• Title/Summary/Keyword: Pressure resistance

Search Result 2,168, Processing Time 0.029 seconds

Chloride Attack Resistibility of Marine Concrete under Pressure (압력을 받는 해양콘크리트의 염해저항성)

  • Kim, Gyeong-Tae;Kim, Gyu-Yong;Lee, Sang-Kyu;Hwang, Eui-Chul;Son, Min-Jae;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.52-53
    • /
    • 2018
  • As a result of exposing the concrete at 1 and 6 atm in order to evaluate the salt resistance of the pressurized marine concrete, the pressure resulted in promoting the chloride ion penetration of the concrete. Particularly, the amount of water soluble chloride in the surface area tends to increase rapidly, and this cause is considered to be highly correlated with the size of the capillary pores of the concrete. On the other hand, the blending of blast furnace slag was effective to increse chloride attack resistibility even under the pressure.

  • PDF

A Cantilever Type Contact Force Sensor Array for Blood Pressure Measurement (혈압 측정을 위한 외팔보형 접촉힘 센서 어레이)

  • Lee, Byeung-Leul;Jung, Jin-Woo;Chun, Kuk-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.121-126
    • /
    • 2012
  • Piezoresistive type contact force sensor array is fabricated by (111) Silicon bulk micromachining for continuous blood pressure monitoring. Length and width of the unit sensor structure is $200{\mu}m$ and $190{\mu}m$, respectively. The gap between sensing elements is only $10{\mu}m$. To achieve wafer level packaging, the sensor structure is capped by PDMS soft cap using wafer molding and bonding process with $10{\mu}m$ alignment precision. The resistance change over contact force was measured to verify the feasibility of the proposed sensor scheme. The maximum measurement range and resolution is 900 mm Hg and 0.57 mm Hg, respectively.

Micro-PIV Measurements of interfacial electrokinetic effects in a microchannel (마이크로 PTV 기법을 이용한 미세채널 내부 계면의 electrokinetic 효과 해석)

  • Kim Guk-bae;Lee Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.49-50
    • /
    • 2002
  • In micro-channels, the electro-viscous effect is caused by the electrical double layer on pressure-driven liquid flow. Velocity fields of flow inside micro-channels were measured using micro-PIV system for investigating the electro-viscous effect. De-ionized water and aqueous NaCl solutions with four different concentrations were used as working fluid in a PDMS micro-channel of $100{\mu}m$ width and $66{\mu}m$ height. The pressure gradient, dP/dx, was determined from the pre-determined input flow rate Q of syringe pump. The mean velocity $u_m$ used for calculating Reynolds number was obtained from the PIV velocity field data. These are used to plot the pressure gradient as a function of Reynolds numbers. The pressure gradient far lower concentration solution $(10^{-5}\;M)$ was higher than that for the higher concentration solution. The increase of flow resistance was about $30\%\;and\;37.5\%$ at Re=0.02 and 0.06, respectively.

  • PDF

A Study on the Closing Force according to the Opening Angle of the Door in the Smoke Control System (제연구역 출입문 개방 각도에 따른 폐쇄력에 관한 연구)

  • Oh, Won-Sin;Joung, Suck-Hwan
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.43-48
    • /
    • 2021
  • In this study, the experiment was conducted on a fire door(W × H = 0.98 m × 2.19 m) installed on the vestibule. The effective leakage area for each opening angles and closing forces derived from the impulse-momentum equation was compared and analyzed with the experimental results. As a result of the experiment, the major factors affecting the door closing forces were the pressure difference and the area of the door. The difference of door closing forces between measured and calculated values by the impulse-momentum equation showed a deviation of less than ±15% at the opening angles of 5°to 10°. At the door opening angle of 2.5°, the dynamic pressure was much higher than the measured static pressure, and this pressure difference is estimated to be air resistance acting to prevent the door from being completely closed.

