• Title/Summary/Keyword: Pressure safety valve

Search Result 219, Processing Time 0.023 seconds

The Development of the Safety Valve for LP Gas Cylinder Using the Sintered Metal (소결금속을 이용한 LPG 용기용 안전 밸브의 개발)

  • Rhim, Jong-Kuk
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.48-52
    • /
    • 2006
  • This study is a research of safety valve development for LP gas cylinder which use sintering metal. Re-searcher wishes to apply technology of sintering metal for safety valve development and do gas flow control. The basis of this study is most suitable fluid examination that to reduce gas accident. This research concluded following results. 1. When press pin length is 42mm to 45mm powder quantity is 0.25g, in case of press pin length 36mm to 42mm powder quantity is 0.2g, displayed fluid optimization. 2. When press pin length is 39mm and powder quantity is 0.25g, press pressure displayed fluid optimization at all interests from $1.2\;tons/cm^{2}\;to\;2\;tons/cm^{2}$. 3. When apparent density is about $5.0g/cm^{3}\;to\;4.5g/cm^{3}$, fluid optimization becomes.

A Study of the Gas Flow through a Safety Valve for LNG Ship Engine (LNG 선박용 안전밸브를 지나는 기체유동에 관한 연구)

  • Lee, Jun-Hee;Kim, Heuy-Dong;Park, Kyung-Am
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.441-447
    • /
    • 2005
  • The present study is aimed at understanding the flow physics associated with a safety valve applied to LNG ship engines. One-dimensional gasdynamic analyses and axisymmetric, compressible Navier-Stokes computations have been carried out to provide a qualitative and quantitative knowledge base for an effective design of the safety valve. Gasdynamic forces and thrust coefficients are obtained regarding a change in chamber pressure and distance between the nozzle exit and valve sheet which are major parameters to offer a variation in the flow feature. The present results show that the control of the passage area between the nozzle exit and valve sheet can attenuate the strength of shockwave generated in front of the valve sheet, which causes harm to stable system operation.

  • PDF

Pressure Wave Propagation in the Discharge Piping with Water Pool

  • Bang Young S.;Seul Kwang W.;Kim In-Goo
    • Nuclear Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.285-294
    • /
    • 2004
  • Pressure wave propagation in the discharge piping with a sparger submerged in a water pool, following the opening of a safety relief valve, is analyzed. To predict the pressure transient behavior, a RELAP5/MOD3 code is used. The applicability of the RELAP5 code and the adequacy of the present modeling scheme are confirmed by simulating the applicable experiment on a water hammer with voiding. As a base case, the modeling scheme was used to calculate the wave propagation inside a vertical pipe with sparger holes and submerged within a water pool. In addition, the effects on wave propagation of geometric factors, such as the loss coefficient, the pipe configuration, and the subdivision of sparger pipe, are investigated. The effects of inflow conditions, such as water slug inflow and the slow opening of a safety relief valve are also examined.

Dynamic Analysis of Air Operated Globe Valve (공기구동형 글로브밸브의 동적거동해석)

  • 양상민;박종학;김동진;허태영;김봉호;신성기;김찬용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1022-1025
    • /
    • 2003
  • Although the globe is the most typical valve to control high pressure drop in piping system, it is very hard to figure out the characteristics of flow field in the globe valve caused by its complex geometry. So there is very few studies to find out flow characteristics of globe valve. In this study, numerical analysis for flow field in the globe valve is carried out using the Fluent code which is commercial CFD program. Pressure drop through the globe valve is also measured to verify the results come from numerical analysis. Comparing experiment with numerical analysis, two results are very close to each other. Also finite element method is employed to evaluate the safety of globe valve using the results coming from the flow analysis to make the boundary conditions for FEM analysis. Maximum stress appears on the inlet channel of valve where inlet flow runs against. Because the maximum stress between 11.7 MPa to 3.6 MPa is within 3.4% of yield stress. the structural safety of valve is considered to be very sound

  • PDF

Waterhammer for the Intake Pumping Station with the Pump Control Valve (펌프제어밸브를 사용한 취수펌프장에서의 수격현상)

  • Kim, Kyung-Yup;Oh, Sang-Hyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.4 s.13
    • /
    • pp.16-21
    • /
    • 2001
  • The field tests on the waterhammer were carried out for PalDang intake pumping station of the metropolitan water supply 5th stage project. The pumping station was equipped with the pump control valve as the main surge suppression device and the surge relief valve as auxiliary. However, the pump control valve had not been early controlled in the planned closing mode, and the slamming occurred to the valve which abruptly closed during the large reverse flow. Because the pressure wave caused by the pump failure was superposed on the slam surge, the upsurge increased so extremely that the shaft of the valve was damaged. It was desirable that the surge relief valve was installed in the pumping station or near the pump exit for the delay of response. After reforming the oil dashpot of the pump control valve, the sliming disappeared and the measured pressure was in fairly good agreement with the results of simulation. In case of three pumps for ${\phi}2,600$ pipeline being simultaneously tripped, the pressure head in the pumping station increased to 95.6 m, and the upsurge caused by the emergency stop of four pumps for ${\phi}2,800$ pipeline was 89.6m. We concluded that the pumping station acquired the safety and reliability for the pressure surge.

