzle exit or the edge of the missile base. The Effect of porous wall length on plume interference is also investigated The computational results show the main effect of the porous extension on plume-afterbody interactions is to restrain the plume from strongly underexpanding during a change in flight conditions. With control, a change in porous extension length has no significant effect rut plume interference.

The Effect of Different Particle Size from PAHs Contaminated Sediment by Ultrasonic Irradiation (PAHs로 오염된 침전물의 초음파 처리시 입자크기가 미치는 영향)

  • Na, Seung-Min;Khim, Jee-Hyeong;Cui, Ming-Can;Ahn, Yun-Gyong;Weavers, Linda K.
    • Journal of Environmental Science International
    • /
    • v.19 no.3
    • /
    • pp.379-387
    • /
    • 2010
  • Sediments of Little Scioto (LS) River in Ohio was contaminated by poor disposal of creosote from Baker Wood Creosoting Facility. Among the primary compounds of creosote, Polycyclic Aromatic Hydrocarbons (PAHs) are the most common ingredient PAHs are known for toxic, carcinogenic and mutagenic compounds. There are many difficulties to remove the PAHs in nature environment because their characteristics are having a less water-solubility, volatile and low mobility properties as increasing the molecular weight. The generation of hydroxyl radicals (${\cdot}OH$) and hydrogen peroxide ($H_2O_2$) forms as well as high temperature (5000 K) and pressure (1000 atm) by a physico-chemical effects of ultrasound during a cavitation collapse can promote the degradation and desorption of PAHs in sediment And it can also produces shock wave and microjets which are able to change the size and surface of particle in solid-liquid system as one of physical effects. Therefore, we explored to understand the role of particle size, the effect of elimination for PAHs concentration by ultrasound and optimize the conditions for ultrasonic treatment. The condition of various size of particles (> $150{\mu}m$, < $150{\mu}m$) and solid-liquid ratio (12.5g/L, 25g/L) for the treatment was considered and ultrasonic power (430 W/L) with liquid - hexane extraction and microwave extraction method were applied after ultrasound treatment.

A Basic Study on Acoustic Conditioning of Fish Suitable for a Marine Ranch -1. The Sound Sensitivity of Japanese Parrot Fish Oplegnathus fasciatus- (해양목장 대상 어류의 음향순치에 관한 기초적 연구 -1. 돌돔의 청각 특성-)

  • Kim Seong Ho;Lee Chang Heon;Seo Du Ok;Kim Yong Ju
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.6
    • /
    • pp.563-567
    • /
    • 2002
  • Developing base data on luring fish schools into netting position by the use of underwater audible sound on japanese parrot fish Oplegnathus fasciatus found in the coastal waters of Jeju Island, S. Korea. Auditory threshold was determined by the heartbeat condition technique using pure tones coupled with a delayed electric shock. The audible range of japanese parrot fish extended from 80 Hz to 500 Hz with a peak sensitivity at 200 Hz. The mean auditory thresholds at the frequencies of 80 Hz, 100 Hz, 200 Hz,300 Hz and 500 Hz were 104 dB, 95 dB, 91 dB, 99 dB and 113 dB, respectively. As the frequency became higher than 200 Hz, the auditory threshold increased almost linearly with increasing frequency. Critical ratios of fishes measured in the presence of masking noise in the spectrum level range of 69$\~$78 dB (0 dB re 1$\mu$Pa/$\sqrt{Hz}$) ranged from 21 dB to 40 dB at test frequencies. The noise spectrum level at the start of masking was about 70 dB within the test frequency range. The sound pressure level of 100$\~$200 Hz recognized by japanese parrot fish under the ambient noise is above 91 dB and the critical ratio for them is above 21 dB.

Research on the Ejection Gas Generator to Improve Ejecting Performance (사출성능 개선을 위한 사출용 가스발생기 연구)

  • Oh, Seok-Jin;Jang, Seung-Gyo;Cha, Hong-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.5
    • /
    • pp.383-390
    • /
    • 2013
  • The reduction of the maximum acceleration which causes shock for a missile is very important to prevent abnormal operation of a missile and decrease size and cost of missile components. Because the maximum acceleration created by operation of an ejection gas generator occurs in the initial ejection stage, the design parameters which affect initial ejection stage were examined. The igniter and the nozzle closure were selected as design parameters of a gas generator. The maximum acceleration created by the gas generator was examined experimentally by changing of the design parameters. Finally the reduction effect of the maximum acceleration was compared quantitatively by static fire test of a gas generator. The maximum acceleration of the best model which was applied to each optimal design parameter was about 68% reduced than that of the reference model.

Effects of Explosion on Structures (폭발이 구조물에 미치는 영향)

  • Yoon, Yong-Kyun
    • Explosives and Blasting
    • /
    • v.37 no.4
    • /
    • pp.10-16
    • /
    • 2019
  • Information on overpressure, positive phase duration, and impulse are required to assess the effects of shock waves or pressure waves on the structure. In this study, the overpressure and positive phase duration were determined by applying the Multi-Energy Method, which is found to be effective in analyzing the explosion of vapor clouds. Based on the total heat of combustion estimated in the cyclohexane vapor cloud explosion in the Nypro Ltd(UK), overpressure and positive phase duration at the distance of 40, 80, 120, 160, 200, 240, 280, 320, 360(m) from the source of explosion were evaluated. Overpressure was shown to decrease exponentially and positive phase duration increased almost linearly with distance. A probit function was used to assess the probability of damages for the structures at each distance using the overpressure and impact obtained at the above mentioned distances. The Analyses of probability of damages have shown that there is a high probability of collapse at distances within 120m, major damage to structures within 240m, and minor damage and breakage of window panes of structures occur over the entire distances.