Silicon Pressure Sensors Using Diffused Resistors (확산저항을 이용한 실리콘 압력 센서)

  • Kwon, Tae Ha;Lee, Wu Il
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.3
    • /
    • pp.364-369
    • /
    • 1986
  • Silicon diaphragms, 10 and 20 \ulcorner-thick and 1x1 mm\ulcornerarea, have been fabricated by means of the electrochemical P-N junction etch-stop technique. The P-type diffused resistors were formed on the diaphragm, and the piezoresistance effect was examined. It was been found that the fractional variation of the resistance is dependent on the diaphragm thickness, resistor location, and resistor length, etc. The 1.2 k\ulcornerfull-brige pressure sensor with 10\ulcorner-thick diaphragm exhibits a pressure sensitivity of 42 \ulcorner/V\ulcornermHg with a temperature coefficient of 2.3 mmHg/\ulcorner, and shows a good linearity in the pressure range from 0 to 300 mmHg.

  • PDF

The Tense-Lax Question and Intraoral Air Pressure in English Stops

  • Kim, Dae-Won
    • Speech Sciences
    • /
    • v.9 no.4
    • /
    • pp.113-130
    • /
    • 2002
  • Measurements were made of pressure rise time (PoRT), voice cessation time, flattened peak intraoral air pressure (Po), pressure static time (PoST), pressure-fall time and the duration of oral closure as four English speakers uttered isolated nonsense $V_{1}CV_{2}$ words containing /b/ and /p/ ($V_{1}=V_{2}$ and the V was /$\alpha$/), with stress on either $V_{1}orV_{2}$ alternately. The hypothesis tested was: The tense stop consonant. will be characterized either by a higher Po or a longer PoST, and/or by both against lax. Findings: (1) PoRT was significantly greater in /b/ than /p/, (2) the voiceless stop /p/ produced generally greater mean Po, averaged across five tokens, than its voiced counterpart /b/, but statistically insignificant, and (3) altogether, across stress, tokens and subjects, the difference in the calculated pressure static time (PoSTc), i.e., PoST + PoRT, between /p/ and /b/ was highly significant (p $\leq$ 0.003). Although further investigations remain to be taken, the results strongly supported the linguistic hypothesis of tense-lax distinction, with /b/ being lax and /p/ tense. Airflow resistance at the glottis and supraglottal air volume are assumed to be responsible for much of difference in PoRT between /p/ and /b/. The PoSTc reflecting, although indirectly, the respiratory efforts during the oral closure of a stop, was a convincing phonetic parameter of the consonantal tenseness based on respiratory efforts. The effects of stress on Po and PoSTc were inconsistent, and the shorter PoRT than consonantal constriction interval was always accompanied by Po and PoST.

  • PDF

Pulmonary Hypertensive Crises After Surgery for Congenital Heart Defects in Children (소아 선천성 개심수술후의 폐동맥 고혈압 발작증)

  • 서필원
    • Journal of Chest Surgery
    • /
    • v.22 no.6
    • /
    • pp.944-950
    • /
    • 1989
  • Children with congenital cardiac defects associated with high pulmonary artery pressure may die despite accurate surgery. Postoperative mortality and morbidity have been attributed to acute rises in pulmonary artery pressure and resistance. Acute pulmonary hypertensive crisis is defined as a paroxysmal event in which pulmonary arterial systolic pressure rises to or above systemic levels followed by a rapid fall in systemic pressure and a minor pulmonary hypertensive event is defined as an acute rise in pulmonary arterial pressure to more than 80 % of systemic levels but without a fall in systemic pressure. From Oct. 1988 to Jul. 1989, we experienced 23 patients who showed many pulmonary hypertensive crises after operation in the Department of Thoracic and Cardiovascular Surgery, Seoul National University Children\ulcorner Hospital. Their preoperative PAP/SAPs were 53 to 123 %[mean 93.3%] and diagnoses were VSD[7], TAPVR[5], TGA[4], AVSD[3], MS[1], DORV[1], Truncus arteriosus[1], and AP window[l]. There were 9 deaths among 23 patients and they showed many pulmonary hypertensive crisis episodes during postoperative intensive care, which was managed by sedation, hyperventilation, oxygen, and acidosis correction and which decreased after using tolazoline. In view of our experience, we recommend that pulmonary artery pressure should be monitored in congenital heart defected patient with preoperative pulmonary hypertension to confirm and to manage the pulmonary hypertensive crisis accurately and using tolazoline is helpful in the treatment of pulmonary hypertensive crisis.