  • PDF

A study on the flow characteristics in a plug valve with various port shapes (플러그 밸브의 포트형상 변화에 따른 유동특성 연구)

  • Choi, G.-W.;Park, G.-J.;Kim, Youn J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.259-264
    • /
    • 2000
  • The functions of the plug valve are the control of flow rate as well closing and opening pipe lines. Analyses on the flow characteristics in plug valve port are required to improve the performance and safety at severe operating conditions such as high-pressure and high-temperature. In this study, numerical analyses are carried out with varying the opening rate (fraction of the full open to close) of the valve and the shapes of valve Uk: straight, convex, concave and mixed shapes. The parameters influencing the flow characteristics in the valve are the discharge coefficient( $C_v$) and the resistance coefficient( K). Therefore, the distributions of static pressure, velocity vector and stream lines are investigated, and $C_v$ and K are calculated in each opening rate and shape. In case of full open, the static pressure passed through the valve port has almost been recovered. However, in case of other opening rates, the pressure does not permanently regained due to pressure drop leading to loss. This phenomenon in each shape of the valve shows the different behaviors. Calculation results show that the mixed shape has the best flow attribute.

  • PDF

Shape Design Optimization of Disk Seal in $SF_6$ Gas Safety Valve ($SF_6$ 가스 안전밸브 디스크 시일의 최적설계에 관한 연구)

  • 김청균;조승현
    • Tribology and Lubricants
    • /
    • v.20 no.5
    • /
    • pp.231-236
    • /
    • 2004
  • Sulfur Hexafluoride, S $F_{6}$ is widely used for leak detection and as a gaseous dielectric in transformers, condensers and circuit breakers. S $F_{6}$ gas is also effective as a cleanser in the semiconductor industry. This paper presents a numerical study of the sealing force of disk type seal in S $F_{6}$ gas safety valve. The sealing force on the disk seal is analyzed by the FEM method based on the Taguch's experimental design technique. Disk seals in S $F_{6}$ gas safety valve are designed with 9 design models based on 3 different contact length, compressive ratio and gas pressure. The calculated results of Cauchy stress and strain showed that the sealing characteristics of Teflon $^{ }$PTFE is more effective compared to that of FKM(Viton), which is related to the stiffness of the materials. And also, the contact length of the disk seal is important design parameter for sealing the S $F_{6}$ gas leakage in the safety valve.afety valve.

A Study of Life Characteristics of Butterfly Valve Seated Rubber by Accelerated Life Test (고무시트 버터플라이밸브의 가속수명시험을 통한 수명특성 연구)

  • Lee, Gi-Chun;Lee, Young-Bum
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.5
    • /
    • pp.29-35
    • /
    • 2013
  • Butterfly valve seated rubber has been widely used in water works and industrial fields because it has advantages which are small installation area and low weight. The size and material of butterfly valve have been selected by service environments and purposes. But there are out of the ordinary to find papers for the life characteristics of the butterfly valve. So, this study carries out the accelerated life test, which has an acceleration factor with pressure, using performance and life test equipment. Accelerated model is adopted with 3 stress level and the inverse power law model to estimate the life of the test samples. After the analysis of the test result, accelerated index has 7.0 and the acceleration factor has 208 which is applied with field condition with the pressure 6.3 bar.

Review of Safety for Pressure-Relieving Systems of Small to Middle Scale Chemical Plants (중소규모 화학공장의 압력방출시스템에 대한 안전성 검토)

  • Yim, Ji-Pyo;Jin, Dae-Young;Ma, Byung-Chol;Kang, Sung-Ju;Chung, Chang-Bock
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.48-55
    • /
    • 2015
  • A variety of safety issues were investigated for chemical reactors using a toluene solvent in case of a fire at small to middle scale chemical plants. The issues covered the operation of pressure-relieving valves and the subsequent discharges of the toluene to the atmosphere either directly or through an absorber, which represent the current practice at most small chemical plants. It was shown that the safety valve on the reactor may not operate within about twenty minutes after an external fire breaks out, but, once relieved, the toluene vapor released directly to the atmosphere may form a large explosion range on the ground. It was also shown that if the discharge is routed to an existing absorber used for the scrubbing of volatile organic compounds or dusts, the column may not operate normally due to excessive pressure drops or flooding, resulting in the hazardous release of toluene vapors. This study proposed two ways of alleviating these risks. The first is to ruduce the discharge itself from the safety valve by using adequate insulation and protection covers on the reactor and then introduce it into the circulation water at the bottom of the absorber through a dip linet pipe equipped with a ring-shaped sparger. This will enhance the condensation of toluene vapors with the reduced effluent vapors treated in the packing layers above. The second is to install a separate quench drum to condense the routed toluene vapors more effectively than the existing absorber.

Development of Check Angle Safety Valve for Residential Gas Piping (주택용 가스배관 체크앵글 안전밸브 개발 연구)

  • Lim, Sang Ho
    • Industry Promotion Research
    • /
    • v.2 no.1
    • /
    • pp.9-13
    • /
    • 2017
  • This study deals with the check valve safety valve for residential gas piping. It can be manually shut off within 1 second in case of emergency, and it is possible to touch 3kg of pressure by hand force. To develop the technology so that it can be used repeatedly. Study results after first valve operation. And 0.61 seconds on average. Therefore, it was found that there was no problem in operation even when used as a safety valve. Third, it was found that all of the results of using the blocking ball diameter of 7mm were not abnormal. In this study, it is meaningful to develop the check valve safety valve of gas piping and verify the performance by testing with existing valve.