A Case Report of Bun-Ton Disease Treated by Yang-Ji-Tang (상복부 통증을 奔豚(奔豚)으로 진단하고 양지장(良枳場)을 투여하여 호전된 1례)

  • Seok, Seon-Hee;Park, Se-Hwan;Kim, Geun-Woo;Koo, Byung-Soo
    • Journal of Oriental Neuropsychiatry
    • /
    • v.19 no.2
    • /
    • pp.265-278
    • /
    • 2008
  • Stress reaction can be shown widely in the systems of psychology, endocrinology, immunology and so on. Stress promotes catecholamine from the autonomic nerve system, and this activates the sympathetic nerve system. As the sympathetic nerve system is activated, high blood pressure, tachycardia, vertigo, anxiety, diaphoresis, myotonic reaction and others can happen. Autonomic imbalance is the syndrome that people suffer from various symptoms accompanying no organic lesions and no psychological disorders by losing the hormonies between the sympathetic and parasympathetic nerve system. We experienced a 55 year-old female who complained of sudden abdominal pain after being frightened at trouble with her husband. Her abdominal pain was very characteristic, "Something is like rising in my abdomen.", that occurred several times a day. We diagnosed 'Bun-Ton Disease' from her abdominal sign. Several oriental medicine books recorded aspects of Bun-Ton disease and treatments, we had given herbal medicine and treated acupuncture be based on those. Results from studies to date suggest the Bun-Ton Disease's main cause is fright or shock, and they stimulate releasing epinephrine or norepinephrine, that result in various symptoms. In this case report, we will present this patient's case and review the Bun-Ton Disease.

  • PDF

Safety Pharmacology of CJ-11555 (CJ-11555의 안전성 약리실험)

  • 최재묵;이성학;김일환;박지은;김덕열;노현정;김택로;최광도;김영훈
    • Toxicological Research
    • /
    • v.20 no.2
    • /
    • pp.159-166
    • /
    • 2004
  • Safety pharmacological properties of CJ-11555, an anti-cirrhotic agent, were investigated in experimental animals and in vitro test system. CJ-11555 had no effects on normal body temperature in rats, motor coordination, chemoshock induced by pentetrazol, electric shock induced by electric shocker and writhing syndromes in mice at dose levels of 100, 300 and 1,000 mg/kg. CJ-11555 inhibited intestinal activity and prolonged hexobarbital-induced sleeping time in mice at the dose level of 1,000 mg/kg. CJ-11555 affected on general activity and behaviour tests in SD rats, such as lacrimation, ptosis, piloerection, decreased body tone, abnormal dispersion within the cage, diarrhoea, red colored faeces, slight hypothermia and decreased grooming, at the dose level of 1,000 mg/kg in rats. CJ-11555 was effected on cardiovascular and respiratory system in anesthetized beagle dogs, such as tachycardia, increase of mean blood pressure and decrease of PR interval, decrease of respiratory rate and minute volume, at dose levels of 10 and 30 mg/kg. However, these effects were also observed in vehicle treated anesthetized beagle dogs. In in vitro experiments, CJ-11555 inhibited agonists (histamine, acetyl-choline or $BaCl_2$) induced contraction of isolated guinea-pig at the concentration of 30$\times$$10^6$ M. CJ-11555 was weekly inhibited hERG channel current at concentrations of 10 and 30$\times$$10^6$ M, and $IC_{50}$ was estimated to be higher than 30${\times}$$10^6$M. Based on these results, it was concluded that CJ-11555 affected on cardiovascular and respiratory system, general activity and behaviour and hexobarbital-induced sleeping time at the dose level of 1,000 mg/kg and contraction of the smooth muscle and hERG channel current at the concentration of 30$\times$$10^6$ M.

Outcomes of Venovenous Extracorporeal Membrane Oxygenation Support for Acute Respiratory Distress Syndrome in Adults

  • Ma, Dae-Sung;Kim, Joon-Bum;Jung, Sung-Ho;Choo, Suk-Jung;Chung, Cheol-Hyun;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • v.45 no.2
    • /
    • pp.91-94
    • /
    • 2012
  • Background: Despite improved managements for acute respiratory distress syndrome (ARDS), its mortality remains high. Extracorporeal membrane oxygenation (ECMO) has emerged as the final option for the treatment of ARDS unresponsive to conventional measures. This study describes our experiences of venovenous ECMO support for the treatment of ARDS. Materials and Methods: Between 2007 and 2010, 56 patients (aged $56.6{\pm}13.4$ years, 43 males) received venovenous ECMO for the treatment of ARDS. The detailed clinical records were retrospectively reviewed. Results: Before the institution of ECMO support, 35 patients (55.4%) required nitric oxide inhalation, 35 patients (55.4%) received continuous renal replacement therapy, and 20 patients (35.7%) were in shock status. The median duration of ECMO support was 164 hours (range, 5 to 1,413 hours). 27 (48%) patients could be successfully weaned from ECMO. Of them, 7 (13%) survived to discharge. On logistic regression analysis, a requirement for higher inspiratory pressure before ECMO support was the only significant factor that could predict ECMO weaning failure. Conclusion: The outcome of venovenous ECMO support for the treatment of ARDS was suboptimal. Further improvements in outcomes should be made through the accumulation of experience and establishment of a standardized protocol for the management of ECMO.