  • PDF

Subglottic Air Pressure in Different Phonetic Context (음성학적 문맥에 따른 성문하압의 차이에 관한 연구)

  • 박상희;정옥란;석동일
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.13 no.1
    • /
    • pp.23-27
    • /
    • 2002
  • The purpose of the study is to examine differences in subglottic air pressure as a function of phonetic context. The phonetic contexts consisted of $/i:{p^h}i:{p^h}i:/,/{p^h}i:{p^h}i:/, and /{p^h}{p^h}/$. The aerodynamic and phonatory parameters are investigated in 20 female normal adults. All measurements are taken and analysed using Aerophone II voice function analyzer. The aerodynamic parameters are Peak Air Pressure(PAP) and Mean Air Pressure(MAP), and the phonatory parameters are Phonatory Flow Rate(PFR) Maximum SPL(MSPL), Phonatory SPL(PSPL), Phonatory Power (PP), Phonatory Efficiency(PE), and Phonatory $Resistance^*$ 10-5(PR). A one-way ANOVA revealed the following results. First, the aerodynamic parameters are not significantly different. Second, Peak Air Pressure(PAP) and Mean Air Pressure(MAP), as well as the phonatory parameters such as Phonatory Flow Rate(PFR) Maximum SPL(MSPL), Phonatory SPL(PSPL), and Phonatory Efficiency(PE) were significantly different. Therefore, it is advised that clinicians use only aerodynamic parameters but phonatory parameters when using Aerophone II.

  • PDF

Hydrogen Embrittlement of Two Austenitic High-Manganese Steels Using Tensile Testing under High-Pressure Gaseous Hydrogen (고압 수소 가스 하 인장 시험을 이용한 두 오스테나이트계 고망간강의 수소취화 특성 평가)

  • Lee, Seung-Yong;Baek, Un-Bong;Nam, Seung Hoon;Hwang, Byoungchul
    • Korean Journal of Materials Research
    • /
    • v.26 no.7
    • /
    • pp.353-358
    • /
    • 2016
  • The hydrogen embrittlement of two austenitic high-manganese steels was investigated using tensile testing under high-pressure gaseous hydrogen. The test results were compared with those of different kinds of austenitic alloys containing Ni, Mn, and N in terms of stress and ductility. It was found that the ultimate tensile stress and ductility were more remarkably decreased under high-pressure gaseous hydrogen than under high-pressure gaseous argon, unlike the yield stress. In the specimens tested under high-pressure gaseous hydrogen, transgranular fractures were usually observed together with intergranular cracking near the fracture surface, whereas in those samples tested under high-pressure gaseous argon, ductile fractures mostly occurred. The austenitic high-manganese steels showed a relatively lower resistance to hydrogen embrittlement than did those with larger amounts of Ni because the formation of deformation twins or microbands in austenitic high-manganese steels probably promoted planar slip, which is associated with localized deformation due to gaseous hydrogen.

A Study About Critical Flow Characteristics and the Pipeline Network Modeling of a Pressure Regulator (I) - The Influence of a Pressure Ratio - (정압기의 임계유동 특성과 배관망해석 모델링에 관한 연구 (I) - 압력비 영향 -)

  • Shin Chang Hoon;Ha Jong Man;Lee Cheol Gu;Her Jae Young;Im Ji Hyun;Joo Won Gu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.12 s.243
    • /
    • pp.1291-1298
    • /
    • 2005
  • Since the interior shape of a pressure regulator is complex and the change of fluid resistance at each operation condition is rapid and big, the pressure regulator can become the major factor that causes big loss in pipelines. So the suitable pressure regulator modeling by each operation condition is important to obtain reliable results especially in small scale pipeline network analysis. And in order to prevent the condensation and freezing problems, it is needed to confirm both whether temperature recovery is achieved after passing by the pressure regulator's narrow neck and how much amount of low temperature area that can cause condensate accumulation is distributed by various PCV models at every inlet-outlet pressure ratio. In this research, the numerical model resembling P company pressure regulator that is used widely for high pressure range in commercial, is adopted as the base model of CFD analysis to investigate pressure regulator's flow characteristics at each pressure ratio. Additionally it is also introduced to examine pressure regulator's critical flow characteristics and possibility of condensation or freezing at each pressure ratio. Furthermore, the comparison between the results of CFD analysis and the results of analytic solution obtained by compressible fluid-dynamics theory is attempted to validate the results of CFD modeling in this study and to estimate the accuracy of theoretical approach at each pressure ratio too.